Exemple #1
0
        ///    <summary>
        ///       This method uses to add data to PRO_WCCapacity
        ///    </summary>
        ///    <Inputs>
        ///        PRO_WCCapacityVO
        ///    </Inputs>
        ///    <Returns>
        ///       void
        ///    </Returns>
        ///    <History>
        ///       Friday, August 12, 2005
        ///    </History>

        public object GetObjectVO(int pintID)
        {
            const string METHOD_NAME = THIS + ".GetObjectVO()";
            DataSet      dstPCS      = new DataSet();

            OleDbDataReader odrPCS  = null;
            OleDbConnection oconPCS = null;
            OleDbCommand    ocmdPCS = null;

            try
            {
                string strSql = String.Empty;
                strSql = "SELECT "
                         + PRO_WCCapacityTable.WCCAPACITYID_FLD + ","
                         + PRO_WCCapacityTable.MACHINENO_FLD + ","
                         + PRO_WCCapacityTable.BEGINDATE_FLD + ","
                         + PRO_WCCapacityTable.ENDDATE_FLD + ","
                         + PRO_WCCapacityTable.FACTOR_FLD + ","
                         + PRO_WCCapacityTable.CAPACITY_FLD + ","
                         + PRO_WCCapacityTable.CREWSIZE_FLD + ","
                         + PRO_WCCapacityTable.CCNID_FLD + ","
                         + PRO_WCCapacityTable.WCTYPE_FLD + ","
                         + PRO_WCCapacityTable.WORKCENTERID_FLD
                         + " FROM " + PRO_WCCapacityTable.TABLE_NAME
                         + " WHERE " + PRO_WCCapacityTable.WCCAPACITYID_FLD + "=" + pintID;

                Utils utils = new Utils();
                oconPCS = new OleDbConnection(Utils.Instance.OleDbConnectionString);
                ocmdPCS = new OleDbCommand(strSql, oconPCS);

                ocmdPCS.Connection.Open();
                odrPCS = ocmdPCS.ExecuteReader();

                PRO_WCCapacityVO objObject = new PRO_WCCapacityVO();

                while (odrPCS.Read())
                {
                    objObject.WCCapacityID = int.Parse(odrPCS[PRO_WCCapacityTable.WCCAPACITYID_FLD].ToString().Trim());
                    objObject.BeginDate    = DateTime.Parse(odrPCS[PRO_WCCapacityTable.BEGINDATE_FLD].ToString().Trim());
                    objObject.EndDate      = DateTime.Parse(odrPCS[PRO_WCCapacityTable.ENDDATE_FLD].ToString().Trim());
                    objObject.Factor       = Decimal.Parse(odrPCS[PRO_WCCapacityTable.FACTOR_FLD].ToString().Trim());
                    objObject.Capacity     = Decimal.Parse(odrPCS[PRO_WCCapacityTable.CAPACITY_FLD].ToString().Trim());
                    if (!odrPCS[PRO_WCCapacityTable.MACHINENO_FLD].Equals(DBNull.Value))
                    {
                        objObject.MachineNo = int.Parse(odrPCS[PRO_WCCapacityTable.MACHINENO_FLD].ToString().Trim());
                    }
                    else
                    {
                        objObject.MachineNo = Int32.MinValue;
                    }

                    if (!odrPCS[PRO_WCCapacityTable.CREWSIZE_FLD].Equals(DBNull.Value))
                    {
                        objObject.CrewSize = Decimal.Parse(odrPCS[PRO_WCCapacityTable.CREWSIZE_FLD].ToString().Trim());
                    }
                    else
                    {
                        objObject.CrewSize = Decimal.MinusOne;
                    }
                    objObject.CCNID        = int.Parse(odrPCS[PRO_WCCapacityTable.CCNID_FLD].ToString().Trim());
                    objObject.WCType       = int.Parse(odrPCS[PRO_WCCapacityTable.WCTYPE_FLD].ToString().Trim());
                    objObject.WorkCenterID = int.Parse(odrPCS[PRO_WCCapacityTable.WORKCENTERID_FLD].ToString().Trim());
                }

