public async Task <DashboardInspectionDetailsViewModel> GetDashboardInspectionDetailsViewModel(int incidentId) { var incident = await GetIncidentById(incidentId); Inspection inspection = null; if (incident.sl_inspectionIDId == null) { return(null); } inspection = await GetInspectionById(incident.sl_inspectionIDId.Value); DashboardInspectionDetailsViewModel viewModel = new DashboardInspectionDetailsViewModel(); viewModel.incidentId = incidentId; viewModel.inspection = inspection; if (inspection.sl_propertyID != null) { if (inspection.sl_propertyID.Id > 0) { inspection.sl_propertyID.propertyImgUrl = await GetPropertyPhoto(inspection.sl_propertyID.Id); } } viewModel.incident = incident; if (incident.sl_repairScheduled == null) { viewModel.viewName = "schedule a repair"; viewModel.repairPeople = await GetRepairPeople(); viewModel.roomInspectionPhotos = await GetInspectionPhotos(inspection.Id); viewModel.inspectionComment = await GetInspectionComment(inspection.Id); } else if (incident.sl_repairCompleted == null) { viewModel.viewName = "repair in progress"; viewModel.roomInspectionPhotos = await GetInspectionPhotos(inspection.Id); viewModel.inspectionComment = await GetInspectionComment(inspection.Id); } else if (incident.sl_repairApproved == null) { viewModel.viewName = "repair complete"; viewModel.roomInspectionPhotos = await GetInspectionPhotos(inspection.Id); viewModel.inspectionComment = await GetInspectionComment(inspection.Id); viewModel.repairPhotos = await GetRepairPhotos(incidentId); } return(viewModel); }
public async Task<ActionResult> InspectionDetails(DashboardInspectionDetailsViewModel model) { var sharePointToken = await O365Util.GetAccessToken(ServiceResources.DemoSite); var service = new TasksService(sharePointToken); await service.CompleteRepairAssignmentTask(model.incidentId); var dashboardModel = new Dashboard(sharePointToken); var calendarEvent = await dashboardModel.ScheduleRepair(model); await O365CalendarController.Create(calendarEvent); return RedirectToAction("InspectionDetails", new { id = model.incidentId }); }
public async Task <Event> ScheduleRepair(DashboardInspectionDetailsViewModel model) { DateTime repairDate = DateTime.Parse(model.timeSlotsSelectedValue); ScheduleRepairUpdate updateJson = new ScheduleRepairUpdate(); updateJson.sl_dispatcherComments = model.dispatcherComments; updateJson.sl_repairScheduled = repairDate.ToUniversalTime(); updateJson.sl_repairPerson = model.repairPeopleSelectedValue; updateJson.__metadata = new metadata { type = "SP.Data.IncidentsListItem" }; await SuiteLevelWebApp.Utils.RestHelper.PostRestDataToDemoSite("/_api/lists/GetByTitle('Incidents')/Items(" + model.incidentId + ")", JsonConvert.SerializeObject(updateJson), _token); var incident = await GetIncidentById(model.incidentId); var repairPeople = await GetRepairPeopleByEmailAddress(model.repairPeopleSelectedValue); //create a new event Attendee attendee = new Attendee { EmailAddress = new EmailAddress { Address = repairPeople.sl_emailaddress, Name = repairPeople.Title }, Type = AttendeeType.Required }; Attendee[] attendees = new Attendee[1]; attendees[0] = attendee; Event newEvent = new Event { Subject = "Repair Event", Body = new ItemBody { Content = incident.sl_dispatcherComments, ContentType = BodyType.HTML }, ShowAs = FreeBusyStatus.Busy, Start = repairDate.ToUniversalTime(), End = (repairDate.AddHours(1)).ToUniversalTime(), Location = new Location { DisplayName = incident.sl_roomID.Title }, Attendees = attendees }; return(newEvent); }
