Exemplo n.º 1
0
        private bool SaveFpDataToDB(byte[] FpData)
        {
            List <string> sql = new List <string>();

            byte[] buff       = new byte[1680];
            byte[] FpDataConv = new byte[1680];
            byte[] header     = { 0x45, 0x4e, 0x52, 0x4f, 0x4c, 0x4c, 0x46, 0x50, 0x01, 0x28 };
            Array.Copy(header, 0, FpDataConv, 0, header.Length); //Add Fixed Header
            Array.Copy(FpData, 0, FpDataConv, 80, FpData.Length);
            ObjFpReader.ConvEnrollData(FpDataConv, ref buff, 1680);

            //Update RS_Emp、VRS_EmpFingerInfo Table
            string EmpNo          = txtEmpNo.Text;
            string EnrollNumber   = txtFingerNo.Text;
            string BackupNumber   = fpDataList.Count.ToString();
            int    EmpFingerCount = fpDataList.Count + 1;

            try
            {
                sql.Add("UPDATE RS_Emp SET EmpFingerCount=" + EmpFingerCount.ToString() + " WHERE EmpNo='" + EmpNo + "'");
                sql.Add(Pub.GetSQL(DBCode.DB_000300, new string[] { "204", SystemInfo.MacTypeID.ToString(),
                                                                    EnrollNumber, fpDataList.Count.ToString(), "NULL" }));
                if (SystemInfo.db.ExecSQL(sql) == 0)
                {
                    SystemInfo.db.UpdateByteData(Pub.GetSQL(DBCode.DB_000300, new string[] { "202", SystemInfo.MacTypeID.ToString(),
                                                                                             EnrollNumber, BackupNumber }), "FingerData", buff);
                }
                return(true);
            }
            catch (Exception)
            {
                return(false);
            }
        }
Exemplo n.º 2
0
        private bool GetDbFingerData(string EmpNo, string FingerNo)
        {
            fpDataList.Clear();
            string    sql = "SELECT * FROM VRS_EmpFingerInfo WHERE EmpNo='" + EmpNo + "' AND FingerBkNo BETWEEN 0 AND 9 ORDER BY FingerBkNo";
            DataTable dt  = new DataTable();

            try
            {
                dt = SystemInfo.db.GetDataTable(sql);
                for (int i = 0; i < dt.Rows.Count; i++)
                {
                    byte[] buff     = (byte[])dt.Rows[i]["FingerData"];
                    byte[] buffConv = new byte[1680];
                    byte[] fpdata   = new byte[1600];
                    ObjFpReader.ConvEnrollData(buff, ref buffConv, 1680);
                    Array.Copy(buffConv, 80, fpdata, 0, 1600);
                    fpDataList.Add(fpdata);
                }

                return(true);
            }
            catch (Exception)
            {
                return(false);
            }
        }