private async Task <byte[]> ProcessLoraMessage(LoRaMessageWrapper loraMessage) { bool validFrameCounter = false; byte[] udpMsgForPktForwarder = new byte[0]; string devAddr = ConversionHelper.ByteArrayToString(loraMessage.LoRaPayloadMessage.DevAddr.ToArray()); Message c2dMsg = null; Cache.TryGetValue(devAddr, out LoraDeviceInfo loraDeviceInfo); if (loraDeviceInfo == null || !loraDeviceInfo.IsOurDevice) { loraDeviceInfo = await LoraDeviceInfoManager.GetLoraDeviceInfoAsync(devAddr, GatewayID); if (loraDeviceInfo.DevEUI != null) { Logger.Log(loraDeviceInfo.DevEUI, $"processing message, device not in cache", Logger.LoggingLevel.Info); } else { Logger.Log(devAddr, $"processing message, device not in cache", Logger.LoggingLevel.Info); } Cache.AddToCache(devAddr, loraDeviceInfo); } else { Logger.Log(loraDeviceInfo.DevEUI, $"processing message, device in cache", Logger.LoggingLevel.Info); } if (loraDeviceInfo != null && loraDeviceInfo.IsOurDevice) { //either there is no gateway linked to the device or the gateway is the one that the code is running if (String.IsNullOrEmpty(loraDeviceInfo.GatewayID) || loraDeviceInfo.GatewayID.ToUpper() == GatewayID.ToUpper()) { if (loraMessage.CheckMic(loraDeviceInfo.NwkSKey)) { if (loraDeviceInfo.HubSender == null) { loraDeviceInfo.HubSender = new IoTHubConnector(loraDeviceInfo.DevEUI, loraDeviceInfo.PrimaryKey); } UInt16 fcntup = BitConverter.ToUInt16(loraMessage.LoRaPayloadMessage.GetLoRaMessage().Fcnt.ToArray(), 0); byte[] linkCheckCmdResponse = null; //check if the frame counter is valid: either is above the server one or is an ABP device resetting the counter (relaxed seqno checking) if (fcntup > loraDeviceInfo.FCntUp || (fcntup == 0 && loraDeviceInfo.FCntUp == 0) || (fcntup == 1 && String.IsNullOrEmpty(loraDeviceInfo.AppEUI))) { //save the reset fcnt for ABP (relaxed seqno checking) if (fcntup == 1 && String.IsNullOrEmpty(loraDeviceInfo.AppEUI)) { _ = loraDeviceInfo.HubSender.UpdateFcntAsync(fcntup, 0, true); //if the device is not attached to a gateway we need to reset the abp fcnt server side cache if (String.IsNullOrEmpty(loraDeviceInfo.GatewayID)) { bool rit = await LoraDeviceInfoManager.ABPFcntCacheReset(loraDeviceInfo.DevEUI); } } validFrameCounter = true; Logger.Log(loraDeviceInfo.DevEUI, $"valid frame counter, msg: {fcntup} server: {loraDeviceInfo.FCntUp}", Logger.LoggingLevel.Info); byte[] decryptedMessage = null; try { decryptedMessage = loraMessage.DecryptPayload(loraDeviceInfo.AppSKey); } catch (Exception ex) { Logger.Log(loraDeviceInfo.DevEUI, $"failed to decrypt message: {ex.Message}", Logger.LoggingLevel.Error); } Rxpk rxPk = loraMessage.PktFwdPayload.GetPktFwdMessage().Rxpks[0]; dynamic fullPayload = JObject.FromObject(rxPk); string jsonDataPayload = ""; uint fportUp = 0; bool isAckFromDevice = false; if (loraMessage.LoRaPayloadMessage.GetLoRaMessage().Fport.Span.Length > 0) { fportUp = (uint)loraMessage.LoRaPayloadMessage.GetLoRaMessage().Fport.Span[0]; } else // this is an acknowledgment sent from the device { isAckFromDevice = true; fullPayload.deviceAck = true; } fullPayload.port = fportUp; fullPayload.fcnt = fcntup; if (isAckFromDevice) { jsonDataPayload = Convert.ToBase64String(decryptedMessage); fullPayload.data = jsonDataPayload; } else { Logger.Log(loraDeviceInfo.DevEUI, $"decoding with: {loraDeviceInfo.SensorDecoder} port: {fportUp}", Logger.LoggingLevel.Info); fullPayload.data = await LoraDecoders.DecodeMessage(decryptedMessage, fportUp, loraDeviceInfo.SensorDecoder); } fullPayload.eui = loraDeviceInfo.DevEUI; fullPayload.gatewayid = GatewayID; //Edge timestamp fullPayload.edgets = (long)((startTimeProcessing - new DateTime(1970, 1, 1)).TotalMilliseconds); List <KeyValuePair <String, String> > messageProperties = new List <KeyValuePair <String, String> >(); //Parsing MacCommands and add them as property of the message to be sent to the IoT Hub. var macCommand = ((LoRaPayloadData)loraMessage.LoRaPayloadMessage).GetMacCommands(); if (macCommand.macCommand.Count > 0) { for (int i = 0; i < macCommand.macCommand.Count; i++) { messageProperties.Add(new KeyValuePair <string, string>(macCommand.macCommand[i].Cid.ToString(), value: JsonConvert.SerializeObject(macCommand.macCommand[i], Newtonsoft.Json.Formatting.None))); //in case it is a link check mac, we need to send it downstream. if (macCommand.macCommand[i].Cid == CidEnum.LinkCheckCmd) { linkCheckCmdResponse = new LinkCheckCmd(rxPk.GetModulationMargin(), 1).ToBytes(); } } } string iotHubMsg = fullPayload.ToString(Newtonsoft.Json.Formatting.None); await loraDeviceInfo.HubSender.SendMessageAsync(iotHubMsg, messageProperties); if (isAckFromDevice) { Logger.Log(loraDeviceInfo.DevEUI, $"ack from device sent to hub", Logger.LoggingLevel.Info); } else { var fullPayloadAsString = fullPayload.data as string; if (fullPayloadAsString == null) { fullPayloadAsString = ((JObject)fullPayload.data).ToString(Formatting.None); } Logger.Log(loraDeviceInfo.DevEUI, $"message '{fullPayloadAsString}' sent to hub", Logger.LoggingLevel.Info); } loraDeviceInfo.FCntUp = fcntup; } else { validFrameCounter = false; Logger.Log(loraDeviceInfo.DevEUI, $"invalid frame counter, msg: {fcntup} server: {loraDeviceInfo.FCntUp}", Logger.LoggingLevel.Info); } //we lock as fast as possible and get the down fcnt for multi gateway support for confirmed message if (loraMessage.LoRaMessageType == LoRaMessageType.ConfirmedDataUp && String.IsNullOrEmpty(loraDeviceInfo.GatewayID)) { ushort newFCntDown = await LoraDeviceInfoManager.NextFCntDown(loraDeviceInfo.DevEUI, loraDeviceInfo.FCntDown, fcntup, GatewayID); //ok to send down ack or msg if (newFCntDown > 0) { loraDeviceInfo.FCntDown = newFCntDown; } //another gateway was first with this message we simply drop else { PhysicalPayload pushAck = new PhysicalPayload(loraMessage.PhysicalPayload.token, PhysicalIdentifier.PUSH_ACK, null); udpMsgForPktForwarder = pushAck.GetMessage(); Logger.Log(loraDeviceInfo.DevEUI, $"another gateway has already sent ack or downlink msg", Logger.LoggingLevel.Info); Logger.Log(loraDeviceInfo.DevEUI, $"processing time: {DateTime.UtcNow - startTimeProcessing}", Logger.LoggingLevel.Info); return(udpMsgForPktForwarder); } } //start checking for new c2d message, we do it even if the fcnt is invalid so we support replying to the ConfirmedDataUp //todo ronnie should we wait up to 900 msec? c2dMsg = await loraDeviceInfo.HubSender.ReceiveAsync(TimeSpan.FromMilliseconds(20)); byte[] bytesC2dMsg = null; byte[] fport = null; //Todo revamp fctrl byte[] fctrl = new byte[1] { 32 }; //check if we got a c2d message to be added in the ack message and prepare the message if (c2dMsg != null) { ////check if there is another message var secondC2dMsg = await loraDeviceInfo.HubSender.ReceiveAsync(TimeSpan.FromMilliseconds(20)); if (secondC2dMsg != null) { //put it back to the queue for the next pickup //todo ronnie check abbandon logic especially in case of mqtt _ = await loraDeviceInfo.HubSender.AbandonAsync(secondC2dMsg); //set the fpending flag so the lora device will call us back for the next message fctrl = new byte[1] { 48 }; } bytesC2dMsg = c2dMsg.GetBytes(); fport = new byte[1] { 1 }; if (bytesC2dMsg != null) { Logger.Log(loraDeviceInfo.DevEUI, $"C2D message: {Encoding.UTF8.GetString(bytesC2dMsg)}", Logger.LoggingLevel.Info); } //todo ronnie implement a better max payload size by datarate //cut to the max payload of lora for any EU datarate if (bytesC2dMsg.Length > 51) { Array.Resize(ref bytesC2dMsg, 51); } Array.Reverse(bytesC2dMsg); } //if confirmation or cloud to device msg send down the message if (loraMessage.LoRaMessageType == LoRaMessageType.ConfirmedDataUp || c2dMsg != null) { //check if we are not too late for the second receive windows if ((DateTime.UtcNow - startTimeProcessing) <= TimeSpan.FromMilliseconds(RegionFactory.CurrentRegion.receive_delay2 * 1000 - 100)) { //if running in multigateway we need to use redis to sync the down fcnt if (!String.IsNullOrEmpty(loraDeviceInfo.GatewayID)) { loraDeviceInfo.FCntDown++; } else if (loraMessage.LoRaMessageType == LoRaMessageType.UnconfirmedDataUp) { ushort newFCntDown = await LoraDeviceInfoManager.NextFCntDown(loraDeviceInfo.DevEUI, loraDeviceInfo.FCntDown, fcntup, GatewayID); //ok to send down ack or msg if (newFCntDown > 0) { loraDeviceInfo.FCntDown = newFCntDown; } //another gateway was first with this message we simply drop else { PhysicalPayload pushAck = new PhysicalPayload(loraMessage.PhysicalPayload.token, PhysicalIdentifier.PUSH_ACK, null); udpMsgForPktForwarder = pushAck.GetMessage(); Logger.Log(loraDeviceInfo.DevEUI, $"another gateway has already sent ack or downlink msg", Logger.LoggingLevel.Info); Logger.Log(loraDeviceInfo.DevEUI, $"processing time: {DateTime.UtcNow - startTimeProcessing}", Logger.LoggingLevel.Info); return(udpMsgForPktForwarder); } } Logger.Log(loraDeviceInfo.DevEUI, $"down frame counter: {loraDeviceInfo.FCntDown}", Logger.LoggingLevel.Info); //Saving both fcnts to twins _ = loraDeviceInfo.HubSender.UpdateFcntAsync(loraDeviceInfo.FCntUp, loraDeviceInfo.FCntDown); //todo need implementation of current configuation to implement this as this depends on RX1DROffset //var _datr = ((UplinkPktFwdMessage)loraMessage.LoraMetadata.FullPayload).rxpk[0].datr; var datr = RegionFactory.CurrentRegion.GetDownstreamDR(loraMessage.PktFwdPayload.GetPktFwdMessage().Rxpks[0]); //todo should discuss about the logic in case of multi channel gateway. uint rfch = loraMessage.PktFwdPayload.GetPktFwdMessage().Rxpks[0].rfch; //todo should discuss about the logic in case of multi channel gateway double freq = RegionFactory.CurrentRegion.GetDownstreamChannel(loraMessage.PktFwdPayload.GetPktFwdMessage().Rxpks[0]); //if