예제 #1
0
        public static void insertLog(LinkingLog log, string sqlConnection)
        {
            using (var connection = new SqlConnection(sqlConnection))
                using (var command = new SqlCommand("up_AddLinkingLog", connection)
                {
                    CommandType = CommandType.StoredProcedure
                })
                {
                    connection.Open();
                    command.Parameters.AddWithValue("@Customer_Id", log.pcb.customerID != null ? log.pcb.customerID.ToString() : "");
                    command.Parameters.AddWithValue("@Customer", log.pcb.customerText != null ? log.pcb.customerText : "");
                    command.Parameters.AddWithValue("@SerialNumber", log.palletSerial != null ? log.palletSerial : "");
                    command.Parameters.AddWithValue("@PalletId", log.palletSerial != null ? log.palletSerial.ToString() : "");
                    command.Parameters.AddWithValue("@Assembly_Id", log.pcb.assemblyID != null ? log.pcb.assemblyID : "");
                    command.Parameters.AddWithValue("@Assembly", log.pcb.number != null ? log.pcb.number : "");
                    command.Parameters.AddWithValue("@Wip_Id", log.pcb.wipID != null ? log.pcb.wipID.ToString() : "");
                    command.Parameters.AddWithValue("@PanelNumberPL", log.palletSerial != null ? log.palletSerial : ""); //repetido
                    command.Parameters.AddWithValue("@PanelSizePL", log.panelSizePL != null ? log.panelSizePL : "");
                    command.Parameters.AddWithValue("@PanelSizeMES", log.panelSizeMES != null ? log.panelSizeMES : "");
                    command.Parameters.AddWithValue("@LinkObject", log.linkObject != null ? log.linkObject : "");
                    command.Parameters.AddWithValue("@LinkMaterialID", log.linkMaterialID != null ? log.linkMaterialID : "");
                    command.Parameters.AddWithValue("@EquipmentValue", log.equipmentValue != null ? log.equipmentValue : "");
                    command.Parameters.AddWithValue("@EquipmentName", log.equipmentName != null ? log.equipmentName : "");
                    command.Parameters.AddWithValue("@RouteStepID", log.routeStepID != null ? log.routeStepID : "");
                    command.Parameters.AddWithValue("@SerialLoops", log.serialLoops != null ? log.serialLoops : "");
                    command.Parameters.AddWithValue("@LoopsAllowed", log.loopsAllowed != null ? log.loopsAllowed : "");
                    command.Parameters.AddWithValue("@Message", log.message != null ? log.message : "");

                    command.ExecuteNonQuery();
                }
        }
예제 #2
0
        private LinkingLog prepareLog(PCB pcb, DataSet logData)
        {
            LinkingLog log = new LinkingLog();

            log.pcb          = pcb;
            log.palletID     = palletID;
            log.palletSerial = palletSerial;
            if (logData != null && logData.Tables[0].Rows.Count > 0)
            {
                log.loopsAllowed = logData.Tables[0].Rows[0]["LoopsAllowed"].ToString();
            }
            return(log);
        }
예제 #3
0
        /// <summary>
        /// Method that receives the request by POST with a JSON object as parameter
        /// Responsible for linking the PCB serial number with the pallet.
        /// Date: 09-25-2018
        /// Author: Luis Rodolfo Cabada Gamillo
        /// </summary>
        /// <param name="dataJSON"></param>
        /// <returns>HttpResponseMessage response</returns>
        /// POST api/pallet
        public HttpResponseMessage Post([FromBody] JObject dataJSON)
        {
            try
            {
                //Variables
                wsMes.Service wsMes                        = new wsMes.Service();
                string        pcbSerialNumber              = null;
                JToken        token                        = null;
                Encryption    encryption                   = new Encryption();
                Dictionary <string, string> historyInfo    = new Dictionary <string, string>();
                Dictionary <int, string>    unitsInPanel   = new Dictionary <int, string>();
                Dictionary <int, PCB>       unitsInPanelOK = new Dictionary <int, PCB>();
                initialConfig = new Dictionary <string, string>();
                var     response        = Request.CreateResponse(HttpStatusCode.OK);
                PCB     pcb             = new PCB();
                DataSet dsLocalAssembly = new DataSet();
                DataSet dsListByBoard   = new DataSet();
                sqlConnectionPL = "Data Source=" + encryption.DecryptString(sqlServerPL) + ";Integrated Security=SSPI; Initial Catalog=" +
                                  encryption.DecryptString(sqlDatabasePL) + ";";
                sqlConnectionMICT = "Data Source=" + encryption.DecryptString(sqlServerMICT) + ";Integrated Security=SSPI; Initial Catalog=" +
                                    encryption.DecryptString(sqlDatabaseMICT) + ";";
                LinkingLog log = new LinkingLog();
                string     validateSerialNumberResult;


