示例#1
0
        public static PGStarMatch[] GetStarMatchByName(string sysname)
        {
            if (SystemsByName.ContainsKey(sysname))
            {
                return(SystemsByName[sysname].Select(i => SystemsById[i]).ToArray());
            }
            else
            {
                int                index     = 0;
                int                starclass = 0;
                ByteXYZ            blkcoords = new ByteXYZ();
                int[]              coords    = null;
                HandAuthoredSector sector    = null;

                string regionname = GetProcGenRegionNameFromSystemName(sysname, out index, out starclass, ref blkcoords);

                if (regionname != null)
                {
                    sector = HandAuthoredSectors.Sectors.FindSector(regionname)?.First();
                    if (sector != null)
                    {
                        int[] basecoords = sector.GetBaseBlockCoords(starclass);
                        coords = new int[]
                        {
                            basecoords[0] + blkcoords.X,
                            basecoords[1] + blkcoords.Y,
                            basecoords[2] + blkcoords.Z
                        };
                    }
                    else
                    {
                        ByteXYZ regioncoords = PGSectors.GetSectorPos(regionname);
                        if (regioncoords != ByteXYZ.Invalid)
                        {
                            string _regionname = PGSectors.GetSectorName(regioncoords);
                            coords = new int[]
                            {
                                (regioncoords.X << starclass) + blkcoords.X,
                                (regioncoords.Y << starclass) + blkcoords.Y,
                                (regioncoords.Z << starclass) + blkcoords.Z
                            };
                        }
                    }

                    if (coords != null)
                    {
                        long id = GetProcGenId(coords, starclass, index);

                        if (SystemsById.ContainsKey(id))
                        {
                            return(new PGStarMatch[] { SystemsById[id] });
                        }
                    }
                }
            }

            return(new PGStarMatch[0]);
        }
示例#2
0
        public static long GetProcGenId(ByteXYZ regionCoords, UShortXYZ relCoords, int starclass, int starseq)
        {
            int blocksize = 40960 >> starclass;

            int[] coords = new int[]
            {
                (int)(regionCoords.X * 40960 + relCoords.X) / blocksize,
                (int)(regionCoords.Y * 40960 + relCoords.Y) / blocksize,
                (int)(regionCoords.Z * 40960 + relCoords.Z) / blocksize
            };
            return(GetProcGenId(coords, starclass, starseq));
        }
示例#3
0
 private static uint Interleave3(ByteXYZ val)
 {
     unchecked
     {
         ulong x = (((ulong)val.X & 0x7F)) | (((ulong)val.Y & 0x7F) << 7) | (((ulong)val.Z & 0x7F) << 14);
         x = (x | (x << 32)) & 0x001F00000000FFFFUL;
         x = (x | (x << 16)) & 0x001F0000FF0000FFUL;
         x = (x | (x << 8)) & 0x100F00F00F00F00FUL;
         x = (x | (x << 4)) & 0x10C30C30C30C30C3UL;
         x = (x | (x << 2)) & 0x1249249249249249UL;
         return((uint)((x | (x >> 20) | (x >> 40)) & 0x1FFFFF));
     }
 }
示例#4
0
        public static string GetPgSuffix(ByteXYZ blockcoords, int starclass)
        {
            int  blocknr = blockcoords.X + ((int)blockcoords.Y << 7) + ((int)blockcoords.Z << 14);
            char v1      = (char)((blocknr % 26) + 'A');

            blocknr /= 26;
            char v2 = (char)((blocknr % 26) + 'A');

            blocknr /= 26;
            char v3 = (char)((blocknr % 26) + 'A');

            blocknr /= 26;
            char   sc = (char)('h' - starclass);
            string v4 = blocknr == 0 ? "" : $"{blocknr}-";

            return($"{v1}{v2}-{v3} {sc}{v4}");
        }
        public ByteXYZ GetBlockCoords(PGStarMatch m)
        {
            int starclass = m.StarClass;

            int[] v0 = GetBaseBlockCoords(starclass);
            int[] v  = m.BlockCoords;
            int[] bc = new int[] { v[0] - v0[0], v[1] - v0[1], v[2] - v0[2] };
            if (bc[0] < 0 || bc[0] >= 128 || bc[1] < 0 || bc[1] >= 128 || bc[2] < 0 || bc[2] >= 128)
            {
                return(ByteXYZ.Invalid);
            }
            else
            {
                ByteXYZ blockcoords = new ByteXYZ {
                    X = (sbyte)bc[0], Y = (sbyte)bc[1], Z = (sbyte)bc[2]
                };
                string suffix = PGStarMatch.GetPgSuffix(blockcoords, m.StarClass, m.StarSeq);

