示例#1
0
        //**************************************************************************
        ///    <Description>
        ///       This method uses to add data to IV_BalanceBin
        ///    </Description>
        ///    <Inputs>
        ///        IV_BalanceBinVO
        ///    </Inputs>
        ///    <Outputs>
        ///       newly inserted primarkey value
        ///    </Outputs>
        ///    <Returns>
        ///       void
        ///    </Returns>
        ///    <Authors>
        ///       Code generate
        ///    </Authors>
        ///    <History>
        ///       Thursday, October 05, 2006
        ///    </History>
        ///    <Notes>
        ///    </Notes>
        //**************************************************************************
        public void Add(object pobjObjectVO)
        {
            const string METHOD_NAME = THIS + ".Add()";

            OleDbConnection oconPCS = null;
            OleDbCommand    ocmdPCS = null;

            try
            {
                IV_BalanceBinVO objObject = (IV_BalanceBinVO)pobjObjectVO;
                string          strSql    = String.Empty;
                Utils           utils     = new Utils();
                oconPCS = new OleDbConnection(Utils.Instance.OleDbConnectionString);
                ocmdPCS = new OleDbCommand("", oconPCS);

                strSql = "INSERT INTO IV_BalanceBin("
                         + IV_BalanceBinTable.EFFECTDATE_FLD + ","
                         + IV_BalanceBinTable.OHQUANTITY_FLD + ","
                         + IV_BalanceBinTable.COMMITQUANTITY_FLD + ","
                         + IV_BalanceBinTable.PRODUCTID_FLD + ","
                         + IV_BalanceBinTable.LOCATIONID_FLD + ","
                         + IV_BalanceBinTable.BINID_FLD + ","
                         + IV_BalanceBinTable.STOCKUMID_FLD + ")"
                         + "VALUES(?,?,?,?,?,?,?)";

                ocmdPCS.Parameters.Add(new OleDbParameter(IV_BalanceBinTable.EFFECTDATE_FLD, OleDbType.Date));
                ocmdPCS.Parameters[IV_BalanceBinTable.EFFECTDATE_FLD].Value = objObject.EffectDate;

                ocmdPCS.Parameters.Add(new OleDbParameter(IV_BalanceBinTable.OHQUANTITY_FLD, OleDbType.Decimal));
                ocmdPCS.Parameters[IV_BalanceBinTable.OHQUANTITY_FLD].Value = objObject.OHQuantity;

                ocmdPCS.Parameters.Add(new OleDbParameter(IV_BalanceBinTable.COMMITQUANTITY_FLD, OleDbType.Decimal));
                ocmdPCS.Parameters[IV_BalanceBinTable.COMMITQUANTITY_FLD].Value = objObject.CommitQuantity;

                ocmdPCS.Parameters.Add(new OleDbParameter(IV_BalanceBinTable.PRODUCTID_FLD, OleDbType.Integer));
                ocmdPCS.Parameters[IV_BalanceBinTable.PRODUCTID_FLD].Value = objObject.ProductID;

                ocmdPCS.Parameters.Add(new OleDbParameter(IV_BalanceBinTable.LOCATIONID_FLD, OleDbType.Integer));
                ocmdPCS.Parameters[IV_BalanceBinTable.LOCATIONID_FLD].Value = objObject.LocationID;

                ocmdPCS.Parameters.Add(new OleDbParameter(IV_BalanceBinTable.BINID_FLD, OleDbType.Integer));
                ocmdPCS.Parameters[IV_BalanceBinTable.BINID_FLD].Value = objObject.BinID;

                ocmdPCS.Parameters.Add(new OleDbParameter(IV_BalanceBinTable.STOCKUMID_FLD, OleDbType.Integer));
                ocmdPCS.Parameters[IV_BalanceBinTable.STOCKUMID_FLD].Value = objObject.StockUMID;


                ocmdPCS.CommandText = strSql;
                ocmdPCS.Connection.Open();
                ocmdPCS.ExecuteNonQuery();
            }
            catch (OleDbException ex)
            {
                throw new PCSDBException(ErrorCode.ERROR_DB, METHOD_NAME, ex);
            }

            catch (InvalidOperationException ex)
            {
                throw new PCSDBException(ErrorCode.DUPLICATE_KEY, METHOD_NAME, ex);
            }
            catch (Exception ex)
            {
                throw new PCSDBException(ErrorCode.OTHER_ERROR, METHOD_NAME, ex);
            }

            finally
            {
                if (oconPCS != null)
                {
                    if (oconPCS.State != ConnectionState.Closed)
                    {
                        oconPCS.Close();
                    }
                }
            }
        }
示例#2
0
        //**************************************************************************
        ///    <Description>
        ///       This method uses to update data to IV_BalanceBin
        ///    </Description>
        ///    <Inputs>
        ///       IV_BalanceBinVO
        ///    </Inputs>
        ///    <Outputs>
        ///
        ///    </Outputs>
        ///    <Returns>
        ///
        ///    </Returns>
        ///    <Authors>
        ///       Code Generate
        ///    </Authors>
        ///    <History>
        ///       09-Dec-2004
        ///    </History>
        ///    <Notes>
        ///    </Notes>
        //**************************************************************************
        public void Update(object pobjObjecVO)
        {
            const string METHOD_NAME = THIS + ".Update()";

