/// <summary> /// AddAndReturnID /// </summary> /// <param name="pobjObjectVO"></param> /// <author>Trada</author> /// <date>Thursday, July 28 2005</date> public int AddAndReturnID(object pobjObjectVO) { const string METHOD_NAME = THIS + ".AddAndReturnID()"; OleDbConnection oconPCS = null; OleDbCommand ocmdPCS = null; try { IV_AdjustmentVO objObject = (IV_AdjustmentVO)pobjObjectVO; string strSql = String.Empty; Utils utils = new Utils(); oconPCS = new OleDbConnection(Utils.Instance.OleDbConnectionString); ocmdPCS = new OleDbCommand("", oconPCS); strSql = "INSERT INTO " + IV_AdjustmentTable.TABLE_NAME + "(" + IV_AdjustmentTable.MASTERLOCATIONID_FLD + "," + IV_AdjustmentTable.LOCATIONID_FLD + "," + IV_AdjustmentTable.BINID_FLD + "," + IV_AdjustmentTable.POSTDATE_FLD + "," + IV_AdjustmentTable.COMMENT_FLD + "," + IV_AdjustmentTable.CCNID_FLD + "," + IV_AdjustmentTable.TRANSNO_FLD + "," + IV_AdjustmentTable.PRODUCTID_FLD + "," + IV_AdjustmentTable.STOCKUMID_FLD + "," + IV_AdjustmentTable.SERIAL_FLD + "," + IV_AdjustmentTable.ADJUSTQUANTITY_FLD + "," + IV_AdjustmentTable.AVAILABLEQTY_FLD + "," + "UsedByCosting," + IV_AdjustmentTable.LOT_FLD + ")" + "VALUES(?,?,?,?,?,?,?,?,?,?,?,?,?,?)"; ocmdPCS.Parameters.Add(new OleDbParameter(IV_AdjustmentTable.MASTERLOCATIONID_FLD, OleDbType.Integer)); ocmdPCS.Parameters[IV_AdjustmentTable.MASTERLOCATIONID_FLD].Value = objObject.MasterLocationID; ocmdPCS.Parameters.Add(new OleDbParameter(IV_AdjustmentTable.LOCATIONID_FLD, OleDbType.Integer)); ocmdPCS.Parameters[IV_AdjustmentTable.LOCATIONID_FLD].Value = objObject.LocationID; ocmdPCS.Parameters.Add(new OleDbParameter(IV_AdjustmentTable.BINID_FLD, OleDbType.Integer)); if (objObject.BinID > 0) { ocmdPCS.Parameters[IV_AdjustmentTable.BINID_FLD].Value = objObject.BinID; } else { ocmdPCS.Parameters[IV_AdjustmentTable.BINID_FLD].Value = DBNull.Value; } ocmdPCS.Parameters.Add(new OleDbParameter(IV_AdjustmentTable.POSTDATE_FLD, OleDbType.Date)); ocmdPCS.Parameters[IV_AdjustmentTable.POSTDATE_FLD].Value = objObject.PostDate; ocmdPCS.Parameters.Add(new OleDbParameter(IV_AdjustmentTable.COMMENT_FLD, OleDbType.VarWChar)); ocmdPCS.Parameters[IV_AdjustmentTable.COMMENT_FLD].Value = objObject.Comment; ocmdPCS.Parameters.Add(new OleDbParameter(IV_AdjustmentTable.CCNID_FLD, OleDbType.Integer)); ocmdPCS.Parameters[IV_AdjustmentTable.CCNID_FLD].Value = objObject.CCNID; ocmdPCS.Parameters.Add(new OleDbParameter(IV_AdjustmentTable.TRANSNO_FLD, OleDbType.VarWChar)); ocmdPCS.Parameters[IV_AdjustmentTable.TRANSNO_FLD].Value = objObject.TransNo; ocmdPCS.Parameters.Add(new OleDbParameter(IV_AdjustmentTable.PRODUCTID_FLD, OleDbType.Integer)); ocmdPCS.Parameters[IV_AdjustmentTable.PRODUCTID_FLD].Value = objObject.ProductID; ocmdPCS.Parameters.Add(new OleDbParameter(IV_AdjustmentTable.STOCKUMID_FLD, OleDbType.Integer)); ocmdPCS.Parameters[IV_AdjustmentTable.STOCKUMID_FLD].Value = objObject.StockUMID; ocmdPCS.Parameters.Add(new