public void ShouldDiscardAllButMostRecentStaleInputParametersAfterStalenessInterval()
        {
            var c  = new Controller();
            var mc = new FakeMulticlampCommander();

            var mcd = new MultiClampDevice(mc, c, UNUSED_BACKGROUND_DICTIONARY);

            mcd.BindStream(new DAQInputStream(UNUSED_NAME));

            var data1     = new MultiClampInterop.MulticlampData();
            var expected2 = new MultiClampInterop.MulticlampData();
            var expected  = new MultiClampInterop.MulticlampData();

            var marker = DateTimeOffset.Now.ToUniversalTime();

            mc.FireParametersChanged(marker.Subtract(TimeSpan.FromSeconds(MultiClampDevice.ParameterStalenessInterval.TotalSeconds * 3)), data1);
            mc.FireParametersChanged(marker.Subtract(TimeSpan.FromSeconds(MultiClampDevice.ParameterStalenessInterval.TotalSeconds * 2)), expected);
            mc.FireParametersChanged(marker, expected2);

            Assert.That(((MultiClampParametersChangedArgs)mcd.DeviceParametersForInput(DateTimeOffset.Now)).Data,
                        Is.EqualTo(expected2));


            var oldTime = DateTimeOffset.Now.Subtract(MultiClampDevice.ParameterStalenessInterval);

            Assert.That(((MultiClampParametersChangedArgs)mcd.DeviceParametersForInput(oldTime)).Data,
                        Is.EqualTo(expected));

            var veryOldTime = marker.Subtract(TimeSpan.FromSeconds(MultiClampDevice.ParameterStalenessInterval.TotalSeconds * 3));

            Assert.Throws <MultiClampDeviceException>(() => mcd.DeviceParametersForInput(veryOldTime));
        }
        public void ShouldAllowBackgroundValueChangeAfterConstruction()
        {
            const string units = "V";

            var c  = new Controller();
            var mc = new FakeMulticlampCommander();

            var bg            = new Measurement(2, -3, units);
            var operatingMode = MultiClampInterop.OperatingMode.VClamp;
            var background    = new Dictionary <MultiClampInterop.OperatingMode, IMeasurement>()
            {
                { operatingMode, bg }
            };

            var mcd = new MultiClampDevice(mc, c, background);

            mcd.BindStream(new DAQOutputStream(UNUSED_NAME));

            var data = new MultiClampInterop.MulticlampData()
            {
                OperatingMode = operatingMode,
                ExternalCommandSensitivity      = 2.5,
                ExternalCommandSensitivityUnits = MultiClampInterop.ExternalCommandSensitivityUnits.V_V
            };

            mc.FireParametersChanged(DateTimeOffset.Now, data);

            var newBackground = new Measurement(10, -3, units);

            mcd.Background = newBackground;

            var expected = new Measurement(newBackground.QuantityInBaseUnit / (decimal)data.ExternalCommandSensitivity, newBackground.Exponent, "V");

            Assert.That(mcd.OutputBackground, Is.EqualTo(expected));
        }
        public void ShouldThrowExceptionConvertingInputGivenEmptyParametersQueue()
        {
            var c  = new Controller();
            var mc = new FakeMulticlampCommander();

            var mcd = new MultiClampDevice(mc, c, UNUSED_BACKGROUND_DICTIONARY);

            mcd.BindStream(new DAQInputStream(UNUSED_NAME));


            Assert.Throws <MultiClampDeviceException>(() => mcd.ConvertInput(new Measurement(0, "V"), DateTimeOffset.Now));
        }
        public void ShouldThrowExceptionConvertingInputGivenNoParametersForTime()
        {
            var c  = new Controller();
            var mc = new FakeMulticlampCommander();

            var mcd = new MultiClampDevice(mc, c, UNUSED_BACKGROUND_DICTIONARY);

            mcd.BindStream(new DAQInputStream(UNUSED_NAME));

            mc.FireParametersChanged(DateTimeOffset.Now.Subtract(TimeSpan.FromHours(1)), new MultiClampInterop.MulticlampData());


