예제 #1
0
        public void Station06OOperator02ScannerConnect(MainNetworkClass networkmain)
        {
            if (OP2CognexScanner != null)//change this to comport
            {
                try {
                    OP2CognexScanner.Close();
                } catch (Exception ex) { log.Error("Operator2 scanner unable to close exception " + ex.ToString()); }
                //  OP2CognexScanner = null;
            }
            XmlDocument doc = new XmlDocument();

            doc.Load(@"Config.xml");
            XmlNode Scannernode = doc.SelectSingleNode(@"/CONFIG/SCANNER2/PORT");
            String  comport     = Scannernode.InnerText;
            XmlNode tryingtime  = doc.SelectSingleNode(@"/CONFIG/SCANNER2/TRYINGTIME");

            X = int.Parse(tryingtime.InnerText);
            try {
                if (OP2CognexScanner == null)
                {
                    OP2CognexScanner          = new SerialPort(comport);
                    OP2CognexScanner.BaudRate = 9600;
                    OP2CognexScanner.Parity   = Parity.None;
                    OP2CognexScanner.StopBits = StopBits.One;
                    OP2CognexScanner.DataBits = 8;
                }
                OP2CognexScanner.Open();
            } catch (Exception ex) {
                log.Error("Operator2 scanner exception " + ex.ToString());
                networkmain.linePack.Error("Operator2 scanner exception " + ex.ToString());
                //OP2CognexScanner = null;
            }
        }
        public void RunStation06Operator02Scan(object msgobj)
        {
            MainNetworkClass networkmain = (MainNetworkClass)msgobj;

            Operator02State = 0;
            int    retrycounter = 0;
            bool   ETI2Down     = false;
            string barcode;

            byte[] tmparray = new byte[10];
            while (!bTerminate)
            {
                Thread.Sleep(100);
                int   tmp0          = ((6221 - 6000) * 2) + 11;                                //EVENT ID Calculation
                Int16 QC2ETIMonitor = (Int16)(BitConverter.ToInt16(PLCQueryRxParaPlc2, tmp0)); //DM6221

                if (QC2ETIMonitor == 6057 && ETI2Down == false)
                {
                    MyEventQ.AddQ("657;QC2 ETI BUTTON TRIGGER;QcstationNumber;2;OperatorName;" + UserName2);
                    ETI2Down = true;
                }
                else if (QC2ETIMonitor == 0)
                {
                    ETI2Down = false;
                }
                try
                {
                    // JustLogIn(2);
                    if ((PLCQueryRx6[PLCQueryRx_DM5100 + 64] == 0x01))
                    {
                        SafetyStatus2 = AreaStatus.Block;
                    }
                    else if ((PLCQueryRx6[PLCQueryRx_DM5100 + 66] == 99))
                    {
                        SafetyStatus2 = AreaStatus.EarlyTake;
                        if (!EarlierPickupFlag2)
                        {
                            networkmain.Client_SendEventMessage("655", "Station6QC2EarlyPickupDetected", "LotNumber", Station6ForOP2Scanboxid);
                            AllRJEvent.Info("655, Station6QC2EarlyPickupDetected,LotNumber," + Station6ForOP2Scanboxid);
                            EarlierPickupFlag2 = true;
                        }
                    }
                    else if ((PLCQueryRx6[PLCQueryRx_DM5100 + 66] == 0x01))
                    {
                        SafetyStatus2 = AreaStatus.MemNoClear;
                    }
                    else
                    {
                        SafetyStatus2 = AreaStatus.Null;
                    }
                    switch (Operator02State)
                    {
                    case WAITFORFINISHINGLABEL:    //wait for finishing label to be in ie. transition from "/0/0/0/0 .." to a


                        CheckStringClearFor6_OP2(OperatorB_PCtoPLCFinishingLabelOFFSET, Station6ForOP2Scanboxid);

                        if ((PLCQueryRx6[PLCQueryRx_DM5100 + 2] != 0x08) || (PLCWriteCommand6[PLCWriteCommand_DM5200 + 2] != 0x08))
                        {
                            break;
                        }
                        Array.Copy(PLCQueryRx6, 131, tmparray, 0, 10);
                        //convert array to string
                        Station6ForOP2Scanboxid = System.Text.Encoding.Default.GetString(tmparray);
                        Station6ForOP2Scanboxid.Trim();
                        RJButton2 = "";

                        //relfect finishing label data status to station 6 OP 1
                        if (Station6ForOP2Scanboxid != "\0\0\0\0\0\0\0\0\0\0")
                        {
                            // log6_1.Info("Operator 2 getting label from station 5 : " + Station6ForOP2Scanboxid);