                return(objObject);
            }
            catch (OleDbException ex)
            {
                throw new PCSDBException(ErrorCode.ERROR_DB, METHOD_NAME, ex);
            }

            catch (Exception ex)
            {
                throw new PCSDBException(ErrorCode.OTHER_ERROR, METHOD_NAME, ex);
            }

            finally
            {
                if (oconPCS != null)
                {
                    if (oconPCS.State != ConnectionState.Closed)
                    {
                        oconPCS.Close();
                    }
                }
            }
        }
Exemple #2
0
        ///    <summary>
        ///       This method uses to add data to PRO_WCCapacity
        ///    </summary>
        ///    <Inputs>
        ///        PRO_WCCapacityVO
        ///    </Inputs>
        ///    <Returns>
        ///       void
        ///    </Returns>
        ///    <History>
        ///       Friday, August 12, 2005
        ///    </History>


        public void Update(object pobjObjecVO)
        {
            const string METHOD_NAME = THIS + ".Update()";

            PRO_WCCapacityVO objObject = (PRO_WCCapacityVO)pobjObjecVO;


            //prepare value for parameters
            OleDbConnection oconPCS = null;
            OleDbCommand    ocmdPCS = null;

            try
            {
                string strSql = String.Empty;
                Utils  utils  = new Utils();
                oconPCS = new OleDbConnection(Utils.Instance.OleDbConnectionString);
                ocmdPCS = new OleDbCommand(strSql, oconPCS);
                strSql  = "UPDATE PRO_WCCapacity SET "
                          + PRO_WCCapacityTable.MACHINENO_FLD + "=   ?" + ","
                          + PRO_WCCapacityTable.BEGINDATE_FLD + "=   ?" + ","
                          + PRO_WCCapacityTable.ENDDATE_FLD + "=   ?" + ","
                          + PRO_WCCapacityTable.FACTOR_FLD + "=   ?" + ","
                          + PRO_WCCapacityTable.CAPACITY_FLD + "=   ?" + ","
                          + PRO_WCCapacityTable.CREWSIZE_FLD + "=   ?" + ","
                          + PRO_WCCapacityTable.CCNID_FLD + "=   ?" + ","
                          + PRO_WCCapacityTable.WCTYPE_FLD + "=   ?" + ","
                          + PRO_WCCapacityTable.WORKCENTERID_FLD + "=  ?"
                          + " WHERE " + PRO_WCCapacityTable.WCCAPACITYID_FLD + "= ?";

                ocmdPCS.Parameters.Add(new OleDbParameter(PRO_WCCapacityTable.MACHINENO_FLD, OleDbType.Integer));
                if (objObject.MachineNo != Int32.MinValue)
                {
                    ocmdPCS.Parameters[PRO_WCCapacityTable.MACHINENO_FLD].Value = objObject.MachineNo;
                }
                else
                {
                    ocmdPCS.Parameters[PRO_WCCapacityTable.MACHINENO_FLD].Value = DBNull.Value;
                }

                ocmdPCS.Parameters.Add(new OleDbParameter(PRO_WCCapacityTable.BEGINDATE_FLD, OleDbType.Date));
                ocmdPCS.Parameters[PRO_WCCapacityTable.BEGINDATE_FLD].Value = objObject.BeginDate;

                ocmdPCS.Parameters.Add(new OleDbParameter(PRO_WCCapacityTable.ENDDATE_FLD, OleDbType.Date));
                ocmdPCS.Parameters[PRO_WCCapacityTable.ENDDATE_FLD].Value = objObject.EndDate;

                ocmdPCS.Parameters.Add(new OleDbParameter(PRO_WCCapacityTable.FACTOR_FLD, OleDbType.Decimal));
                ocmdPCS.Parameters[PRO_WCCapacityTable.FACTOR_FLD].Value = objObject.Factor;

                ocmdPCS.Parameters.Add(new OleDbParameter(PRO_WCCapacityTable.CAPACITY_FLD, OleDbType.Decimal));
                ocmdPCS.Parameters[PRO_WCCapacityTable.CAPACITY_FLD].Value = objObject.Capacity;

