// cause a part at random to malfunction public static void CauseMalfunction(Vessel v) { // if vessel is loaded if (v.loaded) { // choose a part at random var modules = v.FindPartModulesImplementing<Malfunction>(); if (modules.Count == 0) return; var m = modules[Lib.RandomInt(modules.Count)]; // break it m.Break(); } // if vessel is not loaded else { // choose a part at random List<KeyValuePair<ProtoPartSnapshot,ProtoPartModuleSnapshot>> modules = new List<KeyValuePair<ProtoPartSnapshot,ProtoPartModuleSnapshot>>(); foreach(ProtoPartSnapshot part in v.protoVessel.protoPartSnapshots) { foreach(ProtoPartModuleSnapshot module in part.modules) { if (module.moduleName == "Malfunction") modules.Add(new KeyValuePair<ProtoPartSnapshot,ProtoPartModuleSnapshot>(part, module)); } } if (modules.Count == 0) return; var p = modules[Lib.RandomInt(modules.Count)]; var m = p.Value; // break it Malfunction.Break(v, m); } }
// fill antennas data void BuildAntennas() { // get error-correcting code factor double ecc = ECC(); // forget previous antennas antennas.Clear(); // for each vessel foreach(Vessel v in FlightGlobals.Vessels) { // skip invalid vessels if (!Lib.IsVessel(v)) continue; // store best antenna values double best_range = 0.0; double best_relay_range = 0.0; double best_relay_cost = 0.0; // get ec available double ec_amount = Lib.GetResourceAmount(v, "ElectricCharge"); // if the vessel is loaded if (v.loaded) { // choose the best antenna foreach(Antenna a in v.FindPartModulesImplementing<Antenna>()) { double range = Range(a.scope, a.penalty, ecc); best_range = Math.Max(best_range, range); if (a.relay && range > best_relay_range && ec_amount >= a.relay_cost * TimeWarp.deltaTime) { best_relay_range = range; best_relay_cost = a.relay_cost; } } } // if the vessel isn't loaded else { // choose the best antenna foreach(ProtoPartSnapshot p in v.protoVessel.protoPartSnapshots) { foreach(ProtoPartModuleSnapshot m in p.modules) { if (m.moduleName == "Antenna") { double range = Range(m.moduleValues.GetValue("scope"), Malfunction.Penalty(p), ecc); double relay_cost = Lib.GetProtoValue<double>(m, "relay_cost"); bool relay = Lib.GetProtoValue<bool>(m, "relay"); best_range = Math.Max(best_range, range); if (relay && range > best_relay_range && ec_amount >= relay_cost * TimeWarp.deltaTime) { best_relay_range = range; best_relay_cost = relay_cost; } } } } } // add antenna data antennas.Add(v.id, new antenna_data(Lib.VesselPosition(v), best_range, best_relay_range, best_relay_cost)); } }
void render_reliability(reliability_data reliability, crew_data crew) { render_title("RELIABILITY"); render_content("malfunctions", Lib.ValueOrNone(reliability.failure_year, "/y"), "per-component average case estimate"); render_content("redundancy", reliability.redundancy); render_content("quality", Malfunction.QualityToString(reliability.quality), "manufacturing quality"); render_content("engineer", crew.engineer ? "yes" : "no"); render_space(); }
public static reliability_data analyze_reliability(List<Part> parts, ec_data ec, signal_data signal) { // store data reliability_data reliability = new reliability_data(); // get manufacturing quality reliability.quality = Malfunction.DeduceQuality(); // count parts that can fail uint components = 0; // scan the parts foreach(Part p in parts) { // for each module foreach(PartModule m in p.Modules) { // malfunctions if (m.moduleName == "Malfunction") { Malfunction mm = (Malfunction)m; ++components; double avg_lifetime = (mm.min_lifetime + mm.max_lifetime) * 0.5 * reliability.quality; reliability.failure_year += (60.0 * 60.0 * Lib.HoursInDay() * Lib.DaysInYear()) / avg_lifetime; } } } // calculate reliability data if (components > 0) reliability.failure_year /= (double)components; double ec_redundancy = ec.best_ec_generator < ec.generated_sunlight ? (ec.generated_sunlight - ec.best_ec_generator) / ec.generated_sunlight : 0.0; double antenna_redundancy = signal.second_best_range > 0.0 ? signal.second_best_range / signal.range : 0.0; List<string> redundancies = new List<string>(); if (ec_redundancy >= 0.5) redundancies.Add("ec"); if (antenna_redundancy >= 0.99) redundancies.Add("antenna"); if (redundancies.Count == 0) redundancies.Add("none"); reliability.redundancy = String.Join(", ", redundancies.ToArray()); // return data return reliability; }
GUIContent indicator_reliability(Vessel v) { GUIContent state = new GUIContent(); uint max_malfunctions = Malfunction.MaxMalfunction(v); if (max_malfunctions == 0) { state.image = icon_malfunction_nominal; state.tooltip = "No malfunctions"; } else if (max_malfunctions == 1) { state.image = icon_malfunction_warning; state.tooltip = "Minor malfunctions"; } else { state.image = icon_malfunction_danger; state.tooltip = "Major malfunctions"; } double avg_quality = Malfunction.AverageQuality(v); if (avg_quality > 0.0) state.tooltip += "\n<i>Quality: " + Malfunction.QualityToString(avg_quality) + "</i>"; return state; }