            Assert.Throws <MultiClampDeviceException>(() => mcd.ConvertInput(new Measurement(0, "V"), DateTimeOffset.Now));
        }
        public void ShouldProvideCurrentOutputParameters()
        {
            var c  = new Controller();
            var mc = new FakeMulticlampCommander();

            var mcd = new MultiClampDevice(mc, c, UNUSED_BACKGROUND_DICTIONARY);

            mcd.BindStream(new DAQOutputStream(UNUSED_NAME));

            var expected = new MultiClampInterop.MulticlampData();

            mc.FireParametersChanged(DateTimeOffset.Now.Subtract(TimeSpan.FromHours(1)), expected);

            Assert.That(mcd.CurrentDeviceOutputParameters.Data,
                        Is.EqualTo(expected));
        }
        public void ShouldUseBackgroundForMode()
        {
            const string VClampUnits = "V";
            const string IClampUnits = "A";

            Measurement VClampBackground = new Measurement(2, -3, VClampUnits);
            Measurement IClampBackground = new Measurement(-10, -3, IClampUnits);

            var c  = new Controller();
            var mc = new FakeMulticlampCommander();

            var bg = new Dictionary <MultiClampInterop.OperatingMode, IMeasurement>()
            {
                { MultiClampInterop.OperatingMode.VClamp, VClampBackground },
                { MultiClampInterop.OperatingMode.IClamp, IClampBackground },
            };

            var mcd = new MultiClampDevice(mc, c, bg);

            mcd.BindStream(new DAQOutputStream(UNUSED_NAME));

            var data = new MultiClampInterop.MulticlampData()
            {
                OperatingMode = MultiClampInterop.OperatingMode.VClamp,
                ExternalCommandSensitivity      = 2.5,
                ExternalCommandSensitivityUnits = MultiClampInterop.ExternalCommandSensitivityUnits.V_V
            };

            mc.FireParametersChanged(DateTimeOffset.Now, data);

            Assert.That(mcd.OutputBackground, Is.EqualTo(MultiClampDevice.ConvertOutput(VClampBackground, mcd.CurrentDeviceOutputParameters.Data)));

            data = new MultiClampInterop.MulticlampData()
            {
                OperatingMode = MultiClampInterop.OperatingMode.IClamp,
                ExternalCommandSensitivity      = 1.5,
                ExternalCommandSensitivityUnits = MultiClampInterop.ExternalCommandSensitivityUnits.A_V
            };

            mc.FireParametersChanged(DateTimeOffset.Now, data);

            Assert.That(mcd.OutputBackground, Is.EqualTo(MultiClampDevice.ConvertOutput(IClampBackground, mcd.CurrentDeviceOutputParameters.Data)));
        }
        public void ShouldTakeMostRecentParametersForInput()
        {
            var c  = new Controller();
            var mc = new FakeMulticlampCommander();

            var mcd = new MultiClampDevice(mc, c, UNUSED_BACKGROUND_DICTIONARY);

            mcd.BindStream(new DAQInputStream(UNUSED_NAME));

            var data1    = new MultiClampInterop.MulticlampData();
            var expected = new MultiClampInterop.MulticlampData();
            var data3    = new MultiClampInterop.MulticlampData();

            mc.FireParametersChanged(DateTimeOffset.Now.Subtract(TimeSpan.FromHours(1)), data1);
            mc.FireParametersChanged(DateTimeOffset.Now.Subtract(TimeSpan.FromMilliseconds(1)), expected);
            mc.FireParametersChanged(DateTimeOffset.Now.Add(TimeSpan.FromHours(1)), data3);