                            networkmain.linePack.Info("Operator 2 getting label from station 5 : " + Station6ForOP2Scanboxid);
                            networkmain.stn6log = Station6ForOP2Scanboxid + " recieving";

                            //switch state
                            if (CheckStringUpdateFor6_OP2(OperatorB_PCtoPLCFinishingLabelOFFSET, Station6ForOP2Scanboxid))
                            {
                                Operator02State = DISPLAYVALIDLABELINFO;
                            }
                            else
                            {
                                byte[] tmpbyte = new byte[2];
                                tmpbyte = Encoding.ASCII.GetBytes("ER");
                                Array.Copy(tmpbyte, 0, PLCWriteCommand6, 155, 2);    //copy ER to PLC DM5267
                                Operator02State = INVALIDLABELHANDLE;
                            }
                        }
                        break;

                    case DISPLAYVALIDLABELINFO:                    //display valid label informations.,... this state may not be necessary...
                        ScannerStatus2 = BarcodeStatus.NotScanned; //reset scan information
                        //may not be necessary
                        //evnt_FindFinishingLabelForOperator.Set();//display finishing label information on user screen
                        st6finish2 = Station6ForOP2Scanboxid;    //display purposes only
                        networkmain.FindFinishingLabelForOperator2(Station6ForOP2Scanboxid);
                        st2POcount++;
                        POcount2++;
                        //display finishing label on user screen
                        PLCWriteCommand6[PLCWriteCommand_DM5204 + 2] = 0x02; //state 0x02 ready to scan
                        retrycounter    = 0;                                 //reset retry counter
                        Operator02State = VALIDLABELRUNSCANNER;
                        break;

                    case VALIDLABELRUNSCANNER:    //finishing label is valid, turn on scanner
                        try
                        {
                            Array.Copy(PLCQueryRx6, 131, tmparray, 0, 10);
                            //convert array to string
                            Station6ForOP2Scanboxid = System.Text.Encoding.Default.GetString(tmparray);
                            Station6ForOP2Scanboxid.Trim();

                            if ((Station6ForOP2Scanboxid == "\0\0\0\0\0\0\0\0\0\0") && (PLCQueryRx6[PLCQueryRx_DM5100 + 6] == 0x0))
                            {
                                Operator02State = ERHANDLER_STEP02;
                            }
                            Station06OOperator02ScannerConnect(networkmain);
                            Array.Copy(PLCQueryRx6, 131, tmparray, 0, 10);
                            //convert array to string
                            Station6ForOP2Scanboxid = System.Text.Encoding.Default.GetString(tmparray);
                            Station6ForOP2Scanboxid.Trim();
                            PLCWriteCommand6[PLCWriteCommand_DM5204 + 2] = 0x02;
                            if (retrycounter > X)    //exceed retry
                            {
                                Operator02State = SCANNUMBEREXCEEDHANDLE;
                            }
                            // log6_1.Info("Operator 2 Scanner FL read " + Station6ForOP2Scanboxid);
                            networkmain.linePack.Info("Operator 2 Scanner FL read " + Station6ForOP2Scanboxid);
                            networkmain.stn6log = Station6ForOP2Scanboxid + " OP2 Scanned";
                            int cnt = 0;
                            barcode = null;
                            while ((cnt < 100) && (barcode == null))
                            {
                                try
                                {
                                    OP2CognexScanner.ReadTimeout = 100;
                                    barcode = OP2CognexScanner.ReadLine();
                                }
                                catch (Exception) { }
                                cnt++;
                            }
                            if (cnt > 100)
                            {
                                throw new TimeoutException();
                            }
                            if (evnt_RejForOperator2.WaitOne(0))
                            {
                                // set ER to PLC
                                // PLC return 0xF PC return 0xF ==> PLC go to 0x0, PC goto 0x0
                                // wait for Station6ForOP1Scanboxid == "\0\0\0\0\0\0\0\0\0\0"
                                // or reset by change state
                                //reject event recieved
                                Operator02State = ERHANDLER_STEP01;
                                byte[] tmpbyte = new byte[2];
                                tmpbyte = Encoding.ASCII.GetBytes("ER");
                                Array.Copy(tmpbyte, 0, PLCWriteCommand6, 155, 2);    //copy ER to PLC DM5267
                                //need to send ack to middleware
                                evnt_RejForOperator2.Reset();
                            }
                            if (barcode != null)
                            {
                                //check if barcode equal to incoming finihsing label
                                if (barcode.Contains(Station6ForOP2Scanboxid))    //eliminate additional character issues
                                {
                                    //if equal,operator reject or shutting down program, exit and update PLC
                                    PLCWriteCommand6[PLCWriteCommand_DM5204 + 2] = 0x08;
                                    ScannerStatus2  = BarcodeStatus.Equal;
                                    Operator02State = 99;
                                }
                                else
                                {
                                    //if not equal, number of retry is X number? if X number prompt display <--= dont exit..
                                    //go to read barcode again if not equal.
                                    if (PLCWriteCommand6[PLCWriteCommand_DM5204 + 2] != 0x08)
                                    {
                                        networkmain.linePack.Info("Operator 2 Scan Retry");
                                        PLCWriteCommand6[PLCWriteCommand_DM5204 + 2] = 0x0F;    //why is this removed??!
                                    }