public async Task<DashboardInspectionDetailsViewModel> GetDashboardInspectionDetailsViewModel(int incidentId) { var incident = await GetIncidentById(incidentId); Inspection inspection = null; if (incident.sl_inspectionIDId == null) { return null; } inspection = await GetInspectionById(incident.sl_inspectionIDId.Value); DashboardInspectionDetailsViewModel viewModel = new DashboardInspectionDetailsViewModel(); viewModel.incidentId = incidentId; viewModel.inspection = inspection; if (inspection.sl_propertyID != null) { if (inspection.sl_propertyID.Id > 0) { inspection.sl_propertyID.propertyImgUrl = await GetPropertyPhoto(inspection.sl_propertyID.Id); } } viewModel.incident = incident; if (incident.sl_repairScheduled == null) { viewModel.viewName = "schedule a repair"; viewModel.repairPeople = await GetRepairPeople(); viewModel.roomInspectionPhotos = await GetInspectionPhotos(inspection.Id); viewModel.inspectionComment = await GetInspectionComment(inspection.Id); } else if (incident.sl_repairCompleted == null) { viewModel.viewName = "repair in progress"; viewModel.roomInspectionPhotos = await GetInspectionPhotos(inspection.Id); viewModel.inspectionComment = await GetInspectionComment(inspection.Id); } else if (incident.sl_repairApproved == null) { viewModel.viewName = "repair complete"; viewModel.roomInspectionPhotos = await GetInspectionPhotos(inspection.Id); viewModel.inspectionComment = await GetInspectionComment(inspection.Id); viewModel.repairPhotos = await GetRepairPhotos(incidentId); } return viewModel; }
public async Task<ActionResult> AuditRepair(string button, DashboardInspectionDetailsViewModel model) { var outlookToken = await O365Util.GetAccessToken(Capabilities.Mail); var sharePointToken = await O365Util.GetAccessToken(ServiceResources.DemoSite); var outlookClient = await O365Util.GetOutlookClient(Capabilities.Mail); Dashboard dashboardModel = new Dashboard(sharePointToken); var result = button == "Approve" ? ApprovalResult.Approved : ApprovalResult.Rejected; var tasksService = new TasksService(sharePointToken); await tasksService.CompleteRepairApprovalTask(model.incidentId, result); if (result == ApprovalResult.Approved) { await dashboardModel.ApproveRepair(model.incidentId); //This is the pattern you would use to send email from O365 APIs. These emails are sent via the mobile apps. //var emailService = new EmailService(sharePointToken, Server.MapPath("/")); //var emailMessage = await emailService.ComposeRepairCompletedEmailMessage(model.incidentId); //await outlookClient.Me.SendMailAsync(emailMessage, true); } return new RedirectResult("/Dashboard/Index"); }
public async Task <DashboardInspectionDetailsViewModel> GetDashboardInspectionDetailsViewModelAsync(Graph.GraphService graphService, OneNoteServiceFactory oneNoteServiceFactory, int incidentId, string CurrentUser) { Task <Graph.IUser[]> getRepairPeople = null; Task <RepairPhoto[]> getRepairPhotos = null; var videos = GetVideosAsync(AppSettings.VideoPortalIncidentsChannelName, incidentId); var incident = await GetIncidentByIdAsync(incidentId); if (incident.sl_inspectionIDId == null) { return(null); } var property = incident.sl_propertyID; var propertyImgUrl = GetPropertyPhotoAsync(property.Id); var inspectionID = incident.sl_inspectionIDId.Value; var inspection = GetInspectionByIdAsync(inspectionID); var getInspectionPhotos = GetInspectionPhotosAsync(inspectionID); var incidentStatus = incident.sl_status; if (incidentStatus == "Pending Assignment") { getRepairPeople = graphService.GetGroupMembersAsync("Repair People"); } if (incidentStatus == "Repair Pending Approval" || incidentStatus == "Repair Approved") { getRepairPhotos = GetRepairPhotosAsync(incidentId); } var unifiedGroupFetcher = graphService.groups.GetById(property.sl_group); var unifiedGroup = unifiedGroupFetcher.ExecuteAsync(); var groupFiles = GetGroupFilesAsync(unifiedGroupFetcher, (await unifiedGroup).mailNickname); var groupConversations = GetConversationsAsync(unifiedGroupFetcher, (await unifiedGroup).mail); var notebookName = (await