            Assert.That(((MultiClampParametersChangedArgs)mcd.DeviceParametersForInput(DateTimeOffset.Now)).Data,
                        Is.EqualTo(expected));
        }
        public void ShouldNotApplyBackgroundToRunningStreams()
        {
            const string units = "V";
            const MultiClampInterop.OperatingMode vclampMode = MultiClampInterop.OperatingMode.VClamp;
            const MultiClampInterop.OperatingMode iclampMode = MultiClampInterop.OperatingMode.IClamp;


            var c  = new Controller();
            var mc = new FakeMulticlampCommander();

            var vclampBackground = new Measurement(2, -3, units);

            var background = new Dictionary <MultiClampInterop.OperatingMode, IMeasurement>()
            {
                { vclampMode, vclampBackground }
            };

            var dataVClamp = new MultiClampInterop.MulticlampData()
            {
                OperatingMode = vclampMode,
                ExternalCommandSensitivity      = 2.5,
                ExternalCommandSensitivityUnits = MultiClampInterop.ExternalCommandSensitivityUnits.V_V
            };


            var daq = new DynamicMock(typeof(IDAQController));
            var s   = new DAQOutputStream("test", daq.MockInstance as IDAQController);


            var mcd = new MultiClampDevice(mc, c, background);

            mcd.BindStream(s);

            daq.ExpectAndReturn("get_Running", true);
            daq.ExpectNoCall("ApplyStreamBackground");

            mc.FireParametersChanged(DateTimeOffset.Now, dataVClamp);

            daq.Verify();
        }
        private void BackgroundTest(MultiClampInterop.OperatingMode operatingMode,
                                    string units,
                                    MultiClampInterop.ExternalCommandSensitivityUnits extSensUnits)
        {
            var c  = new Controller();
            var mc = new FakeMulticlampCommander();

            var bg = new Measurement(2, -3, units);

            var background = new Dictionary <MultiClampInterop.OperatingMode, IMeasurement>()
            {
                { operatingMode, bg }
            };
            var mcd = new MultiClampDevice(mc, c, background);

            mcd.BindStream(new DAQOutputStream(UNUSED_NAME));

            var data = new MultiClampInterop.MulticlampData()
            {
                OperatingMode = operatingMode,
                ExternalCommandSensitivity      = 2.5,
                ExternalCommandSensitivityUnits = extSensUnits
            };

            mc.FireParametersChanged(DateTimeOffset.Now, data);


            var expected = operatingMode == MultiClampInterop.OperatingMode.I0 ?
                           new Measurement(0, "V") :
                           new Measurement(bg.QuantityInBaseUnit / (decimal)data.ExternalCommandSensitivity, bg.Exponent, "V");

            mc.FireParametersChanged(DateTimeOffset.Now.Subtract(TimeSpan.FromHours(1)), data);

            var actual = mcd.OutputBackground;

            Assert.That(actual, Is.EqualTo(expected));
        }
Пример #10
0
        public void ShouldThrowExceptionConvertingOutputGivenNoParametersForTime()
        {
            var c = new Controller();
            var mc = new FakeMulticlampCommander();

            var mcd = new MultiClampDevice(mc, c, UNUSED_BACKGROUND_DICTIONARY);
            mcd.BindStream(new DAQOutputStream(UNUSED_NAME));

            mc.FireParametersChanged(DateTimeOffset.Now.Add(TimeSpan.FromHours(1)), new MultiClampInterop.MulticlampData());

            Assert.Throws<MultiClampDeviceException>(() => mcd.ConvertOutput(new Measurement(0, "V"), DateTimeOffset.Now));
        }
Пример #11
0
        public void ShouldThrowExceptionConvertingInputGivenEmptyParametersQueue()
        {
            var c = new Controller();
            var mc = new FakeMulticlampCommander();

            var mcd = new MultiClampDevice(mc, c, UNUSED_BACKGROUND_DICTIONARY);
            mcd.BindStream(new DAQInputStream(UNUSED_NAME));

            Assert.Throws<MultiClampDeviceException>(() => mcd.ConvertInput(new Measurement(0, "V"), DateTimeOffset.Now));
        }
Пример #12
0
        public void ShouldTakeMostRecentParametersForOutput()
        {
            var data1 = new MultiClampInterop.MulticlampData();
            var expected = new MultiClampInterop.MulticlampData();
            var data3 = new MultiClampInterop.MulticlampData();

            var c = new Controller();
            var mc = new FakeMulticlampCommander();

            var mcd = new MultiClampDevice(mc, c, UNUSED_BACKGROUND_DICTIONARY);
            mcd.BindStream(new DAQOutputStream(UNUSED_NAME));

            mc.FireParametersChanged(DateTimeOffset.Now.Subtract(TimeSpan.FromHours(1)), data1);
            mc.FireParametersChanged(DateTimeOffset.Now.Subtract(TimeSpan.FromMilliseconds(1)), expected);
            mc.FireParametersChanged(DateTimeOffset.Now.Add(TimeSpan.FromHours(1)), data3);

