Пример #1
0
        public bool Insert_PumpStationInfo(ref CPumpStationInfo pump)
        {
            MySqlDataReader reader;
            string strcmd = "INSERT INTO [PumpStationInfo] ([SystemID],[X_Coor],[Y_Coor],[PumpName],[PumpAddr],[PS_Category1]," +
                "[PS_Category2],[PS_Num],[Design_Storm],[Design_Sewer],[Min_Level],[Control_Level],[Warnning_Level],[DataSource]," +
                "[Record_Data],[ReportDept],[ReportDate]" +
                ")values('" +
                pump.SystemID + "','" + pump.X_Coor + "','" + pump.Y_Coor + "','" + pump.PumpName + "','" + pump.PumpAddr + "', " + pump.PS_Category1 +
                " , " + pump.PS_Category2 + " , " + pump.PS_Num + " ,'" + pump.Design_Storm + "','" + pump.Design_Sewer + "','" + pump.Min_Level + "','" +
                pump.Control_Level + "','" + pump.Warnning_Level + "', " + pump.DataSource + " ,#" + pump.Record_Date + "#,'" + pump.ReportDept + "',#" +
                pump.ReportDate + "#)";
            try
            {
                connect.Open();
                MySqlCommand cmd = new MySqlCommand();
                cmd.Connection = connect;
                cmd.CommandType = CommandType.Text;
                cmd.CommandText = strcmd;

                strcmd = "SELECT MAX([ID]) AS MAXID FROM [PumpStationInfo]";
                cmd.ExecuteNonQuery();
                cmd.CommandText = strcmd;
                reader = cmd.ExecuteReader();
                reader.Read();
                pump.ID = Convert.ToInt32(reader[0].ToString());
            }
            catch (System.Exception ex)
            {
                Console.WriteLine(ex.Message);
                return false;
            }
            finally
            {
                connect.Close();
            }
            return true;
        }
Пример #2
0
 private List<CPumpStationInfo> Select(string cmd)
 {
     List<CPumpStationInfo> listpump = new List<CPumpStationInfo>();
     MySqlCommand com;
     MySqlDataReader reader;
     try
     {
         connect.Open();
         com = new MySqlCommand(cmd, connect);
         reader = com.ExecuteReader();
         while (reader.Read())
         {
             CPumpStationInfo pump = new CPumpStationInfo();
             int i = 0;
             string tmp;
             pump.ID = Convert.ToInt32(reader[i++].ToString());
             pump.SystemID = reader[i++].ToString();
             tmp = reader[i++].ToString();
             if (tmp != null || tmp.Length > 0)
                 pump.X_Coor = Convert.ToDouble(tmp);
             tmp = reader[i++].ToString();
             if (tmp != null || tmp.Length > 0)
                 pump.Y_Coor = Convert.ToDouble(tmp);
             pump.PumpName = reader[i++].ToString();
             pump.PumpAddr = reader[i++].ToString();
             tmp = reader[i++].ToString();
             if (tmp != null || tmp.Length > 0)
                 pump.PS_Category1 = Convert.ToInt32(tmp);
             tmp = reader[i++].ToString();
             if (tmp != null || tmp.Length > 0)
                 pump.PS_Category2 = Convert.ToInt32(tmp);
             tmp = reader[i++].ToString();
             if (tmp != null || tmp.Length > 0)
                 pump.PS_Num = Convert.ToInt32(tmp);
             tmp = reader[i++].ToString();
             if (tmp != null || tmp.Length > 0)
                 pump.Design_Storm = Convert.ToDouble(tmp);
             tmp = reader[i++].ToString();
             if (tmp != null || tmp.Length > 0)
                 pump.Design_Sewer = Convert.ToDouble(tmp);
             tmp = reader[i++].ToString();
             if (tmp != null || tmp.Length > 0)
                 pump.Min_Level = Convert.ToDouble(tmp);
             tmp = reader[i++].ToString();
             if (tmp != null || tmp.Length > 0)
                 pump.Control_Level = Convert.ToDouble(tmp);
             tmp = reader[i++].ToString();
             if (tmp != null || tmp.Length > 0)
                 pump.Warnning_Level = Convert.ToDouble(tmp);
             tmp = reader[i++].ToString();
             if (tmp != null || tmp.Length > 0)
                 pump.DataSource = Convert.ToInt32(tmp);
             tmp = reader[i++].ToString();
             if (tmp != null || tmp.Length > 0)
                 pump.Record_Date = Convert.ToDateTime(tmp);
             pump.ReportDept = reader[i++].ToString();
             tmp = reader[i++].ToString();
             if (tmp != null || tmp.Length > 0)
                 pump.ReportDate = Convert.ToDateTime(tmp);
             listpump.Add(pump);
         }
     }
     catch (System.Exception ex)
     {
         Console.WriteLine(ex.Message);
         return null;
     }
     finally
     {
         connect.Close();
     }
     return listpump;
 }
Пример #3
0
 public bool Delete_PumpStationInfo(CPumpStationInfo pump)
 {
     List<string> listcmd = new List<string>();
     try
     {
         string cmd = "DELETE * FROM [PumpStationInfo] where ID = " + pump.ID;
         listcmd.Add(cmd);
         ExectueCmd(listcmd);
     }
     catch (System.Exception ex)
     {
         Console.WriteLine(ex.Message);
         return false;
     }
     return true;
 }