                ocmdPCS.Parameters.Add(new OleDbParameter(PRO_WCCapacityTable.CREWSIZE_FLD, OleDbType.Decimal));
                if (objObject.CrewSize != Decimal.MinusOne)
                {
                    ocmdPCS.Parameters[PRO_WCCapacityTable.CREWSIZE_FLD].Value = objObject.CrewSize;
                }
                else
                {
                    ocmdPCS.Parameters[PRO_WCCapacityTable.CREWSIZE_FLD].Value = DBNull.Value;
                }

                ocmdPCS.Parameters.Add(new OleDbParameter(PRO_WCCapacityTable.CCNID_FLD, OleDbType.Integer));
                ocmdPCS.Parameters[PRO_WCCapacityTable.CCNID_FLD].Value = objObject.CCNID;

                ocmdPCS.Parameters.Add(new OleDbParameter(PRO_WCCapacityTable.WCTYPE_FLD, OleDbType.Integer));
                ocmdPCS.Parameters[PRO_WCCapacityTable.WCTYPE_FLD].Value = objObject.WCType;

                ocmdPCS.Parameters.Add(new OleDbParameter(PRO_WCCapacityTable.WORKCENTERID_FLD, OleDbType.Integer));
                ocmdPCS.Parameters[PRO_WCCapacityTable.WORKCENTERID_FLD].Value = objObject.WorkCenterID;

                ocmdPCS.Parameters.Add(new OleDbParameter(PRO_WCCapacityTable.WCCAPACITYID_FLD, OleDbType.Integer));
                ocmdPCS.Parameters[PRO_WCCapacityTable.WCCAPACITYID_FLD].Value = objObject.WCCapacityID;

                ocmdPCS.CommandText = strSql;
                ocmdPCS.Connection.Open();
                ocmdPCS.ExecuteNonQuery();
            }
            catch (OleDbException ex)
            {
                if (ex.Errors[1].NativeError == ErrorCode.SQLDUPLICATE_KEYCODE)
                {
                    throw new PCSDBException(ErrorCode.DUPLICATE_KEY, METHOD_NAME, ex);
                }
                else
                {
                    throw new PCSDBException(ErrorCode.ERROR_DB, METHOD_NAME, ex);
                }
            }

            catch (InvalidOperationException ex)
            {
                throw new PCSDBException(ErrorCode.ERROR_DB, METHOD_NAME, ex);
            }
            catch (Exception ex)
            {
                throw new PCSDBException(ErrorCode.OTHER_ERROR, METHOD_NAME, ex);
            }

            finally
            {
                if (oconPCS != null)
                {
                    if (oconPCS.State != ConnectionState.Closed)
                    {
                        oconPCS.Close();
                    }
                }
            }
        }
Exemple #3
0
        public int AddAndReturnId(object pobjObjectVO)
        {
            const string METHOD_NAME = THIS + ".AddAndReturnId()";

            OleDbConnection oconPCS = null;
            OleDbCommand    ocmdPCS = null;

            try
            {
                PRO_WCCapacityVO objObject = (PRO_WCCapacityVO)pobjObjectVO;

                Utils utils = new Utils();
                oconPCS = new OleDbConnection(Utils.Instance.OleDbConnectionString);

                string strSql = "INSERT INTO PRO_WCCapacity("
                                + PRO_WCCapacityTable.MACHINENO_FLD + ","
                                + PRO_WCCapacityTable.BEGINDATE_FLD + ","
                                + PRO_WCCapacityTable.ENDDATE_FLD + ","
                                + PRO_WCCapacityTable.FACTOR_FLD + ","
                                + PRO_WCCapacityTable.CAPACITY_FLD + ","
                                + PRO_WCCapacityTable.CREWSIZE_FLD + ","
                                + PRO_WCCapacityTable.CCNID_FLD + ","
                                + PRO_WCCapacityTable.WCTYPE_FLD + ","
                                + PRO_WCCapacityTable.WORKCENTERID_FLD + ")"
                                + "VALUES(?,?,?,?,?,?,?,?,?)"
                                + "; SELECT @@IDENTITY as LatestID";