                                    retrycounter++;
                                    ScannerStatus2 = BarcodeStatus.NotEqual;
                                    barcode        = null;
                                    Status1        = "not equal try again";
                                    // break;
                                    continue;
                                }
                            }
                        }
                        catch (TimeoutException)
                        {
                            if (PLCWriteCommand6[PLCWriteCommand_DM5204 + 2] != 0x08)
                            {
                                networkmain.linePack.Info("Operator 2 Scan Timeout");
                                PLCWriteCommand6[PLCWriteCommand_DM5204 + 2] = 0x0F;
                            }

                            //not scan
                            // log6_1.Info("Operator 2 Scanner Timeout set 0 PLCWriteCommand_DM5204 + 2 ==0 ---9");
                            networkmain.stn6log     = "OP2 Scanner Timeout";
                            networkmain.OperatorLog = "Stn.6 OP2 Timeout";
                            Status1        = "Timeout";
                            ScannerStatus2 = BarcodeStatus.Timeout;
                            barcode        = null;
                            evnt_RejForOperator2.Reset();
                            evnt_ScannerRetryForOperator2.Reset();
                            Operator02State = SCANNERTIMEOUTHANDLE;
                        }
                        catch (Exception)
                        {
                            if (PLCWriteCommand6[PLCWriteCommand_DM5204 + 2] != 0x08)
                            {
                                networkmain.linePack.Info("Operator 2 Scanner exception set 0 PLCWriteCommand_DM5204 ==0 ---9");
                                PLCWriteCommand6[PLCWriteCommand_DM5204 + 2] = 0x0F;
                            }
                            networkmain.stn6log = "OP2 exception";
                            //not scan
                            barcode        = null;
                            ScannerStatus2 = BarcodeStatus.ExceptionError;
                            Status1        = "Exception";
                            evnt_RejForOperator2.Reset();
                            evnt_ScannerRetryForOperator2.Reset();
                            Operator02State = SCANNERTIMEOUTHANDLE;
                        }
                        break;

                    case SCANNERTIMEOUTHANDLE:    //scan time out
                        // await technician reset or plurge from PLC by setting Er or reject on product
                        Array.Copy(PLCQueryRx6, 131, tmparray, 0, 10);
                        //convert array to string
                        Station6ForOP2Scanboxid = System.Text.Encoding.Default.GetString(tmparray);
                        Station6ForOP2Scanboxid.Trim();

                        if ((Station6ForOP2Scanboxid == "\0\0\0\0\0\0\0\0\0\0") && (PLCQueryRx6[PLCQueryRx_DM5100 + 6] == 0x0))
                        {
                            Operator02State = ERHANDLER_STEP02;
                        }
                        if (evnt_ScannerRetryForOperator2.WaitOne(0))
                        {
                            //change state to VALIDLABELRUNSCANNER, reset counter
                            Operator02State = VALIDLABELRUNSCANNER;
                            retrycounter    = 0;
                            evnt_ScannerRetryForOperator2.Reset();
                        }
                        if (evnt_RejForOperator2.WaitOne(0))
                        {
                            // set ER to PLC
                            // PLC return 0xF PC return 0xF ==> PLC go to 0x0, PC goto 0x0
                            // wait for Station6ForOP1Scanboxid == "\0\0\0\0\0\0\0\0\0\0"
                            // or reset by change state
                            //reject event recieved
                            Operator02State = ERHANDLER_STEP01;
                            byte[] tmpbyte = new byte[2];
                            tmpbyte = Encoding.ASCII.GetBytes("ER");
                            Array.Copy(tmpbyte, 0, PLCWriteCommand6, 155, 2);    //copy ER to PLC DM5267
                            //need to send ack to middleware
                            // networkmain.Client_sendFG01_FG02_MOVE(Station6ForOP2Scanboxid, "FG01_FG02_MOVE");//NEED TO CHECK 23102015
                            evnt_RejForOperator2.Reset();
                        }
                        break;

                    case ERHANDLER_STEP01:

