private Int64 UpdateTran(CMMeasurementBookEntity cMMeasurementBookEntity, String filterExpression, DatabaseOperationType option)
        {
            long         returnCode = -99;
            const string SP         = "dbo.CMMeasurementBook_SET";

            Database db = DatabaseFactory.CreateDatabase();

            using (DbCommand cmd = db.GetStoredProcCommand(SP))
            {
                AddOptionParameter(cmd, option, db);
                AddOutputParameter(cmd, db);
                AddFilterExpressionParameter(cmd, filterExpression, db);

                db.AddInParameter(cmd, "@MeasurementBookID", DbType.Int64, cMMeasurementBookEntity.MeasurementBookID);
                db.AddInParameter(cmd, "@ProjectID", DbType.Int64, cMMeasurementBookEntity.ProjectID);
                db.AddInParameter(cmd, "@ProjectCode", DbType.String, cMMeasurementBookEntity.ProjectCode);
                db.AddInParameter(cmd, "@VendorCategoryID", DbType.Int64, cMMeasurementBookEntity.VendorCategoryID);
                db.AddInParameter(cmd, "@ReferenceID", DbType.Int64, cMMeasurementBookEntity.ReferenceID);
                db.AddInParameter(cmd, "@BillID", DbType.Int64, cMMeasurementBookEntity.BillID);
                db.AddInParameter(cmd, "@WorkOrderID", DbType.Int64, cMMeasurementBookEntity.WorkOrderID);
                db.AddInParameter(cmd, "@ItemID", DbType.Int64, cMMeasurementBookEntity.ItemID);
                db.AddInParameter(cmd, "@CreateDate", DbType.DateTime, cMMeasurementBookEntity.CreateDate);
                db.AddInParameter(cmd, "@ProjectFloorID", DbType.Int64, cMMeasurementBookEntity.ProjectFloorID);
                db.AddInParameter(cmd, "@ProjectFloorUnitID", DbType.Int64, cMMeasurementBookEntity.ProjectFloorUnitID);

                DbConnection connection = db.CreateConnection();
                connection.Open();
                DbTransaction transaction = connection.BeginTransaction();

                try
                {
                    using (IDataReader reader = db.ExecuteReader(cmd, transaction))
                    {
                        returnCode = GetReturnCodeFromParameter(cmd);
                    }

                    if (returnCode > 0)
                    {
                        transaction.Commit();
                    }
                    else
                    {
                        throw new ArgumentException("Error Code." + returnCode.ToString());
                    }
                }
                catch (Exception ex)
                {
                    transaction.Rollback();
                    throw ex;
                }
                finally
                {
                    transaction.Dispose();
                    connection.Close();
                    connection = null;
                }
            }

            return(returnCode);
        }
        Int64 ICMMeasurementBookDataAccess.Add(CMMeasurementBookEntity cMMeasurementBookEntity, DatabaseOperationType option, TransactionRequired reqTran)
        {
            try
            {
                long retValues = -99;

                switch (reqTran)
                {
                case TransactionRequired.No:
                {
                    retValues = Add(cMMeasurementBookEntity, option);
                    break;
                }

                case TransactionRequired.Yes:
                {
                    retValues = AddTran(cMMeasurementBookEntity, option);
                    break;
                }

                default:
                {
                    retValues = -99;
                    break;
                }
                }

                return(retValues);
            }
            catch (Exception ex)
            {
                throw ex;
            }
        }
        private void PrepareEditView()
        {
            CMMeasurementBookEntity cMMeasurementBookEntity = CurrentCMMeasurementBookEntity;


            if (!cMMeasurementBookEntity.IsNew)
            {
                if (ddlProjectID.Items.Count > 0 && cMMeasurementBookEntity.ProjectID != null)
                {
                    ddlProjectID.SelectedValue = cMMeasurementBookEntity.ProjectID.ToString();
                }

                txtProjectCode.Text = cMMeasurementBookEntity.ProjectCode.ToString();

                if (ddlVendorCategoryID.Items.Count > 0 && cMMeasurementBookEntity.VendorCategoryID != null)
                {
                    ddlVendorCategoryID.SelectedValue = cMMeasurementBookEntity.VendorCategoryID.ToString();
                }