unifiedGroup).displayName + " Notebook";; var oneNoteService = oneNoteServiceFactory.CreateOneNoteServiceForUnifiedGroup(await unifiedGroup); var notebook = GetOrCreateNoteBook(await oneNoteService, notebookName); var pages = (await notebook) != null ? GetOneNotePagesAsync(await oneNoteService, (await notebook).Id, property.Title, incidentId) : Task.FromResult(new HyperLink[0]); // Repair people are included in property group. // Before we get members of a group, we must make sure that repair people have been retrieved. // Otherwise, we'll get an error: // The context is already tracking a different entity with the same resource Uri. if (getRepairPeople != null) { await getRepairPeople; } var groupMembers = graphService.GetGroupMembersAsync(unifiedGroupFetcher); var recentEarliestDateTime = new DateTimeOffset(DateTime.UtcNow).AddDays(-7); var recentDocuments = (await groupFiles) .Where(i => i.dateTimeLastModified > recentEarliestDateTime) .ToList(); property.propertyImgUrl = await propertyImgUrl; var isCurrentUserDispatcher = CurrentUser == AppSettings.DispatcherEmail; var viewModel = new DashboardInspectionDetailsViewModel { viewName = IncidentStatusViewMappings[incidentStatus], PropertyDetail = property, incidentId = incidentId, incident = incident, UnifiedGroupNickName = (await unifiedGroup).mailNickname, UnifiedGroupId = (await unifiedGroup).objectId, UnifiedGroupEmail = (await unifiedGroup).mail, inspection = await inspection, videos = await videos, files = (await groupFiles) .Select(i => HyperLink.Create(i.name, i.webUrl)) .ToArray(), recentDocuments = recentDocuments .Select(i => HyperLink.Create(i.name, i.webUrl)) .ToArray(), members = await groupMembers, roomInspectionPhotos = await getInspectionPhotos, inspectionComment = await GetInspectionCommentAsync(inspectionID, incident.sl_roomID.Id), //tasks = await GetTaskHyperLinksAsync(unifiedGroup) repairPeople = getRepairPeople != null ? await getRepairPeople : new Graph.IUser[0], repairPhotos = getRepairPhotos != null ? await getRepairPhotos : new RepairPhoto[0], DispatcherMails = isCurrentUserDispatcher ? await GetMailsForDispatcherAsync(graphService, CurrentUser) : new HyperLink[0], oneNoteUrl = (await notebook) != null ? (await notebook).Url : "", oneNotePages = await pages, conversations = await groupConversations }; return(viewModel); }
public async Task <DashboardInspectionDetailsViewModel> GetDashboardInspectionDetailsViewModelAsync(GraphServiceClient graphService, int incidentId, string CurrentUser) { Graph.User[] getRepairPeople = null; Task <RepairPhoto[]> getRepairPhotos = null; var videos = await GetVideosAsync(AppSettings.VideoPortalIncidentsChannelName, incidentId); var incident = await GetIncidentByIdAsync(incidentId); if (incident.sl_inspectionIDId == null) { return(null); } var property = incident.sl_propertyID; var propertyImgUrl = GetPropertyPhotoAsync(property.Id); var inspectionID = incident.sl_inspectionIDId.Value; var inspection = await GetInspectionByIdAsync(inspectionID); var getInspectionPhotos = await GetInspectionPhotosAsync(inspectionID); var incidentStatus = incident.sl_status; if (incidentStatus == "Pending Assignment") { getRepairPeople = await graphService.GetGroupMembersAsync("Repair People"); } if (incidentStatus == "Repair Pending Approval" || incidentStatus == "Repair Approved") { getRepairPhotos = GetRepairPhotosAsync(incidentId); } var unifiedGroupFetcher = graphService.Groups[property.sl_group]; var unifiedGroup = await unifiedGroupFetcher.Request().GetAsync(); var groupFiles = await GetGroupFilesAsync(unifiedGroupFetcher); var groupConversations = await GetConversationsAsync(unifiedGroupFetcher, unifiedGroup.Mail); var propertyExcelWorkbook = await ExcelService.GetPropertyExcelWorkbooksAsync(property.sl_group); var