                        Array.Copy(PLCQueryRx6, 131, tmparray, 0, 10);
                        //convert array to string
                        Station6ForOP2Scanboxid = System.Text.Encoding.Default.GetString(tmparray);
                        Station6ForOP2Scanboxid.Trim();

                        if ((Station6ForOP2Scanboxid == "\0\0\0\0\0\0\0\0\0\0") && (PLCQueryRx6[PLCQueryRx_DM5100 + 6] == 0x0))
                        {
                            Operator02State = ERHANDLER_STEP02;
                        }
                        if (PLCQueryRx6[PLCQueryRx_DM5100 + 6] == 0xF)
                        {
                            //
                            //scxan not matching 0xf...plc wait for instruction...
                            //5237... na.. er etc etc... if rx er.... clear fl
                            //chk 5202 for 0
                            //send messsage to micron server (TBD) 604
                            try{
                                string      RJCODE = "604";
                                XmlDocument doc    = new XmlDocument();
                                doc.Load(@"ConfigEvent.xml");
                                XmlNode node   = doc.SelectSingleNode(@"/EVENT/R" + RJCODE);
                                string  RJName = node.InnerText;
                                try                                                                     //OEE OPERATOR 1 MANUA REJECT
                                {
                                    XmlNode fltrackingroot = networkmain.FLTrackingdoc.DocumentElement; //this house the list of summarized xml details
                                    XmlNode selectednode   = fltrackingroot.SelectSingleNode("descendant::LABEL[ID='" + Station6ForOP2Scanboxid + "']");
                                    if (selectednode != null)
                                    {
                                        string OEEidOP2 = selectednode.SelectSingleNode("OEEid").InnerText;
                                        rq.UpdST6RJ(OEEidOP2, 6, RJCODE);
                                    }
                                }
                                catch (Exception ex)
                                {
                                    IGTOEELog.Info(ex.ToString());
                                }
                                networkmain.Client_SendEventMessage("58", RJName, "BOX_ID", Station6ForOP2Scanboxid);
                                //log6_1.Info("QC2 Operator RJ Event Send to Middleware " +"604,"+RJName+","+Station6ForOP2Scanboxid);
                                networkmain.linePack.Info("QC2 Operator RJ Event Send to Middleware " + "604," + RJName + "," + Station6ForOP2Scanboxid);
                                MyEventQ.AddQ("21;Station6SealedMBBRejectedAtStation6;LotNumber;" + Station6ForOP1Scanboxid + ";QcstationNumber;1;OpearatorName;"
                                              + UserName1);

                                AllRJEvent.Info("QC2 Operator RJ Event Send to Middleware " + "604," + RJName + "," + Station6ForOP2Scanboxid);
                            }
                            catch (Exception ex) {
                                networkmain.linePack.Info(ex);
                            }

                            evnt_RejectFinishingLabelForStation6_OP2.Set();

                            st2Rejectcount++;
                            PLCWriteCommand6[PLCWriteCommand_DM5200 + 6] = 0xF;
                            Operator02State = ERHANDLER_STEP02;
                        }
                        break;

                    case ERHANDLER_STEP02:
                        Array.Copy(PLCQueryRx6, 131, tmparray, 0, 10);
                        //convert array to string
                        Station6ForOP2Scanboxid = System.Text.Encoding.Default.GetString(tmparray);
                        Station6ForOP2Scanboxid.Trim();
                        //log6_1.Info("Operator 2 getting label from station 5 : " + Station6ForOP2Scanboxid);


