//// BUTTONCLICK HANDLERS /////////////////////////////////////////////// public DialogResult OKButton_Click(object sender, EventArgs e) { DialogResult dr = DialogResult.Cancel; if (ap.modified) { INCCDB.AcquireSelector sel = new INCCDB.AcquireSelector(det, ap.item_type, DateTime.Now); ap.MeasDateTime = sel.TimeStamp; ap.lm.TimeStamp = sel.TimeStamp; NC.App.DB.AddAcquireParams(sel, ap); // it's a new one, not the existing one modified } // The acquire is set to occur if (ap.data_src != ConstructedSource.Reanalysis) // Reanalysis is a bit backwards, the correct measurement is fully constructed before this point { LMAcquire.ResetMeasurement(); } switch (ap.data_src) { case ConstructedSource.Live: // set up the instrument list for the action controller Integ.BuildMeasurement(ap, det, mo); UIIntegration.Controller.file = false; // make sure to use the DAQ controller, not the file controller NC.App.AppContext.FileInput = null; // reset the cmd line file input flag if (det.ListMode) { // patch override lm.Interval with run_count_time from dialog // the acquire dialogs field values, as seen and modified by the user, override the LM-only acquire settings for virtual SR measurements NC.App.Opstate.Measurement.AcquireState.lm.Interval = NC.App.Opstate.Measurement.AcquireState.run_count_time; NC.App.Opstate.Measurement.AcquireState.lm.Cycles = NC.App.Opstate.Measurement.AcquireState.num_runs; // Check NC.App.Opstate.Measurement.AnalysisParams for at least one VSR // If not present, inform and pop up the wizard // If present, inform with new dialog, do not pop up the wizard if (NC.App.Opstate.Measurement.AnalysisParams.HasMatchingVSR(det.MultiplicityParams)) { dr = DialogResult.OK; } else { dr = (new LMAcquire(ap, det, fromINCC5Acq: true)).ShowDialog(); // analyzers are created in here, placed on global measurement if (dr == DialogResult.OK) { NC.App.DB.UpdateAcquireParams(ap); //update it again NC.App.DB.UpdateDetector(det); } } if (dr == DialogResult.OK) { // if ok, the analyzers are set up, so can kick it off now. UIIntegration.Controller.ActivateDetector(det); } } else { SRInstrument sri = new SRInstrument(det); sri.selected = true; sri.Init(NC.App.Loggers.Logger(LMLoggers.AppSection.Data), NC.App.Loggers.Logger(LMLoggers.AppSection.Analysis)); if (!Instruments.All.Contains(sri)) { Instruments.All.Add(sri); // add to global runtime list } dr = DialogResult.OK; } break; case ConstructedSource.DB: NC.App.AppContext.DBDataAssay = true; UIIntegration.Controller.file = true; IDDAcquireDBMeas dbdlg = new IDDAcquireDBMeas(this); if (dbdlg.HasItems()) { dr = dbdlg.ShowDialog(); if (dr == DialogResult.OK) { Integ.BuildMeasurement(ap, det, mo); DateTimeOffset dto = dbdlg.measurementId.MeasDateTime; NC.App.Logger(LMLoggers.AppSection.App).TraceEvent(LogLevels.Info, 87654, "Using " + dto.ToString("MMM dd yyy HH:mm:ss.ff K")); NC.App.Opstate.Measurement.MeasDate = dto; // get the cycles for the selected measurement from the database, and add them to the current measurement CycleList cl = NC.App.DB.GetCycles(det, dbdlg.measurementId, ap.data_src); // APluralityOfMultiplicityAnalyzers: // URGENT: get all the cycles associated with each analzyer, restoring into the correct key->result pair NC.App.Opstate.Measurement.Add(cl); // use the cycle time interval as found in the data, taking the first entry because equal intervals are assumed if (cl.Count > 0) { NC.App.Opstate.Measurement.AcquireState.lm.Interval = NC.App.Opstate.Measurement.AcquireState.run_count_time = cl[0].TS.TotalSeconds; } NC.App.DB.UpdateAcquireParams(ap); //update it again } } else { MessageBox.Show("No items found in database matching these parameters", "WARNING"); } break; case ConstructedSource.Manual: