Пример #1
0
        public static int Main()
        {
            var CommandLine = SharedUtils.ParseCommandLine();

            LogUtils.InitLogging(CommandLine);

            ErrorCodes ReturnCode = ErrorCodes.Error_Success;

            try
            {
                HostPlatform.Initialize();

                Log.TraceVerbose("Running on {0} as a {1}-bit process.", HostPlatform.Current.GetType().Name, Environment.Is64BitProcess ? 64 : 32);

                XmlConfigLoader.Init();

                // Log if we're running from the launcher
                var ExecutingAssemblyLocation = CommandUtils.CombinePaths(Assembly.GetExecutingAssembly().Location);
                if (String.Compare(ExecutingAssemblyLocation, CommandUtils.CombinePaths(InternalUtils.ExecutingAssemblyLocation), true) != 0)
                {
                    Log.WriteLine(TraceEventType.Information, "Executed from AutomationToolLauncher ({0})", ExecutingAssemblyLocation);
                }
                Log.WriteLine(TraceEventType.Information, "CWD={0}", Environment.CurrentDirectory);

                // Hook up exit callbacks
                var Domain = AppDomain.CurrentDomain;
                Domain.ProcessExit  += Domain_ProcessExit;
                Domain.DomainUnload += Domain_ProcessExit;
                HostPlatform.Current.SetConsoleCtrlHandler(ProgramCtrlHandler);

                var Version = InternalUtils.ExecutableVersion;
                Log.WriteLine(TraceEventType.Verbose, "{0} ver. {1}", Version.ProductName, Version.ProductVersion);

                // Don't allow simultaneous execution of AT (in the same branch)
                InternalUtils.RunSingleInstance(MainProc, CommandLine);
            }
            catch (Exception Ex)
            {
                // Catch all exceptions and propagate the ErrorCode if we are given one.
                Log.WriteLine(TraceEventType.Error, "AutomationTool terminated with exception:");
                Log.WriteLine(TraceEventType.Error, LogUtils.FormatException(Ex));
                // set the exit code of the process
                if (Ex is AutomationException)
                {
                    ReturnCode = (Ex as AutomationException).ErrorCode;
                }
                else
                {
                    ReturnCode = ErrorCodes.Error_Unknown;
                }
            }
            finally
            {
                // In all cases, do necessary shut down stuff, but don't let any additional exceptions leak out while trying to shut down.

                // Make sure there's no directories on the stack.
                NoThrow(() => CommandUtils.ClearDirStack(), "Clear Dir Stack");

                // Try to kill process before app domain exits to leave the other KillAll call to extreme edge cases
                NoThrow(() => { if (ShouldKillProcesses && !Utils.IsRunningOnMono)
                                {
                                    ProcessManager.KillAll();
                                }
                        }, "Kill All Processes");

                Log.WriteLine(TraceEventType.Information, "AutomationTool exiting with ExitCode={0}", ReturnCode);

                // Can't use NoThrow here because the code logs exceptions. We're shutting down logging!
                LogUtils.ShutdownLogging();
            }

            // STOP: No code beyond the return statement should go beyond this point!
            // Nothing should happen after the finally block above is finished.
            return((int)ReturnCode);
        }
Пример #2
0
        public static int Main()
        {
            var CommandLine = SharedUtils.ParseCommandLine();

            LogUtils.InitLogging(CommandLine);

            ExitCode ReturnCode = ExitCode.Success;

            try
            {
                // ensure we can resolve any external assemblies as necessary.
                AssemblyUtils.InstallAssemblyResolver(Path.GetDirectoryName(Assembly.GetEntryAssembly().GetOriginalLocation()));
                HostPlatform.Initialize();

                Log.TraceVerbose("{2}: Running on {0} as a {1}-bit process.", HostPlatform.Current.GetType().Name, Environment.Is64BitProcess ? 64 : 32, DateTime.UtcNow.ToString("o"));

                // Log if we're running from the launcher
                var ExecutingAssemblyLocation = Assembly.GetExecutingAssembly().Location;
                if (string.Compare(ExecutingAssemblyLocation, Assembly.GetEntryAssembly().GetOriginalLocation(), StringComparison.OrdinalIgnoreCase) != 0)
                {
                    Log.TraceVerbose("Executed from AutomationToolLauncher ({0})", ExecutingAssemblyLocation);
                }
                Log.TraceVerbose("CWD={0}", Environment.CurrentDirectory);

