Exemplo n.º 1
0
        public void TestSinglePointExternalCalibrationWithIsConcentration()
        {
            const double internalStandardConcentration = 80.0;
            var          srmDocument = LoadTestDocument();

            srmDocument = ChangeStandardConcentrationCount(srmDocument, 1);
            srmDocument = ChangeQuantificationSettings(srmDocument, QuantificationSettings.DEFAULT
                                                       .ChangeRegressionFit(RegressionFit.LINEAR_THROUGH_ZERO)
                                                       .ChangeNormalizationMethod(NormalizationMethod.GetNormalizationMethod(IsotopeLabelType.heavy)));
            PeptideGroupDocNode protein = srmDocument.MoleculeGroups.First();
            PeptideDocNode      peptide = protein.Peptides.First();

            peptide = peptide.ChangeInternalStandardConcentration(internalStandardConcentration);
            PeptideQuantifier      peptideQuantifier = PeptideQuantifier.GetPeptideQuantifier(srmDocument.Settings, protein, peptide);
            CalibrationCurveFitter curveFitter       = new CalibrationCurveFitter(peptideQuantifier, srmDocument.Settings);

            Assert.AreEqual(CalibrationCurveFitter.ConcentrationRatioText(IsotopeLabelType.light, IsotopeLabelType.heavy),
                            curveFitter.GetXAxisTitle());
            Assert.AreEqual(CalibrationCurveFitter.PeakAreaRatioText(IsotopeLabelType.light, IsotopeLabelType.heavy), curveFitter.GetYAxisTitle());
            var chromatograms = srmDocument.Settings.MeasuredResults.Chromatograms;

            for (int iReplicate = 0; iReplicate < chromatograms.Count; iReplicate++)
            {
                string msg       = string.Format("Replicate {0}", iReplicate);
                var    expectedY = peptide.Results[iReplicate].First().LabelRatios.First().Ratio.Ratio;
                double?actualY   = curveFitter.GetYValue(iReplicate).Value;
                Assert.IsNotNull(actualY);
                Assert.AreEqual(expectedY, actualY.Value, epsilon, msg);
                var calibrationCurve = curveFitter.GetCalibrationCurve();
                Assert.AreEqual(1, calibrationCurve.PointCount);
                var expectedConcentration = expectedY * internalStandardConcentration / calibrationCurve.Slope.Value;
                Assert.AreEqual(expectedConcentration / internalStandardConcentration,
                                curveFitter.GetCalculatedXValue(calibrationCurve, iReplicate).GetValueOrDefault(double.NaN), epsilon, msg);
                Assert.AreEqual(expectedConcentration,
                                curveFitter.GetCalculatedConcentration(calibrationCurve, iReplicate).GetValueOrDefault(double.NaN), epsilon, msg);
                var chromatogramSet = chromatograms[iReplicate];
                if (Equals(chromatogramSet.SampleType, SampleType.STANDARD) && chromatogramSet.AnalyteConcentration.HasValue)
                {
                    // Since there was only one standard, the regression line goes exactly through this sample.
                    Assert.AreEqual(expectedConcentration, chromatogramSet.AnalyteConcentration.Value * peptide.ConcentrationMultiplier.GetValueOrDefault(1.0), epsilon);
                }
            }
        }
Exemplo n.º 2
0
        public void TestMultipointExternalCalibrationWithoutNormalization()
        {
            var srmDocument = LoadTestDocument();

            srmDocument = ChangeQuantificationSettings(srmDocument,
                                                       QuantificationSettings.DEFAULT
                                                       .ChangeNormalizationMethod(NormalizationMethod.NONE)
                                                       .ChangeRegressionFit(RegressionFit.LINEAR)
                                                       .ChangeUnits("ng/mL"));
            PeptideGroupDocNode protein = srmDocument.MoleculeGroups.First();
            PeptideDocNode      peptide = srmDocument.Peptides.First();

            peptide = peptide.ChangeInternalStandardConcentration(null);
            CalibrationCurveFitter curveFitter = CalibrationCurveFitter.GetCalibrationCurveFitter(srmDocument.Settings, protein, peptide);
            string expectedXAxis = CalibrationCurveFitter.AppendUnits(QuantificationStrings.Analyte_Concentration, "ng/mL");