void Breakdown(Vessel v, ProtoCrewMember c) { // constants const double food_penality = 0.2; // proportion of food lost on 'depressed' const double oxygen_penality = 0.2; // proportion of oxygen lost on 'wrong_valve' // get info double food_amount = Lib.GetResourceAmount(v, "Food"); double oxygen_amount = Lib.GetResourceAmount(v, "Oxygen"); // compile list of events with condition satisfied List<KerbalBreakdown> events = new List<KerbalBreakdown>(); events.Add(KerbalBreakdown.mumbling); //< do nothing, here so there is always something that can happen if (Lib.CrewCount(v) > 1) events.Add(KerbalBreakdown.argument); //< do nothing, add some variation to messages if (Lib.HasData(v)) events.Add(KerbalBreakdown.fat_finger); if (Malfunction.CanMalfunction(v)) events.Add(KerbalBreakdown.rage); if (food_amount > double.Epsilon) events.Add(KerbalBreakdown.depressed); if (oxygen_amount > double.Epsilon) events.Add(KerbalBreakdown.wrong_valve); // choose a breakdown event KerbalBreakdown breakdown = events[Lib.RandomInt(events.Count)]; // post message first so this one is shown before malfunction message Message.Post(Severity.breakdown, KerbalEvent.stress, v, c, breakdown); // trigger the event switch(breakdown) { case KerbalBreakdown.mumbling: break; // do nothing case KerbalBreakdown.argument: break; // do nothing case KerbalBreakdown.fat_finger: Lib.RemoveData(v); break; case KerbalBreakdown.rage: Malfunction.CauseMalfunction(v); break; case KerbalBreakdown.depressed: Lib.RequestResource(v, "Food", food_amount * food_penality); break; case KerbalBreakdown.wrong_valve: Lib.RequestResource(v, "Oxygen", oxygen_amount * oxygen_penality); break; } }
// called at every simulation step public void FixedUpdate() { // do nothing if paused if (Lib.IsPaused()) return; // do nothing if DB isn't ready if (!DB.Ready()) return; // for each vessel foreach(Vessel vessel in FlightGlobals.Vessels) { // skip invalid vessels if (!Lib.IsVessel(vessel)) continue; // skip loaded vessels if (vessel.loaded) continue; // get vessel data from the db vessel_data vd = DB.VesselData(vessel.id); // get vessel info from the cache vessel_info info = Cache.VesselInfo(vessel); // calculate atmospheric factor (proportion of flux not blocked by atmosphere) double atmo_factor = Sim.AtmosphereFactor(vessel.mainBody, info.position, info.sun_dir); // for each part foreach(ProtoPartSnapshot part in vessel.protoVessel.protoPartSnapshots) { // get part prefab (required for module properties) Part part_prefab = PartLoader.getPartInfoByName(part.partName).partPrefab; // store index of ModuleResourceConverter to process // rationale: a part can contain multiple resource converters int converter_index = 0; // for each module foreach(ProtoPartModuleSnapshot module in part.modules) { // something weird is going on, skip this if (!part_prefab.Modules.Contains(module.moduleName)) continue; // command module if (module.moduleName == "ModuleCommand") { // get module from prefab ModuleCommand command = part_prefab.Modules.GetModules<ModuleCommand>()[0]; // do not consume if this is a MCM with no crew // rationale: for consistency, the game doesn't consume resources for MCM without crew in loaded vessels // this make some sense: you left a vessel with some battery and nobody on board, you expect it to not consume EC if (command.minimumCrew == 0 || part.protoModuleCrew.Count > 0) { // for each input resource foreach(ModuleResource ir in command.inputResources) { // consume the resource Lib.RequestResource(vessel, ir.name, ir.rate * TimeWarp.fixedDeltaTime); } } } // solar panel else if (module.moduleName == "ModuleDeployableSolarPanel") { // determine if extended bool extended = module.moduleValues.GetValue("stateString") == ModuleDeployableSolarPanel.panelStates.EXTENDED.ToString(); // if in sunlight and extended if (info.sunlight && extended) { // get module from prefab ModuleDeployableSolarPanel panel = part_prefab.Modules.GetModules<ModuleDeployableSolarPanel>()[0]; // produce electric charge Lib.RequestResource(vessel, "ElectricCharge", -PanelOutput(vessel, part, panel, info.sun_dir, info.sun_dist, atmo_factor) * TimeWarp.fixedDeltaTime * Malfunction.Penalty(part)); } } // generator // note: assume generators require all input else if (module.moduleName == "ModuleGenerator") { // determine if active bool activated = Convert.ToBoolean(module.moduleValues.GetValue("generatorIsActive")); // if active if (activated) { // get module from prefab ModuleGenerator generator = part_prefab.Modules.GetModules<ModuleGenerator>()[0]; // determine if vessel is full of all output resources bool full = true; foreach(var or in generator.outputList) { double amount = Lib.GetResourceAmount(vessel, or.name); double capacity = Lib.GetResourceCapacity(vessel, or.name); double perc = capacity > 0.0 ? amount / capacity : 0.0; full &= (perc >= 1.0 - double.Epsilon); } // if not full if (!full) { // calculate worst required resource percentual double worst_input = 1.0; foreach(var ir in generator.inputList) { double required = ir.rate * TimeWarp.fixedDeltaTime; double amount = Lib.GetResourceAmount(vessel, ir.name); worst_input = Math.Min(worst_input, amount / required); } // for each input resource foreach(var ir in generator.inputList) { // consume the resource Lib.RequestResource(vessel, ir.name, ir.rate * worst_input * TimeWarp.fixedDeltaTime); } // for each output resource foreach(var or in generator.outputList) { // produce the resource Lib.RequestResource(vessel, or.name, -or.rate * worst_input * TimeWarp.fixedDeltaTime * Malfunction.Penalty(part)); } } } } // converter // note: support multiple resource converters // note: ignore stock temperature mechanic of converters // note: ignore autoshutdown // note: ignore crew experience bonus (seem that stock ignore it too) // note: 'undo' stock behaviour by forcing lastUpdateTime to now (to minimize overlapping calculations from this and stock post-facto simulation) // note: support PlanetaryBaseSystem converters // note: support NearFuture reactors else if (module.moduleName == "ModuleResourceConverter" || module.moduleName == "ModuleKPBSConverter" || module.moduleName == "FissionReactor") { // get module from prefab ModuleResourceConverter converter = part_prefab.Modules.GetModules<ModuleResourceConverter>()[converter_index++]; // determine if active bool activated = Convert.ToBoolean(module.moduleValues.GetValue("IsActivated")); // if active if (activated) { // determine if vessel is full of all output resources bool full = true; foreach(var or in converter.outputList) { double amount = Lib.GetResourceAmount(vessel, or.ResourceName); double capacity = Lib.GetResourceCapacity(vessel, or.ResourceName); double perc = capacity > 0.0 ? amount / capacity : 0.0; full &= (perc >= converter.FillAmount - double.Epsilon); } // if not full if (!full) { // calculate worst required resource percentual double worst_input = 1.0; foreach(var ir in converter.inputList) { double required = ir.Ratio * TimeWarp.fixedDeltaTime; double amount = Lib.GetResourceAmount(vessel, ir.ResourceName); worst_input = Math.Min(worst_input, amount / required); } // for each input resource foreach(var ir in converter.inputList) { // consume the resource Lib.RequestResource(vessel, ir.ResourceName, ir.Ratio * worst_input * TimeWarp.fixedDeltaTime); } // for each output resource foreach(var or in converter.outputList) { // produce the resource Lib.RequestResource(vessel, or.ResourceName, -or.Ratio * worst_input * TimeWarp.fixedDeltaTime * Malfunction.Penalty(part)); } } // undo stock behaviour by forcing last_update_time to now module.moduleValues.SetValue("lastUpdateTime", Planetarium.GetUniversalTime().ToString()); } } // drill // note: ignore stock temperature mechanic of harvesters // note: ignore autoshutdown // note: ignore depletion (stock seem to do the same) // note: 'undo' stock behaviour by forcing lastUpdateTime to now (to minimize overlapping calculations from this and stock post-facto simulation) else if (module.moduleName == "ModuleResourceHarvester") { // determine if active bool activated = Convert.ToBoolean(module.moduleValues.GetValue("IsActivated")); // if active if (activated) { // get module from prefab ModuleResourceHarvester harvester = part_prefab.Modules.GetModules<ModuleResourceHarvester>()[0]; // [disabled] reason: not working // deduce crew bonus /*double experience_bonus = 0.0; if (harvester.UseSpecialistBonus) { foreach(ProtoCrewMember c in vessel.protoVessel.GetVesselCrew()) { experience_bonus = Math.Max(experience_bonus, (c.trait == harvester.Specialty) ? (double)c.experienceLevel : 0.0); } }*/ const double crew_bonus = 1.0; //harvester.SpecialistBonusBase + (experience_bonus + 1.0) * harvester.SpecialistEfficiencyFactor; // detect amount of ore in the ground AbundanceRequest request = new AbundanceRequest { Altitude = vessel.altitude, BodyId = vessel.mainBody.flightGlobalsIndex, CheckForLock = false, Latitude = vessel.latitude, Longitude = vessel.longitude, ResourceType = (HarvestTypes)harvester.HarvesterType, ResourceName = harvester.ResourceName }; double abundance = ResourceMap.Instance.GetAbundance(request); // if there is actually something (should be if active when unloaded) if (abundance > harvester.HarvestThreshold) { // calculate worst required resource percentual double worst_input = 1.0; foreach(var ir in harvester.inputList) { double required = ir.Ratio * TimeWarp.fixedDeltaTime; double amount = Lib.GetResourceAmount(vessel, ir.ResourceName); worst_input = Math.Min(worst_input, amount / required); } // for each input resource foreach(var ir in harvester.inputList) { // consume the resource Lib.RequestResource(vessel, ir.ResourceName, ir.Ratio * worst_input * TimeWarp.fixedDeltaTime); } // determine resource produced double res = abundance * harvester.Efficiency * crew_bonus * worst_input * Malfunction.Penalty(part); // accumulate ore Lib.RequestResource(vessel, harvester.ResourceName, -res * TimeWarp.fixedDeltaTime); } // undo stock behaviour by forcing last_update_time to now module.moduleValues.SetValue("lastUpdateTime", Planetarium.GetUniversalTime().ToString()); } } // asteroid drill // note: untested // note: ignore stock temperature mechanic of asteroid drills // note: ignore autoshutdown // note: 'undo' stock behaviour by forcing lastUpdateTime to now (to minimize overlapping calculations from this and stock post-facto simulation) else if (module.moduleName == "ModuleAsteroidDrill") { // determine if active bool activated = Convert.ToBoolean(module.moduleValues.GetValue("IsActivated")); // if active if (activated) { // get module from prefab ModuleAsteroidDrill asteroid_drill = part_prefab.Modules.GetModules<ModuleAsteroidDrill>()[0]; // [disabled] reason: not working // deduce crew bonus /*double experience_bonus = 0.0; if (asteroid_drill.UseSpecialistBonus) { foreach(ProtoCrewMember c in vessel.protoVessel.GetVesselCrew()) { experience_bonus = Math.Max(experience_bonus, (c.trait == asteroid_drill.Specialty) ? (double)c.experienceLevel : 0.0); } }*/ const double crew_bonus = 1.0; //asteroid_drill.SpecialistBonusBase + (experience_bonus + 1.0) * asteroid_drill.SpecialistEfficiencyFactor; // get asteroid data ProtoPartModuleSnapshot asteroid_info = null; ProtoPartModuleSnapshot asteroid_resource = null; foreach(ProtoPartSnapshot p in vessel.protoVessel.protoPartSnapshots) { if (asteroid_info == null) asteroid_info = p.modules.Find(k => k.moduleName == "ModuleAsteroidInfo"); if (asteroid_resource == null) asteroid_resource = p.modules.Find(k => k.moduleName == "ModuleAsteroidResource"); } // if there is actually an asteroid attached to this active asteroid drill (it should) if (asteroid_info != null && asteroid_resource != null) { // get some data double mass_threshold = Convert.ToDouble(asteroid_info.moduleValues.GetValue("massThresholdVal")); double mass = Convert.ToDouble(asteroid_info.moduleValues.GetValue("currentMassVal")); double abundance = Convert.ToDouble(asteroid_resource.moduleValues.GetValue("abundance")); string res_name = asteroid_resource.moduleValues.GetValue("resourceName"); double res_density = PartResourceLibrary.Instance.GetDefinition(res_name).density; // if asteroid isn't depleted if (mass > mass_threshold && abundance > double.Epsilon) { // consume EC double ec_required = asteroid_drill.PowerConsumption * TimeWarp.fixedDeltaTime; double ec_consumed = Lib.RequestResource(vessel, "ElectricCharge", ec_required); double ec_ratio = ec_consumed / ec_required; // determine resource extracted double res_amount = abundance * asteroid_drill.Efficiency * crew_bonus * ec_ratio * TimeWarp.fixedDeltaTime; // produce mined resource Lib.RequestResource(vessel, res_name, -res_amount); // consume asteroid mass asteroid_info.moduleValues.SetValue("currentMassVal", (mass - res_density * res_amount).ToString()); } } // undo stock behaviour by forcing last_update_time to now module.moduleValues.SetValue("lastUpdateTime", Planetarium.GetUniversalTime().ToString()); } } // science lab // note: we are only simulating the EC consumption // note: there is no easy way to 'stop' the lab when there isn't enough EC else if (module.moduleName == "ModuleScienceConverter") { // get module from prefab ModuleScienceConverter lab = part_prefab.Modules.GetModules<ModuleScienceConverter>()[0]; // determine if active bool activated = Convert.ToBoolean(module.moduleValues.GetValue("IsActivated")); // if active if (activated) { Lib.RequestResource(vessel, "ElectricCharge", lab.powerRequirement * TimeWarp.fixedDeltaTime); } } // SCANSAT support else if (module.moduleName == "SCANsat" || module.moduleName == "ModuleSCANresourceScanner") { // get ec consumption rate PartModule scansat = part_prefab.Modules[module.moduleName]; double power = Lib.ReflectionValue<float>(scansat, "power"); double ec_required = power * TimeWarp.fixedDeltaTime; bool is_scanning = Lib.GetProtoValue<bool>(module, "scanning"); bool was_disabled = vd.scansat_id.Contains(part.flightID); // if its scanning if (Lib.GetProtoValue<bool>(module, "scanning")) { // consume ec double ec_consumed = Lib.RequestResource(vessel, "ElectricCharge", ec_required); // if there isn't enough ec if (ec_consumed < ec_required * 0.99 && ec_required > double.Epsilon) { // unregister scanner SCANsat.stopScanner(vessel, module, part_prefab); // remember disabled scanner vd.scansat_id.Add(part.flightID); // give the user some feedback if (DB.VesselData(vessel.id).cfg_ec == 1) Message.Post("SCANsat sensor was disabled on <b>" + vessel.vesselName + "</b>"); } } // if it was disabled else if (vd.scansat_id.Contains(part.flightID)) { // if there is enough ec double ec_amount = Lib.GetResourceAmount(vessel, "ElectricCharge"); double ec_capacity = Lib.GetResourceCapacity(vessel, "ElectricCharge"); if (ec_capacity > double.Epsilon && ec_amount / ec_capacity > 0.25) //< re-enable at 25% EC { // re-enable the scanner SCANsat.resumeScanner(vessel, module, part_prefab); // give the user some feedback if (DB.VesselData(vessel.id).cfg_ec == 1) Message.Post("SCANsat sensor resumed operations on <b>" + vessel.vesselName + "</b>"); } } // forget active scanners if (Lib.GetProtoValue<bool>(module, "scanning")) vd.scansat_id.Remove(part.flightID); } // NearFutureSolar support // note: we assume deployed, this is a current limitation else if (module.moduleName == "ModuleCurvedSolarPanel") { // if in sunlight if (info.sunlight) { PartModule curved_panel = part_prefab.Modules[module.moduleName]; double output = CurvedPanelOutput(vessel, part, part_prefab, curved_panel, info.sun_dir, info.sun_dist, atmo_factor) * Malfunction.Penalty(part); Lib.RequestResource(vessel, "ElectricCharge", -output * TimeWarp.fixedDeltaTime); } } // NearFutureElectrical support // note: fission generator ignore heat // note: radioisotope generator doesn't support easy mode else if (module.moduleName == "FissionGenerator") { PartModule generator = part_prefab.Modules[module.moduleName]; double power = Lib.ReflectionValue<float>(generator, "PowerGeneration"); // get fission reactor tweakable, will default to 1.0 for other modules var reactor = part.modules.Find(k => k.moduleName == "FissionReactor"); double tweakable = reactor == null ? 1.0 : Lib.ConfigValue(reactor.moduleValues, "CurrentPowerPercent", 100.0) * 0.01; Lib.RequestResource(vessel, "ElectricCharge", -power * tweakable * TimeWarp.fixedDeltaTime); } else if (module.moduleName == "ModuleRadioisotopeGenerator") { double mission_time = vessel.missionTime / (3600.0 * Lib.HoursInDay() * Lib.DaysInYear()); PartModule generator = part_prefab.Modules[module.moduleName]; double half_life = Lib.ReflectionValue<float>(generator, "HalfLife"); double remaining = Math.Pow(2.0, (-mission_time) / half_life); double power = Lib.ReflectionValue<float>(generator, "BasePower"); Lib.RequestResource(vessel, "ElectricCharge", -power * remaining * TimeWarp.fixedDeltaTime); } // KERBALISM modules else if (module.moduleName == "Scrubber") { Scrubber.BackgroundUpdate(vessel, part.flightID); } else if (module.moduleName == "Greenhouse") { Greenhouse.BackgroundUpdate(vessel, part.flightID); } else if (module.moduleName == "GravityRing") { GravityRing.BackgroundUpdate(vessel, part.flightID); } else if (module.moduleName == "Malfunction") { Malfunction.BackgroundUpdate(vessel, part.flightID); } } } } }
// called at every simulation step public void FixedUpdate() { // do nothing if paused if (Lib.IsPaused()) return; // do nothing if DB isn't ready if (!DB.Ready()) return; // for each vessel foreach(Vessel vessel in FlightGlobals.Vessels) { // skip invalid vessels if (!Lib.IsVessel(vessel)) continue; // skip loaded vessels if (vessel.loaded) continue; // get vessel info from the cache vessel_info info = Cache.VesselInfo(vessel); // calculate atmospheric factor (proportion of flux not blocked by atmosphere) double atmo_factor = Sim.AtmosphereFactor(vessel.mainBody, info.position, info.sun_dir); // for each part foreach(ProtoPartSnapshot part in vessel.protoVessel.protoPartSnapshots) { // get part prefab (required for module properties) Part part_prefab = PartLoader.getPartInfoByName(part.partName).partPrefab; // store index of ModuleResourceConverter to process // rationale: a part can contain multiple resource converters int converter_index = 