예제 #1
0
        /// <summary>
        /// Implements the FailuresProcessing event
        /// </summary>
        /// <param name="sender"></param>
        /// <param name="e"></param>
        private void FailuresProcessing(object sender, Autodesk.Revit.DB.Events.FailuresProcessingEventArgs e)
        {
            FailuresAccessor failuresAccessor = e.GetFailuresAccessor();
            //failuresAccessor
            String transactionName = failuresAccessor.GetTransactionName();

            IList <FailureMessageAccessor> fmas = failuresAccessor.GetFailureMessages();

            if (fmas.Count == 0)
            {
                e.SetProcessingResult(FailureProcessingResult.Continue);
                return;
            }

            if (transactionName.Equals("Error_FailuresProcessingEvent"))
            {
                foreach (FailureMessageAccessor fma in fmas)
                {
                    FailureDefinitionId id = fma.GetFailureDefinitionId();
                    if (id == Command.m_idError)
                    {
                        failuresAccessor.ResolveFailure(fma);
                    }
                }

                e.SetProcessingResult(FailureProcessingResult.ProceedWithCommit);
                return;
            }

            e.SetProcessingResult(FailureProcessingResult.Continue);
        }
예제 #2
0
        /// <summary>
        /// Implements the FailuresProcessing event
        /// </summary>
        /// <param name="sender"></param>
        /// <param name="e"></param>
        private void FailuresProcessing(object sender, Autodesk.Revit.DB.Events.FailuresProcessingEventArgs e)
        {
            FailuresAccessor failuresAccessor = e.GetFailuresAccessor();
            //failuresAccessor
            String transactionName = failuresAccessor.GetTransactionName();

            IList <FailureMessageAccessor> failures = failuresAccessor.GetFailureMessages();

            if (failures.Count != 0)
            {
                foreach (FailureMessageAccessor f in failures)
                {
                    FailureDefinitionId id = f.GetFailureDefinitionId();

                    if (id == BuiltInFailures.JoinElementsFailures.CannotJoinElementsError)
                    {
                        // only default option being choosen,  not good enough!
                        //failuresAccessor.DeleteWarning(f);
                        failuresAccessor.ResolveFailure(f);
                        //failuresAccessor.
                        e.SetProcessingResult(FailureProcessingResult.ProceedWithCommit);
                    }

                    return;
                }
            }
        }
        private void ControlledApplication_FailuresProcessing(object sender, Autodesk.Revit.DB.Events.FailuresProcessingEventArgs e)
        {
            var failList = e.GetFailuresAccessor().GetFailureMessages();

            if (failList.Any())
            {
                e.GetFailuresAccessor().DeleteAllWarnings();
                e.SetProcessingResult(FailureProcessingResult.Continue);
            }
        }
예제 #4
0
        private void Application_FailuresProcessing(object sender, Autodesk.Revit.DB.Events.FailuresProcessingEventArgs e)
        {
            // Inside event handler, get all warnings
            var failList = e.GetFailuresAccessor().GetFailureMessages();

            if (failList.Any())
            {
                // skip all failures
                e.GetFailuresAccessor().DeleteAllWarnings();
                e.SetProcessingResult(FailureProcessingResult.Continue);
            }
        }
예제 #5
0
        void Application_FailuresProcessing(object sender, Autodesk.Revit.DB.Events.FailuresProcessingEventArgs e)
        //Errors handling
        {
            FailuresAccessor fa = e.GetFailuresAccessor();
            IList <FailureMessageAccessor> failList = new List <FailureMessageAccessor>();

            failList = fa.GetFailureMessages(); // Inside event handler, get all warnings
            foreach (FailureMessageAccessor failure in failList)
            {
                // check FailureDefinitionIds against ones that you want to dismiss, FailureDefinitionId failID = failure.GetFailureDefinitionId();
                // prevent Revit from showing Unenclosed room warnings
                FailureDefinitionId failID = failure.GetFailureDefinitionId();
                if (failID == BuiltInFailures.WorksharingFailures.DuplicateNamesChanged)
                {
                    fa.DeleteWarning(failure);
                }
            }
        }
예제 #6
0
        /***************************************************/
        /****           Private Event Handlers          ****/
        /***************************************************/

        private static void ControlledApplication_FailuresProcessing(object sender, Autodesk.Revit.DB.Events.FailuresProcessingEventArgs e)
        {
            bool             hasFailure       = false;
            FailuresAccessor failuresAccessor = e.GetFailuresAccessor();
            List <FailureMessageAccessor> failureMessageAccessorsList = failuresAccessor.GetFailureMessages().ToList();
            List <ElementId> elementsToDelete = new List <ElementId>();

            foreach (FailureMessageAccessor failureMessageAccessor in failureMessageAccessorsList)
            {
                try
                {
                    if (failureMessageAccessor.GetSeverity() == FailureSeverity.Warning)
                    {
                        failuresAccessor.DeleteWarning(failureMessageAccessor);
                        continue;
                    }
                    else
                    {
                        failuresAccessor.ResolveFailure(failureMessageAccessor);
                        hasFailure = true;
                        continue;
                    }
                }
                catch
                {
                }
            }

            if (elementsToDelete.Count != 0)
            {
                failuresAccessor.DeleteElements(elementsToDelete);
            }

            if (hasFailure)
            {
                e.SetProcessingResult(FailureProcessingResult.ProceedWithCommit);
            }

            e.SetProcessingResult(FailureProcessingResult.Continue);
        }
        private void Application_FailuresProcessing(object sender, Autodesk.Revit.DB.Events.FailuresProcessingEventArgs e)
        {
            // Inside event handler, get all warnings
            var failList = e.GetFailuresAccessor().GetFailureMessages();

            if (failList.Any())
            {
                _undeleted++;
                foreach (var failure in failList)
                {
                    // check FailureDefinitionIds against ones that you want to dismiss,
                    var failId = failure.GetFailureDefinitionId();

