示例#1
0
        private static IEnumerable <Type> GetBrainSimUIExtensionTypes()
        {
            var ret = new List <Type>();

            foreach (FileInfo assemblyFile in MyConfiguration.ListModules())
            {
                try
                {
                    Assembly assembly = Assembly.LoadFrom(assemblyFile.FullName);
                    string   xml;
                    if (MyResources.TryGetTextFromAssembly(assembly, MyModuleConfig.MODULE_CONFIG_FILE, out xml))
                    {
                        continue;
                    }

                    MyLog.INFO.WriteLine("UI module loaded: " + assemblyFile.Name);
                    ret.AddRange(assembly.GetTypes().Where(IsUIExtension));
                }
                catch (Exception ex)
                {
                    MyLog.DEBUG.WriteLine("Error when looking for UI modules: " + ex.Message);
                }
            }

            return(ret);
        }
示例#2
0
        private IEnumerable <string> FindTestAssemblies()
        {
            List <string> fileList = FindBrainTestAssemblies().ToList();

            fileList.AddRange(MyConfiguration.ListModules().Select(fileInfo => fileInfo.FullName));

            return(fileList);
        }
示例#3
0
        public void Compile(string script, MyValidator validator)
        {
            if (m_node.Language != this.Language)
            {
                throw new ArgumentException("Language is not supported (" + this.Language + " only): " + m_node.Language);
            }

            m_methods.Clear();

            CSharpCodeProvider codeProvider = new CSharpCodeProvider();
            CompilerParameters parameters   = new CompilerParameters()
            {
                GenerateInMemory   = false,
                GenerateExecutable = false,
            };

            parameters.ReferencedAssemblies.Add("GoodAI.Platform.Core.dll");
            parameters.ReferencedAssemblies.Add("System.Core.dll"); //for LINQ support

            // add all loaded dll modules to be accessible also from the C# node script
            foreach (FileInfo assemblyFile in MyConfiguration.ListModules())
            {
                parameters.ReferencedAssemblies.Add(assemblyFile.FullName);
            }

            parameters.ReferencedAssemblies.Add(Assembly.GetExecutingAssembly().Location);

            Assembly[]             loadedAssemblies = AppDomain.CurrentDomain.GetAssemblies();
            IEnumerable <Assembly> openTKAssemblies = loadedAssemblies.Where(x => x.ManifestModule.Name == "OpenTK.dll").ToList();

            if (openTKAssemblies.Any())
            {
                parameters.ReferencedAssemblies.Add(openTKAssemblies.First().Location);
            }

            CompilerResults results          = codeProvider.CompileAssemblyFromSource(parameters, script);
            Assembly        compiledAssembly = null;

            if (results.Errors.HasErrors)
            {
                string message = "";

                foreach (CompilerError error in results.Errors)
                {
                    message += "\nLine " + error.Line + ": " + error.ErrorText;
                }
                validator.AddError(m_node, "Errors in compiled script:" + message);
            }
            else
            {
                compiledAssembly = results.CompiledAssembly;
            }

            if (compiledAssembly != null)
            {
                try
                {
                    Type enclosingType = compiledAssembly.GetType("Runtime.Script");
                    Type methodEnum    = typeof(TMethodEnum);

                    foreach (string methodName in methodEnum.GetEnumNames())
                    {
                        MethodInfo method = enclosingType.GetMethod(methodName);

                        if (method != null)
                        {
                            m_methods[methodName] = method;
                        }
                        else
                        {
                            validator.AddError(m_node, methodName + "() method not found in compiled script");
                        }
                    }
                }
                catch (Exception e)
                {
                    validator.AddError(m_node, "Script analysis failed: " + e.GetType().Name + ": " + e.Message);
                }
            }
        }