private void buttonStart_Click(object sender, EventArgs e) { bool[] DOStatus; Adam_AIAlarmMode mode; if (m_bStart) // was started { panelAO.Enabled = false; panelAlarm.Enabled = false; m_bStart = false; timer1.Enabled = false; adamCom.CloseComPort(); buttonStart.Text = "Start"; } else { if (adamCom.OpenComPort()) { // set COM port state, 9600,N,8,1 adamCom.SetComPortState(Baudrate.Baud_9600, Databits.Eight, Parity.None, Stopbits.One); // set COM port timeout adamCom.SetComPortTimeout(500, 500, 0, 500, 0); m_iCount = 0; // reset the reading counter // get module config if (!adamCom.Configuration(m_iAddr).GetModuleConfig(out m_adamConfig)) { adamCom.CloseComPort(); MessageBox.Show("Failed to get module config!", "Error"); return; } // detect alarm if (adamCom.Alarm(m_iAddr).GetModeAlarmDO(2, out mode, out DOStatus)) { m_DOStatus[0] = DOStatus[0]; m_DOStatus[1] = DOStatus[1]; txtMode.Text = mode.ToString(); if (mode == Adam_AIAlarmMode.Disable) // alarm is disabled { buttonDO0.Enabled = true; buttonDO1.Enabled = true; } else { buttonDO0.Enabled = false; buttonDO1.Enabled = false; } } // panelAO.Enabled = true; panelAlarm.Enabled = true; timer1.Enabled = true; // enable timer buttonStart.Text = "Stop"; m_bStart = true; // starting flag } else { MessageBox.Show("Failed to open COM port!", "Error"); } } }
private void buttonStart_Click(object sender, EventArgs e) { if (m_bStart) // was started { panelLED.Enabled = false; panelCount.Enabled = false; m_bStart = false; timer1.Enabled = false; adamCom.CloseComPort(); buttonStart.Text = "Start"; } else { if (adamCom.OpenComPort()) { // set COM port state, 9600,N,8,1 adamCom.SetComPortState(Baudrate.Baud_9600, Databits.Eight, Parity.None, Stopbits.One); // set COM port timeout adamCom.SetComPortTimeout(500, 500, 0, 500, 0); m_iCount = 0; // reset the reading counter // get module config if (!adamCom.Configuration(m_iAddr).GetModuleConfig(out m_adamConfig)) { adamCom.CloseComPort(); MessageBox.Show("Failed to get module config!", "Error"); return; } // LED panel panelLED.Enabled = true; RefreshLEDSource(); // Counter panel if (m_adamConfig.TypeCode == (byte)Adam4080_CounterMode.Counter) { panelCount.Enabled = true; cbxChannel.SelectedIndex = 0; RefreshAlarmButton(); } else { panelCount.Enabled = false; } timer1.Enabled = true; // enable timer buttonStart.Text = "Stop"; m_bStart = true; // starting flag } else { MessageBox.Show("Failed to open COM port!", "Error"); } } }
public VoltageController(VM_MSConfig msConfig) { Config = msConfig; m_iCom = 3; // using COM4 m_iAddr = 1; // the slave address is 1 m_iCount = 0; // the counting start from 0 m_bStart = false; m_Adam4000Type = Adam4000Type.Adam4019P; // the sample is for ADAM-4019P m_iChTotal = AnalogInput.GetChannelTotal(m_Adam4000Type); m_byRange = new byte[m_iChTotal]; adamCom = new AdamCom(m_iCom); adamCom.Checksum = false; // disbale checksum Module = m_Adam4000Type.ToString(); if (adamCom.OpenComPort()) { // set COM port state, 9600,N,8,1 adamCom.SetComPortState(Baudrate.Baud_9600, Databits.Eight, Parity.None, Stopbits.One); // set COM port timeout adamCom.SetComPortTimeout(500, 500, 0, 500, 0); m_iCount = 0; // reset the reading counter // get module config if (!adamCom.Configuration(m_iAddr).GetModuleConfig(out m_adamConfig)) { adamCom.CloseComPort(); LogHelper.WriteErrorLog("Failed to get module config!"); return; } // RefreshChannelEnable(); RefreshChannelRange(); // m_bStart = true; // starting flag } else { LogHelper.WriteErrorLog("Failed to open COM port!"); } }
private void buttonStart_Click(object sender, EventArgs e) { if (m_bStart) // was started { tabControl1.Enabled = false; m_bStart = false; timer1.Enabled = false; adamCom.CloseComPort(); buttonStart.Text = "Start"; } else { if (adamCom.OpenComPort()) { // set COM port state, 9600,N,8,1 adamCom.SetComPortState(Baudrate.Baud_9600, Databits.Eight, Parity.None, Stopbits.One); // set COM port timeout adamCom.SetComPortTimeout(500, 500, 0, 500, 0); m_iCount = 0; // reset the reading counter // get module config if (!adamCom.Configuration(m_iAddr).GetModuleConfig(out m_adamConfig)) { adamCom.CloseComPort(); MessageBox.Show("Failed to get module config!", "Error"); return; } // RefreshChannelEnable(); // tabControl1.Enabled = true; timer1.Enabled = true; // enable timer buttonStart.Text = "Stop"; m_bStart = true; // starting flag } else { MessageBox.Show("Failed to open COM port!", "Error"); } } }
public void Open() { adamCom = new AdamCom(SerialPortNumber); adamCom.Checksum = Checksum; bool opened = false; try { if (!adamCom.IsOpen) { opened = adamCom.OpenComPort(); } if (!opened) { return; } // set COM port state, 9600,N,8,1 adamCom.SetComPortState(Baudrate.Baud_9600, Databits.Eight, Parity.None, Stopbits.One, FlowControl.None); // set COM port timeout adamCom.SetComPortTimeout(500, 1000, 0, 1000, 0); if (!adamCom.Configuration(address).GetModuleConfig(out config)) { opened = false; adamCom.CloseComPort(); return; } } finally { Opened = opened; } }