Exemplo n.º 1
0
        public WebProxy init()
        {
            string     path          = Environment.CurrentDirectory + @"\proxy_N.ini";
            INIManager client_man    = new INIManager(path);
            string     login_proxy   = client_man.GetPrivateString("GN_PROXY", "login");  //получ ключ активации
            string     pass_proxy    = client_man.GetPrivateString("GN_PROXY", "pass");   //получ ключ активации
            string     address_proxy = client_man.GetPrivateString("GN_PROXY", "server"); //получ ключ активации
            string     port_proxy    = client_man.GetPrivateString("GN_PROXY", "port");   //получ ключ активации
            string     vkl           = client_man.GetPrivateString("GN_PROXY", "vkl");    //получ ключ активации
            bool       proxy_isp     = false;

            log.Add("login_proxy " + login_proxy);
            if (vkl == "true")
            {
                proxy_isp = true;
            }
            WebProxy myProxy = new WebProxy();

            if (proxy_isp)
            {
                log.Add("прокси используется ");
                myProxy.Address     = new Uri(@"http://" + address_proxy + ":" + port_proxy);
                myProxy.Credentials = new NetworkCredential(login_proxy, pass_proxy);
            }
            else
            {
                log.Add("прокси НЕ используется ");
                myProxy = null;
            }
            return(myProxy);
        }
Exemplo n.º 2
0
        public Proxy()
        {
            InitializeComponent();
            FileInfo fileInf = new FileInfo(path);

            if (fileInf.Exists)//если файл существет
            {
                INIManager client_man = new INIManager(path);
                px_l.Text     = client_man.GetPrivateString("GN_PROXY", "login");  //получ ключ активации
                px_p.Password = client_man.GetPrivateString("GN_PROXY", "pass");   //получ ключ активации
                px_s.Text     = client_man.GetPrivateString("GN_PROXY", "server"); //получ ключ активации
                px_port.Text  = client_man.GetPrivateString("GN_PROXY", "port");   //получ ключ активации
                string vkl = client_man.GetPrivateString("GN_PROXY", "vkl");       //получ ключ активации
                if (vkl == "true")
                {
                    px_vkl.IsChecked = true;
                }
                else
                {
                    px_vkl.IsChecked = false;
                }
            }
            else
            {
                fileInf.Create();
            }



            if (px_vkl.IsChecked == true)
            {
                G1.IsEnabled = true;
            }
            else
            {
                G1.IsEnabled = false;
            }
        }
Exemplo n.º 3
0
        public TAccessories(string path, string text, neqweqe _neqqqqq)
        {
            InitializeComponent();
            this.neqqqqq    = _neqqqqq;
            BD.path         = path; //укажем файл бд
            this.text_otvet = text;
            log.Add("Запуск окна");
            timer.Tick    += new EventHandler(timerTick);
            timer.Interval = new TimeSpan(0, 0, 0, 0, 500);
            log.Add("Запуск таймера");
            loadpage();//загрузка полож окна

            INIManager client_man = new INIManager(Environment.CurrentDirectory + @"\_ecadpro\ecadpro.ini");

            ismanager = client_man.GetPrivateString("giulianovars", "ismanager");//версия клиента
            if (ismanager == "1")
            {
                btnimp.Visibility = Visibility.Visible;
            }
            else
            {
                btnimp.Visibility = Visibility.Collapsed;
            }

            //отделка
            log.Add("Подключимся к бд");
            OleDbDataReader reader_otd = BD.conn("SELECT Id, Name FROM TOtdelka order by Name ASC");

            otdelka_array = new List <todelka>();
            otdelka_array.Add(new todelka()
            {
                ID = "", nameotd = ""
            });
            while (reader_otd.Read())
            {
                if (reader_otd["Name"].ToString() != "")
                {
                    otdelka_array.Add(new todelka()
                    {
                        ID      = reader_otd["Id"].ToString(),
                        nameotd = reader_otd["Name"].ToString(),
                    });
                }
            }
            log.Add("установим отделку");
            otdelka.ItemsSource = otdelka_array;
            //.ItemsSource = todelka;
            //ед изм
            OleDbDataReader reader_izmer = BD.conn("SELECT UnitsID, UnitsName FROM TUnits order by UnitsName ASC");