            Assert.That(((MultiClampParametersChangedArgs)mcd.DeviceParametersForOutput(DateTimeOffset.Now)).Data,
                Is.EqualTo(expected));
        }
Пример #13
0
        public void ShouldProvideCurrentOutputParametersAfterMultipleParameterChangedEvents()
        {
            var c = new Controller();
            var mc = new FakeMulticlampCommander();

            var mcd = new MultiClampDevice(mc, c, UNUSED_BACKGROUND_DICTIONARY);
            mcd.BindStream(new DAQOutputStream(UNUSED_NAME));

            var data1 = new MultiClampInterop.MulticlampData();
            var expected = new MultiClampInterop.MulticlampData();

            mc.FireParametersChanged(DateTimeOffset.Now.Subtract(TimeSpan.FromHours(1)), data1);
            mc.FireParametersChanged(DateTimeOffset.Now.Subtract(TimeSpan.FromHours(1)), expected);

            Assert.That(mcd.CurrentDeviceOutputParameters.Data,
                Is.EqualTo(expected));
        }
Пример #14
0
        public void ShouldNotApplyBackgroundToRunningStreams()
        {
            const string units = "V";
            const MultiClampInterop.OperatingMode vclampMode = MultiClampInterop.OperatingMode.VClamp;
            const MultiClampInterop.OperatingMode iclampMode = MultiClampInterop.OperatingMode.IClamp;

            var c = new Controller();
            var mc = new FakeMulticlampCommander();

            var vclampBackground = new Measurement(2, -3, units);

            var background = new Dictionary<MultiClampInterop.OperatingMode, IMeasurement>()
                                 {
                                     { vclampMode, vclampBackground }
                                 };

            var dataVClamp = new MultiClampInterop.MulticlampData()
            {
                OperatingMode = vclampMode,
                ExternalCommandSensitivity = 2.5,
                ExternalCommandSensitivityUnits = MultiClampInterop.ExternalCommandSensitivityUnits.V_V
            };

            var daq = new DynamicMock(typeof(IDAQController));
            var s = new DAQOutputStream("test", daq.MockInstance as IDAQController);

            var mcd = new MultiClampDevice(mc, c, background);
            mcd.BindStream(s);

            daq.ExpectAndReturn("get_Running", true);
            daq.ExpectNoCall("ApplyStreamBackground");

            mc.FireParametersChanged(DateTimeOffset.Now, dataVClamp);

            daq.Verify();
        }
Пример #15
0
        public void ShouldDiscardAllButMostRecentStaleOutputParametersAfterStalenessInterval()
        {
            var c = new Controller();
            var mc = new FakeMulticlampCommander();

            var mcd = new MultiClampDevice(mc, c, UNUSED_BACKGROUND_DICTIONARY);
            mcd.BindStream(new DAQOutputStream(UNUSED_NAME));

            var data1 = new MultiClampInterop.MulticlampData();
            var expected2 = new MultiClampInterop.MulticlampData();
            var expected = new MultiClampInterop.MulticlampData();

            var marker = DateTimeOffset.Now.ToUniversalTime();

            mc.FireParametersChanged(marker.Subtract(TimeSpan.FromSeconds(MultiClampDevice.ParameterStalenessInterval.TotalSeconds * 3)), data1);
            mc.FireParametersChanged(marker.Subtract(TimeSpan.FromSeconds(MultiClampDevice.ParameterStalenessInterval.TotalSeconds * 2)), expected);
            mc.FireParametersChanged(marker, expected2);