                        networkmain.linePack.Info("Operator 2 getting label from station 5 : " + Station6ForOP2Scanboxid);
                        networkmain.stn6log = Station6ForOP2Scanboxid + " OP2 recieving";
                        //relfect finishing label data status to station 6 OP 1
                        if ((Station6ForOP2Scanboxid == "\0\0\0\0\0\0\0\0\0\0") && (PLCQueryRx6[PLCQueryRx_DM5100 + 6] == 0x0))
                        {
                            //CheckStringClearFor6
                            PLCWriteCommand6[PLCWriteCommand_DM5204 + 2] = 0X0;
                            PLCWriteCommand6[PLCWriteCommand_DM5200 + 6] = 0x0;    //DM202 reject status
                            PLCWriteCommand6[PLCWriteCommand_DM5204 + 6] = 0x0;    //DM206 tracking label status
                            Station6ForOP2Scanboxid        = "\0\0\0\0\0\0\0\0\0\0";
                            Station6ForOP2TrackingLabel    = "\0\0\0\0\0\0\0\0";
                            networkmain.operator2BoxNumber = "";
                            SealerNumberQC2 = "";
                            st6finish2      = "";
                            station6track2  = "";
                            Status1         = "";
                            CheckStringClearFor6_OP2(OperatorB_PCtoPLCFinishingLabelOFFSET, _Station6ForOP2Scanboxid);
                            Operator02State    = WAITFORFINISHINGLABEL;
                            EarlierPickupFlag2 = false;
                        }
                        break;

                    case ERHANDLER_STEP03:
                        break;

                    case SCANNUMBEREXCEEDHANDLE:    //scan exceed 3 x
                        // await technician reset or plurge from PLC by setting Er or reject on product
                        networkmain.stn6log = "OP2 Exceeded Scan Trys";
                        ScannerStatus2      = BarcodeStatus.AttemptOut;
                        Array.Copy(PLCQueryRx6, 131, tmparray, 0, 10);
                        //convert array to string
                        Station6ForOP2Scanboxid = System.Text.Encoding.Default.GetString(tmparray);
                        Station6ForOP2Scanboxid.Trim();

                        if ((Station6ForOP2Scanboxid == "\0\0\0\0\0\0\0\0\0\0") && (PLCQueryRx6[PLCQueryRx_DM5100 + 6] == 0x0))
                        {
                            Operator02State = ERHANDLER_STEP02;
                        }
                        if (evnt_ScannerRetryForOperator2.WaitOne(0))
                        {
                            //change state to VALIDLABELRUNSCANNER, reset counter
                            Operator02State = VALIDLABELRUNSCANNER;
                            retrycounter    = 0;
                            evnt_ScannerRetryForOperator2.Reset();
                        }
                        if (evnt_RejForOperator2.WaitOne(0))
                        {
                            // set ER to PLC
                            // PLC return 0xF PC return 0xF ==> PLC go to 0x0, PC goto 0x0
                            // wait for Station6ForOP1Scanboxid == "\0\0\0\0\0\0\0\0\0\0"
                            // or reset by change state
                            //reject event recieved
                            Operator02State = ERHANDLER_STEP01;
                            byte[] tmpbyte = new byte[2];
                            tmpbyte = Encoding.ASCII.GetBytes("ER");
                            Array.Copy(tmpbyte, 0, PLCWriteCommand6, 155, 2);    //copy ER to PLC DM5237
                            //need to send ack to middleware
                            // networkmain.Client_sendFG01_FG02_MOVE(Station6ForOP2Scanboxid, "FG01_FG02_MOVE"); //NEED TO CHECK 23102015
                            evnt_RejForOperator2.Reset();
                        }
                        break;

                    case SCANMATCHWAITTRACKINGLABEL:    //scan matched, waiting for tracking label or wait for reject
                        if (PLCQueryRx6[PLCQueryRx_DM5100 + 6] == 0xF)
                        {
                            Operator02State = ERHANDLER_STEP01;
                            break;
                        }


                        if (PLCQueryRx6[PLCQueryRx_DM5100 + 6] == 0x9) //change here
                        {
                            Operator02State = SPECLABELPROCESS;
                            break;
                        }

                        Array.Copy(PLCQueryRx6, 131, tmparray, 0, 10);
                        //convert array to string
                        Station6ForOP2Scanboxid = System.Text.Encoding.Default.GetString(tmparray);
                        Station6ForOP2Scanboxid.Trim();