we are already longer than 900 mssecond move to the 2 second window //uncomment the following line to force second windows usage TODO change this to a proper expression? //Thread.Sleep(901 long tmst = loraMessage.PktFwdPayload.GetPktFwdMessage().Rxpks[0].tmst + RegionFactory.CurrentRegion.receive_delay1 * 1000000; if ((DateTime.UtcNow - startTimeProcessing) > TimeSpan.FromMilliseconds(RegionFactory.CurrentRegion.receive_delay1 * 1000 - 100)) { fctrl = new byte[1] { 32 }; if (string.IsNullOrEmpty(Environment.GetEnvironmentVariable("RX2_DATR"))) { Logger.Log(loraDeviceInfo.DevEUI, $"using standard second receive windows", Logger.LoggingLevel.Info); tmst = loraMessage.PktFwdPayload.GetPktFwdMessage().Rxpks[0].tmst + RegionFactory.CurrentRegion.receive_delay2 * 1000000; freq = RegionFactory.CurrentRegion.RX2DefaultReceiveWindows.frequency; datr = RegionFactory.CurrentRegion.DRtoConfiguration[RegionFactory.CurrentRegion.RX2DefaultReceiveWindows.dr].configuration; } //if specific twins are set, specify second channel to be as specified else { freq = double.Parse(Environment.GetEnvironmentVariable("RX2_FREQ")); datr = Environment.GetEnvironmentVariable("RX2_DATR"); Logger.Log(loraDeviceInfo.DevEUI, $"using custom DR second receive windows freq : {freq}, datr:{datr}", Logger.LoggingLevel.Info); } } Byte[] devAddrCorrect = new byte[4]; Array.Copy(loraMessage.LoRaPayloadMessage.DevAddr.ToArray(), devAddrCorrect, 4); Array.Reverse(devAddrCorrect); bool requestForConfirmedResponse = false; //check if the c2d message has a mac command byte[] macbytes = null; if (c2dMsg != null) { var macCmd = c2dMsg.Properties.Where(o => o.Key == "CidType"); if (macCmd.Count() != 0) { MacCommandHolder macCommandHolder = new MacCommandHolder(Convert.ToByte(macCmd.First().Value)); macbytes = macCommandHolder.macCommand[0].ToBytes(); } var confirmCmd = c2dMsg.Properties.Where(o => o.Key == "Confirmed"); if (confirmCmd.Count() != 0) { requestForConfirmedResponse = true; } } if (requestForConfirmedResponse) { fctrl[0] += 16; } if (macbytes != null && linkCheckCmdResponse != null) { macbytes = macbytes.Concat(linkCheckCmdResponse).ToArray(); } LoRaPayloadData ackLoRaMessage = new LoRaPayloadData( requestForConfirmedResponse ? MType.ConfirmedDataDown : MType.UnconfirmedDataDown, //ConversionHelper.StringToByteArray(requestForConfirmedResponse?"A0":"60"), devAddrCorrect, fctrl, BitConverter.GetBytes(loraDeviceInfo.FCntDown), macbytes, fport, bytesC2dMsg, 1); ackLoRaMessage.PerformEncryption(loraDeviceInfo.AppSKey); ackLoRaMessage.SetMic(loraDeviceInfo.NwkSKey); byte[] rndToken = new byte[2]; Random rnd = new Random(); rnd.NextBytes(rndToken); //todo ronnie should check the device twin preference if using confirmed or unconfirmed down LoRaMessageWrapper ackMessage = new LoRaMessageWrapper(ackLoRaMessage, LoRaMessageType.UnconfirmedDataDown, rndToken, datr, 0, freq, tmst); udpMsgForPktForwarder = ackMessage.PhysicalPayload.GetMessage(); linkCheckCmdResponse = null; //confirm the message to iot hub only if we are in time for a delivery if (c2dMsg != null) { //todo ronnie check if it is ok to do async so we make it in time to send the message _ = loraDeviceInfo.HubSender.CompleteAsync(c2dMsg); //bool rit = await loraDeviceInfo.HubSender.CompleteAsync(c2dMsg); //if (rit) // Logger.Log(loraDeviceInfo.DevEUI, $"completed the c2d msg to IoT Hub", Logger.LoggingLevel.Info); //else //{ // //we could not complete the msg so we send only a pushAck // PhysicalPayload pushAck = new PhysicalPayload(loraMessage.PhysicalPayload.token, PhysicalIdentifier.PUSH_ACK, null); // udpMsgForPktForwarder = pushAck.GetMessage(); // Logger.Log(loraDeviceInfo.DevEUI, $"could not complete the c2d msg to IoT Hub", Logger.LoggingLevel.Info); //} } } else { PhysicalPayload pushAck = new PhysicalPayload(loraMessage.PhysicalPayload.token, PhysicalIdentifier.PUSH_ACK, null); udpMsgForPktForwarder = pushAck.GetMessage(); //put back the c2d message to the queue for the next round //todo ronnie check abbandon logic especially in case of mqtt if (c2dMsg != null) { _ = await loraDeviceInfo.HubSender.AbandonAsync(c2dMsg); } Logger.Log(loraDeviceInfo.DevEUI, $"too late for down message, sending only ACK to gateway", Logger.LoggingLevel.Info); _ = loraDeviceInfo.HubSender.UpdateFcntAsync(loraDeviceInfo.FCntUp, null); } } //No ack requested and no c2d message we send the udp ack only to the gateway else if (loraMessage.LoRaMessageType == LoRaMessageType.UnconfirmedDataUp && c2dMsg == null) { PhysicalPayload pushAck = new PhysicalPayload(loraMessage.PhysicalPayload.token, PhysicalIdentifier.PUSH_ACK, null); udpMsgForPktForwarder = pushAck.GetMessage(); ////if ABP and 1 we reset the counter (loose frame counter) with force, if not we update normally //if (fcntup == 1 && String.IsNullOrEmpty(loraDeviceInfo.AppEUI)) // _ = loraDeviceInfo.HubSender.UpdateFcntAsync(fcntup, null, true); if (validFrameCounter) { _ = loraDeviceInfo.HubSender.UpdateFcntAsync(loraDeviceInfo.FCntUp, null); } } //If there is a link check command waiting if (linkCheckCmdResponse != null) { Byte[] devAddrCorrect = new byte[4]; Array.Copy(loraMessage.LoRaPayloadMessage.DevAddr.ToArray(), devAddrCorrect, 4); byte[] fctrl2 = new byte[1] { 32 }; Array.Reverse(devAddrCorrect); LoRaPayloadData macReply = new LoRaPayloadData(MType.ConfirmedDataDown, devAddrCorrect, fctrl2, BitConverter.GetBytes(loraDeviceInfo.FCntDown), null, new byte[1] { 0 }, linkCheckCmdResponse, 1); macReply.PerformEncryption(loraDeviceInfo.AppSKey); macReply.SetMic(loraDeviceInfo.NwkSKey); byte[] rndToken = new byte[2]; Random rnd = new Random(); rnd.NextBytes(rndToken); var datr = RegionFactory.CurrentRegion.GetDownstreamDR(loraMessage.PktFwdPayload.GetPktFwdMessage().Rxpks[0]); //todo should discuss about the logic in case of multi channel gateway. uint rfch = loraMessage.PktFwdPayload.GetPktFwdMessage().Rxpks[0].rfch; double freq = RegionFactory.CurrentRegion.GetDownstreamChannel(loraMessage.PktFwdPayload.GetPktFwdMessage().Rxpks[0]); long tmst = loraMessage.PktFwdPayload.GetPktFwdMessage().Rxpks[0].tmst + RegionFactory.CurrentRegion.receive_delay1 * 1000000; //todo ronnie should check the device twin preference if using confirmed or unconfirmed down LoRaMessageWrapper ackMessage = new LoRaMessageWrapper(macReply, LoRaMessageType.UnconfirmedDataDown, rndToken, datr, 0, freq, tmst); udpMsgForPktForwarder = ackMessage.PhysicalPayload.GetMessage(); } } else { Logger.Log(loraDeviceInfo.DevEUI, $"with devAddr {devAddr} check MIC failed. Device will be ignored from now on", Logger.LoggingLevel.Info); loraDeviceInfo.IsOurDevice = false; } } else { Logger.Log(loraDeviceInfo.DevEUI, $"ignore message because is not linked to this GatewayID", Logger.LoggingLevel.Info); } } else { Logger.Log(devAddr, $"device is not our device, ignore message", Logger.LoggingLevel.Info); } Logger.Log(loraDeviceInfo.DevEUI, $"processing time: {DateTime.UtcNow - startTimeProcessing}", Logger.LoggingLevel.Info); return(udpMsgForPktForwarder); }
private async Task <byte[]> ProcessLoraMessage(LoRaMessage loraMessage) { bool validFrameCounter = false; byte[] udpMsgForPktForwarder = new byte[0]; string devAddr = BitConverter.ToString(loraMessage.payloadMessage.devAddr).Replace("-", ""); Message c2dMsg = null; Cache.TryGetValue(devAddr, out LoraDeviceInfo loraDeviceInfo); if (loraDeviceInfo == null) { loraDeviceInfo = await LoraDeviceInfoManager.GetLoraDeviceInfoAsync(devAddr); Logger.Log(loraDeviceInfo.DevEUI, $"processing message, device not in cache", Logger.LoggingLevel.Info); Cache.AddToCache(devAddr, loraDeviceInfo); } else { Logger.Log(loraDeviceInfo.DevEUI, $"processing message, device in cache", Logger.LoggingLevel.Info); } if (loraDeviceInfo.IsOurDevice) { //either there is no gateway linked to the device or the gateway is the one that the code is running if (String.IsNullOrEmpty(loraDeviceInfo.GatewayID) || loraDeviceInfo.GatewayID.ToUpper() == GatewayID.ToUpper()) { if (loraMessage.CheckMic(loraDeviceInfo.NwkSKey)) { if (loraDeviceInfo.HubSender == null) { loraDeviceInfo.HubSender = new IoTHubSender(loraDeviceInfo.DevEUI, loraDeviceInfo.PrimaryKey); } UInt16 fcntup = BitConverter.ToUInt16(((LoRaPayloadStandardData)loraMessage.payloadMessage).fcnt, 0); //check if the frame counter is valid: either is above the server one or is an ABP device resetting the counter (relaxed seqno checking) if (fcntup > loraDeviceInfo.FCntUp || (fcntup == 1 && String.IsNullOrEmpty(loraDeviceInfo.AppEUI))) { //save the reset fcnt for ABP (relaxed seqno checking) if (fcntup == 1 && String.IsNullOrEmpty(loraDeviceInfo.AppEUI)) { _ = loraDeviceInfo.HubSender.UpdateFcntAsync(fcntup, 0, true); } validFrameCounter = true; Logger.Log(loraDeviceInfo.DevEUI, $"valid frame counter, msg: {fcntup} server: {loraDeviceInfo.FCntUp}", Logger.LoggingLevel.Info); byte[] decryptedMessage = null; try { decryptedMessage = loraMessage.DecryptPayload(loraDeviceInfo.AppSKey); } catch (Exception ex) { Logger.Log(loraDeviceInfo.DevEUI, $"failed to decrypt message: {ex.Message}", Logger.LoggingLevel.Error); } Rxpk rxPk = ((UplinkPktFwdMessage)loraMessage.loraMetadata.fullPayload).rxpk[0]; dynamic fullPayload = JObject.FromObject(rxPk); string jsonDataPayload = ""; uint fportUp = (uint)((LoRaPayloadStandardData)loraMessage.payloadMessage).fport[0]; fullPayload.port = fportUp; fullPayload.fcnt = fcntup; if (String.IsNullOrEmpty(loraDeviceInfo.SensorDecoder)) { jsonDataPayload = Convert.ToBase64String(decryptedMessage); fullPayload.data = jsonDataPayload; } else { Logger.Log(loraDeviceInfo.DevEUI, $"decoding with: {loraDeviceInfo.SensorDecoder} port: {fportUp}", Logger.LoggingLevel.Info); jsonDataPayload = LoraDecoders.DecodeMessage(decryptedMessage, fportUp, loraDeviceInfo.SensorDecoder); fullPayload.data = JObject.Parse(jsonDataPayload); } fullPayload.eui = loraDeviceInfo.DevEUI; fullPayload.gatewayid = GatewayID; //todo check what the other ts are if milliseconds or seconds fullPayload.edgets = (long)((startTimeProcessing - new DateTime(1970, 1, 1)).TotalMilliseconds); string iotHubMsg = fullPayload.ToString(Newtonsoft.Json.Formatting.None); await loraDeviceInfo.HubSender.SendMessageAsync(iotHubMsg); Logger.Log(loraDeviceInfo.DevEUI, $"sent message '{jsonDataPayload}' to hub", Logger.LoggingLevel.Info); loraDeviceInfo.FCntUp = fcntup; } else { validFrameCounter = false; Logger.Log(loraDeviceInfo.DevEUI, $"invalid frame counter, msg: {fcntup} server: {loraDeviceInfo.FCntUp}", Logger.LoggingLevel.Info); } //start checking for new c2d message, we do it even if the fcnt is invalid so we support replying to the ConfirmedDataUp //todo ronnie should we wait up to 900 msec? c2dMsg = await loraDeviceInfo.HubSender.ReceiveAsync(TimeSpan.FromMilliseconds(20)); byte[] bytesC2dMsg = null; byte[] fport = null; byte[] fctl = new byte[1] { 32 }; //check if we got a c2d message to be added in the ack message and preprare the message if (c2dMsg != null) { //check if there is another message var secondC2dMsg = await loraDeviceInfo.HubSender.ReceiveAsync(TimeSpan.FromMilliseconds(20)); if (secondC2dMsg != null) { //put it back to the queue for the next pickup _ = loraDeviceInfo.HubSender.AbandonAsync(secondC2dMsg); //set the fpending flag so the lora device will call us back for the next message fctl = new byte[1] { 48 }; } bytesC2dMsg = c2dMsg.GetBytes(); fport = new byte[1] { 1 }; if (bytesC2dMsg != null) { Logger.Log(loraDeviceInfo.DevEUI, $"C2D message: {Encoding.UTF8.GetString(bytesC2dMsg)}", Logger.LoggingLevel.Info); } //todo ronnie implement a better max payload size by datarate //cut to the max payload of lora for any EU datarate if (bytesC2dMsg.Length > 51) { Array.Resize(ref bytesC2dMsg, 51); } Array.Reverse(bytesC2dMsg); } //if confirmation or cloud to device msg send down the message if (loraMessage.loRaMessageType == LoRaMessageType.ConfirmedDataUp || c2dMsg != null) { //check if we are not too late for the 1 and 2 window if (((DateTime.UtcNow - startTimeProcessing) <= TimeSpan.FromMilliseconds(1900))) { //increase the fcnt down and save it to iot hub twins loraDeviceInfo.FCntDown++; Logger.Log(loraDeviceInfo.DevEUI, $"down frame counter: {loraDeviceInfo.FCntDown}", Logger.LoggingLevel.Info); //Saving both fcnts to twins _ = loraDeviceInfo.HubSender.UpdateFcntAsync(loraDeviceInfo.FCntUp, loraDeviceInfo.FCntDown); var _datr = ((UplinkPktFwdMessage)loraMessage.loraMetadata.fullPayload).rxpk[0].datr; uint _rfch = ((UplinkPktFwdMessage)loraMessage.loraMetadata.fullPayload).rxpk[0].rfch; double _freq = ((UplinkPktFwdMessage)loraMessage.loraMetadata.fullPayload).rxpk[0].freq; uint txDelay = 0; //if we are already longer than 900 mssecond move to the 2 second window //uncomment to force second windows usage //Thread.Sleep(901); if ((DateTime.UtcNow - startTimeProcessing) > TimeSpan.FromMilliseconds(900)) { if (!string.IsNullOrEmpty(Environment.GetEnvironmentVariable("RX2_DATR"))) { Logger.Log(loraDeviceInfo.DevEUI, $"using