                return(blockcoords);
            }
        }
示例#6
0
        // Region coords to sector name - based on https://bitbucket.org/Esvandiary/edts/src/master/pgnames.py
        public static string GetSectorName(ByteXYZ pos)
        {
            if (CachedSectorsByCoords.ContainsKey(pos))
            {
                return(CachedSectorsByCoords[pos]);
            }
            else
            {
                int    offset = (pos.Z << 14) + (pos.Y << 7) + pos.X;
                string sectorname;

                if (IsC1Sector(offset))
                {
                    sectorname = GetC1Name(offset);
                }
                else
                {
                    sectorname = GetC2Name(offset);
                }

                CachedSectorsByCoords[pos] = sectorname;
                return(sectorname);
            }
        }
示例#7
0
        public static long GetProcGenId(string sysname, Vector3 starpos, out HandAuthoredSector sector)
        {
            int     index     = 0;
            int     starclass = 0;
            ByteXYZ blkcoords = new ByteXYZ();

            int[] coords = null;
            sector = null;

            string regionname = GetProcGenRegionNameFromSystemName(sysname, out index, out starclass, ref blkcoords);

            if (regionname == null)
            {
                if (SystemsByName.ContainsKey(sysname))
                {
                    List <PGStarMatch> matches = SystemsByName[sysname].Select(s => SystemsById[s]).ToList();
                    foreach (PGStarMatch sm in matches)
                    {
                        Vector3 smcoords = sm.Coords;
                        Vector3 diff     = new Vector3 {
                            X = smcoords.X - starpos.X, Y = smcoords.Y - starpos.Y, Z = smcoords.Z - starpos.Z
                        };
                        double sqdist = diff.X * diff.X + diff.Y * diff.Y + diff.Z * diff.Z;
                        if (sqdist < 0.015625)
                        {
                            sector = sm.HASector;
                            return(sm.Id);
                        }
                    }
                }
                else
                {
                    return(0);
                }
            }
            else
            {
                sector = HandAuthoredSectors.Sectors.FindSector(regionname).FirstOrDefault();
                if (sector != null)
                {
                    int[] basecoords = sector.GetBaseBlockCoords(starclass);
                    coords = new int[]
                    {
                        basecoords[0] + blkcoords.X,
                        basecoords[1] + blkcoords.Y,
                        basecoords[2] + blkcoords.Z
                    };
                }
                else
                {
                    ByteXYZ regioncoords = PGSectors.GetSectorPos(regionname);
                    if (regioncoords != ByteXYZ.Invalid)
                    {
                        coords = new int[]
                        {
                            (regioncoords.X << starclass) + blkcoords.X,
                            (regioncoords.Y << starclass) + blkcoords.Y,
                            (regioncoords.Z << starclass) + blkcoords.Z
                        };
                    }
                }
            }

            if (coords != null)
            {
                long id = GetProcGenId(coords, starclass, index);

                if (id < 0)
                {
                    Console.WriteLine($"Error: {sysname} => {id} ([{coords[0]},{coords[1]},{coords[2]}]:{starclass}:{index})");
                }

                return(id);
            }
            else
            {
                return(0);
            }
        }
示例#8
0
        public static PGStarMatch GetStarMatch(string sysname, Vector3 starpos, uint edsmid = 0, uint eddbid = 0)
        {
            int     index     = 0;
            int     starclass = 0;
            ByteXYZ blkcoords = new ByteXYZ();

            int[] coords = null;
            HandAuthoredSector sector = null;

            if (SystemsByName.ContainsKey(sysname))
            {
                List <PGStarMatch> matches = SystemsByName[sysname].Select(i => SystemsById[i]).ToList();

                if (matches.Count == 1)
                {
                    return(matches[0]);
                }

                foreach (PGStarMatch sm in matches)
                {
                    Vector3 smcoords = sm.Coords;
                    Vector3 diff     = new Vector3 {
                        X = smcoords.X - starpos.X, Y = smcoords.Y - starpos.Y, Z = smcoords.Z - starpos.Z
                    };
                    double sqdist = diff.X * diff.X + diff.Y * diff.Y + diff.Z * diff.Z;
                    if (sqdist < 0.015625)
                    {
                        sector = sm.HASector;
                        return(sm);
                    }
                }
            }

            string regionname = GetProcGenRegionNameFromSystemName(sysname, out index, out starclass, ref blkcoords);

            int blocksize = 40960 >> starclass;