                BuildVendorByVendorCategory();

                if (ddlSupplierID.Items.Count > 0 && cMMeasurementBookEntity.ReferenceID != null)
                {
                    ddlSupplierID.SelectedValue = cMMeasurementBookEntity.ReferenceID.ToString();
                }

                BuildWorkOrderBySupplierID();

                if (ddlBillID.Items.Count > 0 && cMMeasurementBookEntity.BillID != null)
                {
                    ddlBillID.SelectedValue = cMMeasurementBookEntity.BillID.ToString();
                }
                else
                {
                    ddlBillID.SelectedValue = "0";
                }

                if (ddlWorkOrderID.Items.Count > 0 && cMMeasurementBookEntity.WorkOrderID != null)
                {
                    ddlWorkOrderID.SelectedValue = cMMeasurementBookEntity.WorkOrderID.ToString();
                }
                else
                {
                    ddlWorkOrderID.SelectedValue = MasterDataConstants.ItemDefaults.DEFAULT_WORKORDER.ToString();
                    BuildWorkOrderItem();
                }

                if (ddlItemID.Items.Count > 0 && cMMeasurementBookEntity.ItemID != null)
                {
                    ddlItemID.SelectedValue = cMMeasurementBookEntity.ItemID.ToString();
                }

                btnSubmit.Text    = "Update";
                btnAddNew.Visible = true;
            }
        }
示例#4
0
        private void SaveCMMeasurementBookEntity()
        {
            if (IsValid)
            {
                try
                {
                    CMMeasurementBookEntity cMMeasurementBookEntity = BuildCMMeasurementBookEntity();

                    Int64 result = -1;

                    if (cMMeasurementBookEntity.IsNew)
                    {
                        result = FCCCMMeasurementBook.GetFacadeCreate().Add(cMMeasurementBookEntity, DatabaseOperationType.Add, TransactionRequired.No);
                    }
                    else
                    {
                        String filterExpression = SqlExpressionBuilder.PrepareFilterExpression(CMMeasurementBookEntity.FLD_NAME_MeasurementBookID, cMMeasurementBookEntity.MeasurementBookID.ToString(), SQLMatchType.Equal);
                        result = FCCCMMeasurementBook.GetFacadeCreate().Update(cMMeasurementBookEntity, filterExpression, DatabaseOperationType.Update, TransactionRequired.No);
                    }

                    if (result > 0)
                    {
                        _MeasurementBookID       = 0;
                        _CMMeasurementBookEntity = new CMMeasurementBookEntity();
                        PrepareInitialView();
                        BindCMMeasurementBookList();

                        if (cMMeasurementBookEntity.IsNew)
                        {
                            MiscUtil.ShowMessage(lblMessage, "C MMeasurement Book Information has been added successfully.", false);
                        }
                        else
                        {
                            MiscUtil.ShowMessage(lblMessage, "C MMeasurement Book Information has been updated successfully.", false);
                        }
                    }
                    else
                    {
                        if (cMMeasurementBookEntity.IsNew)
                        {
                            MiscUtil.ShowMessage(lblMessage, "Failed to add Measurement Book Information.", false);
                        }
                        else
                        {
                            MiscUtil.ShowMessage(lblMessage, "Failed to update Measurement Book Information.", false);
                        }
                    }
                }
                catch (Exception ex)
                {
                    MiscUtil.ShowMessage(lblMessage, ex.Message, true);
                }
            }
        }
示例#5
0
        protected void lvCMMeasurementBook_ItemCommand(object sender, ListViewCommandEventArgs e)
        {
            Int64 MeasurementBookID;

            Int64.TryParse(e.CommandArgument.ToString(), out MeasurementBookID);

            if (MeasurementBookID > 0)
            {
                if (string.Equals(e.CommandName, "EditItem"))
                {
                    _MeasurementBookID = MeasurementBookID;

                    PrepareEditView();

                    cpeEditor.Collapsed   = false;
                    cpeEditor.ClientState = "false";
                }
                else if (string.Equals(e.CommandName, "DeleteItem"))
                {
                    try
                    {
                        Int64 result = -1;