notebook = await OneNoteService.GetNoteBookByNameAsync(unifiedGroup, unifiedGroup.DisplayName + " Notebook"); var oneNotePages = (notebook != null) ? await Services.OneNoteService.GetOneNotePagesAsync(graphService, unifiedGroup) : await Task.FromResult(new HyperLink[0]); var groupMembers = await graphService.GetGroupMembersAsync(unifiedGroupFetcher); var plan = await PlanService.GetPlanAsync(unifiedGroup); List <O365Task> tasks = new List <O365Task>(); if (plan != null) { tasks = await GetO365TasksAsync(graphService, plan); } var recentEarliestDateTime = new DateTimeOffset(DateTime.UtcNow).AddDays(-7); var recentDocuments = groupFiles .Where(i => i.dateTimeLastModified > recentEarliestDateTime) .ToList(); property.propertyImgUrl = await propertyImgUrl; var isCurrentUserDispatcher = CurrentUser == AppSettings.DispatcherEmail; var bannotateImage = true; if (notebook == null || string.IsNullOrEmpty(notebook.oneNoteWebUrl) || oneNotePages.Where(x => x.Title.ToString().Equals(string.Format("Incident[{0}]", incidentId))).Count() > 0) { bannotateImage = false; } var viewModel = new DashboardInspectionDetailsViewModel { viewName = IncidentStatusViewMappings[incidentStatus], PropertyDetail = property, incidentId = incidentId, incident = incident, UnifiedGroupNickName = unifiedGroup.MailNickname, UnifiedGroupId = unifiedGroup.Id, UnifiedGroupEmail = unifiedGroup.Mail, inspection = inspection, videos = videos, files = groupFiles .Select(i => HyperLink.Create(i.name, i.webUrl, i.id)) .ToArray(), recentDocuments = recentDocuments .Select(i => HyperLink.Create(i.name, i.webUrl, i.id)) .ToArray(), members = groupMembers, roomInspectionPhotos = getInspectionPhotos, inspectionComment = await GetInspectionCommentAsync(inspectionID, incident.sl_roomID.Id), tasks = tasks.ToArray(), repairPeople = getRepairPeople != null ? getRepairPeople : new Graph.User[0], repairPhotos = getRepairPhotos != null ? await getRepairPhotos : new RepairPhoto[0], DispatcherMails = isCurrentUserDispatcher ? await GetMailsForDispatcherAsync(graphService, CurrentUser) : new HyperLink[0], oneNotePages = oneNotePages, oneNoteUrl = notebook != null ? notebook.oneNoteWebUrl: "", conversations = groupConversations, PlanId = plan != null ? plan.id : string.Empty, PropertyExcelWorkbook = propertyExcelWorkbook, bAnnotateImage = bannotateImage }; return(viewModel); }
public async Task<Event> ScheduleRepair(DashboardInspectionDetailsViewModel model) { DateTime repairDate = DateTime.Parse(model.timeSlotsSelectedValue); ScheduleRepairUpdate updateJson = new ScheduleRepairUpdate(); updateJson.sl_dispatcherComments = model.dispatcherComments; updateJson.sl_repairScheduled = repairDate.ToUniversalTime(); updateJson.sl_repairPerson = model.repairPeopleSelectedValue; updateJson.__metadata = new metadata { type = "SP.Data.IncidentsListItem" }; await SuiteLevelWebApp.Utils.RestHelper.PostRestDataToDemoSite("/_api/lists/GetByTitle('Incidents')/Items(" + model.incidentId + ")", JsonConvert.SerializeObject(updateJson), _token); var incident = await GetIncidentById(model.incidentId); var repairPeople = await GetRepairPeopleByEmailAddress(model.repairPeopleSelectedValue); //create a new event Attendee attendee = new Attendee { EmailAddress = new EmailAddress { Address = repairPeople.sl_emailaddress, Name = repairPeople.Title }, Type = AttendeeType.Required }; Attendee[] attendees = new Attendee[1]; attendees[0] = attendee; Event newEvent = new Event { Subject = "Repair Event", Body = new ItemBody { Content = incident.sl_dispatcherComments, ContentType = BodyType.HTML }, ShowAs = FreeBusyStatus.Busy, Start = repairDate.ToUniversalTime(), End = (repairDate.AddHours(1)).ToUniversalTime(), Location = new Location { DisplayName = incident.sl_roomID.Title }, Attendees = attendees }; return newEvent; }