0; // for each module foreach(ProtoPartModuleSnapshot module in part.modules) { // command module if (module.moduleName == "ModuleCommand") { // get module from prefab ModuleCommand command = part_prefab.Modules.GetModules<ModuleCommand>()[0]; // do not consume if this is a MCM with no crew // rationale: for consistency, the game doesn't consume resources for MCM without crew in loaded vessels // this make some sense: you left a vessel with some battery and nobody on board, you expect it to not consume EC if (command.minimumCrew == 0 || part.protoModuleCrew.Count > 0) { // for each input resource foreach(ModuleResource ir in command.inputResources) { // consume the resource Lib.RequestResource(vessel, ir.name, ir.rate * TimeWarp.fixedDeltaTime); } } } // solar panel else if (module.moduleName == "ModuleDeployableSolarPanel") { // determine if extended bool extended = module.moduleValues.GetValue("stateString") == ModuleDeployableSolarPanel.panelStates.EXTENDED.ToString(); // if in sunlight and extended if (info.sunlight && extended) { // get module from prefab ModuleDeployableSolarPanel panel = part_prefab.Modules.GetModules<ModuleDeployableSolarPanel>()[0]; // produce electric charge Lib.RequestResource(vessel, "ElectricCharge", -PanelOutput(vessel, part, panel, info.sun_dir, info.sun_dist, atmo_factor) * TimeWarp.fixedDeltaTime * Malfunction.Penalty(part)); } } // generator // note: assume generators require all input else if (module.moduleName == "ModuleGenerator") { // determine if active bool activated = Convert.ToBoolean(module.moduleValues.GetValue("generatorIsActive")); // if active if (activated) { // get module from prefab ModuleGenerator generator = part_prefab.Modules.GetModules<ModuleGenerator>()[0]; // determine if vessel is full of all output resources bool full = true; foreach(var or in generator.outputList) { double amount = Lib.GetResourceAmount(vessel, or.name); double capacity = Lib.GetResourceCapacity(vessel, or.name); double perc = capacity > 0.0 ? amount / capacity : 0.0; full &= (perc >= 1.0 - double.Epsilon); } // if not full if (!full) { // calculate worst required resource percentual double worst_input = 1.0; foreach(var ir in generator.inputList) { double required = ir.rate * TimeWarp.fixedDeltaTime; double amount = Lib.GetResourceAmount(vessel, ir.name); worst_input = Math.Min(worst_input, amount / required); } // for each input resource foreach(var ir in generator.inputList) { // consume the resource Lib.RequestResource(vessel, ir.name, ir.rate * worst_input * TimeWarp.fixedDeltaTime); } // for each output resource foreach(var or in generator.outputList) { // produce the resource Lib.RequestResource(vessel, or.name, -or.rate * worst_input * TimeWarp.fixedDeltaTime * Malfunction.Penalty(part)); } } } } // converter // note: support multiple resource converters // note: ignore stock temperature mechanic of converters // note: ignore autoshutdown // note: ignore crew experience bonus (seem that stock ignore it too) // note: 'undo' stock behaviour by forcing lastUpdateTime to now (to minimize overlapping calculations from this and stock post-facto simulation) else if (module.moduleName == "ModuleResourceConverter") { // determine if active bool activated = Convert.ToBoolean(module.moduleValues.GetValue("IsActivated")); // if active if (activated) { // get module from prefab ModuleResourceConverter converter = part_prefab.Modules.GetModules<ModuleResourceConverter>()[converter_index++]; // determine if vessel is full of all output resources bool full = true; foreach(var or in converter.outputList) { double amount = Lib.GetResourceAmount(vessel, or.ResourceName); double capacity = Lib.GetResourceCapacity(vessel, or.ResourceName); double perc = capacity > 0.0 ? amount / capacity : 0.0; full &= (perc >= converter.FillAmount - double.Epsilon); } // if not full if (!full) { // calculate worst required resource percentual double worst_input = 1.0; foreach(var ir in converter.inputList) { double required = ir.Ratio * TimeWarp.fixedDeltaTime; double amount = Lib.GetResourceAmount(vessel, ir.ResourceName); worst_input = Math.Min(worst_input, amount / required); } // for each input resource foreach(var ir in converter.inputList) { // consume the resource Lib.RequestResource(vessel, ir.ResourceName, ir.Ratio * worst_input * TimeWarp.fixedDeltaTime); } // for each output resource foreach(var or in converter.outputList) { // produce the resource Lib.RequestResource(vessel, or.ResourceName, -or.Ratio * worst_input * TimeWarp.fixedDeltaTime * Malfunction.Penalty(part)); } } // undo stock behaviour by forcing last_update_time to now