                        if ((Station6ForOP2Scanboxid == "\0\0\0\0\0\0\0\0\0\0") && (PLCQueryRx6[PLCQueryRx_DM5100 + 6] == 0x0))
                        {
                            Operator02State = ERHANDLER_STEP02;
                        }
                        byte[] tmparray1 = new byte[8];
                        //DM5020 TrackingLabel Update
                        Array.Copy(PLCQueryRx6, 71, tmparray1, 0, 8);
                        //convert array to string
                        Station6ForOP2TrackingLabel = System.Text.Encoding.Default.GetString(tmparray1);
                        #region New28042016
                        if ((PLCQueryRx6[PLCQueryRx_DM5100 + 14] == 0x08 && Station6ForOP2TrackingLabel != "\0\0\0\0\0\0\0\0") && PLCWriteCommand6[PLCWriteCommand_DM5204 + 6] != 99)     //added by GY 28/4/2016
                        {
                            byte[] str1 = barcodechangeposition(tmparray1);
                            string st   = System.Text.Encoding.Default.GetString(str1);
                            station6track2 = st.Trim();
                            if (networkmain.CheckTrackingLabel(Station6ForOP2TrackingLabel))
                            {
                                MyEventQ.AddQ("649;Station6QC2TLValidationOK;LotNumber;" + Station6ForOP2Scanboxid + ";LicensePlateBarcode;" + station6track2 +
                                              ";QcstationNumber;2;OperatorName;" + UserName2);
                                networkmain.stn6log = station6track2 + " OP2 TL Validate OK";
                                PLCWriteCommand6[PLCWriteCommand_DM5204 + 6] = 99;
                                ScannerStatus2 = BarcodeStatus.Null;
                            }
                            else
                            {
                                MyEventQ.AddQ("650;Station6QC2TLValidationNG;LotNumber;" + Station6ForOP2Scanboxid + ";LicensePlateBarcode;" + station6track2 +
                                              ";QcstationNumber;2;OperatorName;" + UserName2);
                                networkmain.stn6log = station6track2 + " OP2 TL Validate NG";
                                PLCWriteCommand6[PLCWriteCommand_DM5204 + 6] = 0x0F;
                                ScannerStatus2 = BarcodeStatus.Duplicated;
                                continue;
                            }
                        }
                        else if (PLCQueryRx6[PLCQueryRx_DM5100 + 14] == 0x00)
                        {
                            PLCWriteCommand6[PLCWriteCommand_DM5204 + 6] = 0;
                        }

                        if ((PLCQueryRx6[PLCQueryRx_DM5100 + 14] == 99 && Station6ForOP2TrackingLabel != "\0\0\0\0\0\0\0\0"))     //added by GY 28/4/2016
                        {
                            if (networkmain.CheckTrackingLabel(Station6ForOP2TrackingLabel))
                            {
                                int cnt = 0;
                                while (!networkmain.UpdateTrackingLabel(Station6ForOP2Scanboxid,
                                                                        Station6ForOP2TrackingLabel) &&
                                       !bTerminate) //assume PLC data moved before server reply
                                {
                                    if (cnt > 10)
                                    {
                                        break;
                                    }
                                    Thread.Sleep(10);
                                    cnt++;
                                    //need to handle invalid tracking label
                                }
                                if (cnt > 10)
                                {
                                    break;
                                }



                                // log6_1.Info("Operator 2 match " + "," + Station6ForOP2Scanboxid + "," + station6track2);

                                networkmain.linePack.Info("Operator 2 match " + "," + Station6ForOP2Scanboxid + "," + station6track2);
                                MyEventQ.AddQ("651;Station6QC2TLBindOK;LotNumber;" + Station6ForOP2Scanboxid + ";LicensePlateBarcode;" + station6track2 + ";QcstationNumber;2;OperatorName;" + UserName2);
                                PLCWriteCommand6[PLCWriteCommand_DM5204 + 6] = 0x08;    // association completed
                                                                                        //--> how to go back 0x0?? if finishing label is /0/0 i can assume all data cleared
                                networkmain.stn6log = station6track2 + "+" + Station6ForOP2Scanboxid + " OP2 TL Bind OK";
                                ScannerStatus2      = BarcodeStatus.Null;
                                Operator02State     = WAITTRACKINGLABELCLEAR;//create a state to wait for tracking label to clear
                            }
                            else
                            {
                                MyEventQ.AddQ("652;Station6QC2TLBindNG;LotNumber;" + Station6ForOP1Scanboxid + ";LicensePlateBarcode;" + station6track1 +
                                              ";QcstationNumber;1;OperatorName;" + UserName1);
                                networkmain.stn6log = station6track2 + "+" + Station6ForOP2Scanboxid + " OP2 TL Bind NG";
                                PLCWriteCommand6[PLCWriteCommand_DM5204 + 4] = 0x0F;
                            }
                        }
                        #endregion
                        #region ObseleteCode
                        //if ((Station6ForOP2TrackingLabel != "\0\0\0\0\0\0\0\0"))//check for valid tracking label
                        //{
                        //    byte[] str1 = barcodechangeposition(tmparray1);
                        //    string st = System.Text.Encoding.Default.GetString(str1);
                        //    station6track2 = st.Trim();
                        //    // log6_1.Info("Operator 2 set tracking label " + station6track2);