public async Task<DashboardInspectionDetailsViewModel> GetDashboardInspectionDetailsViewModelAsync(Graph.GraphService graphService, OneNoteServiceFactory oneNoteServiceFactory, int incidentId, string CurrentUser) { Task<Graph.IUser[]> getRepairPeople = null; Task<RepairPhoto[]> getRepairPhotos = null; var videos = GetVideosAsync(AppSettings.VideoPortalIncidentsChannelName, incidentId); var incident = await GetIncidentByIdAsync(incidentId); if (incident.sl_inspectionIDId == null) return null; var property = incident.sl_propertyID; var propertyImgUrl = GetPropertyPhotoAsync(property.Id); var inspectionID = incident.sl_inspectionIDId.Value; var inspection = GetInspectionByIdAsync(inspectionID); var getInspectionPhotos = GetInspectionPhotosAsync(inspectionID); var incidentStatus = incident.sl_status; if (incidentStatus == "Pending Assignment") getRepairPeople = graphService.GetGroupMembersAsync("Repair People"); if (incidentStatus == "Repair Pending Approval" || incidentStatus == "Repair Approved") getRepairPhotos = GetRepairPhotosAsync(incidentId); var unifiedGroupFetcher = graphService.groups.GetById(property.sl_group); var unifiedGroup = unifiedGroupFetcher.ExecuteAsync(); var groupFiles = GetGroupFilesAsync(unifiedGroupFetcher, (await unifiedGroup).mailNickname); var groupConversations = GetConversationsAsync(unifiedGroupFetcher, (await unifiedGroup).mail); var notebookName = (await unifiedGroup).displayName + " Notebook"; ; var oneNoteService = oneNoteServiceFactory.CreateOneNoteServiceForUnifiedGroup(await unifiedGroup); var notebook = GetOrCreateNoteBook(await oneNoteService, notebookName); var pages = (await notebook) != null ? GetOneNotePagesAsync(await oneNoteService, (await notebook).Id, property.Title, incidentId) : Task.FromResult(new HyperLink[0]); // Repair people are included in property group. // Before we get members of a group, we must make sure that repair people have been retrieved. // Otherwise, we'll get an error: // The context is already tracking a different entity with the same resource Uri. if (getRepairPeople != null) await getRepairPeople; var groupMembers = graphService.GetGroupMembersAsync(unifiedGroupFetcher); var recentEarliestDateTime = new DateTimeOffset(DateTime.UtcNow).AddDays(-7); var recentDocuments = (await groupFiles) .Where(i => i.dateTimeLastModified > recentEarliestDateTime) .ToList(); property.propertyImgUrl = await propertyImgUrl; var isCurrentUserDispatcher = CurrentUser == AppSettings.DispatcherEmail; var viewModel = new DashboardInspectionDetailsViewModel { viewName = IncidentStatusViewMappings[incidentStatus], PropertyDetail = property, incidentId = incidentId, incident = incident, UnifiedGroupNickName = (await unifiedGroup).mailNickname, UnifiedGroupId = (await unifiedGroup).objectId, UnifiedGroupEmail = (await unifiedGroup).mail, inspection = await inspection, videos = await videos, files = (await groupFiles) .Select(i => HyperLink.Create(i.name, i.webUrl)) .ToArray(), recentDocuments = recentDocuments .Select(i => HyperLink.Create(i.name, i.webUrl)) .ToArray(), members = await groupMembers, roomInspectionPhotos = await getInspectionPhotos, inspectionComment = await GetInspectionCommentAsync(inspectionID, incident.sl_roomID.Id), //tasks = await GetTaskHyperLinksAsync(unifiedGroup) repairPeople = getRepairPeople != null ? await getRepairPeople : new Graph.IUser[0], repairPhotos = getRepairPhotos != null ? await getRepairPhotos : new RepairPhoto[0], DispatcherMails = isCurrentUserDispatcher ? await GetMailsForDispatcherAsync(graphService, CurrentUser) : new HyperLink[0], oneNoteUrl = (await notebook) != null ? (await notebook).Url : "", oneNotePages = await pages, conversations = await groupConversations }; return viewModel; }