UIIntegration.Controller.file = true; NC.App.AppContext.DBDataAssay = true; IDDManualDataEntry mdlg = new IDDManualDataEntry(); mdlg.AH = this; dr = mdlg.ShowDialog(); // the work constructing the measurement is done in the dialog class break; case ConstructedSource.Reanalysis: UIIntegration.Controller.file = true; NC.App.AppContext.DBDataAssay = true; dr = DialogResult.OK; // the measurement re-creation work is done in the IDDReanalysisAssay dialog class prior to reaching this point break; case ConstructedSource.CycleFile: Integ.BuildMeasurementMinimal(ap, det, mo); // the measurement is reconstructed before each test data file processing, so this is meant as a carrier for certain kick-off values NC.App.AppContext.TestDataFileAssay = true; UIIntegration.Controller.file = true; dr = UIIntegration.GetUsersFile("Select a test data (disk) file", NC.App.AppContext.FileInput, "INCC5 Test data (disk)", "dat", "cnn"); break; case ConstructedSource.ReviewFile: Integ.BuildMeasurementMinimal(ap, det, mo); // acquire type and measurement option are read from each NCC file itself, so this instance is an acquire state kick-off carrier value NC.App.AppContext.ReviewFileAssay = true; UIIntegration.Controller.file = true; dr = UIIntegration.GetUsersFile("Select an NCC file", NC.App.AppContext.FileInput, "INCC5 Review", "NCC"); break; case ConstructedSource.NCDFile: Integ.BuildMeasurement(ap, det, mo); NC.App.AppContext.NCDFileAssay = true; UIIntegration.Controller.file = true; if (det.ListMode || NC.App.Opstate.Measurement.MeasOption.IsListMode()) { dr = (new LMAcquire(ap, det, fromINCC5Acq: true)).ShowDialog(); // show LM-relevant acquire-style settings for modification or confirmation } else { dr = UIIntegration.GetUsersFilesFolder("Select NCD files or folder", NC.App.AppContext.FileInput, "LMMM NCD", "ncd"); } break; case ConstructedSource.SortedPulseTextFile: Integ.BuildMeasurement(ap, det, mo); NC.App.AppContext.PulseFileAssay = true; UIIntegration.Controller.file = true; if (det.ListMode || NC.App.Opstate.Measurement.MeasOption.IsListMode()) { dr = (new LMAcquire(ap, det, fromINCC5Acq: true)).ShowDialog(); // show LM-relevant acquire-style settings for modification or confirmation } else { dr = UIIntegration.GetUsersFilesFolder("Select pulse files or folder", NC.App.AppContext.FileInput, "pulse", "txt"); } break; case ConstructedSource.PTRFile: Integ.BuildMeasurement(ap, det, mo); NC.App.AppContext.PTRFileAssay = true; UIIntegration.Controller.file = true; if (det.ListMode || NC.App.Opstate.Measurement.MeasOption.IsListMode()) { dr = (new LMAcquire(ap, det, fromINCC5Acq: true)).ShowDialog(); // show LM-relevant acquire-style settings for modification or confirmation } else { dr = UIIntegration.GetUsersFilesFolder("Select PTR-32 files or folder", NC.App.AppContext.FileInput, "PTR-32", "bin", "chn"); } break; case ConstructedSource.MCA527File: Integ.BuildMeasurement(ap, det, mo); NC.App.AppContext.MCA527FileAssay = true; UIIntegration.Controller.file = true; if (det.ListMode || NC.App.Opstate.Measurement.MeasOption.IsListMode()) { dr = (new LMAcquire(ap, det, fromINCC5Acq: true)).ShowDialog(); // show LM-relevant acquire-style settings for modification or confirmation } else { dr = UIIntegration.GetUsersFilesFolder("Select MCA files or folder", NC.App.AppContext.FileInput, "MCA527", "mca"); } break; default: break; } return(dr); }