                        String fe = SqlExpressionBuilder.PrepareFilterExpression(CMMeasurementBookEntity.FLD_NAME_MeasurementBookID, MeasurementBookID.ToString(), SQLMatchType.Equal);

                        CMMeasurementBookEntity cMMeasurementBookEntity = new CMMeasurementBookEntity();


                        result = FCCCMMeasurementBook.GetFacadeCreate().Delete(cMMeasurementBookEntity, fe, DatabaseOperationType.Delete, TransactionRequired.No);

                        if (result == 0)
                        {
                            _MeasurementBookID       = 0;
                            _CMMeasurementBookEntity = new CMMeasurementBookEntity();
                            PrepareInitialView();
                            BindCMMeasurementBookList();

                            MiscUtil.ShowMessage(lblMessage, "C MMeasurement Book has been successfully deleted.", true);
                        }
                        else
                        {
                            MiscUtil.ShowMessage(lblMessage, "Failed to delete C MMeasurement Book.", true);
                        }
                    }
                    catch (Exception ex)
                    {
                        MiscUtil.ShowMessage(lblMessage, ex.Message, true);
                    }
                }
            }
        }
        private Int64 DeleteTran(CMMeasurementBookEntity cMMeasurementBookEntity, String filterExpression, DatabaseOperationType option)
        {
            long         returnCode = -99;
            const string SP         = "dbo.CMMeasurementBook_SET";

            Database db = DatabaseFactory.CreateDatabase();


            using (DbCommand cmd = db.GetStoredProcCommand(SP))
            {
                AddOptionParameter(cmd, option);
                AddOutputParameter(cmd, db);
                AddFilterExpressionParameter(cmd, filterExpression, db);


                DbConnection connection = db.CreateConnection();
                connection.Open();
                DbTransaction transaction = connection.BeginTransaction();

                try
                {
                    using (IDataReader reader = db.ExecuteReader(cmd, transaction))
                    {
                        returnCode = GetReturnCodeFromParameter(cmd);
                    }

                    if (returnCode >= 0)
                    {
                        transaction.Commit();
                    }
                    else
                    {
                        throw new ArgumentException("Error Code." + returnCode.ToString());
                    }
                }
                catch (Exception ex)
                {
                    transaction.Rollback();
                    throw ex;
                }
                finally
                {
                    transaction.Dispose();
                    connection.Close();
                    connection = null;
                }
            }

            return(returnCode);
        }
        private Int64 Update(CMMeasurementBookEntity cMMeasurementBookEntity, String filterExpression, DatabaseOperationType option)
        {
            long         returnCode = -99;
            const string SP         = "dbo.CMMeasurementBook_SET";

            using (DbCommand cmd = Database.GetStoredProcCommand(SP))
            {
                AddOptionParameter(cmd, option);
                AddOutputParameter(cmd);
                AddFilterExpressionParameter(cmd, filterExpression);

                Database.AddInParameter(cmd, "@MeasurementBookID", DbType.Int64, cMMeasurementBookEntity.MeasurementBookID);
                Database.AddInParameter(cmd, "@ProjectID", DbType.Int64, cMMeasurementBookEntity.ProjectID);
                Database.AddInParameter(cmd, "@ProjectCode", DbType.String, cMMeasurementBookEntity.ProjectCode);
                Database.AddInParameter(cmd, "@VendorCategoryID", DbType.Int64, cMMeasurementBookEntity.VendorCategoryID);
                Database.AddInParameter(cmd, "@ReferenceID", DbType.Int64, cMMeasurementBookEntity.ReferenceID);
                Database.AddInParameter(cmd, "@BillID", DbType.Int64, cMMeasurementBookEntity.BillID);
                Database.AddInParameter(cmd, "@WorkOrderID", DbType.Int64, cMMeasurementBookEntity.WorkOrderID);
                Database.AddInParameter(cmd, "@ItemID", DbType.Int64, cMMeasurementBookEntity.ItemID);
                Database.AddInParameter(cmd, "@CreateDate", DbType.DateTime, cMMeasurementBookEntity.CreateDate);
                Database.AddInParameter(cmd, "@ProjectFloorID", DbType.Int64, cMMeasurementBookEntity.ProjectFloorID);
                Database.AddInParameter(cmd, "@ProjectFloorUnitID", DbType.Int64, cMMeasurementBookEntity.ProjectFloorUnitID);