module.moduleValues.SetValue("lastUpdateTime", Planetarium.GetUniversalTime().ToString()); } } // drill // note: ignore stock temperature mechanic of harvesters // note: ignore autoshutdown // note: ignore depletion (stock seem to do the same) // note: 'undo' stock behaviour by forcing lastUpdateTime to now (to minimize overlapping calculations from this and stock post-facto simulation) else if (module.moduleName == "ModuleResourceHarvester") { // determine if active bool activated = Convert.ToBoolean(module.moduleValues.GetValue("IsActivated")); // if active if (activated) { // get module from prefab ModuleResourceHarvester harvester = part_prefab.Modules.GetModules<ModuleResourceHarvester>()[0]; // deduce crew bonus double experience_bonus = 0.0; if (harvester.UseSpecialistBonus) { foreach(ProtoCrewMember c in vessel.protoVessel.GetVesselCrew()) { experience_bonus = Math.Max(experience_bonus, (c.trait == harvester.Specialty) ? (double)c.experienceLevel : 0.0); } } double crew_bonus = harvester.SpecialistBonusBase + (experience_bonus + 1.0) * harvester.SpecialistEfficiencyFactor; // detect amount of ore in the ground AbundanceRequest request = new AbundanceRequest { Altitude = vessel.altitude, BodyId = vessel.mainBody.flightGlobalsIndex, CheckForLock = false, Latitude = vessel.latitude, Longitude = vessel.longitude, ResourceType = (HarvestTypes)harvester.HarvesterType, ResourceName = harvester.ResourceName }; double abundance = ResourceMap.Instance.GetAbundance(request); // if there is actually something (should be if active when unloaded) if (abundance > harvester.HarvestThreshold) { // calculate worst required resource percentual double worst_input = 1.0; foreach(var ir in harvester.inputList) { double required = ir.Ratio * TimeWarp.fixedDeltaTime; double amount = Lib.GetResourceAmount(vessel, ir.ResourceName); worst_input = Math.Min(worst_input, amount / required); } // for each input resource foreach(var ir in harvester.inputList) { // consume the resource Lib.RequestResource(vessel, ir.ResourceName, ir.Ratio * worst_input * TimeWarp.fixedDeltaTime); } // determine resource produced double res = abundance * harvester.Efficiency * crew_bonus * worst_input * Malfunction.Penalty(part); // accumulate ore Lib.RequestResource(vessel, harvester.ResourceName, -res * TimeWarp.fixedDeltaTime); } // undo stock behaviour by forcing last_update_time to now module.moduleValues.SetValue("lastUpdateTime", Planetarium.GetUniversalTime().ToString()); } } // asteroid drill // note: untested // note: ignore stock temperature mechanic of asteroid drills // note: ignore autoshutdown // note: 'undo' stock behaviour by forcing lastUpdateTime to now (to minimize overlapping calculations from this and stock post-facto simulation) else if (module.moduleName == "ModuleAsteroidDrill") { // determine if active bool activated = Convert.ToBoolean(module.moduleValues.GetValue("IsActivated")); // if active if (activated) { // get module from prefab ModuleAsteroidDrill asteroid_drill = part_prefab.Modules.GetModules<ModuleAsteroidDrill>()[0]; // deduce crew bonus double experience_bonus = 0.0; if (asteroid_drill.UseSpecialistBonus) { foreach(ProtoCrewMember c in vessel.protoVessel.GetVesselCrew()) { experience_bonus = Math.Max(experience_bonus, (c.trait == asteroid_drill.Specialty) ? (double)c.experienceLevel : 0.0); } } double crew_bonus = asteroid_drill.SpecialistBonusBase + (experience_bonus + 1.0) * asteroid_drill.SpecialistEfficiencyFactor; // get asteroid data ProtoPartModuleSnapshot asteroid_info = null; ProtoPartModuleSnapshot asteroid_resource = null; foreach(ProtoPartSnapshot p in vessel.protoVessel.protoPartSnapshots) { if (asteroid_info == null) asteroid_info = p.modules.Find(k => k.moduleName == "ModuleAsteroidInfo"); if (asteroid_resource == null) asteroid_resource = p.modules.Find(k => k.moduleName == "ModuleAsteroidResource"); } // if there is actually an asteroid attached to this active asteroid drill (it should) if (asteroid_info != null && asteroid_resource != null) { // get some data double mass_threshold = Convert.ToDouble(asteroid_info.moduleValues.GetValue("massThresholdVal")); double mass = Convert.ToDouble(asteroid_info.moduleValues.GetValue("currentMassVal")); double abundance = Convert.ToDouble(asteroid_resource.moduleValues.GetValue("abundance")); string res_name = asteroid_resource.moduleValues.GetValue("resourceName"); double res_density = PartResourceLibrary.Instance.GetDefinition(res_name).density; // if asteroid isn't depleted if (mass > mass_threshold && abundance > double.Epsilon) { // consume EC double ec_required = asteroid_drill.PowerConsumption * TimeWarp.fixedDeltaTime; double