/// <summary> /// Add new object and return id /// 12/Oct/2005 Thachnn: fix bug injection /// </summary> /// <param name="pobjFieldGroup">Object to add</param> /// <returns>New ID</returns> public int AddAndReturnID(object pobjFieldGroup) { const string METHOD_NAME = THIS + ".AddAndReturnID()"; OleDbConnection oconPCS = null; OleDbCommand ocmdPCS = null; try { Sys_FieldGroupVO objObject = (Sys_FieldGroupVO)pobjFieldGroup; string strSql = String.Empty; Utils utils = new Utils(); oconPCS = new OleDbConnection(Utils.Instance.OleDbConnectionString); ocmdPCS = new OleDbCommand("", oconPCS); strSql = "INSERT INTO Sys_FieldGroup(" + Sys_FieldGroupTable.GROUPCODE_FLD + "," + Sys_FieldGroupTable.GROUPORDER_FLD + "," + Sys_FieldGroupTable.GROUPLEVEL_FLD + "," + Sys_FieldGroupTable.GROUPNAMEVN_FLD + "," + Sys_FieldGroupTable.GROUPNAMEEN_FLD + "," + Sys_FieldGroupTable.GROUPNAMEJP_FLD + "," + Sys_FieldGroupTable.REPORTID_FLD + "," + Sys_FieldGroupTable.PARENTFIELDGROUPID_FLD + ")" + "VALUES(?,?,?,?,?,?,?,?)"; strSql += " ; SELECT @@IDENTITY AS NEWID"; ocmdPCS.Parameters.Add(new OleDbParameter(Sys_FieldGroupTable.GROUPCODE_FLD, OleDbType.VarWChar)); ocmdPCS.Parameters[Sys_FieldGroupTable.GROUPCODE_FLD].Value = objObject.GroupCode; ocmdPCS.Parameters.Add(new OleDbParameter(Sys_FieldGroupTable.GROUPORDER_FLD, OleDbType.Integer)); ocmdPCS.Parameters[Sys_FieldGroupTable.GROUPORDER_FLD].Value = objObject.GroupOrder; ocmdPCS.Parameters.Add(new OleDbParameter(Sys_FieldGroupTable.GROUPLEVEL_FLD, OleDbType.Integer)); ocmdPCS.Parameters[Sys_FieldGroupTable.GROUPLEVEL_FLD].Value = objObject.GroupLevel; ocmdPCS.Parameters.Add(new OleDbParameter(Sys_FieldGroupTable.GROUPNAMEVN_FLD, OleDbType.VarWChar)); ocmdPCS.Parameters[Sys_FieldGroupTable.GROUPNAMEVN_FLD].Value = objObject.GroupNameVN; ocmdPCS.Parameters.Add(new OleDbParameter(Sys_FieldGroupTable.GROUPNAMEEN_FLD, OleDbType.VarWChar)); ocmdPCS.Parameters[Sys_FieldGroupTable.GROUPNAMEEN_FLD].Value = objObject.GroupNameEN; ocmdPCS.Parameters.Add(new OleDbParameter(Sys_FieldGroupTable.GROUPNAMEJP_FLD, OleDbType.VarWChar)); ocmdPCS.Parameters[Sys_FieldGroupTable.GROUPNAMEJP_FLD].Value = objObject.GroupNameJP; ocmdPCS.Parameters.Add(new OleDbParameter(Sys_FieldGroupTable.REPORTID_FLD, OleDbType.VarWChar)); ocmdPCS.Parameters[Sys_FieldGroupTable.REPORTID_FLD].Value = objObject.ReportID; ocmdPCS.Parameters.Add(new OleDbParameter(Sys_FieldGroupTable.PARENTFIELDGROUPID_FLD, OleDbType.Integer)); if (objObject.ParentFieldGroupID > 0) { ocmdPCS.Parameters[Sys_FieldGroupTable.PARENTFIELDGROUPID_FLD].Value = objObject.ParentFieldGroupID; } else { ocmdPCS.Parameters[Sys_FieldGroupTable.PARENTFIELDGROUPID_FLD].Value = DBNull.Value; } ocmdPCS.CommandText = strSql; ocmdPCS.Connection.Open(); object objResult = ocmdPCS.ExecuteScalar(); if (objResult != null && objResult != DBNull.Value) { return(int.Parse(objResult.ToString())); } else { return(0); } } catch (OleDbException ex) { if (ex.Errors[1].NativeError == ErrorCode.SQLDUPLICATE_KEYCODE) { throw new PCSDBException(ErrorCode.DUPLICATE_KEY, METHOD_NAME, ex); } else { throw new PCSDBException(ErrorCode.ERROR_DB, METHOD_NAME, ex); } } catch (InvalidOperationException ex) { throw new PCSDBException(ErrorCode.ERROR_DB, METHOD_NAME, ex); } catch (Exception ex) { throw new PCSDBException(ErrorCode.OTHER_ERROR, METHOD_NAME, ex); } finally { if (oconPCS != null) { if (oconPCS.State != ConnectionState.Closed) { oconPCS.Close(); } } } }