            Assert.That(((MultiClampParametersChangedArgs)mcd.DeviceParametersForOutput(DateTimeOffset.Now)).Data,
                Is.EqualTo(expected2));

            var oldTime = DateTimeOffset.Now.Subtract(MultiClampDevice.ParameterStalenessInterval);
            Assert.That(((MultiClampParametersChangedArgs)mcd.DeviceParametersForOutput(oldTime)).Data,
                Is.EqualTo(expected));

            var veryOldTime = marker.Subtract(TimeSpan.FromSeconds(MultiClampDevice.ParameterStalenessInterval.TotalSeconds * 3));
            Assert.Throws<MultiClampDeviceException>(() => mcd.DeviceParametersForOutput(veryOldTime));
        }
Пример #16
0
        public void ShouldAllowBackgroundValueChangeAfterConstruction()
        {
            const string units = "V";

            var c = new Controller();
            var mc = new FakeMulticlampCommander();

            var bg = new Measurement(2, -3, units);
            var operatingMode = MultiClampInterop.OperatingMode.VClamp;
            var background = new Dictionary<MultiClampInterop.OperatingMode, IMeasurement>() { { operatingMode, bg } };

            var mcd = new MultiClampDevice(mc, c, background);
            mcd.BindStream(new DAQOutputStream(UNUSED_NAME));

            var data = new MultiClampInterop.MulticlampData()
            {
                OperatingMode = operatingMode,
                ExternalCommandSensitivity = 2.5,
                ExternalCommandSensitivityUnits = MultiClampInterop.ExternalCommandSensitivityUnits.V_V
            };

            mc.FireParametersChanged(DateTimeOffset.Now, data);

            var newBackground = new Measurement(10, -3, units);

            mcd.Background = newBackground;

            var expected = new Measurement(newBackground.QuantityInBaseUnit / (decimal)data.ExternalCommandSensitivity, newBackground.Exponent, "V");

            Assert.That(mcd.OutputBackground, Is.EqualTo(expected));
        }
        public void ShouldThrowExceptionConvertingInputGivenNoParametersForTime()
        {
            var c = new Controller();
            var mc = new FakeMulticlampCommander();

            var mcd = new MultiClampDevice(mc, c, UNUSED_BACKGROUND_DICTIONARY);
            mcd.BindStream(new DAQInputStream(UNUSED_NAME));

            mc.FireParametersChanged(DateTimeOffset.Now.Subtract(TimeSpan.FromHours(1)),
                new MultiClampInterop.MulticlampData()
                    {
                        HardwareType = MultiClampInterop.HardwareType.MCTG_HW_TYPE_MC700B,
                        ScaledOutputSignal700B = MultiClampInterop.SignalIdentifier700B.AXMCD_OUT_PRI_VC_GLDR_I_MEMB,
                    });

            Assert.Throws<MultiClampDeviceException>(() => mcd.ConvertInput(new Measurement(0, "V"), DateTimeOffset.Now));
        }
        public void ShouldRetrieveCurrentDeviceOutputParametersUsingClock()
        {
            var c = new Controller();
            var mc = new FakeMulticlampCommander();

            var time = DateTimeOffset.MinValue.Add(MultiClampDevice.ParameterStalenessInterval);

            var clock = Substitute.For<IClock>();
            clock.Now.Returns(time);
            var mcd = new MultiClampDevice(mc, c, UNUSED_BACKGROUND_DICTIONARY) { Clock = clock };

            mcd.BindStream(new DAQOutputStream(UNUSED_NAME));

            var data = new MultiClampInterop.MulticlampData();
            var expected = new MultiClampInterop.MulticlampData();

            mc.FireParametersChanged(time, data);

            Assert.That(mcd.CurrentDeviceOutputParameters.Data, Is.EqualTo(expected));
        }
Пример #19
0
        public void ShouldUseBackgroundForMode()
        {
            const string VClampUnits = "V";
            const string IClampUnits = "A";

