예제 #1
0
        //void UpdateConduitExistsStatus()
        //{
        //    bool outputCell2IsConnected = RequireOutputs.IsConnected(this.OutputCell2, this.ConduitType);
        //    StatusItem outputConduit2Status;

        //    var buildingStatus = Db.Get().BuildingStatusItems;
        //    switch (this.ConduitType)
        //    {
        //        case ConduitType.Gas:
        //            outputConduit2Status = buildingStatus.NeedGasOut;
        //            break;
        //        case ConduitType.Liquid:
        //            outputConduit2Status = buildingStatus.NeedLiquidOut;
        //            break;
        //        case ConduitType.Solid:
        //            outputConduit2Status = buildingStatus.NeedSolidOut;
        //            break;
        //        default:
        //            throw new ArgumentOutOfRangeException();
        //    }

        //    bool outputConduit2StatusIsEmpty = (this.OutputConduit2StatusGuid != Guid.Empty);
        //    if (outputCell2IsConnected != outputConduit2StatusIsEmpty)
        //        return;

        //    this.OutputConduit2StatusGuid = this.Selectable.ToggleStatusItem(outputConduit2Status, this.OutputConduit2StatusGuid, !outputCell2IsConnected);
        //}

        void UpdateConduitBlockedStatus()
        {
            bool outputConduit2IsEmpty = FlowMgr.IsConduitEmpty(this.OutputCell2);
            bool blockageDetected      = (this.ConduitBlockedStatusItemGuid != Guid.Empty);

            if (outputConduit2IsEmpty != blockageDetected)
            {
                return;
            }

            StatusItem blockedMultiples = Db.Get().BuildingStatusItems.ConduitBlockedMultiples;

            this.ConduitBlockedStatusItemGuid = this.Selectable.ToggleStatusItem(blockedMultiples, this.ConduitBlockedStatusItemGuid, !outputConduit2IsEmpty);
        }
예제 #2
0
        void OnConduitUpdate(float data)
        {
            try
            {
                bool setActive = false;
                this.UpdateConduitBlockedStatus();

                if (this.Operation.IsOperational)
                {
                    var inputContent = FlowMgr.GetContents(InputCell);
                    if ((inputContent.mass > 0) && (inputContent.element != SimHashes.Vacuum))
                    {
                        var filterData    = this;
                        int outputCellIdx = filterData.GetOutputRouteIdx(inputContent.temperature, this.OutputCell1, this.OutputCell2);

                        if (FlowMgr.IsConduitEmpty(outputCellIdx))
                        {
                            var outputContent = FlowMgr.GetContents(outputCellIdx);

                            /// ConduitFlow.AddElement() included these (similar) chks:
                            ///     (outputContent.mass >= this.ConduitMassMax)
                            ///     (!inputContent.element.Equals(outputContent.element))
                            ///

                            float elementMoved = FlowMgr.AddElement(outputCellIdx
                                                                    , inputContent.element, inputContent.mass, inputContent.temperature, inputContent.diseaseIdx, inputContent.diseaseCount);

                            if (elementMoved > 0)
                            {
                                FlowMgr.RemoveElement(this.InputCell, elementMoved);
                            }
                        }
                        //else
                        //{
                        //    /// partial transfer not catered in (core) ElementFilter.OnConduitTick, don't break core design.
                        //}
                    }
                }

                this.Operation.SetActive(setActive, false);
            }
            catch (Exception ex)
            {
                KelmenUtils.Log("TemperatureFilterProcess.OnConduitUpdate", ex);
                throw ex;
            }
        }