//************************************************************************** /// <Description> /// This method uses to get data from Sys_FieldGroup /// </Description> /// <Inputs> /// ID /// </Inputs> /// <Outputs> /// Sys_FieldGroupVO /// </Outputs> /// <Returns> /// Sys_FieldGroupVO /// </Returns> /// <Authors> /// HungLa /// </Authors> /// <History> /// Saturday, September 17, 2005 /// </History> /// <Notes> /// </Notes> //************************************************************************** public object GetObjectVO(int pintID) { const string METHOD_NAME = THIS + ".GetObjectVO()"; OleDbDataReader odrPCS = null; OleDbConnection oconPCS = null; OleDbCommand ocmdPCS = null; try { string strSql = String.Empty; strSql = "SELECT " + Sys_FieldGroupTable.FIELDGROUPID_FLD + "," + Sys_FieldGroupTable.GROUPCODE_FLD + "," + Sys_FieldGroupTable.GROUPORDER_FLD + "," + Sys_FieldGroupTable.GROUPLEVEL_FLD + "," + Sys_FieldGroupTable.GROUPNAMEVN_FLD + "," + Sys_FieldGroupTable.GROUPNAMEEN_FLD + "," + Sys_FieldGroupTable.GROUPNAMEJP_FLD + "," + Sys_FieldGroupTable.REPORTID_FLD + "," + Sys_FieldGroupTable.PARENTFIELDGROUPID_FLD + " FROM " + Sys_FieldGroupTable.TABLE_NAME + " WHERE " + Sys_FieldGroupTable.FIELDGROUPID_FLD + "=" + pintID; Utils utils = new Utils(); oconPCS = new OleDbConnection(Utils.Instance.OleDbConnectionString); ocmdPCS = new OleDbCommand(strSql, oconPCS); ocmdPCS.Connection.Open(); odrPCS = ocmdPCS.ExecuteReader(); Sys_FieldGroupVO objObject = new Sys_FieldGroupVO(); while (odrPCS.Read()) { objObject.FieldGroupID = int.Parse(odrPCS[Sys_FieldGroupTable.FIELDGROUPID_FLD].ToString().Trim()); objObject.GroupCode = odrPCS[Sys_FieldGroupTable.GROUPCODE_FLD].ToString().Trim(); objObject.GroupOrder = int.Parse(odrPCS[Sys_FieldGroupTable.GROUPORDER_FLD].ToString().Trim()); objObject.GroupLevel = int.Parse(odrPCS[Sys_FieldGroupTable.GROUPLEVEL_FLD].ToString().Trim()); objObject.GroupNameVN = odrPCS[Sys_FieldGroupTable.GROUPNAMEVN_FLD].ToString().Trim(); objObject.GroupNameEN = odrPCS[Sys_FieldGroupTable.GROUPNAMEEN_FLD].ToString().Trim(); objObject.GroupNameJP = odrPCS[Sys_FieldGroupTable.GROUPNAMEJP_FLD].ToString().Trim(); objObject.ReportID = odrPCS[Sys_FieldGroupTable.REPORTID_FLD].ToString().Trim(); objObject.ParentFieldGroupID = int.Parse(odrPCS[Sys_FieldGroupTable.PARENTFIELDGROUPID_FLD].ToString().Trim()); } return(objObject); } catch (OleDbException ex) { throw new PCSDBException(ErrorCode.ERROR_DB, METHOD_NAME, ex); } catch (Exception ex) { throw new PCSDBException(ErrorCode.OTHER_ERROR, METHOD_NAME, ex); } finally { if (oconPCS != null) { if (oconPCS.State != ConnectionState.Closed) { oconPCS.Close(); } } } }