                        //    networkmain.linePack.Info("Operator 2 set tracking label " + station6track2);
                        //    networkmain.stn6log = station6track2 + " OP2 Set Tracking Lbl";
                        //    if (networkmain.CheckTrackingLabel(Station6ForOP2TrackingLabel) == true)

                        //    {


                        //        int cnt = 0;
                        //        while (!networkmain.UpdateTrackingLabel(Station6ForOP2Scanboxid,
                        //            Station6ForOP2TrackingLabel) &&
                        //            !bTerminate)//assume PLC data moved before server reply
                        //        {
                        //            if (cnt > 10) break;
                        //            Thread.Sleep(10);
                        //            cnt++;
                        //            //need to handle invalid tracking label
                        //        }
                        //        if (cnt > 10) break;



                        //        // log6_1.Info("Operator 2 match " + "," + Station6ForOP2Scanboxid + "," + station6track2);

                        //        networkmain.linePack.Info("Operator 2 match " + "," + Station6ForOP2Scanboxid + "," + station6track2);
                        //        MyEventQ.AddQ("24;Station6SealedMBBAcceptedAtStation6;LotNumber;" + Station6ForOP2Scanboxid + ";LicensePlateBarcode;" + station6track2 + ";QcstationNumber;2;OperatorName;" + UserName2);
                        //        PLCWriteCommand6[PLCWriteCommand_DM5204 + 6] = 0x08;// association completed
                        //                                                            //--> how to go back 0x0?? if finishing label is /0/0 i can assume all data cleared
                        //        ScannerStatus2 = BarcodeStatus.Null;
                        //        Operator02State = WAITTRACKINGLABELCLEAR;//create a state to wait for tracking label to clear


                        //    }
                        //    else
                        //    {

                        //        // log6_1.Info("Operator 2 Same tracking label in the System " + station6track2);
                        //        networkmain.linePack.Info("Operator 2 Same tracking label in the System " + station6track2);
                        //        PLCWriteCommand6[PLCWriteCommand_DM5204 + 6] = 0x0F;
                        //        ScannerStatus2 = BarcodeStatus.Duplicated;
                        //        continue;
                        //    }



                        //}
                        //else
                        //{
                        //    PLCWriteCommand6[PLCWriteCommand_DM5204 + 6] = 0x00;
                        //    // Station6ForOP1TrackingLabel = "\0\0\0\0\0\0\0\0\0\0";
                        //    // log6_1.Info("Operator 2 waiting tracking label "+ Station6ForOP2Scanboxid);
                        //    networkmain.linePack.Info("Operator 2 waiting tracking label " + Station6ForOP2Scanboxid);
                        //    // need to check for operator reject signal from PLC
                        //}
                        #endregion
                        break;     //update here

                    case WAITTRACKINGLABELCLEAR:
                        //wait for tracking label and finishing label to clear zero??
                        byte[] tmparray2 = new byte[8];
                        //DM5020 TrackingLabel Update
                        Array.Copy(PLCQueryRx6, 71, tmparray2, 0, 8);
                        //convert array to string
                        Station6ForOP2TrackingLabel = System.Text.Encoding.Default.GetString(tmparray2);
                        Array.Copy(PLCQueryRx6, 131, tmparray, 0, 10);
                        //convert array to string
                        Station6ForOP2Scanboxid = System.Text.Encoding.Default.GetString(tmparray);
                        Station6ForOP2Scanboxid.Trim();
                        //  log6_1.Info("Operator 2 getting label from station 5 : " + Station6ForOP2Scanboxid);
                        // networkmain.stn6log = Station6ForOP2Scanboxid + " OP2 recieving";
                        //relfect finishing label data status to station 6 OP 1
                        if ((Station6ForOP2Scanboxid == "\0\0\0\0\0\0\0\0\0\0") &&
                            (Station6ForOP2TrackingLabel == "\0\0\0\0\0\0\0\0"))
                        {
                            //both id goes zero
                            //log6_1.Info("Operator 2 getting label from station 5 : " + Station6ForOP2Scanboxid);