            IV_BalanceBinVO objObject = (IV_BalanceBinVO)pobjObjecVO;


            //prepare value for parameters
            OleDbConnection oconPCS = null;
            OleDbCommand    ocmdPCS = null;

            try
            {
                string strSql = String.Empty;
                Utils  utils  = new Utils();
                oconPCS = new OleDbConnection(Utils.Instance.OleDbConnectionString);
                ocmdPCS = new OleDbCommand(strSql, oconPCS);
                strSql  = "UPDATE IV_BalanceBin SET "
                          + IV_BalanceBinTable.EFFECTDATE_FLD + "=   ?" + ","
                          + IV_BalanceBinTable.OHQUANTITY_FLD + "=   ?" + ","
                          + IV_BalanceBinTable.COMMITQUANTITY_FLD + "=   ?" + ","
                          + IV_BalanceBinTable.PRODUCTID_FLD + "=   ?" + ","
                          + IV_BalanceBinTable.LOCATIONID_FLD + "=   ?" + ","
                          + IV_BalanceBinTable.BINID_FLD + "=   ?" + ","
                          + IV_BalanceBinTable.STOCKUMID_FLD + "=  ?"
                          + " WHERE " + IV_BalanceBinTable.BALANCEBINID_FLD + "= ?";

                ocmdPCS.Parameters.Add(new OleDbParameter(IV_BalanceBinTable.EFFECTDATE_FLD, OleDbType.Date));
                ocmdPCS.Parameters[IV_BalanceBinTable.EFFECTDATE_FLD].Value = objObject.EffectDate;

                ocmdPCS.Parameters.Add(new OleDbParameter(IV_BalanceBinTable.OHQUANTITY_FLD, OleDbType.Decimal));
                ocmdPCS.Parameters[IV_BalanceBinTable.OHQUANTITY_FLD].Value = objObject.OHQuantity;

                ocmdPCS.Parameters.Add(new OleDbParameter(IV_BalanceBinTable.COMMITQUANTITY_FLD, OleDbType.Decimal));
                if (objObject.CommitQuantity != 0)
                {
                    ocmdPCS.Parameters[IV_BalanceBinTable.COMMITQUANTITY_FLD].Value = objObject.CommitQuantity;
                }
                else
                {
                    ocmdPCS.Parameters[IV_BalanceBinTable.COMMITQUANTITY_FLD].Value = DBNull.Value;
                }

                ocmdPCS.Parameters.Add(new OleDbParameter(IV_BalanceBinTable.PRODUCTID_FLD, OleDbType.Integer));
                ocmdPCS.Parameters[IV_BalanceBinTable.PRODUCTID_FLD].Value = objObject.ProductID;

                ocmdPCS.Parameters.Add(new OleDbParameter(IV_BalanceBinTable.LOCATIONID_FLD, OleDbType.Integer));
                ocmdPCS.Parameters[IV_BalanceBinTable.LOCATIONID_FLD].Value = objObject.LocationID;

                ocmdPCS.Parameters.Add(new OleDbParameter(IV_BalanceBinTable.BINID_FLD, OleDbType.Integer));
                ocmdPCS.Parameters[IV_BalanceBinTable.BINID_FLD].Value = objObject.BinID;

                ocmdPCS.Parameters.Add(new OleDbParameter(IV_BalanceBinTable.STOCKUMID_FLD, OleDbType.Integer));
                if (objObject.StockUMID != 0)
                {
                    ocmdPCS.Parameters[IV_BalanceBinTable.STOCKUMID_FLD].Value = objObject.StockUMID;
                }
                else
                {
                    ocmdPCS.Parameters[IV_BalanceBinTable.STOCKUMID_FLD].Value = DBNull.Value;
                }

                ocmdPCS.Parameters.Add(new OleDbParameter(IV_BalanceBinTable.BALANCEBINID_FLD, OleDbType.Integer));
                ocmdPCS.Parameters[IV_BalanceBinTable.BALANCEBINID_FLD].Value = objObject.BalanceBinID;