                using (IDataReader reader = Database.ExecuteReader(cmd))
                {
                    returnCode = GetReturnCodeFromParameter(cmd);

                    switch (returnCode)
                    {
                    case SqlConstants.DB_STATUS_CODE_DATAALREADYEXIST:
                    {
                        throw new ArgumentException("CMMeasurementBookEntity already exists. Please specify another CMMeasurementBookEntity.");
                    }

                    case SqlConstants.DB_STATUS_CODE_DATAUPDATEDFROMOTHERSESSION:
                    {
                        throw new ArgumentException("CMMeasurementBookEntity data already updated from different session.");
                    }

                    case SqlConstants.DB_STATUS_CODE_FAIL_OPERATION:
                    {
                        throw new ArgumentException("CMMeasurementBookEntity already exists. Please specify another CMMeasurementBookEntity.");
                    }
                    }
                }
            }

            return(returnCode);
        }
示例#8
0
        private void PrepareEditView()
        {
            CMMeasurementBookEntity cMMeasurementBookEntity = CurrentCMMeasurementBookEntity;


            if (!cMMeasurementBookEntity.IsNew)
            {
                if (ddlProjectID.Items.Count > 0 && cMMeasurementBookEntity.ProjectID != null)
                {
                    ddlProjectID.SelectedValue = cMMeasurementBookEntity.ProjectID.ToString();
                }

                txtProjectCode.Text = cMMeasurementBookEntity.ProjectCode.ToString();

                if (ddlSupplierID.Items.Count > 0 && cMMeasurementBookEntity.ReferenceID != null)
                {
                    ddlSupplierID.SelectedValue = cMMeasurementBookEntity.ReferenceID.ToString();
                }
                if (ddlBillID.Items.Count > 0 && cMMeasurementBookEntity.BillID != null)
                {
                    ddlBillID.SelectedValue = cMMeasurementBookEntity.BillID.ToString();
                }
                else
                {
                    ddlBillID.SelectedValue = "0";
                }

                if (ddlWorkOrderID.Items.Count > 0 && cMMeasurementBookEntity.WorkOrderID != null)
                {
                    ddlWorkOrderID.SelectedValue = cMMeasurementBookEntity.WorkOrderID.ToString();
                }
                else
                {
                    ddlWorkOrderID.SelectedValue = "0";
                }

                if (ddlItemID.Items.Count > 0 && cMMeasurementBookEntity.ItemID != null)
                {
                    ddlItemID.SelectedValue = cMMeasurementBookEntity.ItemID.ToString();
                }

                btnSubmit.Text    = "Update";
                btnAddNew.Visible = true;
            }
        }
        private void UpdateMeasurementBookFloorInfo()
        {
            String fe_MeasurementBook = SqlExpressionBuilder.PrepareFilterExpression(CMMeasurementBookEntity.FLD_NAME_MeasurementBookID, CurrentCMMeasurementBook_DetailedEntity.MeasurementBookID.ToString(), SQLMatchType.Equal);
            CMMeasurementBookEntity cMMeasurementBookEntity = FCCCMMeasurementBook.GetFacadeCreate().GetByID(CurrentCMMeasurementBook_DetailedEntity.MeasurementBookID);

            if (cMMeasurementBookEntity != null && cMMeasurementBookEntity.MeasurementBookID > 0)
            {
                if (ddlProjectFloorID.SelectedValue != "0" && ddlProjectFloorID.Items.Count > 0)
                {
                    cMMeasurementBookEntity.ProjectFloorID = Int64.Parse(ddlProjectFloorID.SelectedValue);
                }
                else
                {
                    cMMeasurementBookEntity.ProjectFloorID = null;
                }