                // Hook up exit callbacks
                var Domain = AppDomain.CurrentDomain;
                Domain.ProcessExit  += Domain_ProcessExit;
                Domain.DomainUnload += Domain_ProcessExit;
                HostPlatform.Current.SetConsoleCtrlHandler(CtrlHandlerDelegateInstance);

                var Version = AssemblyUtils.ExecutableVersion;
                Log.TraceVerbose("{0} ver. {1}", Version.ProductName, Version.ProductVersion);

                // Don't allow simultaneous execution of AT (in the same branch)
                ReturnCode = InternalUtils.RunSingleInstance(MainProc, CommandLine);
            }
            catch (AutomationException Ex)
            {
                Log.TraceError("AutomationTool terminated with exception: {0}", Ex);
                ReturnCode = Ex.ErrorCode;
            }
            catch (Exception Ex)
            {
                // Catch all exceptions and propagate the ErrorCode if we are given one.
                Log.TraceError("AutomationTool terminated with exception: {0}", Ex);
                ReturnCode = ExitCode.Error_Unknown;
            }
            finally
            {
                // In all cases, do necessary shut down stuff, but don't let any additional exceptions leak out while trying to shut down.

                // Make sure there's no directories on the stack.
                NoThrow(() => CommandUtils.ClearDirStack(), "Clear Dir Stack");

                // Try to kill process before app domain exits to leave the other KillAll call to extreme edge cases
                NoThrow(() => { if (ShouldKillProcesses && !Utils.IsRunningOnMono)
                                {
                                    ProcessManager.KillAll();
                                }
                        }, "Kill All Processes");

                Log.TraceInformation("AutomationTool exiting with ExitCode={0} ({1})", (int)ReturnCode, ReturnCode);

                // Can't use NoThrow here because the code logs exceptions. We're shutting down logging!
                LogUtils.ShutdownLogging();
            }

            // STOP: No code beyond the return statement should go beyond this point!
            // Nothing should happen after the finally block above is finished.
            return((int)ReturnCode);
        }
Пример #3
0
        public static int Main()
        {
            var CommandLine = SharedUtils.ParseCommandLine();

            HostPlatform.Initialize();

            LogUtils.InitLogging(CommandLine);
            try
            {
                Log.WriteLine(TraceEventType.Information, "Running on {0}", HostPlatform.Current.GetType().Name);

                XmlConfigLoader.Init();

                // Log if we're running from the launcher
                var ExecutingAssemblyLocation = CommandUtils.CombinePaths(Assembly.GetExecutingAssembly().Location);
                if (String.Compare(ExecutingAssemblyLocation, CommandUtils.CombinePaths(InternalUtils.ExecutingAssemblyLocation), true) != 0)
                {
                    Log.WriteLine(TraceEventType.Information, "Executed from AutomationToolLauncher ({0})", ExecutingAssemblyLocation);
                }
                Log.WriteLine(TraceEventType.Information, "CWD={0}", Environment.CurrentDirectory);

                // Hook up exit callbacks
                var Domain = AppDomain.CurrentDomain;
                Domain.ProcessExit  += Domain_ProcessExit;
                Domain.DomainUnload += Domain_ProcessExit;
                HostPlatform.Current.SetConsoleCtrlHandler(ProgramCtrlHandler);

                var Version = InternalUtils.ExecutableVersion;
                Log.WriteLine(TraceEventType.Verbose, "{0} ver. {1}", Version.ProductName, Version.ProductVersion);

                try
                {
                    // Don't allow simultaneous execution of AT (in the same branch)
                    ReturnCode = InternalUtils.RunSingleInstance(MainProc, CommandLine);
                }
                catch (Exception Ex)
                {
                    Log.WriteLine(TraceEventType.Error, "AutomationTool terminated with exception:");
                    Log.WriteLine(TraceEventType.Error, LogUtils.FormatException(Ex));
                    Log.WriteLine(TraceEventType.Error, Ex.Message);
                    if (ReturnCode == 0)
                    {
                        ReturnCode = (int)ErrorCodes.Error_Unknown;
                    }
                }

                // Make sure there's no directiories on the stack.
                CommandUtils.ClearDirStack();
                Environment.ExitCode = ReturnCode;

                // Try to kill process before app domain exits to leave the other KillAll call to extreme edge cases
                if (ShouldKillProcesses && !Utils.IsRunningOnMono)
                {
                    ProcessManager.KillAll();
                }

                Log.WriteLine(TraceEventType.Information, "AutomationTool exiting with ExitCode={0}", ReturnCode);
            }
            finally
            {
                // ensure that logging is always shut down cleanly, as this potentially copies the log to a final resting place.
                LogUtils.ShutdownLogging();
            }

            return(ReturnCode);
        }