//// BUTTONCLICK HANDLERS /////////////////////////////////////////////// public DialogResult OKButton_Click(object sender, EventArgs e) { DialogResult dr = DialogResult.Cancel; if (ap.modified) { INCCDB.AcquireSelector sel = new INCCDB.AcquireSelector(det, ap.item_type, DateTime.Now); ap.MeasDateTime = sel.TimeStamp; ap.lm.TimeStamp = sel.TimeStamp; NC.App.DB.AcquireParametersMap().Add(sel, ap); // it's a new one, not the existing one modified NC.App.DB.UpdateAcquireParams(ap, det.ListMode); } // The acquire is set to occur, build up the measurement state AnalysisWizard.ResetMeasurement(); Integ.BuildMeasurement(ap, det, mo); switch (ap.data_src) { case ConstructedSource.Live: // set up the instrument list for the action controller UIIntegration.Controller.file = false; // make sure to use the DAQ controller, not the file controller NC.App.AppContext.FileInput = null; // reset the cmd line file input flag if (det.ListMode) { // patch override lm.Interval with run_count_time from dialog NC.App.Opstate.Measurement.AcquireState.lm.Interval = NC.App.Opstate.Measurement.AcquireState.run_count_time; // Check NC.App.Opstate.Measurement.AnalysisParams for at least one VSR // If not present, inform and pop up the wizard // If present, inform with new dialog, do not pop up the wizard if (NC.App.Opstate.Measurement.AnalysisParams.HasMultiplicity()) { dr = DialogResult.OK; } else { AnalysisWizard awl = new AnalysisWizard(AnalysisWizard.AWSteps.Step2B, ap, det); // analyzers are created in here, placed on global measurement dr = awl.ShowDialog(); if (dr == DialogResult.OK) { NC.App.DB.UpdateAcquireParams(ap); //update it again NC.App.DB.UpdateDetector(det); } } if (dr == DialogResult.OK) { // if ok, the analyzers are set up, so can kick it off now. UIIntegration.Controller.ActivateDetector(det); } } else { SRInstrument sri = new SRInstrument(det); sri.selected = true; sri.Init(NC.App.Loggers.Logger(LMLoggers.AppSection.Data), NC.App.Loggers.Logger(LMLoggers.AppSection.Analysis)); if (!Instruments.All.Contains(sri)) { Instruments.All.Add(sri); // add to global runtime list } dr = DialogResult.OK; } break; case ConstructedSource.DB: NC.App.AppContext.DBDataAssay = true; UIIntegration.Controller.file = true; IDDAcquireDBMeas dbdlg = new IDDAcquireDBMeas(this); if (dbdlg.HasItems()) { dr = dbdlg.ShowDialog(); if (dr == DialogResult.OK) { DateTimeOffset dto = dbdlg.measurementId.MeasDateTime; DateTimeOffset cur = new DateTimeOffset(dto.Ticks, dto.Offset); NC.App.Logger(NCCReporter.LMLoggers.AppSection.App).TraceEvent(NCCReporter.LogLevels.Info, 87654, "Using " + dto.ToString("MMM dd yyy HH:mm:ss.ff K")); // get the cycles for the selected measurement from the database, and add them to the current measurement CycleList cl = NC.App.DB.GetCycles(det, dbdlg.measurementId); foreach (Cycle cycle in cl) // add the necessary meta-data to the cycle identifier instance { cycle.UpdateDataSourceId(ap.data_src, det.Id.SRType, cur.AddTicks(cycle.TS.Ticks), det.Id.FileName); cur = cycle.DataSourceId.dt; } NC.App.Opstate.Measurement.Add(cl); // TODO: for Reanalysis, a full reconstruction of the measurement state based on the ResultsRec state and the method parameter map contents (for Calib and Verif) } } else { MessageBox.Show("No items found in database matching these parameters", "WARNING"); } break; case ConstructedSource.Manual: UIIntegration.Controller.file = true; NC.App.AppContext.DBDataAssay = true; IDDManualDataEntry mdlg = new IDDManualDataEntry(); mdlg.AH = this; dr = mdlg.ShowDialog(); if (dr == DialogResult.OK) { // the work is done in the dialog class } break; case ConstructedSource.CycleFile: NC.App.AppContext.TestDataFileAssay = true; UIIntegration.Controller.file = true; dr = UIIntegration.GetUsersFile("Select a test data (disk) file", NC.App.AppContext.FileInput, "INCC5 Test data (disk)", "dat"); break; case ConstructedSource.ReviewFile: NC.App.AppContext.ReviewFileAssay = true; UIIntegration.Controller.file = true; dr = UIIntegration.GetUsersFile("Select an NCC file", NC.App.AppContext.FileInput, "INCC5 