                //////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
                token           = dataJSON;
                pcbSerialNumber = formatPCBSerial((string)token.SelectToken("pcbSerial"));
                plCustomerID    = (string)token.SelectToken("customerID");
                palletID        = (string)token.SelectToken("palletID");
                palletSerial    = (string)token.SelectToken("palletSerial");
                autoBreakPanel  = (bool)token.SelectToken("autoBreakPanel");
                machineName     = (string)token.SelectToken("machineName");
                userName        = (string)token.SelectToken("userName");

                palletLinkConfig = PCBQueryService.getPalletLinkConfigByMachine(machineName, sqlConnectionPL);

                if (palletLinkConfig.Tables[0].Rows.Count < 1)
                {
                    response.Content = new StringContent(getJSONResultPCB("Error PalletLink Config", pcb), Encoding.UTF8, "application/json");
                    return(response);
                }

                //Agregar todos estos datos a un dictionario para no traerlos todos por separado Ejemplo InitialConfig.
                initialConfig.Add("Customer", palletLinkConfig.Tables[0].Rows[0]["Customer"].ToString());
                initialConfig.Add("MesEquipment", palletLinkConfig.Tables[0].Rows[0]["MesEquipment"].ToString());
                initialConfig.Add("RouteStep", palletLinkConfig.Tables[0].Rows[0]["RouteStep"].ToString());
                initialConfig.Add("LinkObject", palletLinkConfig.Tables[0].Rows[0]["LinkObject"].ToString());
                initialConfig.Add("Process", palletLinkConfig.Tables[0].Rows[0]["Process"].ToString());
                initialConfig.Add("machineName", machineName);
                initialConfig.Add("palletID", palletID);
                initialConfig.Add("palletSerial", palletSerial);
                initialConfig.Add("customerID", plCustomerID);
                initialConfig.Add("userName", userName);
                initialConfig.Add("washingCycles", (string)token.SelectToken("washingCycles"));
                initialConfig.Add("limitWashingCycles", (string)token.SelectToken("limitWashingCycles"));
                initialConfig.Add("maintenanceCycles", (string)token.SelectToken("maintenanceCycles"));
                initialConfig.Add("limitMaintenance", (string)token.SelectToken("limitMaintenance"));

                //Obtains information of the serial number in MES
                historyInfo = PCBQueryService.getHistoryinfo(pcbSerialNumber);
                if (historyInfo == null)
                {
                    response.Content = new StringContent(getJSONResultPCB("Does not exist in MES", pcb), Encoding.UTF8, "application/json");
                    return(response);
                }

                //Obtains the values from dictionary historyInfo to reuse across the code
                pcb.wipID        = Int32.Parse(historyInfo["WIP_ID"]);
                pcb.customerID   = Int32.Parse(historyInfo["Customer_ID"]);
                pcb.customerText = historyInfo["CustomerText"];
                pcb.assembly     = historyInfo["Assembly"];
                pcb.number       = historyInfo["Number"];
                pcb.revision     = historyInfo["Revision"];
                pcb.assemblyID   = historyInfo["Assembly_ID"];

                //Obtain the pallet timeout by customer
                getPalletTimeOut(pcb);

                //Obtains the information from Pallet Link database
                dsLocalAssembly = PCBQueryService.checkIfAssyLocallyExistsUpd(pcb.number, Int32.Parse(plCustomerID), palletSerial, sqlConnectionPL);

                if (dsLocalAssembly.Tables[0].Rows.Count == 0)
                {
                    log = prepareLog(pcb, null);
                    PCBQueryService.insertLog(log, sqlConnectionPL);
                    log.message      = getJSONResultPCB("Error assambly configuration", pcb);
                    response.Content = new StringContent(log.message, Encoding.UTF8, "application/json");
                    return(response);
                }

                //-------A partir de este punto es posible saber si la tablilla viene en panel y dependiendo de esto se debe hacer un proceso u otro para
                //-------poder convivir con el MICT
                //Obtains information of the Panel from MES
                bool validatePanel = Boolean.Parse(dsLocalAssembly.Tables[0].Rows[0]["Panel"].ToString());
                dsListByBoard = wsMes.ListByBoard(pcb.wipID);


                if (!autoBreakPanel && validatePanel)
                {
                    foreach (DataRow dataRow in dsListByBoard.Tables[0].Rows)
                    {
                        unitsInPanel.Add(Int32.Parse(dataRow["Mapping"].ToString()), dataRow["SerialNumber"].ToString());
                    }
                }
                else
                {
                    unitsInPanel.Add(1, pcbSerialNumber);
                }