            while (reader_izmer.Read())
            {
                if (reader_izmer["UnitsName"].ToString() != "")
                {
                    izmer.Add(new todelka()
                    {
                        ID      = reader_izmer["UnitsID"].ToString(),
                        nameotd = reader_izmer["UnitsName"].ToString(),
                    });
                }
            }
            log.Add("установим ед изм");
            edizmer.ItemsSource = izmer;


            log.Add("загрузим аксссуары");
            //аксессуары
            OleDbDataReader reader_GRACC = BD.conn("SELECT TPrice1.GRAFIKA, TPrice1.Articul, TUnits.UnitsID, TPrice1.TKOEFGROUP_ID, TUnits.UnitsName, TPrice1.MName, TPrice1.MatID,  TPrice1.PriceID,  TPrice1.Price, TMAT.MATNAME,  TPrice1.Visibl FROM (TPrice1  LEFT OUTER JOIN  TMAT ON TPrice1.MatID = TMAT.MATID) LEFT OUTER JOIN  TUnits ON TUnits.UnitsID=TPrice1.UnitsID  ");//WHERE TPrice1.GRAFIKA=0

            //LEFT OUTER JOIN  TUnits ON TUnits.UnitsID=TPrice1.UnitsID
            while (reader_GRACC.Read())
            {
                float baseprice = 0;
                if (reader_GRACC["Price"].ToString() != "")
                {
                    baseprice = Convert.ToSingle(reader_GRACC["Price"].ToString());
                }

                bool vived = true;
                if (reader_GRACC["Visibl"].ToString() == "1")
                {
                    vived = false;
                }


                int sort = 0;
                if (reader_GRACC["Articul"].ToString() == "***" || reader_GRACC["Articul"].ToString() == "15R***" || reader_GRACC["Articul"].ToString() == "SAD***")
                {
                }
                else
                {
                    sort = sort_forg1;
                }

                array_spis_tex.Add(new texnika()
                {
                    type             = "a",
                    ID               = reader_GRACC["PriceID"].ToString(),
                    TName            = reader_GRACC["MName"].ToString(),
                    Group            = reader_GRACC["MatID"].ToString(),
                    baseprice        = baseprice,
                    priceredak       = baseprice,
                    UnitsId          = reader_GRACC["UnitsName"].ToString(),
                    GroupName        = reader_GRACC["MATNAME"].ToString(),
                    UnitsName        = reader_GRACC["UnitsID"].ToString(),
                    Article          = reader_GRACC["Articul"].ToString(),
                    Prim             = "",
                    kolvo            = 1,
                    vived            = vived,
                    OTD              = "",
                    sort             = sort,
                    GROUP_dlyaspicif = reader_GRACC["TKOEFGROUP_ID"].ToString(),
                    GRAFIKA          = reader_GRACC["GRAFIKA"].ToString(),
                });

                sort_forg1++;
            }
            log.Add("Загрузим технику");
            //техника
            OleDbDataReader reader = BD.conn("SELECT TTxPrice1.Article, TTxPrice1.TName, TTxPrice1.TKOEFGROUP_ID, TTxPrice1.TPriceID, TTxPrice1.TexID, TTxPrice1.Price, TTexnics.TexType  FROM TTxPrice1  LEFT OUTER JOIN  TTexnics ON  TTxPrice1.TexID = TTexnics.TexID  ");

            while (reader.Read())
            {
                try
                {
                    float baseprice = 0;
                    if (reader["Price"].ToString() != "")
                    {
                        baseprice = Convert.ToSingle(reader["Price"].ToString());
                    }

                    int sort = 0;
                    if (reader["Article"].ToString() == "*")
                    {
                    }
                    else
                    {
                        sort = sort_forg1;
                    }


                    array_spis_tex.Add(new texnika()
                    {
                        type             = "t",
                        ID               = reader["TPriceID"].ToString(),
                        TName            = reader["TName"].ToString(),
                        Article          = reader["Article"].ToString(),
                        UnitsId          = "шт",
                        baseprice        = baseprice,
                        priceredak       = baseprice,
                        UnitsName        = "3",
                        GroupName        = reader["TexType"].ToString(),
                        Group            = reader["TexID"].ToString(),
                        Prim             = "",
                        kolvo            = 1,
                        OTD              = "",
                        sort             = sort,
                        GROUP_dlyaspicif = reader["TKOEFGROUP_ID"].ToString(),
                        GRAFIKA          = "0"
                    });
                }
                catch
                {
                    MessageBox.Show("err");
                }
                sort_forg1++;
            }