            Measurement VClampBackground = new Measurement(2, -3, VClampUnits);
            Measurement IClampBackground = new Measurement(-10, -3, IClampUnits);

            var c = new Controller();
            var mc = new FakeMulticlampCommander();

            var bg = new Dictionary<MultiClampInterop.OperatingMode, IMeasurement>()
                         {
                             {MultiClampInterop.OperatingMode.VClamp, VClampBackground},
                             {MultiClampInterop.OperatingMode.IClamp, IClampBackground},
                         };

            var mcd = new MultiClampDevice(mc, c, bg);
            mcd.BindStream(new DAQOutputStream(UNUSED_NAME));

            var data = new MultiClampInterop.MulticlampData()
            {
                OperatingMode = MultiClampInterop.OperatingMode.VClamp,
                ExternalCommandSensitivity = 2.5,
                ExternalCommandSensitivityUnits = MultiClampInterop.ExternalCommandSensitivityUnits.V_V
            };

            mc.FireParametersChanged(DateTimeOffset.Now, data);

            Assert.That(mcd.OutputBackground, Is.EqualTo(MultiClampDevice.ConvertOutput(VClampBackground, mcd.CurrentDeviceOutputParameters.Data)));

            data = new MultiClampInterop.MulticlampData()
            {
                OperatingMode = MultiClampInterop.OperatingMode.IClamp,
                ExternalCommandSensitivity = 1.5,
                ExternalCommandSensitivityUnits = MultiClampInterop.ExternalCommandSensitivityUnits.A_V
            };

            mc.FireParametersChanged(DateTimeOffset.Now, data);

            Assert.That(mcd.OutputBackground, Is.EqualTo(MultiClampDevice.ConvertOutput(IClampBackground, mcd.CurrentDeviceOutputParameters.Data)));
        }
Пример #20
0
        private void BackgroundTest(MultiClampInterop.OperatingMode operatingMode,
            string units,
            MultiClampInterop.ExternalCommandSensitivityUnits extSensUnits)
        {
            var c = new Controller();
            var mc = new FakeMulticlampCommander();

            var bg = new Measurement(2, -3, units);

            var background = new Dictionary<MultiClampInterop.OperatingMode, IMeasurement>() { { operatingMode, bg } };
            var mcd = new MultiClampDevice(mc, c, background);
            mcd.BindStream(new DAQOutputStream(UNUSED_NAME));

            var data = new MultiClampInterop.MulticlampData()
                           {
                               OperatingMode = operatingMode,
                               ExternalCommandSensitivity = 2.5,
                               ExternalCommandSensitivityUnits = extSensUnits
                           };

            mc.FireParametersChanged(DateTimeOffset.Now, data);

            var expected = operatingMode == MultiClampInterop.OperatingMode.I0 ?
                new Measurement(0, "V") :
                new Measurement(bg.QuantityInBaseUnit / (decimal)data.ExternalCommandSensitivity, bg.Exponent, "V");

            mc.FireParametersChanged(DateTimeOffset.Now.Subtract(TimeSpan.FromHours(1)), data);

            var actual = mcd.OutputBackground;

            Assert.That(actual, Is.EqualTo(expected));
        }
        public void ShouldNotApplyBackgroundToRunningStreams()
        {
            const string units = "V";
            const MultiClampInterop.OperatingMode vclampMode = MultiClampInterop.OperatingMode.VClamp;

            var c = new Controller();
            var mc = new FakeMulticlampCommander();

            var vclampBackground = new Measurement(2, -3, units);

            var background = new Dictionary<MultiClampInterop.OperatingMode, IMeasurement>()
                                 {
                                     { vclampMode, vclampBackground }
                                 };

            var dataVClamp = new MultiClampInterop.MulticlampData()
            {
                OperatingMode = vclampMode,
                ExternalCommandSensitivity = 2.5,
                ExternalCommandSensitivityUnits = MultiClampInterop.ExternalCommandSensitivityUnits.V_V
            };

            var daq = Substitute.For<IDAQController>();
            var s = new DAQOutputStream("test", daq);

            var mcd = new MultiClampDevice(mc, c, background);
            mcd.BindStream(s);

            daq.IsRunning.Returns(true);

            mc.FireParametersChanged(DateTimeOffset.Now, dataVClamp);

            daq.DidNotReceiveWithAnyArgs().ApplyStreamBackground(s);
        }