OleDbParameter(IV_AdjustmentTable.SERIAL_FLD, OleDbType.VarWChar)); ocmdPCS.Parameters[IV_AdjustmentTable.SERIAL_FLD].Value = objObject.Serial; ocmdPCS.Parameters.Add(new OleDbParameter(IV_AdjustmentTable.ADJUSTQUANTITY_FLD, OleDbType.Decimal)); ocmdPCS.Parameters[IV_AdjustmentTable.ADJUSTQUANTITY_FLD].Value = objObject.AdjustQuantity; ocmdPCS.Parameters.Add(new OleDbParameter(IV_AdjustmentTable.AVAILABLEQTY_FLD, OleDbType.Decimal)); ocmdPCS.Parameters[IV_AdjustmentTable.AVAILABLEQTY_FLD].Value = objObject.AvailableQuantity; ocmdPCS.Parameters.Add(new OleDbParameter("UsedByCosting", OleDbType.Boolean)); ocmdPCS.Parameters["UsedByCosting"].Value = objObject.UsedByCosting; ocmdPCS.Parameters.Add(new OleDbParameter(IV_AdjustmentTable.LOT_FLD, OleDbType.VarWChar)); ocmdPCS.Parameters[IV_AdjustmentTable.LOT_FLD].Value = objObject.Lot; strSql += " ; SELECT @@IDENTITY AS NEWID"; ocmdPCS.CommandText = strSql; ocmdPCS.Connection.Open(); //ocmdPCS.ExecuteNonQuery(); object objReturn = ocmdPCS.ExecuteScalar(); if (objReturn != null) { return(int.Parse(objReturn.ToString())); } else { return(0); } } catch (OleDbException ex) { if (ex.Errors[1].NativeError == ErrorCode.SQLDUPLICATE_KEYCODE) { throw new PCSDBException(ErrorCode.DUPLICATE_KEY, METHOD_NAME, ex); } else { throw new PCSDBException(ErrorCode.ERROR_DB, METHOD_NAME, ex); } } catch (InvalidOperationException ex) { throw new PCSDBException(ErrorCode.ERROR_DB, METHOD_NAME, ex); } catch (Exception ex) { throw new PCSDBException(ErrorCode.OTHER_ERROR, METHOD_NAME, ex); } finally { if (oconPCS != null) { if (oconPCS.State != ConnectionState.Closed) { oconPCS.Close(); } } } }
/// <summary> /// This method uses to add data to IV_Adjustment /// </summary> /// <Inputs> /// IV_AdjustmentVO /// </Inputs> /// <Returns> /// void /// </Returns> /// <History> /// Thursday, June 23, 2005 /// </History> public object GetObjectVOByAdjustmentID(int pintID) { const string METHOD_NAME = THIS + ".GetObjectVO()"; DataSet dstPCS = new DataSet(); OleDbDataReader odrPCS = null; OleDbConnection oconPCS = null; OleDbCommand ocmdPCS = null; try { string strSql = String.Empty; strSql = "SELECT " + IV_AdjustmentTable.BINID_FLD + "," + IV_AdjustmentTable.MASTERLOCATIONID_FLD + "," + IV_AdjustmentTable.LOCATIONID_FLD + "," + IV_AdjustmentTable.ADJUSTMENTID_FLD + "," + IV_AdjustmentTable.POSTDATE_FLD + "," + IV_AdjustmentTable.COMMENT_FLD + "," + IV_AdjustmentTable.CCNID_FLD + "," + IV_AdjustmentTable.TRANSNO_FLD + "," + IV_AdjustmentTable.PRODUCTID_FLD + "," + IV_AdjustmentTable.STOCKUMID_FLD + "," + IV_AdjustmentTable.SERIAL_FLD + "," + IV_AdjustmentTable.ADJUSTQUANTITY_FLD + "," + IV_AdjustmentTable.LOT_FLD + " FROM " + IV_AdjustmentTable.TABLE_NAME + " WHERE " + IV_AdjustmentTable.ADJUSTMENTID_FLD + "=" + pintID; Utils utils = new Utils(); oconPCS = new OleDbConnection(Utils.Instance.OleDbConnectionString); ocmdPCS = new