            double vx = starpos.X + 49985;
            double vy = starpos.Y + 40985;
            double vz = starpos.Z + 24105;

            if (vx < 0 || vx >= 163840 || vy < 0 || vy > 163840 || vz < 0 || vz > 163840)
            {
                return(PGStarMatch.Invalid);
            }

            int x = (int)(vx * 32 + 0.5);
            int y = (int)(vy * 32 + 0.5);
            int z = (int)(vz * 32 + 0.5);

            int cx = x / blocksize;
            int cy = y / blocksize;
            int cz = z / blocksize;

            if (regionname != null && starpos != null && !Double.IsNaN(starpos.X) && !Double.IsNaN(starpos.Y) && !Double.IsNaN(starpos.Z))
            {
                sector = HandAuthoredSectors.Sectors.FindSector(regionname)?.First();
                if (sector != null)
                {
                    int[] basecoords = sector.GetBaseBlockCoords(starclass);
                    coords = new int[]
                    {
                        basecoords[0] + blkcoords.X,
                        basecoords[1] + blkcoords.Y,
                        basecoords[2] + blkcoords.Z
                    };
                }
                else
                {
                    int     bx           = (x % 40960) / blocksize;
                    int     by           = (y % 40960) / blocksize;
                    int     bz           = (z % 40960) / blocksize;
                    ByteXYZ regioncoords = new ByteXYZ {
                        X = (sbyte)(x / 40960), Y = (sbyte)(y / 40960), Z = (sbyte)(z / 40960)
                    };
                    string  pgregion   = PGSectors.GetSectorName(regioncoords);
                    ByteXYZ nregcoords = pgregion == regionname ? regioncoords : PGSectors.GetSectorPos(regionname);

                    if (bx == blkcoords.X && by == blkcoords.Y && bz == blkcoords.Z && nregcoords == regioncoords)
                    {
                        coords = new int[] { cx, cy, cz };
                    }
                    else
                    {
                        ByteXYZ relcoords = new ByteXYZ {
                            X = (sbyte)bx, Y = (sbyte)by, Z = (sbyte)bz
                        };

                        if (nregcoords == ByteXYZ.Invalid)
                        {
                            Console.WriteLine($"System {sysname}: Unknown sector {regionname} @ {regioncoords} - coordname={pgregion} {GetPgSuffix(relcoords, starclass, index)}");
                        }
                        else
                        {
                            Vector3 namecoords = new Vector3
                            {
                                X = (nregcoords.X * 40960 + blkcoords.X * blocksize) / 32.0 - 49985,
                                Y = (nregcoords.Y * 40960 + blkcoords.Y * blocksize) / 32.0 - 40985,
                                Z = (nregcoords.Z * 40960 + blkcoords.Z * blocksize) / 32.0 - 24105
                            };
                            Console.WriteLine($"System {sysname}: Bad coordinates for sector {regionname} @ {regioncoords} - coordname={pgregion} {GetPgSuffix(relcoords, starclass, index)} | namecoords={namecoords}");
                        }
                        return(PGStarMatch.Invalid);
                    }
                }

                int ix = coords[0];
                int iy = coords[1];
                int iz = coords[2];

                long id = GetProcGenId(coords, starclass, index);

                if (SystemsById.ContainsKey(id))
                {
                    PGStarMatch sm = SystemsById[id];

                    if (cx != ix || cy != iy || cz != iz)
                    {
                        Vector3 error = new Vector3 {
                            X = coords[0] * blocksize / 32.0 - 49985, Y = coords[1] * blocksize / 32.0 - 40985, Z = coords[2] * blocksize / 32.0 - 24105
                        };
                        Console.WriteLine($"Warning: System {sysname} Coord mismatch - starpos={starpos} | match={sm.Coords} | namepos={error}");
                    }

                    if ((eddbid == 0 && edsmid != 0 && sm._EdsmId == 0) || (sm._EdsmId == edsmid && eddbid != 0 && sm._EddbId == 0))
                    {
                        if (eddbid == 0 && edsmid != 0 && sm._EdsmId == 0)
                        {
                            sm._EdsmId = edsmid;
                        }

                        if (sm._EdsmId == edsmid && eddbid != 0 && sm._EddbId == 0)
                        {
                            sm._EddbId = eddbid;
                        }