public async Task<DashboardInspectionDetailsViewModel> GetDashboardInspectionDetailsViewModelAsync(GraphServiceClient graphService, int incidentId, string CurrentUser) { Graph.User[] getRepairPeople = null; Task<RepairPhoto[]> getRepairPhotos = null; var videos = await GetVideosAsync(AppSettings.VideoPortalIncidentsChannelName, incidentId); var incident = await GetIncidentByIdAsync(incidentId); if (incident.sl_inspectionIDId == null) return null; var property = incident.sl_propertyID; var propertyImgUrl = GetPropertyPhotoAsync(property.Id); var inspectionID = incident.sl_inspectionIDId.Value; var inspection = await GetInspectionByIdAsync(inspectionID); var getInspectionPhotos = await GetInspectionPhotosAsync(inspectionID); var incidentStatus = incident.sl_status; if (incidentStatus == "Pending Assignment") { getRepairPeople = await graphService.GetGroupMembersAsync("Repair People"); } if (incidentStatus == "Repair Pending Approval" || incidentStatus == "Repair Approved") getRepairPhotos = GetRepairPhotosAsync(incidentId); var unifiedGroupFetcher = graphService.Groups[property.sl_group]; var unifiedGroup = await unifiedGroupFetcher.Request().GetAsync(); var groupFiles = await GetGroupFilesAsync(unifiedGroupFetcher); var groupConversations = await GetConversationsAsync(unifiedGroupFetcher, unifiedGroup.Mail); var propertyExcelWorkbook = await ExcelService.GetPropertyExcelWorkbooksAsync(property.sl_group); var notebook = await OneNoteService.GetNoteBookByNameAsync(unifiedGroup, unifiedGroup.DisplayName + " Notebook"); var oneNotePages = (notebook != null) ? await Services.OneNoteService.GetOneNotePagesAsync(graphService, unifiedGroup) : await Task.FromResult(new HyperLink[0]); var groupMembers = await graphService.GetGroupMembersAsync(unifiedGroupFetcher); var plan = await PlanService.GetPlanAsync(unifiedGroup); List<O365Task> tasks = new List<O365Task>(); if (plan != null) { tasks = await GetO365TasksAsync(graphService, plan); } var recentEarliestDateTime = new DateTimeOffset(DateTime.UtcNow).AddDays(-7); var recentDocuments = groupFiles .Where(i => i.dateTimeLastModified > recentEarliestDateTime) .ToList(); property.propertyImgUrl = await propertyImgUrl; var isCurrentUserDispatcher = CurrentUser == AppSettings.DispatcherEmail; var bannotateImage = true; if (notebook == null || string.IsNullOrEmpty(notebook.oneNoteWebUrl)|| oneNotePages.Where(x => x.Title.ToString().Equals(string.Format("Incident[{0}]", incidentId))).Count() > 0) { bannotateImage = false; } var viewModel = new DashboardInspectionDetailsViewModel { viewName = IncidentStatusViewMappings[incidentStatus], PropertyDetail = property, incidentId = incidentId, incident = incident, UnifiedGroupNickName = unifiedGroup.MailNickname, UnifiedGroupId = unifiedGroup.Id, UnifiedGroupEmail = unifiedGroup.Mail, inspection = inspection, videos = videos, files = groupFiles .Select(i => HyperLink.Create(i.name, i.webUrl, i.id)) .ToArray(), recentDocuments = recentDocuments .Select(i => HyperLink.Create(i.name, i.webUrl, i.id)) .ToArray(), members = groupMembers, roomInspectionPhotos = getInspectionPhotos, inspectionComment = await GetInspectionCommentAsync(inspectionID, incident.sl_roomID.Id), tasks = tasks.ToArray(), repairPeople = getRepairPeople != null ? getRepairPeople : new Graph.User[0], repairPhotos = getRepairPhotos != null ? await getRepairPhotos : new RepairPhoto[0], DispatcherMails = isCurrentUserDispatcher ? await GetMailsForDispatcherAsync(graphService, CurrentUser) : new HyperLink[0], oneNotePages = oneNotePages, oneNoteUrl = notebook != null ? notebook.oneNoteWebUrl: "", conversations = groupConversations, PlanId = plan != null ? plan.id : string.Empty, PropertyExcelWorkbook = propertyExcelWorkbook, bAnnotateImage = bannotateImage }; return viewModel; }