OleDbCommand(strSql, oconPCS); ocmdPCS.Connection.Open(); odrPCS = ocmdPCS.ExecuteReader(); IV_AdjustmentVO objObject = new IV_AdjustmentVO(); while (odrPCS.Read()) { objObject.BinID = int.Parse(odrPCS[IV_AdjustmentTable.BINID_FLD].ToString().Trim()); objObject.MasterLocationID = int.Parse(odrPCS[IV_AdjustmentTable.MASTERLOCATIONID_FLD].ToString().Trim()); objObject.LocationID = int.Parse(odrPCS[IV_AdjustmentTable.LOCATIONID_FLD].ToString().Trim()); objObject.AdjustmentID = int.Parse(odrPCS[IV_AdjustmentTable.ADJUSTMENTID_FLD].ToString().Trim()); objObject.PostDate = DateTime.Parse(odrPCS[IV_AdjustmentTable.POSTDATE_FLD].ToString().Trim()); objObject.Comment = odrPCS[IV_AdjustmentTable.COMMENT_FLD].ToString().Trim(); objObject.CCNID = int.Parse(odrPCS[IV_AdjustmentTable.CCNID_FLD].ToString().Trim()); objObject.TransNo = odrPCS[IV_AdjustmentTable.TRANSNO_FLD].ToString().Trim(); objObject.ProductID = int.Parse(odrPCS[IV_AdjustmentTable.PRODUCTID_FLD].ToString().Trim()); objObject.StockUMID = int.Parse(odrPCS[IV_AdjustmentTable.STOCKUMID_FLD].ToString().Trim()); objObject.Serial = odrPCS[IV_AdjustmentTable.SERIAL_FLD].ToString().Trim(); objObject.AdjustQuantity = Decimal.Parse(odrPCS[IV_AdjustmentTable.ADJUSTQUANTITY_FLD].ToString().Trim()); objObject.Lot = odrPCS[IV_AdjustmentTable.LOT_FLD].ToString().Trim(); } return(objObject); } catch (OleDbException ex) { throw new PCSDBException(ErrorCode.ERROR_DB, METHOD_NAME, ex); } catch (Exception ex) { throw new PCSDBException(ErrorCode.OTHER_ERROR, METHOD_NAME, ex); } finally { if (oconPCS != null) { if (oconPCS.State != ConnectionState.Closed) { oconPCS.Close(); } } } }
/// <summary> /// This method uses to add data to IV_Adjustment /// </summary> /// <Inputs> /// IV_AdjustmentVO /// </Inputs> /// <Returns> /// void /// </Returns> /// <History> /// Thursday, June 23, 2005 /// </History> public void Update(object pobjObjecVO) { const string METHOD_NAME = THIS + ".Update()"; IV_AdjustmentVO objObject = (IV_AdjustmentVO)pobjObjecVO; //prepare value for parameters OleDbConnection oconPCS = null; OleDbCommand ocmdPCS = null; try { string strSql = String.Empty; Utils utils = new Utils(); oconPCS = new OleDbConnection(Utils.Instance.OleDbConnectionString); ocmdPCS = new OleDbCommand(strSql, oconPCS); strSql = "UPDATE IV_Adjustment SET " + IV_AdjustmentTable.MASTERLOCATIONID_FLD + "= ?" + "," + IV_AdjustmentTable.LOCATIONID_FLD + "= ?" + "," + IV_AdjustmentTable.ADJUSTMENTID_FLD + "= ?" + "," + IV_AdjustmentTable.POSTDATE_FLD + "= ?" + "," + IV_AdjustmentTable.COMMENT_FLD + "= ?" + "," + IV_AdjustmentTable.CCNID_FLD + "= ?" + "," + IV_AdjustmentTable.TRANSNO_FLD + "= ?" + "," + IV_AdjustmentTable.PRODUCTID_FLD + "= ?" + "," + IV_AdjustmentTable.STOCKUMID_FLD + "= ?" + "," + IV_AdjustmentTable.SERIAL_FLD + "= ?" + "," + IV_AdjustmentTable.ADJUSTQUANTITY_FLD + "= ?" + "," + IV_AdjustmentTable.LOT_FLD + "= ?" + " WHERE " + IV_AdjustmentTable.BINID_FLD + "= ?"; ocmdPCS.Parameters.Add(new OleDbParameter(IV_AdjustmentTable.MASTERLOCATIONID_FLD, OleDbType.Integer)); ocmdPCS.Parameters[IV_AdjustmentTable.MASTERLOCATIONID_FLD].Value = objObject.MasterLocationID; ocmdPCS.Parameters.Add(new OleDbParameter(IV_AdjustmentTable.LOCATIONID_FLD, OleDbType.Integer)); ocmdPCS.Parameters[IV_AdjustmentTable.LOCATIONID_FLD].Value = objObject.LocationID; ocmdPCS.Parameters.Add(new OleDbParameter(IV_AdjustmentTable.ADJUSTMENTID_FLD, OleDbType.Integer)); ocmdPCS.Parameters[IV_AdjustmentTable.ADJUSTMENTID_FLD].Value = objObject.AdjustmentID; ocmdPCS.Parameters.Add(new OleDbParameter(IV_AdjustmentTable.POSTDATE_FLD, OleDbType.Date)); ocmdPCS.Parameters[IV_AdjustmentTable.POSTDATE_FLD].Value = objObject.PostDate; ocmdPCS.Parameters.Add(new OleDbParameter(IV_AdjustmentTable.COMMENT_FLD, OleDbType.VarWChar)); ocmdPCS.Parameters[IV_AdjustmentTable.COMMENT_FLD].Value = objObject.Comment; ocmdPCS.Parameters.Add(new OleDbParameter(IV_AdjustmentTable.CCNID_FLD, OleDbType.Integer)); ocmdPCS.Parameters[IV_AdjustmentTable.CCNID_FLD].Value = objObject.CCNID; ocmdPCS.Parameters.Add(new OleDbParameter(IV_AdjustmentTable.TRANSNO_FLD, OleDbType.VarWChar)); ocmdPCS.Parameters[IV_AdjustmentTable.TRANSNO_FLD].Value = objObject.TransNo; ocmdPCS.Parameters.Add(new OleDbParameter(IV_AdjustmentTable.PRODUCTID_FLD, OleDbType.Integer)); ocmdPCS.Parameters[IV_AdjustmentTable.PRODUCTID_FLD].Value = objObject.ProductID; ocmdPCS.Parameters.Add(new OleDbParameter(IV_AdjustmentTable.STOCKUMID_FLD, OleDbType.Integer)); ocmdPCS.Parameters[IV_AdjustmentTable.STOCKUMID_FLD].Value = objObject.StockUMID; ocmdPCS.Parameters.Add(new OleDbParameter(IV_AdjustmentTable.SERIAL_FLD, OleDbType.VarWChar)); ocmdPCS.Parameters[IV_AdjustmentTable.SERIAL_FLD].Value = objObject.Serial; ocmdPCS.Parameters.Add(new OleDbParameter(IV_AdjustmentTable.ADJUSTQUANTITY_FLD, OleDbType.Decimal)); ocmdPCS.Parameters[IV_AdjustmentTable.ADJUSTQUANTITY_FLD].Value = objObject.AdjustQuantity; ocmdPCS.Parameters.Add(new OleDbParameter(IV_AdjustmentTable.LOT_FLD, OleDbType.VarWChar)); ocmdPCS.Parameters[IV_AdjustmentTable.LOT_FLD].Value = objObject.Lot; ocmdPCS.Parameters.Add(new OleDbParameter(IV_AdjustmentTable.BINID_FLD, OleDbType.Integer)); ocmdPCS.Parameters[IV_AdjustmentTable.BINID_FLD].Value = objObject.BinID; ocmdPCS.CommandText = strSql; ocmdPCS.Connection.Open(); ocmdPCS.ExecuteNonQuery(); } catch (OleDbException ex) { if (ex.Errors[1].NativeError == ErrorCode.SQLDUPLICATE_KEYCODE) { throw new PCSDBException(ErrorCode.DUPLICATE_KEY, METHOD_NAME, ex); } else { throw new PCSDBException(ErrorCode.ERROR_DB, METHOD_NAME, ex); } } catch (InvalidOperationException ex) { throw new PCSDBException(ErrorCode.ERROR_DB, METHOD_NAME, ex); } catch (Exception ex) { throw new PCSDBException(ErrorCode.OTHER_ERROR, METHOD_NAME, ex); } finally { if (oconPCS != null) { if (oconPCS.State != ConnectionState.Closed) { oconPCS.Close(); } } } }