//************************************************************************** /// <Description> /// This method uses to update data to Sys_FieldGroup /// </Description> /// <Inputs> /// Sys_FieldGroupVO /// </Inputs> /// <Outputs> /// /// </Outputs> /// <Returns> /// /// </Returns> /// <Authors> /// HungLa /// </Authors> /// <History> /// 09-Dec-2004 /// </History> /// <Notes> /// </Notes> //************************************************************************** public void Update(object pobjObjecVO) { const string METHOD_NAME = THIS + ".Update()"; Sys_FieldGroupVO objObject = (Sys_FieldGroupVO)pobjObjecVO; //prepare value for parameters OleDbConnection oconPCS = null; OleDbCommand ocmdPCS = null; try { string strSql = String.Empty; Utils utils = new Utils(); oconPCS = new OleDbConnection(Utils.Instance.OleDbConnectionString); ocmdPCS = new OleDbCommand(strSql, oconPCS); strSql = "UPDATE Sys_FieldGroup SET " + Sys_FieldGroupTable.GROUPCODE_FLD + "= ?" + "," + Sys_FieldGroupTable.GROUPORDER_FLD + "= ?" + "," + Sys_FieldGroupTable.GROUPLEVEL_FLD + "= ?" + "," + Sys_FieldGroupTable.GROUPNAMEVN_FLD + "= ?" + "," + Sys_FieldGroupTable.GROUPNAMEEN_FLD + "= ?" + "," + Sys_FieldGroupTable.GROUPNAMEJP_FLD + "= ?" + "," + Sys_FieldGroupTable.REPORTID_FLD + "= ?" + "," + Sys_FieldGroupTable.PARENTFIELDGROUPID_FLD + "= ?" + " WHERE " + Sys_FieldGroupTable.FIELDGROUPID_FLD + "= ?"; ocmdPCS.Parameters.Add(new OleDbParameter(Sys_FieldGroupTable.GROUPCODE_FLD, OleDbType.VarWChar)); ocmdPCS.Parameters[Sys_FieldGroupTable.GROUPCODE_FLD].Value = objObject.GroupCode; ocmdPCS.Parameters.Add(new OleDbParameter(Sys_FieldGroupTable.GROUPORDER_FLD, OleDbType.Integer)); ocmdPCS.Parameters[Sys_FieldGroupTable.GROUPORDER_FLD].Value = objObject.GroupOrder; ocmdPCS.Parameters.Add(new OleDbParameter(Sys_FieldGroupTable.GROUPLEVEL_FLD, OleDbType.Integer)); ocmdPCS.Parameters[Sys_FieldGroupTable.GROUPLEVEL_FLD].Value = objObject.GroupLevel; ocmdPCS.Parameters.Add(new OleDbParameter(Sys_FieldGroupTable.GROUPNAMEVN_FLD, OleDbType.VarWChar)); ocmdPCS.Parameters[Sys_FieldGroupTable.GROUPNAMEVN_FLD].Value = objObject.GroupNameVN; ocmdPCS.Parameters.Add(new OleDbParameter(Sys_FieldGroupTable.GROUPNAMEEN_FLD, OleDbType.VarWChar)); ocmdPCS.Parameters[Sys_FieldGroupTable.GROUPNAMEEN_FLD].Value = objObject.GroupNameEN; ocmdPCS.Parameters.Add(new OleDbParameter(Sys_FieldGroupTable.GROUPNAMEJP_FLD, OleDbType.VarWChar)); ocmdPCS.Parameters[Sys_FieldGroupTable.GROUPNAMEJP_FLD].Value = objObject.GroupNameJP; ocmdPCS.Parameters.Add(new OleDbParameter(Sys_FieldGroupTable.REPORTID_FLD, OleDbType.VarWChar)); ocmdPCS.Parameters[Sys_FieldGroupTable.REPORTID_FLD].Value = objObject.ReportID; ocmdPCS.Parameters.Add(new OleDbParameter(Sys_FieldGroupTable.PARENTFIELDGROUPID_FLD, OleDbType.Integer)); ocmdPCS.Parameters[Sys_FieldGroupTable.PARENTFIELDGROUPID_FLD].Value = objObject.ParentFieldGroupID; ocmdPCS.Parameters.Add(new OleDbParameter(Sys_FieldGroupTable.FIELDGROUPID_FLD, OleDbType.Integer)); ocmdPCS.Parameters[Sys_FieldGroupTable.FIELDGROUPID_FLD].Value = objObject.FieldGroupID; ocmdPCS.CommandText = strSql; ocmdPCS.Connection.Open(); ocmdPCS.ExecuteNonQuery(); } catch (OleDbException ex) { if (ex.Errors[1].NativeError == ErrorCode.SQLDUPLICATE_KEYCODE) { throw new PCSDBException(ErrorCode.DUPLICATE_KEY, METHOD_NAME, ex); } else { throw new PCSDBException(ErrorCode.ERROR_DB, METHOD_NAME, ex); } } catch (InvalidOperationException ex) { throw new PCSDBException(ErrorCode.ERROR_DB, METHOD_NAME, ex); } catch (Exception ex) { throw new PCSDBException(ErrorCode.OTHER_ERROR, METHOD_NAME, ex); } finally { if (oconPCS != null) { if (oconPCS.State != ConnectionState.Closed) { oconPCS.Close(); } } } }