Review", "NCC"); break; case ConstructedSource.NCDFile: NC.App.AppContext.NCDFileAssay = true; UIIntegration.Controller.file = true; if (NC.App.Opstate.Measurement.MeasOption == AssaySelector.MeasurementOption.unspecified) { AnalysisWizard aw = new AnalysisWizard(AnalysisWizard.AWSteps.Step2A, ap, det); dr = aw.ShowDialog(); // show LM-relevant acquire-style settings for modification or confirmation } else { dr = UIIntegration.GetUsersFilesFolder("Select NCD files or folder", NC.App.AppContext.FileInput, "LMMM NCD", "ncd"); } break; case ConstructedSource.SortedPulseTextFile: NC.App.AppContext.PulseFileAssay = true; UIIntegration.Controller.file = true; if (NC.App.Opstate.Measurement.MeasOption == AssaySelector.MeasurementOption.unspecified) { AnalysisWizard aw1 = new AnalysisWizard(AnalysisWizard.AWSteps.Step2A, ap, det); dr = aw1.ShowDialog(); // show LM-relevant acquire-style settings for modification or confirmation } else { dr = UIIntegration.GetUsersFilesFolder("Select pulse files or folder", NC.App.AppContext.FileInput, "pulse", "txt"); } break; case ConstructedSource.PTRFile: NC.App.AppContext.PTRFileAssay = true; UIIntegration.Controller.file = true; if (NC.App.Opstate.Measurement.MeasOption == AssaySelector.MeasurementOption.unspecified) { AnalysisWizard aw2 = new AnalysisWizard(AnalysisWizard.AWSteps.Step2A, ap, det); dr = aw2.ShowDialog(); // show LM-relevant acquire-style settings for modification or confirmation } else { dr = UIIntegration.GetUsersFilesFolder("Select PTR-32 files or folder", NC.App.AppContext.FileInput, "PTR-32", "bin", "chn"); } break; case ConstructedSource.NILAFile: NC.App.AppContext.NILAFileAssay = true; UIIntegration.Controller.file = true; dr = UIIntegration.GetUsersFilesFolder("Select NILA files or folder", NC.App.AppContext.FileInput, "MTS NILA", "dat"); //dr = DialogResult.Cancel; break; default: break; } return(dr); }
//// BUTTONCLICK HANDLERS /////////////////////////////////////////////// public DialogResult OKButton_Click(object sender, EventArgs e) { DialogResult dr = DialogResult.Cancel; if (ap.modified) { INCCDB.AcquireSelector sel = new INCCDB.AcquireSelector(det, ap.item_type, DateTime.Now); ap.MeasDateTime = sel.TimeStamp; ap.lm.TimeStamp = sel.TimeStamp; NC.App.DB.AddAcquireParams(sel, ap); // it's a new one, not the existing one modified } // The acquire is set to occur if (ap.data_src != ConstructedSource.Reanalysis) // Reanalysis is a bit backwards, the correct measurement is fully constructed before this point LMAcquire.ResetMeasurement(); switch (ap.data_src) { case ConstructedSource.Live: // set up the instrument list for the action controller Integ.BuildMeasurement(ap, det, mo); UIIntegration.Controller.file = false; // make sure to use the DAQ controller, not the file controller NC.App.AppContext.FileInput = null; // reset the cmd line file input flag if (det.ListMode) { // patch override lm.Interval with run_count_time from dialog // the acquire dialogs field values, as seen and modified by the user, override the LM-only acquire settings for virtual SR measurements NC.App.Opstate.Measurement.AcquireState.lm.Interval = NC.App.Opstate.Measurement.AcquireState.run_count_time; NC.App.Opstate.Measurement.AcquireState.lm.Cycles = NC.App.Opstate.Measurement.AcquireState.num_runs; // Check NC.App.Opstate.Measurement.AnalysisParams for at least one VSR // If not present, inform and pop up the wizard // If present, inform with new dialog, do not pop up the wizard if (NC.App.Opstate.Measurement.AnalysisParams.HasMatchingVSR(det.MultiplicityParams)) { dr = DialogResult.OK; } else { dr = (new LMAcquire(ap, det, fromINCC5Acq: true)).ShowDialog();// analyzers are created in here, placed on global measurement if (dr == DialogResult.OK) { NC.App.DB.UpdateAcquireParams(ap); //update it again NC.App.DB.UpdateDetector(det); } } if (dr == DialogResult.OK) { // if ok, the analyzers are set up, so can kick it off now. UIIntegration.Controller.ActivateDetector(det); } } else { SRInstrument sri = new SRInstrument(det); sri.selected = true; sri.Init(NC.App.Loggers.Logger(LMLoggers.AppSection.Data), NC.App.Loggers.Logger(LMLoggers.AppSection.Analysis)); if (!Instruments.All.Contains(sri)) Instruments.All.Add(sri); // add to global runtime list dr = DialogResult.OK; } break; case ConstructedSource.DB: NC.App.AppContext.DBDataAssay = true; UIIntegration.Controller.file = true; IDDAcquireDBMeas dbdlg = new IDDAcquireDBMeas(this); if (dbdlg.HasItems()) { dr = dbdlg.ShowDialog(); if (dr == DialogResult.OK) { Integ.BuildMeasurement(ap, det, mo); DateTimeOffset dto = dbdlg.measurementId.MeasDateTime; NC.App.Logger(LMLoggers.AppSection.App).TraceEvent(LogLevels.Info, 87654, "Using " + dto.ToString("MMM dd yyy HH:mm:ss.ff K")); NC.App.Opstate.Measurement.MeasDate = dto; // get the cycles for the selected measurement from the database, and add them to the current measurement CycleList cl = NC.App.DB.GetCycles(det, dbdlg.measurementId, ap.data_src); // APluralityOfMultiplicityAnalyzers: // URGENT: get all the cycles associated with each analyzer, restoring into the correct key->result pair NC.App.Opstate.Measurement.Add(cl); // use the cycle time interval as found in the data, taking the first entry because equal intervals are assumed if (cl.Count > 0) NC.App.Opstate.Measurement.AcquireState.lm.Interval = NC.App.Opstate.Measurement.AcquireState.run_count_time = cl[0].TS.TotalSeconds; NC.App.DB.UpdateAcquireParams(ap); //update it again } } else MessageBox.Show("No items found in database matching these parameters", "WARNING"); break; case ConstructedSource.Manual: UIIntegration.Controller.file = true; NC.App.AppContext.DBDataAssay = true; IDDManualDataEntry mdlg = new IDDManualDataEntry(); mdlg.AH = this; dr = mdlg.ShowDialog(); // the work constructing the measurement is done in the dialog class break; case ConstructedSource.Reanalysis: UIIntegration.Controller.file = true; NC.App.AppContext.DBDataAssay = true; dr = DialogResult.OK; // the measurement re-creation work is done in the IDDReanalysisAssay dialog class prior to reaching this point break; case ConstructedSource.CycleFile: Integ.BuildMeasurementMinimal(ap, det, mo); // the measurement is reconstructed before each test data file processing, so this is meant as a carrier for certain kick-off values NC.App.AppContext.TestDataFileAssay = true; UIIntegration.Controller.file = true; dr = UIIntegration.GetUsersFile("Select a test data (disk) file", NC.App.AppContext.FileInput, "INCC5 Test data (disk)", "dat", "cnn"); break; case ConstructedSource.ReviewFile: Integ.BuildMeasurementMinimal(ap, det, mo); // acquire type and measurement option are read from each NCC file itself, so this instance is an acquire state kick-off carrier value NC.App.AppContext.ReviewFileAssay = true; UIIntegration.Controller.file = true; dr = UIIntegration.GetUsersFile("Select an NCC file", NC.App.AppContext.FileInput, "INCC5 Review", "NCC"); break; case ConstructedSource.NCDFile: Integ.BuildMeasurement(ap, det, mo); NC.App.AppContext.NCDFileAssay = true; UIIntegration.Controller.file = true; if (det.ListMode || NC.App.Opstate.Measurement.MeasOption.IsListMode()) { dr = (new LMAcquire(ap, det, fromINCC5Acq: true)).ShowDialog(); // show LM-relevant acquire-style settings for modification or confirmation } else { dr = UIIntegration.GetUsersFilesFolder("Select NCD files or folder", NC.App.AppContext.FileInput, "LMMM NCD", "ncd"); } break; case ConstructedSource.SortedPulseTextFile: