예제 #1
0
 /// <summary>
 ///     Creates this object and sets all its properties
 /// </summary>
 /// <param name="binaryReader"></param>
 /// <param name="size">The size of the monikerstream</param>
 internal MonikerStream(BinaryReader binaryReader, int size)
 {
     // 16 bytes
     Clsid = new CLSID(binaryReader);
     StreamData = binaryReader.ReadBytes(size - 16);
 }
예제 #2
0
 /// <summary>
 ///     Creates this object and sets all its properties
 /// </summary>
 /// <param name="binaryReader"></param>
 /// <param name="size">The size of the monikerstream</param>
 internal MonikerStream(BinaryReader binaryReader, int size)
 {
     // 16 bytes
     Clsid      = new CLSID(binaryReader);
     StreamData = binaryReader.ReadBytes(size - 16);
 }
예제 #3
0
        /// <summary>
        ///     Creates this object and sets all its properties
        /// </summary>
        /// <param name="stream">The Compound File Storage Ole <see cref="CFStream" /></param>
        internal OleStream(CFStream stream)
        {
            using (var memoryStream = new MemoryStream(stream.GetData()))
                using (var binaryReader = new BinaryReader(memoryStream))
                {
                    Version = binaryReader.ReadUInt16();

                    // Flags (4 bytes): If this field is set to 0x00000001, the OLEStream structure MUST be for a linked object and
                    // the CLSID field of the Compound File Directory Entry of the OLE Compound File Storage object MUST be set to
                    // CLSID_StdOleLink ({00000300-0000-0000-C000-000000000046}). If this field is set to 0x00000000, then the OLEStream
                    // structure MUST be for an embedded object and the CLSID field of the Compound File Directory Entry
                    // of the OLE Compound File Storage object MUST be set to the object class GUID of the creating application.
                    var flags = binaryReader.ReadUInt32();

                    switch (flags)
                    {
                    case 0x00000000:
                    case 0x00001000:
                        Format = OleFormat.File;
                        break;

                    case 0x00000001:
                    case 0x00001001:
                        Format = OleFormat.Link;
                        break;
                    }

                    // LinkUpdateOption (4 bytes): This field contains an implementation-specific hint supplied by the application or by
                    // a higher-level protocol that creates the data structure. The hint MAY be ignored on processing of this data structure
                    LinkUpdateOptions = binaryReader.ReadUInt32();

                    //Reserved1 (4 bytes): This MUST be set to 0x00000000. Otherwise, the OLEStream structure is invalid
                    binaryReader.ReadUInt32();

                    // ReservedMonikerStreamSize (4 bytes): This MUST be set to the size, in bytes, of the ReservedMonikerStream field. If this
                    // field has a value 0x00000000, the ReservedMonikerStream field MUST NOT be present.
                    var reservedMonikerStreamSize = (int)binaryReader.ReadUInt32();

                    // ReservedMonikerStream (variable): This MUST be a MONIKERSTREAM structure that can contain any arbitrary
                    // value and MUST be ignored on processing.
                    binaryReader.ReadBytes(reservedMonikerStreamSize);

                    // Note The fields that follow MUST NOT be present if the OLEStream structure is for an embedded object.
                    if (Format == OleFormat.Link)
                    {
                        // RelativeSourceMonikerStreamSize (4 bytes): This MUST be set to the size, in bytes, of the RelativeSourceMonikerStream field.
                        // If this field has a value 0x00000000, the RelativeSourceMonikerStream field MUST NOT be present.
                        var relativeSourceMonikerStreamSize = (int)binaryReader.ReadUInt32();

                        // RelativeSourceMonikerStream (variable): This MUST be a MONIKERSTREAM structure that specifies the relative
                        // path to the linked object.
                        if (relativeSourceMonikerStreamSize > 0)
                        {
                            RelativeSource = new MonikerStream(binaryReader, relativeSourceMonikerStreamSize);
                        }

                        // AbsoluteSourceMonikerStreamSize (4 bytes): This MUST be set to the size, in bytes, of the AbsoluteSourceMonikerStream field.
                        // This field MUST NOT contain the value 0x00000000.
                        var absoluteSourceMonikerStreamSize = (int)binaryReader.ReadUInt32();