                FCCCMMeasurementBook.GetFacadeCreate().Update(cMMeasurementBookEntity, fe_MeasurementBook, DatabaseOperationType.Update, TransactionRequired.No);
            }
        }
        private Int64 Delete(CMMeasurementBookEntity cMMeasurementBookEntity, String filterExpression, DatabaseOperationType option)
        {
            long         returnCode = -99;
            const string SP         = "dbo.CMMeasurementBook_SET";

            using (DbCommand cmd = Database.GetStoredProcCommand(SP))
            {
                AddOptionParameter(cmd, option);
                AddOutputParameter(cmd);
                AddFilterExpressionParameter(cmd, filterExpression);


                using (IDataReader reader = Database.ExecuteReader(cmd))
                {
                    returnCode = GetReturnCodeFromParameter(cmd);

                    switch (returnCode)
                    {
                    case SqlConstants.DB_STATUS_CODE_DATAALREADYEXIST:
                    {
                        throw new ArgumentException("CMMeasurementBookEntity already exists. Please specify another CMMeasurementBookEntity.");
                    }

                    case SqlConstants.DB_STATUS_CODE_DATAUPDATEDFROMOTHERSESSION:
                    {
                        throw new ArgumentException("CMMeasurementBookEntity data already updated from different session.");
                    }

                    case SqlConstants.DB_STATUS_CODE_FAIL_OPERATION:
                    {
                        throw new ArgumentException("CMMeasurementBookEntity already exists. Please specify another CMMeasurementBookEntity.");
                    }
                    }
                }
            }

            return(returnCode);
        }
示例#11
0
 protected void btnAddNew_Click(object sender, EventArgs e)
 {
     _MeasurementBookID       = 0;
     _CMMeasurementBookEntity = new CMMeasurementBookEntity();
     PrepareInitialView();
 }
示例#12
0
        private CMMeasurementBookEntity BuildCMMeasurementBookEntity()
        {
            CMMeasurementBookEntity cMMeasurementBookEntity = CurrentCMMeasurementBookEntity;

            if (ddlProjectID.Items.Count > 0)
            {
                if (ddlProjectID.SelectedValue == "0")
                {
                }
                else
                {
                    cMMeasurementBookEntity.ProjectID = Int64.Parse(ddlProjectID.SelectedValue);
                }
            }

            cMMeasurementBookEntity.ProjectCode = txtProjectCode.Text.Trim();
            if (ddlSupplierID.Items.Count > 0)
            {
                if (ddlSupplierID.SelectedValue == "0")
                {
                }
                else
                {
                    cMMeasurementBookEntity.ReferenceID = Int64.Parse(ddlSupplierID.SelectedValue);
                }
            }

            if (ddlBillID.Items.Count > 0)
            {
                if (ddlBillID.SelectedValue == "0")
                {
                    cMMeasurementBookEntity.BillID = null;
                }
                else
                {
                    cMMeasurementBookEntity.BillID = Int64.Parse(ddlBillID.SelectedValue);
                }
            }

            if (ddlWorkOrderID.Items.Count > 0)
            {
                if (ddlWorkOrderID.SelectedValue == "0")
                {
                    cMMeasurementBookEntity.WorkOrderID = null;
                }
                else
                {
                    cMMeasurementBookEntity.WorkOrderID = Int64.Parse(ddlWorkOrderID.SelectedValue);
                }
            }

            if (ddlItemID.Items.Count > 0)
            {
                if (ddlItemID.SelectedValue == "0")
                {
                }
                else
                {
                    cMMeasurementBookEntity.ItemID = Int64.Parse(ddlItemID.SelectedValue);
                }
            }

            cMMeasurementBookEntity.CreateDate = MiscUtil.ParseToDateTime(System.DateTime.Now.ToStringDefault());

            return(cMMeasurementBookEntity);
        }
示例#13
0
 Int64 ICMMeasurementBookFacade.Delete(CMMeasurementBookEntity cMMeasurementBookEntity, String filterExpression, DatabaseOperationType option, TransactionRequired reqTran)
 {
     return(DataAccessFactory.CreateCMMeasurementBookDataAccess().Delete(cMMeasurementBookEntity, filterExpression, option, reqTran));
 }
示例#14
0
 Int64 ICMMeasurementBookFacade.Add(CMMeasurementBookEntity cMMeasurementBookEntity, DatabaseOperationType option, TransactionRequired reqTran)
 {
     return(DataAccessFactory.CreateCMMeasurementBookDataAccess().Add(cMMeasurementBookEntity, option, reqTran));
 }