            Assert.AreEqual(expectedXAxis, curveFitter.GetXAxisTitle());
            string expectedYAxis = QuantificationStrings.CalibrationCurveFitter_GetYAxisTitle_Peak_Area;

            Assert.AreEqual(expectedYAxis, curveFitter.GetYAxisTitle());
            var chromatograms  = srmDocument.Settings.MeasuredResults.Chromatograms;
            var lightPrecursor = peptide.TransitionGroups
                                 .First(tg => IsotopeLabelType.light.Equals(tg.TransitionGroup.LabelType));

            for (int iReplicate = 0; iReplicate < chromatograms.Count; iReplicate++)
            {
                string msg       = string.Format("Replicate {0}", iReplicate);
                var    expectedY = lightPrecursor.Results[iReplicate].First().Area.Value;
                Assert.AreEqual(expectedY, curveFitter.GetYValue(iReplicate).Value, .01, msg);
                var calibrationCurve = curveFitter.GetCalibrationCurve();
                Assert.IsNotNull(calibrationCurve.Slope);
                Assert.IsNotNull(calibrationCurve.RSquared);
                double expectedConcentration = calibrationCurve.GetX(expectedY).Value;
                Assert.AreEqual(expectedConcentration,
                                curveFitter.GetCalculatedXValue(calibrationCurve, iReplicate).GetValueOrDefault(double.NaN), epsilon, msg);
                Assert.AreEqual(expectedConcentration,
                                curveFitter.GetCalculatedConcentration(calibrationCurve, iReplicate).GetValueOrDefault(double.NaN), epsilon, msg);
            }
        }
Exemplo n.º 3
0
        public void TestInternalCalibration()
        {
            const double internalStandardConcentration = 80.0;
            var          srmDocument = LoadTestDocument();

            AssertEx.IsDocumentState(srmDocument, null, 1, 1, 2, 10);
            srmDocument = ChangeStandardConcentrationCount(srmDocument, 0);
            srmDocument = ChangeQuantificationSettings(srmDocument,
                                                       QuantificationSettings.DEFAULT
                                                       .ChangeRegressionFit(RegressionFit.NONE)
                                                       .ChangeNormalizationMethod(NormalizationMethod.GetNormalizationMethod(IsotopeLabelType.heavy))
                                                       .ChangeUnits("ng/mL"));
            PeptideGroupDocNode protein = srmDocument.MoleculeGroups.First();
            PeptideDocNode      peptide = protein.Peptides.First();

            peptide = peptide.ChangeInternalStandardConcentration(internalStandardConcentration);
            CalibrationCurveFitter curveFitter = CalibrationCurveFitter.GetCalibrationCurveFitter(srmDocument.Settings, protein, peptide);
            string expectedXAxis = CalibrationCurveFitter.AppendUnits(QuantificationStrings.Analyte_Concentration, "ng/mL");

            Assert.AreEqual(expectedXAxis, curveFitter.GetXAxisTitle());
            string expectedYAxis = CalibrationCurveFitter.PeakAreaRatioText(IsotopeLabelType.light, IsotopeLabelType.heavy);

            Assert.AreEqual(expectedYAxis, curveFitter.GetYAxisTitle());
            var chromatograms = srmDocument.Settings.MeasuredResults.Chromatograms;

            for (int iReplicate = 0; iReplicate < chromatograms.Count; iReplicate++)
            {
                string msg       = string.Format("Replicate {0}", iReplicate);
                var    expectedY = peptide.Results[iReplicate].First().LabelRatios.First().Ratio.Ratio;
                Assert.AreEqual(expectedY, curveFitter.GetYValue(iReplicate).Value, epsilon, msg);
                var calibrationCurve = curveFitter.GetCalibrationCurve();
                Assert.AreEqual(1 / internalStandardConcentration, calibrationCurve.Slope);
                Assert.IsNull(calibrationCurve.RSquared);
                Assert.AreEqual(expectedY * internalStandardConcentration,
                                curveFitter.GetCalculatedXValue(calibrationCurve, iReplicate).GetValueOrDefault(double.NaN), epsilon, msg);
                Assert.AreEqual(expectedY * internalStandardConcentration,
                                curveFitter.GetCalculatedConcentration(calibrationCurve, iReplicate).GetValueOrDefault(double.NaN), epsilon, msg);
            }
        }