public static EnergyValue Parse(byte[] message) { ZWaveValue zvalue = ZWaveValue.ExtractValueFromBytes(message, 11); EnergyValue energy = new EnergyValue(); //energy.Value = ((double)int.Parse( // message[12].ToString("X2") + message[13].ToString("X2") + message[14].ToString("X2"), // System.Globalization.NumberStyles.HexNumber // )) / 1000D; energy.Value = zvalue.Value; if (Enum.IsDefined(typeof(ZWaveEnergyScaleType), zvalue.Scale)) { energy.Parameter = (ZWaveEnergyScaleType)zvalue.Scale; } switch (energy.Parameter) { // Accumulated power consumption kW/h case ZWaveEnergyScaleType.kWh: energy.EventType = EventParameter.MeterKwHour; break; // Accumulated power consumption kilo Volt Ampere / hours (kVA/h) case ZWaveEnergyScaleType.kVAh: energy.EventType = EventParameter.MeterKvaHour; break; // Instant power consumption Watt case ZWaveEnergyScaleType.Watt: energy.EventType = EventParameter.MeterWatt; break; // Pulses count case ZWaveEnergyScaleType.Pulses: energy.EventType = EventParameter.MeterPulses; break; // AC load Voltage case ZWaveEnergyScaleType.ACVolt: energy.EventType = EventParameter.MeterAcVolt; break; // AC load Current case ZWaveEnergyScaleType.ACCurrent: energy.EventType = EventParameter.MeterAcCurrent; break; // Power Factor case ZWaveEnergyScaleType.PowerFactor: energy.EventType = EventParameter.MeterPower; break; default: energy.EventType = EventParameter.MeterWatt; break; } return(energy); }
public static SensorValue Parse(byte[] message) { SensorValue sensor = new SensorValue(); // ZWaveValue zvalue = ZWaveValue.ExtractValueFromBytes(message, 11); // byte key = message[9]; if (key == (byte)ZWaveSensorParameter.Temperature) { sensor.Parameter = ZWaveSensorParameter.Temperature; // convert from Fahrenheit to Celsius if needed sensor.Value = (zvalue.Scale == (int)ZWaveTemperatureScaleType.Fahrenheit ? SensorValue.FahrenheitToCelsius(zvalue.Value) : zvalue.Value); sensor.EventType = EventParameter.SensorTemperature; } else if (key == (byte)ZWaveSensorParameter.GeneralPurposeValue) { sensor.Parameter = ZWaveSensorParameter.GeneralPurposeValue; sensor.Value = zvalue.Value; sensor.EventType = EventParameter.Generic; } else if (key == (byte)ZWaveSensorParameter.Luminance) { sensor.Parameter = ZWaveSensorParameter.Luminance; sensor.Value = zvalue.Value; sensor.EventType = EventParameter.SensorLuminance; } else if (key == (byte)ZWaveSensorParameter.RelativeHumidity) { sensor.Parameter = ZWaveSensorParameter.RelativeHumidity; sensor.Value = zvalue.Value; sensor.EventType = EventParameter.SensorHumidity; } else if (key == (byte)ZWaveSensorParameter.Power) { //sensor.Value = BitConverter.ToUInt16(new byte[2] { message[12], message[11] }, 0) / 10D; //sensor.Value = ((double)int.Parse( // message[12].ToString("X2") + message[13].ToString("X2") + message[14].ToString("X2"), // System.Globalization.NumberStyles.HexNumber // )) / 1000D; // TODO: this might be very buggy.... to be tested EnergyValue energy = EnergyValue.Parse(message); sensor.Parameter = ZWaveSensorParameter.Power; sensor.Value = energy.Value; sensor.EventType = EventParameter.MeterPower; } else { sensor.Value = zvalue.Value; } // return(sensor); }
public static EnergyValue Parse(byte[] message) { ZWaveValue zvalue = ZWaveValue.ExtractValueFromBytes(message, 4); //int meterType = (message[1] & 0x1f); //Utility.logger.Warn("METER TYPE ({0})!", meterType); EnergyValue energy = new EnergyValue(); energy.Value = zvalue.Value; if (Enum.IsDefined(typeof(ZWaveEnergyScaleType), zvalue.Scale)) { energy.Parameter = (ZWaveEnergyScaleType)zvalue.Scale; } else { Utility.logger.Warn("Undefined Energy Meter Scale Type {0}!", zvalue.Scale); } // sometimes it appears this odd extra bit 0x80 (128) in message[2] // when scale type should be power factor it is interpreted as watt // (it happens with Qbino smart meter) // the following is a temporary work-around for that // TODO: find out the meaning of message[2] = 0xA1 (in place of 0x21) if ((message[2] & 0x80) == 0x80 && energy.Parameter == ZWaveEnergyScaleType.Watt) { energy.Parameter = ZWaveEnergyScaleType.PowerFactor; } switch (energy.Parameter) { // Accumulated power consumption kW/h case ZWaveEnergyScaleType.kWh: energy.EventType = EventParameter.MeterKwHour; break; // Accumulated power consumption kilo Volt Ampere / hours (kVA/h) case ZWaveEnergyScaleType.kVAh: energy.EventType = EventParameter.MeterKvaHour; break; // Instant power consumption Watt case ZWaveEnergyScaleType.Watt: energy.EventType = EventParameter.MeterWatt; break; // Pulses count case ZWaveEnergyScaleType.Pulses: energy.EventType = EventParameter.MeterPulses; break; // AC load Voltage case ZWaveEnergyScaleType.ACVolt: energy.EventType = EventParameter.MeterAcVolt; break; // AC load Current case ZWaveEnergyScaleType.ACCurrent: energy.EventType = EventParameter.MeterAcCurrent; break; // Power Factor case ZWaveEnergyScaleType.PowerFactor: energy.EventType = EventParameter.MeterPower; break; default: // Unknown value ? energy = null; break; } return(energy); }
public static SensorValue Parse(byte[] message) { var zvalue = ZWaveValue.ExtractValueFromBytes(message, 4); var sensorType = ZWaveSensorParameter.Unknown; if (Enum.IsDefined(typeof(ZWaveSensorParameter), (int)message[2])) { sensorType = (ZWaveSensorParameter)message[2]; } var sensorValue = new SensorValue { Parameter = sensorType, Value = zvalue.Value }; switch (sensorType) { case ZWaveSensorParameter.Temperature: // convert from Fahrenheit to Celsius if needed sensorValue.Value = zvalue.Scale == (int)ZWaveTemperatureScaleType.Fahrenheit ? FahrenheitToCelsius(zvalue.Value) : zvalue.Value; sensorValue.EventType = EventParameter.SensorTemperature; break; case ZWaveSensorParameter.GeneralPurposeValue: sensorValue.EventType = EventParameter.SensorGeneric; break; case ZWaveSensorParameter.Luminance: sensorValue.EventType = EventParameter.SensorLuminance; break; case ZWaveSensorParameter.RelativeHumidity: sensorValue.EventType = EventParameter.SensorHumidity; break; case ZWaveSensorParameter.Power: //sensor.Value = BitConverter.ToUInt16(new byte[2] { message[12], message[11] }, 0) / 10D; //sensor.Value = ((double)int.Parse( // message[12].ToString("X2") + message[13].ToString("X2") + message[14].ToString("X2"), // System.Globalization.NumberStyles.HexNumber // )) / 1000D; // TODO: this might be very buggy.... to be tested EnergyValue energy = EnergyValue.Parse(message); sensorValue.Value = energy.Value; sensorValue.EventType = EventParameter.MeterPower; break; case ZWaveSensorParameter.WaterFlow: sensorValue.EventType = EventParameter.WaterFlow; break; case ZWaveSensorParameter.WaterPressure: sensorValue.EventType = EventParameter.WaterPressure; break; case ZWaveSensorParameter.Ultraviolet: sensorValue.EventType = EventParameter.Ultraviolet; break; // TODO: implement other Sensor Types } return(sensorValue); }
public static EnergyValue Parse(byte[] message) { ZWaveValue zvalue = ZWaveValue.ExtractValueFromBytes(message, 4); EnergyValue energy = new EnergyValue(); energy.Value = zvalue.Value; if (Enum.IsDefined(typeof(ZWaveEnergyScaleType), zvalue.Scale)) { energy.Parameter = (ZWaveEnergyScaleType)zvalue.Scale; } switch (energy.Parameter) { // Accumulated power consumption kW/h case ZWaveEnergyScaleType.kWh: //energy.EventType = EventParameter.MeterKwHour; // TODO: The following is fix for for AeonLabs HEM G2 // TODO: https://github.com/genielabs/HomeGenie/pull/186 // TODO: possibly move this fix to ZWaveValue.ExtractValueFromBytes method if ((message[2] & 0x80) == 0x80) { energy.EventType = EventParameter.MeterAcVolt; } else { energy.EventType = EventParameter.MeterKwHour; } break; // Accumulated power consumption kilo Volt Ampere / hours (kVA/h) case ZWaveEnergyScaleType.kVAh: energy.EventType = EventParameter.MeterKvaHour; break; // Instant power consumption Watt case ZWaveEnergyScaleType.Watt: energy.EventType = EventParameter.MeterWatt; break; // Pulses count case ZWaveEnergyScaleType.Pulses: energy.EventType = EventParameter.MeterPulses; break; // AC load Voltage case ZWaveEnergyScaleType.ACVolt: energy.EventType = EventParameter.MeterAcVolt; break; // AC load Current case ZWaveEnergyScaleType.ACCurrent: energy.EventType = EventParameter.MeterAcCurrent; break; // Power Factor case ZWaveEnergyScaleType.PowerFactor: energy.EventType = EventParameter.MeterPower; break; default: energy.EventType = EventParameter.MeterWatt; break; } return(energy); }