Integ.BuildMeasurement(ap, det, mo); NC.App.AppContext.PulseFileAssay = true; UIIntegration.Controller.file = true; if (det.ListMode || NC.App.Opstate.Measurement.MeasOption.IsListMode()) { dr = (new LMAcquire(ap, det, fromINCC5Acq: true)).ShowDialog(); // show LM-relevant acquire-style settings for modification or confirmation } else { dr = UIIntegration.GetUsersFilesFolder("Select pulse files or folder", NC.App.AppContext.FileInput, "pulse", "txt"); } break; case ConstructedSource.PTRFile: Integ.BuildMeasurement(ap, det, mo); NC.App.AppContext.PTRFileAssay = true; UIIntegration.Controller.file = true; if (det.ListMode || NC.App.Opstate.Measurement.MeasOption.IsListMode()) { dr = (new LMAcquire(ap, det, fromINCC5Acq: true)).ShowDialog(); // show LM-relevant acquire-style settings for modification or confirmation } else { dr = UIIntegration.GetUsersFilesFolder("Select PTR-32 files or folder", NC.App.AppContext.FileInput, "PTR-32", "bin", "chn"); } break; case ConstructedSource.MCA527File: Integ.BuildMeasurement(ap, det, mo); NC.App.AppContext.MCA527FileAssay = true; UIIntegration.Controller.file = true; if (det.ListMode || NC.App.Opstate.Measurement.MeasOption.IsListMode()) { dr = (new LMAcquire(ap, det, fromINCC5Acq: true)).ShowDialog(); // show LM-relevant acquire-style settings for modification or confirmation } else { dr = UIIntegration.GetUsersFilesFolder("Select MCA files or folder", NC.App.AppContext.FileInput, "MCA527", "mca"); } break; default: break; } return dr; }
//// BUTTONCLICK HANDLERS /////////////////////////////////////////////// public DialogResult OKButton_Click(object sender, EventArgs e) { DialogResult dr = DialogResult.Cancel; if (ap.modified) { INCCDB.AcquireSelector sel = new INCCDB.AcquireSelector(det, ap.item_type, DateTime.Now); ap.MeasDateTime = sel.TimeStamp; ap.lm.TimeStamp = sel.TimeStamp; NC.App.DB.AcquireParametersMap().Add(sel, ap); // it's a new one, not the existing one modified NC.App.DB.UpdateAcquireParams(ap, det.ListMode); } // The acquire is set to occur, build up the measurement state AnalysisWizard.ResetMeasurement(); Integ.BuildMeasurement(ap, det, mo); switch (ap.data_src) { case ConstructedSource.Live: // set up the instrument list for the action controller UIIntegration.Controller.file = false; // make sure to use the DAQ controller, not the file controller NC.App.AppContext.FileInput = null; // reset the cmd line file input flag if (det.ListMode) { // patch override lm.Interval with run_count_time from dialog NC.App.Opstate.Measurement.AcquireState.lm.Interval = NC.App.Opstate.Measurement.AcquireState.run_count_time; // Check NC.App.Opstate.Measurement.AnalysisParams for at least one VSR // If not present, inform and pop up the wizard // If present, inform with new dialog, do not pop up the wizard if (NC.App.Opstate.Measurement.AnalysisParams.HasMultiplicity()) { dr = DialogResult.OK; } else { AnalysisWizard awl = new AnalysisWizard(AnalysisWizard.AWSteps.Step2B, ap, det); // analyzers are created in here, placed on global measurement dr = awl.ShowDialog(); if (dr == DialogResult.OK) { NC.App.DB.UpdateAcquireParams(ap); //update it again NC.App.DB.UpdateDetector(det); } } if (dr == DialogResult.OK) { // if ok, the analyzers are set up, so can kick it off now. UIIntegration.Controller.ActivateDetector(det); } } else { SRInstrument sri = new SRInstrument(det); sri.selected = true; sri.Init(NC.App.Loggers.Logger(LMLoggers.AppSection.Data), NC.App.Loggers.Logger(LMLoggers.AppSection.Analysis)); if (!Instruments.All.Contains(sri)) Instruments.All.Add(sri); // add to global runtime list dr = DialogResult.OK; } break; case ConstructedSource.DB: NC.App.AppContext.DBDataAssay = true; UIIntegration.Controller.file = true; IDDAcquireDBMeas dbdlg = new IDDAcquireDBMeas(this); if (dbdlg.HasItems()) { dr = dbdlg.ShowDialog(); if (dr == DialogResult.OK) { DateTimeOffset dto = dbdlg.measurementId.MeasDateTime; DateTimeOffset cur = new DateTimeOffset(dto.Ticks, dto.Offset); NC.App.Logger(NCCReporter.LMLoggers.AppSection.App).TraceEvent(NCCReporter.LogLevels.Info, 87654, "Using " + dto.ToString("MMM dd yyy HH:mm:ss.ff K")); // get the cycles for the selected measurement from the database, and add them to the current measurement CycleList cl = NC.App.DB.GetCycles(det, dbdlg.measurementId); foreach(Cycle cycle in cl) // add the necessary meta-data to the cycle identifier instance { cycle.UpdateDataSourceId(ap.data_src, det.Id.SRType, cur.AddTicks(cycle.TS.Ticks), det.Id.FileName); cur = cycle.DataSourceId.dt; } NC.App.Opstate.Measurement.Add(cl); // TODO: for Reanalysis, a full reconstruction of the measurement state based on the ResultsRec state and the method parameter map contents (for Calib and Verif) } } else MessageBox.Show("No items found in database matching these parameters", "WARNING"); break; case ConstructedSource.Manual: UIIntegration.Controller.file = true; NC.App.AppContext.DBDataAssay = true; IDDManualDataEntry mdlg = new IDDManualDataEntry(); mdlg.AH = this; dr = mdlg.ShowDialog(); if (dr == DialogResult.OK) { // the work is done in the dialog class } break; case ConstructedSource.CycleFile: NC.App.AppContext.TestDataFileAssay = true; UIIntegration.Controller.file = true; dr = UIIntegration.GetUsersFile("Select a test data (disk) file", NC.App.AppContext.FileInput, "INCC5 Test data (disk)", "dat"); break; case ConstructedSource.ReviewFile: NC.App.AppContext.ReviewFileAssay = true; UIIntegration.Controller.file = true; dr = UIIntegration.GetUsersFile("Select an NCC file", NC.App.AppContext.FileInput, "INCC5 Review", "NCC"); break; case ConstructedSource.NCDFile: NC.App.AppContext.NCDFileAssay = true; UIIntegration.Controller.file = true; if (NC.App.Opstate.Measurement.MeasOption == AssaySelector.MeasurementOption.unspecified) { AnalysisWizard aw = new AnalysisWizard(AnalysisWizard.AWSteps.Step2A, ap, det); dr = aw.ShowDialog(); // show LM-relevant acquire-style settings for modification or confirmation } else { dr = UIIntegration.GetUsersFilesFolder("Select NCD files or folder", NC.App.AppContext.FileInput, "LMMM NCD", "ncd"); } break; case ConstructedSource.SortedPulseTextFile: NC.App.AppContext.PulseFileAssay = true; UIIntegration.Controller.file = true; if (NC.App.Opstate.Measurement.MeasOption == AssaySelector.MeasurementOption.unspecified) { AnalysisWizard aw1 = new AnalysisWizard(AnalysisWizard.AWSteps.Step2A, ap, det); dr = aw1.ShowDialog(); // show LM-relevant acquire-style settings for modification or confirmation } else { dr = UIIntegration.GetUsersFilesFolder("Select pulse files or folder", NC.App.AppContext.FileInput, "pulse", "txt"); } break; case ConstructedSource.PTRFile: NC.App.AppContext.PTRFileAssay = true; UIIntegration.Controller.file = true; if (NC.App.Opstate.Measurement.MeasOption == AssaySelector.MeasurementOption.unspecified) { AnalysisWizard aw2 = new AnalysisWizard(AnalysisWizard.AWSteps.Step2A, ap, det); dr = aw2.ShowDialog(); // show LM-relevant acquire-style settings for modification or confirmation } else { dr = UIIntegration.GetUsersFilesFolder("Select PTR-32 files or folder", NC.App.AppContext.FileInput, "PTR-32", "bin", "chn"); } break; case ConstructedSource.NILAFile: NC.App.AppContext.NILAFileAssay = true; UIIntegration.Controller.file = true; dr = UIIntegration.GetUsersFilesFolder("Select NILA files or folder", NC.App.AppContext.FileInput, "MTS NILA", "dat"); //dr = DialogResult.Cancel; break; default: break; } return dr; }