                        // AbsoluteSourceMonikerStream (variable): This MUST be a MONIKERSTREAM structure that specifies the full path
                        // to the linked object.
                        if (absoluteSourceMonikerStreamSize > 0)
                        {
                            AbsoluteSource = new MonikerStream(binaryReader, absoluteSourceMonikerStreamSize);
                        }

                        // If the RelativeSourceMonikerStream field is present, it MUST be used by the container application instead of the
                        // AbsoluteSourceMonikerStream. If the RelativeSourceMonikerStream field is not present, the AbsoluteSourceMonikerStream MUST be used
                        // by the container application.

                        // ClsidIndicator (4 bytes): This MUST be the LONG as specified in section value -1. Otherwise the OLEStream
                        // structure is invalid.
                        binaryReader.ReadUInt32();

                        // Clsid (16 bytes): This MUST be the CLSID (Packet) containing the object class GUID of the creating application.
                        Clsid = new CLSID(binaryReader);

                        // ReservedDisplayName (4 bytes): This MUST be a LengthPrefixedUnicodeString that can contain any arbitrary value
                        // and MUST be ignored on processing.
                        binaryReader.ReadUInt32();

                        // Reserved2 (4 bytes): This can contain any arbitrary value and MUST be ignored on processing.
                        binaryReader.ReadUInt32();

                        // LocalUpdateTime (4 bytes): This MUST be a FILETIME (Packet) that contains the time when the container application
                        // last updated the RemoteUpdateTime field.
                        var localUpdateTime = binaryReader.ReadBytes(4).Reverse().ToArray();
                        LocalUpdateTime = DateTime.FromFileTime(BitConverter.ToInt32(localUpdateTime, 0));

                        // LocalCheckUpdateTime (4 bytes): This MUST be a FILETIME (Packet) that contains the time when the container application last
                        // checked the update time of the linked object.
                        var localCheckUpdateTime = binaryReader.ReadBytes(4).Reverse().ToArray();
                        LocalCheckUpdateTime = DateTime.FromFileTime(BitConverter.ToInt32(localCheckUpdateTime, 0));

                        // RemoteUpdateTime (4 bytes): This MUST be a FILETIME (Packet) that contains the time when the linked object was last updated.
                        var remoteUpdateTime = binaryReader.ReadBytes(4).Reverse().ToArray();
                        RemoteUpdateTime = DateTime.FromFileTime(BitConverter.ToInt32(remoteUpdateTime, 0));
                    }
                }
        }
예제 #4
0
        /// <summary>
        ///     Creates this object and sets all its properties
        /// </summary>
        /// <param name="stream">The Compound File Storage Ole <see cref="CFStream" /></param>
        internal OleStream(ICFStream stream)
        {
            using (var memoryStream = new MemoryStream(stream.GetData()))
            using (var binaryReader = new BinaryReader(memoryStream))
            {
                Version = binaryReader.ReadUInt16();

                // Flags (4 bytes): If this field is set to 0x00000001, the OLEStream structure MUST be for a linked object and
                // the CLSID field of the Compound File Directory Entry of the OLE Compound File Storage object MUST be set to 
                // CLSID_StdOleLink ({00000300-0000-0000-C000-000000000046}). If this field is set to 0x00000000, then the OLEStream 
                // structure MUST be for an embedded object and the CLSID field of the Compound File Directory Entry
                // of the OLE Compound File Storage object MUST be set to the object class GUID of the creating application.
                var flags = binaryReader.ReadUInt32();

                switch (flags)
                {
                    case 0x00000000:
                    case 0x00001000:
                        Format = OleFormat.File;
                        break;

                    case 0x00000001:
                    case 0x00001001:
                        Format = OleFormat.Link;
                        break;
                }

                // LinkUpdateOption (4 bytes): This field contains an implementation-specific hint supplied by the application or by
                // a higher-level protocol that creates the data structure. The hint MAY be ignored on processing of this data structure
                LinkUpdateOptions = binaryReader.ReadUInt32();

                //Reserved1 (4 bytes): This MUST be set to 0x00000000. Otherwise, the OLEStream structure is invalid
                binaryReader.ReadUInt32();