                //Validates the serial numbers
                foreach (int key in unitsInPanel.Keys)
                {
                    //Obtains history information from MES
                    string snToValidate = unitsInPanel[key].ToString();
                    historyInfo      = PCBQueryService.getHistoryinfo(snToValidate);
                    pcb              = new PCB();
                    pcb.wipID        = Int32.Parse(historyInfo["WIP_ID"]);
                    pcb.customerID   = Int32.Parse(historyInfo["Customer_ID"]);
                    pcb.customerText = historyInfo["CustomerText"];
                    pcb.assembly     = historyInfo["Assembly"];
                    pcb.number       = historyInfo["Number"];
                    pcb.revision     = historyInfo["Revision"];
                    pcb.assemblyID   = historyInfo["Assembly_ID"];
                    pcb.serialNumber = snToValidate;

                    validateSerialNumberResult = validateSerialNumber(snToValidate, pcb, dsLocalAssembly);

                    if (!"OK".Equals(validateSerialNumberResult))
                    {
                        response.Content = new StringContent(validateSerialNumberResult, Encoding.UTF8, "application/json");
                        return(response);
                    }

                    unitsInPanelOK.Add(key, pcb);
                }

                string resultLinkingProcess = linkingProcess(unitsInPanelOK);

                if (!"OK".Equals(resultLinkingProcess))
                {
                    response.Content = new StringContent(resultLinkingProcess, Encoding.UTF8, "application/json");
                    return(response);
                }

                response.Content = new StringContent(getFinalResult(pcb, unitsInPanelOK), Encoding.UTF8, "application/json");
                return(response);
            }
            catch (Exception ex)
            {
                var response = Request.CreateResponse(HttpStatusCode.OK);
                response.Content = new StringContent(getJSONResultPCB(ex.Message, null), Encoding.UTF8, "application/json");
                return(response);
            }
        }
예제 #4
0
        private string linkingProcess(Dictionary <int, PCB> unitsInPanelOK)
        {
            wsMesTis.MES_TIS wsMesTis        = new wsMesTis.MES_TIS();
            wsMes.Service    wsMes           = new wsMes.Service();
            DataTable        dtGetMaterialID = new DataTable();
            LinkingLog       log             = new LinkingLog();
            int    linkMaterialID;
            bool   linkOK = false;
            string result = null;

            foreach (KeyValuePair <int, PCB> element in unitsInPanelOK)
            {
                dtGetMaterialID = wsMes.GetMaterialID(Int32.Parse(element.Value.assemblyID), "");

                if (dtGetMaterialID.Rows.Count <= 0)
                {
                    log         = prepareLog(element.Value, null);
                    log.message = getJSONResultPCB("No linking material", element.Value);
                    PCBQueryService.insertLog(log, sqlConnectionPL);
                    return(log.message);
                }

                DataTable dtMaterialID = new DataTable();
                DataRow[] drMaterialID;

                drMaterialID = dtGetMaterialID.Select("LinkObject = '" + initialConfig["LinkObject"] + "'");
                dtMaterialID = drMaterialID.CopyToDataTable();

                linkMaterialID = Int32.Parse(dtMaterialID.Rows[0]["LinkMaterial_ID"].ToString());

                //linkOK = wsMes.EPS_LinkNonUniqueComponent(element.Value.customerID, element.Value.wipID, linkMaterialID, initialConfig["palletSerial"], 1, 1);

                //if (!linkOK)
                //{
                //    log = prepareLog(element.Value, null);
                //    log.message = getJSONResultPCB("No linking possible", element.Value);
                //    PCBQueryService.insertLog(log, sqlConnectionPL);
                //    return log.message;
                //}

                string sMES = "S" + element.Value.serialNumber + Environment.NewLine +
                              "C" + initialConfig["Customer"] + Environment.NewLine +
                              "I" + element.Value.customerText + Environment.NewLine +
                              "N" + initialConfig["MesEquipment"] + Environment.NewLine +
                              "P" + initialConfig["RouteStep"] + Environment.NewLine +
                              "O" + Environment.NewLine +
                              "p12" + Environment.NewLine +
                              "L" + Environment.NewLine +
                              "n" + element.Value.number + Environment.NewLine +
                              "r" + element.Value.revision + Environment.NewLine +
                              "TP" + Environment.NewLine +
                              "[" + DateTime.Now.AddSeconds(3).ToString("MM/dd/yyyy HH:mm:ss.fff") + Environment.NewLine +
                              "]" + DateTime.Now.AddSeconds(4).ToString("MM/dd/yyyy HH:mm:ss.fff") + Environment.NewLine;

                //resultProcessTestData = wsMesTis.ProcessTestData(sMES, "Generic");

