public void Load_Chem()
        {
            R_Chemistry1.Load(@"C:\Report\R_Chemistry.rpt");
            crystalReportViewer4.ReportSource     = R_Chemistry1;
            crystalReportViewer4.SelectionFormula = "{t_result_main1.resultid} = '" + this.Tag.ToString() + "'";

            ClassSql a = new ClassSql();
            TextBox  txt_ForNo = new TextBox(); TextBox txt_RevNo = new TextBox();

            a.PutDataTOTextBox("SELECT * FROM tbl_formno WHERE cn = '4'", txt_ForNo, "Form");
            a.PutDataTOTextBox("SELECT * FROM tbl_formno WHERE cn = '4'", txt_RevNo, "Revision");
            TextObject FormNo = (TextObject)R_Chemistry1.ReportDefinition.ReportObjects["txt_formNo"];
            TextObject RevNo  = (TextObject)R_Chemistry1.ReportDefinition.ReportObjects["txt_RevNo"];

            FormNo.Text = txt_ForNo.Text;
            RevNo.Text  = txt_RevNo.Text;


            //R_HemaLab011.Refresh();
            crystalReportViewer4.RefreshReport();
            RemoveTab(crystalReportViewer4);
            wizard1.SelectedTab = tabPage4;
        }
        public void Load_Chem()
        {
            IniFile ini = new IniFile(ClassSql.MMS_Path);

            R_Chemistry1.SetDatabaseLogon(ini.IniReadValue("CONNECTIONSTRING", "Uid"), ini.IniReadValue("CONNECTIONSTRING", "Pwd"), ini.IniReadValue("CONNECTIONSTRING", "Server"), ini.IniReadValue("CONNECTIONSTRING", "Database"));

            R_Chemistry1.Load(@"C:\Report\R_Chemistry.rpt");
            Viewer_04.ReportSource     = R_Chemistry1;
            Viewer_04.SelectionFormula = "{t_result_main1.resultid} = '" + this.Tag.ToString() + "'";

            //ClassSql a = new ClassSql();
            //TextBox txt_ForNo = new TextBox(); TextBox txt_RevNo = new TextBox();
            //a.PutDataTOTextBox("SELECT * FROM tbl_formno WHERE cn = '4'", txt_ForNo, "Form");
            //a.PutDataTOTextBox("SELECT * FROM tbl_formno WHERE cn = '4'", txt_RevNo, "Revision");

            TextObject FormNo = (TextObject)R_Chemistry1.ReportDefinition.ReportObjects["txt_formNo"];
            TextObject RevNo  = (TextObject)R_Chemistry1.ReportDefinition.ReportObjects["txt_RevNo"];

            FormNo.Text = ini.IniReadValue("FORM", "Lab_Chemistry");
            RevNo.Text  = ini.IniReadValue("REVISION", "Lab_Chemistry");


            TextObject a = (TextObject)R_Chemistry1.ReportDefinition.ReportObjects["Text9"];
            TextObject b = (TextObject)R_Chemistry1.ReportDefinition.ReportObjects["Text44"];
            TextObject c = (TextObject)R_Chemistry1.ReportDefinition.ReportObjects["Text45"];
            TextObject d = (TextObject)R_Chemistry1.ReportDefinition.ReportObjects["Text51"];
            TextObject e = (TextObject)R_Chemistry1.ReportDefinition.ReportObjects["Text61"];
            TextObject f = (TextObject)R_Chemistry1.ReportDefinition.ReportObjects["Text62"];
            TextObject g = (TextObject)R_Chemistry1.ReportDefinition.ReportObjects["Text63"];
            TextObject h = (TextObject)R_Chemistry1.ReportDefinition.ReportObjects["Text64"];
            TextObject i = (TextObject)R_Chemistry1.ReportDefinition.ReportObjects["Text65"];
            TextObject j = (TextObject)R_Chemistry1.ReportDefinition.ReportObjects["Text75"];
            TextObject k = (TextObject)R_Chemistry1.ReportDefinition.ReportObjects["Text76"];
            TextObject l = (TextObject)R_Chemistry1.ReportDefinition.ReportObjects["Text77"];
            TextObject m = (TextObject)R_Chemistry1.ReportDefinition.ReportObjects["Text78"];
            TextObject n = (TextObject)R_Chemistry1.ReportDefinition.ReportObjects["Text79"];
            TextObject o = (TextObject)R_Chemistry1.ReportDefinition.ReportObjects["Text80"];
            TextObject p = (TextObject)R_Chemistry1.ReportDefinition.ReportObjects["Text81"];
            TextObject q = (TextObject)R_Chemistry1.ReportDefinition.ReportObjects["Text82"];
            TextObject r = (TextObject)R_Chemistry1.ReportDefinition.ReportObjects["Text83"];


            a.Text = ini.IniReadValue("NormalValue", "fbs") + " mmol/L";
            b.Text = ini.IniReadValue("NormalValue", "bun") + " mmol/L";
            c.Text = ini.IniReadValue("NormalValue", "creatine") + " mmol/L";
            d.Text = ini.IniReadValue("NormalValue", "choles") + " mmol/L";
            e.Text = ini.IniReadValue("NormalValue", "trigly") + " mmol/L";
            f.Text = ini.IniReadValue("NormalValue", "uric") + " mmol/L";
            g.Text = ini.IniReadValue("NormalValue", "sgot") + " IU/L";
            h.Text = ini.IniReadValue("NormalValue", "sgpt") + " IU/L";
            i.Text = ini.IniReadValue("NormalValue", "alk") + " IU/L";
            j.Text = ini.IniReadValue("NormalValue", "fbs_con") + " mg/dL";
            k.Text = ini.IniReadValue("NormalValue", "bun_con") + " mg/dL";
            l.Text = ini.IniReadValue("NormalValue", "creatine_Con") + " mg/dL";
            m.Text = ini.IniReadValue("NormalValue", "Cholesterol_Con") + " mg/dL";
            n.Text = ini.IniReadValue("NormalValue", "Trig_Con") + " mg/dL";
            o.Text = ini.IniReadValue("NormalValue", "Uric_Con") + " mg/dL";
            p.Text = ini.IniReadValue("NormalValue", "sgpt_con");
            q.Text = ini.IniReadValue("NormalValue", "sgot_con");
            r.Text = ini.IniReadValue("NormalValue", "alk_con");



            //R_HemaLab011.Refresh();
            Viewer_04.RefreshReport();
            RemoveTab(Viewer_04);
            wizard1.SelectedTab = tabPage4;
        }