            MenuItem root = new MenuItem()
            {
                Title = "Все", type = "at*"
            };
            MenuItem childItem1 = new MenuItem()
            {
                Title = "Аксессуары", type = "a*"
            };

            log.Add("Загрузим матид");
            OleDbDataReader readertreeeacc = BD.conn("select T.MATID,MATNAME from TMAT T, TPrice1 T1 where T1.MATID = T.MATID  group by T.MATID,T.MATNAME ORDER BY T.MATNAME ASC");

            while (readertreeeacc.Read())
            {
                childItem1.Items.Add(new MenuItem()
                {
                    Title = readertreeeacc["MATNAME"].ToString(),
                    ID    = readertreeeacc["MATID"].ToString(),
                    type  = "a",
                });
            }


            root.Items.Add(childItem1);
            childItem1 = new MenuItem()
            {
                Title = "Техника", type = "t*"
            };
            log.Add("загрузим ттехникс");
            OleDbDataReader reader_texCB = BD.conn("select T.TexID,TexType from TTexnics T, TTxPrice1 T1 where T1.TexID=T.TexID  group by T.TEXID,T.TexType ORDER BY T.TexType ASC ");

            while (reader_texCB.Read())
            {
                childItem1.Items.Add(new MenuItem()
                {
                    Title = reader_texCB["TexType"].ToString(),
                    ID    = reader_texCB["TexID"].ToString(),
                    type  = "t",
                });
            }
            root.Items.Add(childItem1);

            tv1.Items.Add(root);

            log.Add("парсим строкуs");
            pars(text);
        }
Exemplo n.º 4
0
        public dial_for_acctex(texnika item)
        {
            InitializeComponent();


            otvet = item;

            //   MessageBox.Show(otvet.OTD);

            viewSource1         = new CollectionViewSource();
            viewSource1.Source  = TAccessories.otdelka_array;
            viewSource1.Filter += viewSource_Filter1;
            viewSource1.SortDescriptions.Add(new SortDescription("nameotd", ListSortDirection.Ascending));

            combo1.ItemsSource = viewSource1.View;



            //  combo1.ItemsSource = TAccessories.otdelka_array;
            combo2.ItemsSource = TAccessories.izmer;

            timer.Tick    += new EventHandler(timerTick);
            timer.Interval = new TimeSpan(0, 0, 0, 0, 500);



            rsktblo1_Copy.Text = otvet.Article;
            rsktb1.Text        = otvet.nom_pp.ToString();
            rsktb2.Text        = otvet.TName;
            rsktb3.Text        = otvet.kolvo.ToString();


            INIManager client_man = new INIManager(Environment.CurrentDirectory + @"\ecadpro.ini");
            string     admin      = client_man.GetPrivateString("giulianovars", "3dsadmin");//версия клиента

            //  MessageBox.Show("путь к ини" + sdsd + @"\ecadpro.ini");
            lb_TKOEFGROUP_ID.Visibility = Visibility.Hidden;
            if (admin == "1")
            {
                lb_TKOEFGROUP_ID.Visibility = Visibility.Visible;
                lb_TKOEFGROUP_ID.Text       = otvet.GROUP_dlyaspicif.ToString();
            }


            rsktb4.Text = otvet.Prim;

            rsktb3_Copy.Text  = otvet.baseprice.ToString();
            rsktb3_Copy1.Text = otvet.priceredak.ToString();

            combo1.SelectedIndex = (TAccessories.otdelka_array.FindIndex(x => x.ID.Equals(otvet.OTD)));
            combo2.SelectedIndex = (TAccessories.izmer.FindIndex(x => x.ID.Equals(otvet.UnitsName)));



            if (otvet.Article == "***" || otvet.Article == "*" || otvet.Article == "15R***" || otvet.Article == "SAD***")
            {//если
            }
            else
            {
                rsktb2.IsReadOnly      = true;
                rsktb2.Foreground      = Brushes.Gray;
                rsktb3_Copy.IsReadOnly = true;
                rsktb3_Copy.Foreground = Brushes.Gray;
                combo2.IsEnabled       = false;
            }
        }