                ocmdPCS = new OleDbCommand(strSql, oconPCS);

                ocmdPCS.Parameters.Add(new OleDbParameter(PRO_WCCapacityTable.MACHINENO_FLD, OleDbType.Integer));
                if (objObject.MachineNo != Int32.MinValue)
                {
                    ocmdPCS.Parameters[PRO_WCCapacityTable.MACHINENO_FLD].Value = objObject.MachineNo;
                }
                else
                {
                    ocmdPCS.Parameters[PRO_WCCapacityTable.MACHINENO_FLD].Value = DBNull.Value;
                }

                ocmdPCS.Parameters.Add(new OleDbParameter(PRO_WCCapacityTable.BEGINDATE_FLD, OleDbType.Date));
                ocmdPCS.Parameters[PRO_WCCapacityTable.BEGINDATE_FLD].Value = objObject.BeginDate;

                ocmdPCS.Parameters.Add(new OleDbParameter(PRO_WCCapacityTable.ENDDATE_FLD, OleDbType.Date));
                ocmdPCS.Parameters[PRO_WCCapacityTable.ENDDATE_FLD].Value = objObject.EndDate;

                ocmdPCS.Parameters.Add(new OleDbParameter(PRO_WCCapacityTable.FACTOR_FLD, OleDbType.Decimal));
                ocmdPCS.Parameters[PRO_WCCapacityTable.FACTOR_FLD].Value = objObject.Factor;

                ocmdPCS.Parameters.Add(new OleDbParameter(PRO_WCCapacityTable.CAPACITY_FLD, OleDbType.Decimal));
                ocmdPCS.Parameters[PRO_WCCapacityTable.CAPACITY_FLD].Value = objObject.Capacity;

                ocmdPCS.Parameters.Add(new OleDbParameter(PRO_WCCapacityTable.CREWSIZE_FLD, OleDbType.Decimal));
                if (objObject.CrewSize != Decimal.MinusOne)
                {
                    ocmdPCS.Parameters[PRO_WCCapacityTable.CREWSIZE_FLD].Value = objObject.CrewSize;
                }
                else
                {
                    ocmdPCS.Parameters[PRO_WCCapacityTable.CREWSIZE_FLD].Value = DBNull.Value;
                }

                ocmdPCS.Parameters.Add(new OleDbParameter(PRO_WCCapacityTable.CCNID_FLD, OleDbType.Integer));
                ocmdPCS.Parameters[PRO_WCCapacityTable.CCNID_FLD].Value = objObject.CCNID;

                ocmdPCS.Parameters.Add(new OleDbParameter(PRO_WCCapacityTable.WCTYPE_FLD, OleDbType.Integer));
                ocmdPCS.Parameters[PRO_WCCapacityTable.WCTYPE_FLD].Value = objObject.WCType;

                ocmdPCS.Parameters.Add(new OleDbParameter(PRO_WCCapacityTable.WORKCENTERID_FLD, OleDbType.Integer));
                ocmdPCS.Parameters[PRO_WCCapacityTable.WORKCENTERID_FLD].Value = objObject.WorkCenterID;

                ocmdPCS.Connection.Open();

                return(int.Parse(ocmdPCS.ExecuteScalar().ToString()));
            }
            catch (OleDbException ex)
            {
                if (ex.Errors[1].NativeError == ErrorCode.SQLDUPLICATE_KEYCODE)
                {
                    throw new PCSDBException(ErrorCode.DUPLICATE_KEY, METHOD_NAME, ex);
                }
                else
                {
                    throw new PCSDBException(ErrorCode.ERROR_DB, METHOD_NAME, ex);
                }
            }
            catch (InvalidOperationException ex)
            {
                throw new PCSDBException(ErrorCode.ERROR_DB, METHOD_NAME, ex);
            }
            catch (Exception ex)
            {
                throw new PCSDBException(ErrorCode.OTHER_ERROR, METHOD_NAME, ex);
            }
            finally
            {
                if (oconPCS != null)
                {
                    if (oconPCS.State != ConnectionState.Closed)
                    {
                        oconPCS.Close();
                    }
                }
            }
        }