                    // prevent Revit from showing Unenclosed room warnings
                    if (failId == BuiltInFailures.EditingFailures.CannotEditDeletedElements)
                    {
                        e.GetFailuresAccessor().DeleteAllWarnings();
                    }
                }

                e.SetProcessingResult(FailureProcessingResult.ProceedWithRollBack);
            }
        }
예제 #8
0
        /// <summary>
        /// Обработчик предупреждений
        /// </summary>
        private static void Application_FailuresProcessing(
            object sender,
            Autodesk.Revit.DB.Events.FailuresProcessingEventArgs e)
        {
            var failureAccessor = e.GetFailuresAccessor();

            var failList = failureAccessor.GetFailureMessages();

            if (!failList.Any())
            {
                return;
            }

            if (failureAccessor.GetSeverity() == FailureSeverity.Warning)
            {
                failureAccessor.DeleteAllWarnings();
                e.SetProcessingResult(FailureProcessingResult.Continue);
            }

            e.SetProcessingResult(failureAccessor.GetSeverity() == FailureSeverity.Error
                ? FailureProcessingResult.ProceedWithCommit
                : FailureProcessingResult.ProceedWithRollBack);
        }
예제 #9
0
 public void Application_FailuresProcessing(object sender, Autodesk.Revit.DB.Events.FailuresProcessingEventArgs e)
 {
     ExecuteEventHooks(EventType.Application_FailuresProcessing, sender, e);
 }
        /// <summary>
        /// This is an event handler that responds to a failure according to the current settings
        /// </summary>
        /// <param name="sender">The sending object, i.e. the Revit application</param>
        /// <param name="e">The event arguments</param>
        public void AutoOptionsFailureHandler(Object sender, Autodesk.Revit.DB.Events.FailuresProcessingEventArgs e)
        {
            //don't process if handling is turned off
            if (currentSettings.HandlingActive == false)
            {
                return;
            }

            //update the uiApp reference
            Application RevitApp = sender as Application;

            uiApp = new UIApplication(RevitApp);

            FailuresAccessor fa = e.GetFailuresAccessor();
            //this is the action that will be taken to attempt resolution. Default is to continue the default Revit failure processing
            FailureProcessingResult action = FailureProcessingResult.Continue;

            foreach (FailureMessageAccessor fma in fa.GetFailureMessages())
            {
                AutoFailureHandlingOptions aFOpts = currentSettings.AllFailureOptions
                                                    .Where(x => x.FailureGuid == fma.GetFailureDefinitionId().Guid)
                                                    .FirstOrDefault();

                if (aFOpts != null)
                {
                    //Show the CatchFailures dialog if a failure was caught
                    if (currentSettings.InteractiveModeEnabled)
                    {
                        try
                        {
                            //todo: clone to allow roll-back?
                            FailureCatcherWindow failWin = new FailureCatcherWindow(currentSettings, aFOpts, uiApp);

                            Boolean?result = failWin.ShowDialog();

                            if (result.Value)
                            {
                                //Write changes to the .ini
                                currentSettings.LastUpdate = DateTime.Now;
                                IAutoOptionsRepository settingsRepo = new AutoOptionsConfigFileRepo();
                                settingsRepo.WriteAutoOptions(currentSettings);
                            }
                        }
                        catch (Exception ex)
                        {
                            TaskDialog.Show("ex", ex.Message + "\n" + ex.StackTrace);
                            throw;
                        }
                    }

                    FailureResolutionOption selectedResolution = aFOpts.SelectedResolution;
                    if (selectedResolution is AutoOptionsResolution)
                    {
                        try
                        {
                            switch (((AutoOptionsResolution)selectedResolution).Resolution)
                            {
                            case AutoOptionsResolutionType.NoAction:
                                break;

                            case AutoOptionsResolutionType.DeleteAffected:
                                fa.DeleteElements(fma.GetFailingElementIds().ToList());
                                action = FailureProcessingResult.ProceedWithCommit;
                                break;

                            case AutoOptionsResolutionType.CancelTransaction:
                                //todo: not working, being overwritten?
                                action = FailureProcessingResult.ProceedWithRollBack;
                                e.SetProcessingResult(action);
                                fa.RollBackPendingTransaction();
                                return;

                            case AutoOptionsResolutionType.HideWarning:
                                //todo: check if actually is a warning?
                                fa.DeleteWarning(fma);
                                break;

                            default:
                                break;
                            }
                        }
                        catch (Exception ex)
                        {
                            TaskDialog.Show("Dispatcher", ex.Message + "\n" + ex.Source + "\n" + ex.StackTrace);
                        }
                    }
                    else if (selectedResolution is RevitResolution)
                    {
                        try
                        {
                            FailureResolutionType fRT = ((RevitResolution)selectedResolution).Resolution;

                            if (fma.HasResolutionOfType(fRT))
                            {
                                fma.SetCurrentResolutionType(fRT);
                                fa.ResolveFailure(fma);
                                action = FailureProcessingResult.ProceedWithCommit;
                            }
                            else
                            {
                                TaskDialog.Show("AutoOptions", "The selected automatic resolution \n***" + aFOpts.SelectedResolution.FriendlyCaption + " (" + fRT + ")***\ncan't be used");
                            }
                        }
                        catch (Exception ex)
                        {
                            TaskDialog.Show("Dispatcher", ex.Message + "\n" + ex.Source + "\n" + ex.StackTrace);
                        }
                    }
                }
            }

            e.SetProcessingResult(action);
        }