                        SystemsById[id] = sm;
                    }

                    return(sm);
                }
                else
                {
                    PGStarMatch sm = new PGStarMatch
                    {
                        _RegionCoordsX           = (sbyte)(x / 40960),
                        _RegionCoordsY           = (sbyte)(y / 40960),
                        _RegionCoordsZ           = (sbyte)(z / 40960),
                        _RelCoordsX              = (ushort)(x % 40960),
                        _RelCoordsY              = (ushort)(y % 40960),
                        _RelCoordsZ              = (ushort)(z % 40960),
                        _StarSeq                 = (ushort)index,
                        _StarClass               = (byte)starclass,
                        _HandAuthoredSectorIndex = (ushort)(HandAuthoredSectors.Sectors.IndexOf(sector) + 1),
                        _EdsmId = edsmid,
                        _EddbId = eddbid
                    };

                    if (cx != ix || cy != iy || cz != iz)
                    {
                        Vector3 error = new Vector3 {
                            X = coords[0] * blocksize / 32.0 - 49985, Y = coords[1] * blocksize / 32.0 - 40985, Z = coords[2] * blocksize / 32.0 - 24105
                        };
                        int[] bc = sm.BlockCoords;
                        Console.WriteLine($"Warning: System {sysname} Coord mismatch - pgname={sm.HPGName} | starpos={starpos} | namepos={error} | nc=({coords[0]}, {coords[1]}, {coords[2]}) | pc=({bc[0]}, {bc[1]}, {bc[2]})");
                    }

                    SystemsById[id] = sm;
                    return(sm);
                }
            }
            else
            {
                return(PGStarMatch.Invalid);
            }
        }
示例#9
0
        public static string GetProcGenRegionNameFromSystemName(string s, out int index, out int starclass, ref ByteXYZ blkcoords)
        {
            int i      = s.Length - 1;
            int blknum = 0;

            index     = 0;
            starclass = 0;

            string _s = s.ToLowerInvariant();

            if (i < 9)
            {
                return(null);                                          // a bc-d e0
            }
            if (_s[i] < '0' || _s[i] > '9')
            {
                return(null);                                          // cepheus dark region a sector xy-z a1-[0]
            }
            while (i > 8 && _s[i] >= '0' && _s[i] <= '9')
            {
                i--;
            }
            if (i < _s.Length - 6)
            {
                return(null);
            }
            index = Int32.Parse(_s.Substring(i + 1));
            if (_s[i] == '-')                                          // cepheus dark region a sector xy-z a1[-]0
            {
                i--;
                int vend = i;
                while (i > 8 && _s[i] >= '0' && _s[i] <= '9')
                {
                    i--;                                               // cepheus dark region a sector xy-z a[1]-0
                }
                if (i < vend - 4)
                {
                    return(null);
                }
                blknum = Int32.Parse(_s.Substring(i + 1, vend - i));
            }
            if (_s[i] < 'a' || _s[i] > 'h')
            {
                return(null);                                          // cepheus dark region a sector xy-z [a]1-0
            }
            starclass = 'h' - _s[i];
            i--;
            if (_s[i] != ' ')
            {
                return(null);                                          // cepheus dark region a sector xy-z[ ]a1-0
            }
            i--;
            if (_s[i] < 'a' || _s[i] > 'z')
            {
                return(null);                                          // cepheus dark region a sector xy-[z] a1-0
            }
            blknum = blknum * 26 + _s[i] - 'a';
            i--;
            if (_s[i] != '-')
            {
                return(null);                                          // cepheus dark region a sector xy[-]z a1-0
            }
            i--;
            if (_s[i] < 'a' || _s[i] > 'z')
            {
                return(null);                                          // cepheus dark region a sector x[y]-z a1-0
            }
            blknum = blknum * 26 + _s[i] - 'a';
            i--;
            if (_s[i] < 'a' || _s[i] > 'z')
            {
                return(null);                                          // cepheus dark region a sector [x]y-z a1-0
            }
            blknum = blknum * 26 + _s[i] - 'a';
            i--;
            if (_s[i] != ' ')
            {
                return(null);                                          // cepheus dark region a sector[ ]xy-z a1-0
            }
            i--;
            blkcoords = new ByteXYZ(
                (sbyte)(blknum & 127),
                (sbyte)((blknum >> 7) & 127),
                (sbyte)((blknum >> 14) & 127)
                );
            return(s.Substring(0, i + 1));                                 // [cepheus dark region a sector] xy-z a1-0
        }
示例#10
0
        public static string GetPgSuffix(ByteXYZ blockcoords, int starclass, int starseq)
        {
            string pgbsuffix = GetPgSuffix(blockcoords, starclass);

            return($"{pgbsuffix}{starseq}");
        }
示例#11
0
 public static string GetC2SectorName(ByteXYZ pos)
 {
     return(GetC2Name((pos.Z << 14) + (pos.Y << 7) + pos.X));
 }