                ocmdPCS.CommandText = strSql;
                ocmdPCS.Connection.Open();
                ocmdPCS.ExecuteNonQuery();
            }
            catch (OleDbException ex)
            {
                throw new PCSDBException(ErrorCode.ERROR_DB, METHOD_NAME, ex);
            }

            catch (InvalidOperationException ex)
            {
                throw new PCSDBException(ErrorCode.DUPLICATE_KEY, METHOD_NAME, ex);
            }
            catch (Exception ex)
            {
                throw new PCSDBException(ErrorCode.OTHER_ERROR, METHOD_NAME, ex);
            }

            finally
            {
                if (oconPCS != null)
                {
                    if (oconPCS.State != ConnectionState.Closed)
                    {
                        oconPCS.Close();
                    }
                }
            }
        }
示例#3
0
        //**************************************************************************
        ///    <Description>
        ///       This method uses to get data from IV_BalanceBin
        ///    </Description>
        ///    <Inputs>
        ///        ID
        ///    </Inputs>
        ///    <Outputs>
        ///       IV_BalanceBinVO
        ///    </Outputs>
        ///    <Returns>
        ///       IV_BalanceBinVO
        ///    </Returns>
        ///    <Authors>
        ///       Code Generate
        ///    </Authors>
        ///    <History>
        ///       Thursday, October 05, 2006
        ///    </History>
        ///    <Notes>
        ///    </Notes>
        //**************************************************************************
        public object GetObjectVO(int pintID)
        {
            const string METHOD_NAME = THIS + ".GetObjectVO()";
            DataSet      dstPCS      = new DataSet();

            OleDbDataReader odrPCS  = null;
            OleDbConnection oconPCS = null;
            OleDbCommand    ocmdPCS = null;

            try
            {
                string strSql = String.Empty;
                strSql = "SELECT "
                         + IV_BalanceBinTable.BALANCEBINID_FLD + ","
                         + IV_BalanceBinTable.EFFECTDATE_FLD + ","
                         + IV_BalanceBinTable.OHQUANTITY_FLD + ","
                         + IV_BalanceBinTable.COMMITQUANTITY_FLD + ","
                         + IV_BalanceBinTable.PRODUCTID_FLD + ","
                         + IV_BalanceBinTable.LOCATIONID_FLD + ","
                         + IV_BalanceBinTable.BINID_FLD + ","
                         + IV_BalanceBinTable.STOCKUMID_FLD
                         + " FROM " + IV_BalanceBinTable.TABLE_NAME
                         + " WHERE " + IV_BalanceBinTable.BALANCEBINID_FLD + "=" + pintID;

                Utils utils = new Utils();
                oconPCS = new OleDbConnection(Utils.Instance.OleDbConnectionString);
                ocmdPCS = new OleDbCommand(strSql, oconPCS);

                ocmdPCS.Connection.Open();
                odrPCS = ocmdPCS.ExecuteReader();

                IV_BalanceBinVO objObject = new IV_BalanceBinVO();

                while (odrPCS.Read())
                {
                    objObject.BalanceBinID   = int.Parse(odrPCS[IV_BalanceBinTable.BALANCEBINID_FLD].ToString());
                    objObject.EffectDate     = DateTime.Parse(odrPCS[IV_BalanceBinTable.EFFECTDATE_FLD].ToString());
                    objObject.OHQuantity     = Decimal.Parse(odrPCS[IV_BalanceBinTable.OHQUANTITY_FLD].ToString());
                    objObject.CommitQuantity = Decimal.Parse(odrPCS[IV_BalanceBinTable.COMMITQUANTITY_FLD].ToString());
                    objObject.ProductID      = int.Parse(odrPCS[IV_BalanceBinTable.PRODUCTID_FLD].ToString());
                    objObject.LocationID     = int.Parse(odrPCS[IV_BalanceBinTable.LOCATIONID_FLD].ToString());
                    objObject.BinID          = int.Parse(odrPCS[IV_BalanceBinTable.BINID_FLD].ToString());
                    objObject.StockUMID      = int.Parse(odrPCS[IV_BalanceBinTable.STOCKUMID_FLD].ToString());
                }
                return(objObject);
            }
            catch (OleDbException ex)
            {
                throw new PCSDBException(ErrorCode.ERROR_DB, METHOD_NAME, ex);
            }

            catch (Exception ex)
            {
                throw new PCSDBException(ErrorCode.OTHER_ERROR, METHOD_NAME, ex);
            }

            finally
            {
                if (oconPCS != null)
                {
                    if (oconPCS.State != ConnectionState.Closed)
                    {
                        oconPCS.Close();
                    }
                }
            }
        }