ec_consumed = Lib.RequestResource(vessel, "ElectricCharge", ec_required); double ec_ratio = ec_consumed / ec_required; // determine resource extracted double res_amount = abundance * asteroid_drill.Efficiency * crew_bonus * ec_ratio * TimeWarp.fixedDeltaTime; // produce mined resource Lib.RequestResource(vessel, res_name, -res_amount); // consume asteroid mass asteroid_info.moduleValues.SetValue("currentMassVal", (mass - res_density * res_amount).ToString()); } } // undo stock behaviour by forcing last_update_time to now module.moduleValues.SetValue("lastUpdateTime", Planetarium.GetUniversalTime().ToString()); } } // SCANSAT support (new version) // TODO: enable better SCANsat support /*else if (module.moduleName == "SCANsat" || module.moduleName == "ModuleSCANresourceScanner") { // get ec consumption rate PartModule scansat = part_prefab.Modules[module.moduleName]; double power = Lib.ReflectionValue<float>(scansat, "power"); double ec_required = power * TimeWarp.fixedDeltaTime; // if it was scanning if (SCANsat.wasScanning(module)) { // if there is enough ec double ec_amount = Lib.GetResourceAmount(vessel, "ElectricCharge"); double ec_capacity = Lib.GetResourceCapacity(vessel, "ElectricCharge"); if (ec_capacity > double.Epsilon && ec_amount / ec_capacity > 0.15) //< re-enable at 15% EC { // re-enable the scanner SCANsat.resumeScanner(vessel, module, part_prefab); // give the user some feedback if (DB.VesselData(vessel.id).cfg_ec == 1) Message.Post(Severity.relax, "SCANsat> sensor on <b>" + vessel.vesselName + "</b> resumed operations", "we got enough ElectricCharge"); } } // if it is scanning if (SCANsat.isScanning(module)) { // consume ec double ec_consumed = Lib.RequestResource(vessel, "ElectricCharge", ec_required); // if there isn't enough ec if (ec_consumed < ec_required * 0.99 && ec_required > double.Epsilon) { // unregister scanner, and remember it SCANsat.stopScanner(vessel, module, part_prefab); // give the user some feedback if (DB.VesselData(vessel.id).cfg_ec == 1) Message.Post(Severity.warning, "SCANsat sensor was disabled on <b>" + vessel.vesselName + "</b>", "for lack of ElectricCharge"); } } }*/ // SCANSAT support (old version) // note: this one doesn't support re-activation, is a bit slower and less clean // waiting for DMagic to fix a little bug else if (module.moduleName == "SCANsat" || module.moduleName == "ModuleSCANresourceScanner") { // determine if scanning bool scanning = Convert.ToBoolean(module.moduleValues.GetValue("scanning")); // consume ec if (scanning) { // get ec consumption PartModule scansat = part_prefab.Modules[module.moduleName]; double power = Lib.ReflectionValue<float>(scansat, "power"); // consume ec double ec_required = power * TimeWarp.fixedDeltaTime; double ec_consumed = Lib.RequestResource(vessel, "ElectricCharge", ec_required); // if there isn't enough ec if (ec_consumed < ec_required * 0.99 && ec_required > double.Epsilon) { // unregister scanner using reflection foreach(var a in AssemblyLoader.loadedAssemblies) { if (a.name == "SCANsat") { Type controller_type = a.assembly.GetType("SCANsat.SCANcontroller"); System.Object controller = controller_type.GetProperty("controller", BindingFlags.Public | BindingFlags.Static).GetValue(null, null); controller_type.InvokeMember("removeVessel", BindingFlags.InvokeMethod | BindingFlags.NonPublic | BindingFlags.Instance, null, controller, new System.Object[]{vessel}); } } // disable scanning module.moduleValues.SetValue("scanning", false.ToString()); // give the user some feedback if (DB.VesselData(vessel.id).cfg_ec == 1) Message.Post(Severity.warning, "SCANsat sensor was disabled on <b>" + vessel.vesselName + "</b>", "for lack of ElectricCharge"); } } } // NearFutureSolar support // note: we assume deployed, this is a current limitation else if (module.moduleName == "ModuleCurvedSolarPanel") { // [unused] determine if extended //string state = module.moduleValues.GetValue("SavedState"); //bool extended = state == ModuleDeployableSolarPanel.panelStates.EXTENDED.ToString(); // if in sunlight if (info.sunlight) { // produce electric charge double output = CurvedPanelOutput(vessel, part, part_prefab, info.sun_dir, info.sun_dist, atmo_factor) * Malfunction.Penalty(part); Lib.RequestResource(vessel, "ElectricCharge", -output * TimeWarp.fixedDeltaTime); } } // KERBALISM modules else if (module.moduleName == "Scrubber") { Scrubber.BackgroundUpdate(vessel, part.flightID); } else if (module.moduleName == "Greenhouse") { Greenhouse.BackgroundUpdate(vessel, part.flightID); } else if (module.moduleName == "Malfunction") { Malfunction.BackgroundUpdate(vessel, part.flightID); } } } } }