/// <summary> /// Get all field group of a report /// </summary> /// <param name="pstrReportID">Report ID</param> /// <returns>List of field group</returns> public ArrayList GetAllGroups(string pstrReportID) { const string METHOD_NAME = THIS + ".GetAllGroups()"; OleDbDataReader odrPCS = null; OleDbConnection oconPCS = null; OleDbCommand ocmdPCS = null; try { string strSql = String.Empty; strSql = "SELECT " + Sys_FieldGroupTable.FIELDGROUPID_FLD + "," + Sys_FieldGroupTable.GROUPCODE_FLD + "," + Sys_FieldGroupTable.GROUPORDER_FLD + "," + Sys_FieldGroupTable.GROUPLEVEL_FLD + "," + Sys_FieldGroupTable.GROUPNAMEVN_FLD + "," + Sys_FieldGroupTable.GROUPNAMEEN_FLD + "," + Sys_FieldGroupTable.GROUPNAMEJP_FLD + "," + Sys_FieldGroupTable.REPORTID_FLD + "," + Sys_FieldGroupTable.PARENTFIELDGROUPID_FLD + " FROM " + Sys_FieldGroupTable.TABLE_NAME + " WHERE " + Sys_FieldGroupTable.REPORTID_FLD + "=?" + " ORDER BY " + Sys_FieldGroupTable.GROUPORDER_FLD + "=?"; Utils utils = new Utils(); oconPCS = new OleDbConnection(Utils.Instance.OleDbConnectionString); ocmdPCS = new OleDbCommand(strSql, oconPCS); ocmdPCS.Parameters.Add(new OleDbParameter(Sys_FieldGroupTable.REPORTID_FLD, OleDbType.VarWChar)); ocmdPCS.Parameters[Sys_FieldGroupTable.REPORTID_FLD].Value = pstrReportID; ocmdPCS.CommandText = strSql; ocmdPCS.Connection.Open(); odrPCS = ocmdPCS.ExecuteReader(); ArrayList arrResult = new ArrayList(); while (odrPCS.Read()) { Sys_FieldGroupVO objObject = new Sys_FieldGroupVO(); objObject.FieldGroupID = int.Parse(odrPCS[Sys_FieldGroupTable.FIELDGROUPID_FLD].ToString().Trim()); objObject.GroupCode = odrPCS[Sys_FieldGroupTable.GROUPCODE_FLD].ToString().Trim(); objObject.GroupOrder = int.Parse(odrPCS[Sys_FieldGroupTable.GROUPORDER_FLD].ToString().Trim()); objObject.GroupLevel = int.Parse(odrPCS[Sys_FieldGroupTable.GROUPLEVEL_FLD].ToString().Trim()); objObject.GroupNameVN = odrPCS[Sys_FieldGroupTable.GROUPNAMEVN_FLD].ToString().Trim(); objObject.GroupNameEN = odrPCS[Sys_FieldGroupTable.GROUPNAMEEN_FLD].ToString().Trim(); objObject.GroupNameJP = odrPCS[Sys_FieldGroupTable.GROUPNAMEJP_FLD].ToString().Trim(); objObject.ReportID = odrPCS[Sys_FieldGroupTable.REPORTID_FLD].ToString().Trim(); if (odrPCS[Sys_FieldGroupTable.PARENTFIELDGROUPID_FLD] != DBNull.Value) { objObject.ParentFieldGroupID = int.Parse(odrPCS[Sys_FieldGroupTable.PARENTFIELDGROUPID_FLD].ToString().Trim()); } arrResult.Add(objObject); } arrResult.TrimToSize(); return(arrResult); } catch (OleDbException ex) { throw new PCSDBException(ErrorCode.ERROR_DB, METHOD_NAME, ex); } catch (Exception ex) { throw new PCSDBException(ErrorCode.OTHER_ERROR, METHOD_NAME, ex); } finally { if (oconPCS != null) { if (oconPCS.State != ConnectionState.Closed) { oconPCS.Close(); } } } }