                            networkmain.linePack.Info("Operator 2 getting label from station 5 : " + Station6ForOP2Scanboxid);
                            networkmain.stn6log = Station6ForOP2Scanboxid + " OP2 recieving";
                            // MyEventQ.AddQ("25;Station6SealedMBBArrivalAtQCStation;LotNumber;" + Station6ForOP2Scanboxid + ";QcstationNumber;2;");
                            PLCWriteCommand6[PLCWriteCommand_DM5204 + 2] = 0X0;
                            PLCWriteCommand6[PLCWriteCommand_DM5200 + 6] = 0x0;    //DM202 reject status
                            PLCWriteCommand6[PLCWriteCommand_DM5204 + 6] = 0x0;    //DM206 tracking label status
                            Station6ForOP2Scanboxid        = "\0\0\0\0\0\0\0\0\0\0";
                            networkmain.operator2BoxNumber = "";
                            Station6ForOP2TrackingLabel    = "\0\0\0\0\0\0\0\0";
                            SealerNumberQC2 = "";
                            st6finish2      = "";
                            station6track2  = "";
                            Status1         = "";
                            CheckStringClearFor6_OP2(OperatorB_PCtoPLCFinishingLabelOFFSET, _Station6ForOP2Scanboxid);
                            Operator02State = WAITFORFINISHINGLABEL;
                        }
                        break;

                    case TRACKINGLABELAVAILABLE:    //tracking label available
                        break;

                    case 99:    //reject recieved from PLC @ state AFTERSCANMATCHED
                        if (PLCQueryRx6[PLCQueryRx_DM5100 + 14] == 0x01)
                        {
                            //log6_1.Info("Operator 2 Scanner FL contain " + Station6ForOP2Scanboxid);
                            networkmain.linePack.Info("Operator 2 Scanner FL contain " + Station6ForOP2Scanboxid);
                            networkmain.stn6log = Station6ForOP2Scanboxid + " OP2 Boxed";
                            Status1             = "equal";

                            Operator02State = SCANMATCHWAITTRACKINGLABEL;
                        }
                        break;

                    case REJECTRXAFTERSCANMATCHED:    //reject recieved from PLC @ state AFTERSCANMATCHED
                        break;

                    case INVALIDLABELHANDLE:    //recieved an invalid finishing label @ state checkforvalidfinishinglabel
                        //wait for label to be 00
                        Operator02State = ERHANDLER_STEP01;
                        break;

                    case SPECLABELPROCESS:
                        //byte[] tmpbyteSP = new byte[2];
                        //tmpbyteSP = Encoding.ASCII.GetBytes("SP");
                        //Array.Copy(tmpbyteSP, 0, PLCWriteCommand6, 155, 2);//copy SP to PLC DM5267
                        // log6_1.Info("Station 6 Operator 1 SPECKTEK " + Station6ForOP2Scanboxid);
                        //need to send SMS to micron
                        try                                                                     //OEE OPERATOR 1 MANUA REJECT
                        {
                            XmlNode fltrackingroot = networkmain.FLTrackingdoc.DocumentElement; //this house the list of summarized xml details
                            XmlNode selectednode   = fltrackingroot.SelectSingleNode("descendant::LABEL[ID='" + Station6ForOP2Scanboxid + "']");
                            if (selectednode != null)
                            {
                                string OEEidOP2 = selectednode.SelectSingleNode("OEEid").InnerText;
                                rq.UpdST6RJ(OEEidOP2, 1, "0");
                            }
                        }
                        catch (Exception ex)
                        {
                            IGTOEELog.Info(ex.ToString());
                        }
                        networkmain.linePack.Info("Station 6 Operator 2 SPECTEK " + Station6ForOP2Scanboxid);
                        networkmain.stn6log = Station6ForOP2Scanboxid + " OP2 Speck";
                        // ScannerStatus2 = BarcodeStatus.Speck;
                        MyEventQ.AddQ("22;Station6SealedSpectekAcceptedAtStation6;LotNumber;" + Station6ForOP2Scanboxid + ";QcstationNumber;2;OpearatorName"
                                      + UserName2);
                        // networkmain.Client_sendFG01_FG02_MOVE1(Station6ForOP2Scanboxid, "FG01_FG02_MOVE");
                        networkmain.Client_sendFG01_FG02_MOVE(Station6ForOP2Scanboxid, "FG01_FG02_MOVE QC2 Spectek");
                        networkmain.Client_sendFG01_FG02_MOVE62(Station6ForOP2Scanboxid);   //need to open in real time
                        //NEED TO SEND ACK TO MIDDLEWARE

                        PLCWriteCommand6[PLCWriteCommand_DM5200 + 6] = 0x9;
                        Operator02State = ERHANDLER_STEP02;

                        break;
                    }
                }
                catch (Exception ex)
                {
                    log.Error(ex.ToString());
                }
            }//
        }