                // ReservedMonikerStreamSize (4 bytes): This MUST be set to the size, in bytes, of the ReservedMonikerStream field. If this 
                // field has a value 0x00000000, the ReservedMonikerStream field MUST NOT be present.
                var reservedMonikerStreamSize = (int) binaryReader.ReadUInt32();

                // ReservedMonikerStream (variable): This MUST be a MONIKERSTREAM structure that can contain any arbitrary 
                // value and MUST be ignored on processing.
                binaryReader.ReadBytes(reservedMonikerStreamSize);

                // Note The fields that follow MUST NOT be present if the OLEStream structure is for an embedded object.
                if (Format == OleFormat.Link)
                {
                    // RelativeSourceMonikerStreamSize (4 bytes): This MUST be set to the size, in bytes, of the RelativeSourceMonikerStream field. 
                    // If this field has a value 0x00000000, the RelativeSourceMonikerStream field MUST NOT be present.
                    var relativeSourceMonikerStreamSize = (int) binaryReader.ReadUInt32();

                    // RelativeSourceMonikerStream (variable): This MUST be a MONIKERSTREAM structure that specifies the relative 
                    // path to the linked object.
                    if (relativeSourceMonikerStreamSize > 0)
                        RelativeSource = new MonikerStream(binaryReader, relativeSourceMonikerStreamSize);

                    // AbsoluteSourceMonikerStreamSize (4 bytes): This MUST be set to the size, in bytes, of the AbsoluteSourceMonikerStream field. 
                    // This field MUST NOT contain the value 0x00000000.
                    var absoluteSourceMonikerStreamSize = (int) binaryReader.ReadUInt32();

                    // AbsoluteSourceMonikerStream (variable): This MUST be a MONIKERSTREAM structure that specifies the full path 
                    // to the linked object.
                    if (absoluteSourceMonikerStreamSize > 0)
                        AbsoluteSource = new MonikerStream(binaryReader, absoluteSourceMonikerStreamSize);

                    // If the RelativeSourceMonikerStream field is present, it MUST be used by the container application instead of the 
                    // AbsoluteSourceMonikerStream. If the RelativeSourceMonikerStream field is not present, the AbsoluteSourceMonikerStream MUST be used 
                    // by the container application.

                    // ClsidIndicator (4 bytes): This MUST be the LONG as specified in section value -1. Otherwise the OLEStream 
                    // structure is invalid.
                    binaryReader.ReadUInt32();

                    // Clsid (16 bytes): This MUST be the CLSID (Packet) containing the object class GUID of the creating application.
                    Clsid = new CLSID(binaryReader);

                    // ReservedDisplayName (4 bytes): This MUST be a LengthPrefixedUnicodeString that can contain any arbitrary value 
                    // and MUST be ignored on processing.
                    binaryReader.ReadUInt32();

                    // Reserved2 (4 bytes): This can contain any arbitrary value and MUST be ignored on processing.
                    binaryReader.ReadUInt32();

                    // LocalUpdateTime (4 bytes): This MUST be a FILETIME (Packet) that contains the time when the container application 
                    // last updated the RemoteUpdateTime field.
                    var localUpdateTime = binaryReader.ReadBytes(4).Reverse().ToArray();
                    LocalUpdateTime = DateTime.FromFileTime(BitConverter.ToInt32(localUpdateTime, 0));

                    // LocalCheckUpdateTime (4 bytes): This MUST be a FILETIME (Packet) that contains the time when the container application last 
                    // checked the update time of the linked object.
                    var localCheckUpdateTime = binaryReader.ReadBytes(4).Reverse().ToArray();
                    LocalCheckUpdateTime = DateTime.FromFileTime(BitConverter.ToInt32(localCheckUpdateTime, 0));

                    // RemoteUpdateTime (4 bytes): This MUST be a FILETIME (Packet) that contains the time when the linked object was last updated.
                    var remoteUpdateTime = binaryReader.ReadBytes(4).Reverse().ToArray();
                    RemoteUpdateTime = DateTime.FromFileTime(BitConverter.ToInt32(remoteUpdateTime, 0));
                }
            }
        }