                //if (!"PASS".Equals(resultProcessTestData.ToUpper()))
                //{
                //    log = prepareLog(element.Value, null);
                //    log.message = getJSONResultPCB("Error MES step", element.Value);
                //    PCBQueryService.insertLog(log, sqlConnectionPL);
                //    return log.message;
                //}

                //Registers the link in the local database.
                result = PCBQueryService.registerLink(element.Value, initialConfig, sqlConnectionPL);

                if (!"OK".Equals(result))
                {
                    log         = prepareLog(element.Value, null);
                    log.message = result;
                    PCBQueryService.insertLog(log, sqlConnectionPL);
                    return(log.message);
                }
            }

            //Finish the link
            PCBQueryService.updateCounter(initialConfig, sqlConnectionPL);
            updatePalletTimeOut();

            return("OK");
        }
예제 #5
0
        private string validateSerialNumber(string serialNumberToValidate, PCB pcb, DataSet dsLocalAssembly)
        {
            wsMes.Service wsMes                  = new wsMes.Service();
            int           rows                   = Int32.Parse(dsLocalAssembly.Tables[0].Rows[0]["Rows"].ToString());
            int           columns                = Int32.Parse(dsLocalAssembly.Tables[0].Rows[0]["Columns"].ToString());
            int           panelTotal             = rows * columns;
            bool          validPanel             = Boolean.Parse(dsLocalAssembly.Tables[0].Rows[0]["Panel"].ToString());
            bool          checkPointVerification = Boolean.Parse(dsLocalAssembly.Tables[0].Rows[0]["CheckPointValidation"].ToString());
            bool          checkLoops             = Boolean.Parse(dsLocalAssembly.Tables[0].Rows[0]["LoopValidation"].ToString());
            int           loopsNumber            = Int32.Parse(dsLocalAssembly.Tables[0].Rows[0]["LoopsAllowed"].ToString());
            int           palletPieces           = Int32.Parse(dsLocalAssembly.Tables[0].Rows[0]["Pieces"].ToString());

            //Checks if the piece is on Hold
            if (wsMes.BoardInHold(pcb.wipID))
            {
                LinkingLog log = new LinkingLog();
                log         = prepareLog(pcb, dsLocalAssembly);
                log.message = getJSONResultPCB("Piece on hold", pcb);
                PCBQueryService.insertLog(log, sqlConnectionPL);
                return(log.message);
            }

            //Checks MES checkpoint
            if (checkPointVerification)
            {
                DataSet dsCheckPoint = new DataSet();
                dsCheckPoint = wsMes.GetCheckPoint(serialNumberToValidate, "0", pcb.customerID, Int32.Parse(pcb.assemblyID));
                if (dsCheckPoint.Tables[0].Rows.Count > 0)
                {
                    LinkingLog log = new LinkingLog();
                    string     message;
                    string     errorCheckpoint = "Error checkpoint, ";
                    for (int i = 0; i < dsCheckPoint.Tables[0].Rows.Count; i++)
                    {
                        errorCheckpoint = errorCheckpoint + dsCheckPoint.Tables[0].Rows[i]["DescrText"].ToString() + ", ";
                    }
                    JObject json = new JObject();
                    message = "The following MES required processes are missing for the piece: "
                              + errorCheckpoint + " Please contact to Quality department to continue. Remove the unit from the pallet and press OK button to continue.";
                    json.Add("Result", message);
                    log         = prepareLog(pcb, dsLocalAssembly);
                    log.message = json.ToString();
                    PCBQueryService.insertLog(log, sqlConnectionPL);

                    return(log.message);
                }
            }

            if (checkLoops)
            {
                List <int> loopCustomers = PCBQueryService.getConfigurationByDescription("Loops Validation by Customer", sqlConnectionMICT).Split(',')
                                           .Select(Int32.Parse).ToList();

                int boardLoops = PCBQueryService.checkBoardCounterValidation(serialNumberToValidate, loopsNumber, pcb, loopCustomers, sqlConnectionPL);

                if (boardLoops > 0)
                {
                    LinkingLog log = new LinkingLog();
                    log = prepareLog(pcb, dsLocalAssembly);

                    if (loopCustomers != null)
                    {
                        foreach (int element in loopCustomers)
                        {
                            if (element.Equals(pcb.customerID))
                            {
                                log.message = getJSONResultPCB("Loops without Hold", pcb);
                                PCBQueryService.insertLog(log, sqlConnectionPL);
                                return(log.message);
                            }
                        }
                    }
                    log.message = getJSONResultPCB("Loops with Hold", pcb);
                    PCBQueryService.insertLog(log, sqlConnectionPL);
                    return(log.message);
                }
            }

            return("OK");
        }