standard second receive windows", Logger.LoggingLevel.Info); //using EU fix DR for RX2 _freq = 869.525; _datr = "SF12BW125"; } //if specific twins are set, specify second channel to be as specified else { _freq = double.Parse(Environment.GetEnvironmentVariable("RX2_FREQ")); _datr = Environment.GetEnvironmentVariable("RX2_DATR"); Logger.Log(loraDeviceInfo.DevEUI, $"using custom DR second receive windows freq : {_freq}, datr:{_datr}", Logger.LoggingLevel.Info); } txDelay = 1000000; } long _tmst = ((UplinkPktFwdMessage)loraMessage.loraMetadata.fullPayload).rxpk[0].tmst + txDelay; Byte[] devAddrCorrect = new byte[4]; Array.Copy(loraMessage.payloadMessage.devAddr, devAddrCorrect, 4); Array.Reverse(devAddrCorrect); //todo mik check what is the A0 LoRaPayloadStandardData ackLoRaMessage = new LoRaPayloadStandardData(StringToByteArray("A0"), devAddrCorrect, fctl, BitConverter.GetBytes(loraDeviceInfo.FCntDown), null, fport, bytesC2dMsg, 1); ackLoRaMessage.PerformEncryption(loraDeviceInfo.AppSKey); ackLoRaMessage.SetMic(loraDeviceInfo.NwkSKey); byte[] rndToken = new byte[2]; Random rnd = new Random(); rnd.NextBytes(rndToken); //todo ronnie should check the device twin preference if using confirmed or unconfirmed down LoRaMessage ackMessage = new LoRaMessage(ackLoRaMessage, LoRaMessageType.ConfirmedDataDown, rndToken, _datr, 0, _freq, _tmst); udpMsgForPktForwarder = ackMessage.physicalPayload.GetMessage(); //confirm the message to iot hub only if we are in time for a delivery if (c2dMsg != null) { _ = loraDeviceInfo.HubSender.CompleteAsync(c2dMsg); Logger.Log(loraDeviceInfo.DevEUI, $"complete the c2d msg to IoT Hub", Logger.LoggingLevel.Info); } } else { PhysicalPayload pushAck = new PhysicalPayload(loraMessage.physicalPayload.token, PhysicalIdentifier.PUSH_ACK, null); udpMsgForPktForwarder = pushAck.GetMessage(); _ = loraDeviceInfo.HubSender.UpdateFcntAsync(loraDeviceInfo.FCntUp, null); //put back the c2d message to the queue for the next round _ = loraDeviceInfo.HubSender.AbandonAsync(c2dMsg); Logger.Log(loraDeviceInfo.DevEUI, $"too late for down message, sending only ACK to gateway", Logger.LoggingLevel.Info); } } //No ack requested and no c2d message we send the udp ack only to the gateway else if (loraMessage.loRaMessageType == LoRaMessageType.UnconfirmedDataUp && c2dMsg == null) { PhysicalPayload pushAck = new PhysicalPayload(loraMessage.physicalPayload.token, PhysicalIdentifier.PUSH_ACK, null); udpMsgForPktForwarder = pushAck.GetMessage(); if (validFrameCounter) { _ = loraDeviceInfo.HubSender.UpdateFcntAsync(loraDeviceInfo.FCntUp, null); } } } else { Logger.Log(loraDeviceInfo.DevEUI, $"with devAddr {devAddr} check MIC failed. Device will be ignored from now on", Logger.LoggingLevel.Info); loraDeviceInfo.IsOurDevice = false; } } else { Logger.Log(loraDeviceInfo.DevEUI, $"ignore message because is not linked to this GatewayID", Logger.LoggingLevel.Info); } } else { Logger.Log(devAddr, $"device with devAddr {devAddr} is not our device, ignore message", Logger.LoggingLevel.Info); } Logger.Log(loraDeviceInfo.DevEUI, $"processing time: {DateTime.UtcNow - startTimeProcessing}", Logger.LoggingLevel.Info); return(udpMsgForPktForwarder); }