/// <summary>
        /// This method should be called prior to using this class
        /// </summary>
        internal static CompletionCode Init()
        {
            CompletionCode completionCode = CompletionCode.CommDevFailedToInit;

            // populdate Blade_En State Cache.
            foreach (byte Id in physicalServerIdTable)
            {
                CachedBladePowerStatus.Add(Id, new BladeEnState());
            }

            // Clear this flag in case that CM retries to initialize
            isTerminating = false;

            // Enforce that the update to the flag variable is visible to other threads orderly
            Thread.MemoryBarrier();

            portManagers = new PortManager[numPorts];

            for (int i = 0; i < numPorts; i++)
            {
                portManagers[i] = new SerialPortManager(i, numPriorityLevels);
                completionCode = portManagers[i].Init();
                if (CompletionCodeChecker.Failed(completionCode) == true)
                {
                    Tracer.WriteError("Failed to initialize portManager: {0} Logical Id: {1}", i,
                        PortManager.GetPhysicalPortNameFromLogicalId(i));
                    Release();
                    return completionCode;
                }
            }

            return completionCode;
        }
コード例 #2
0
        /// <summary>
        /// This method should be called prior to using this class
        /// </summary>
        static internal CompletionCode Init()
        {
            CompletionCode completionCode = CompletionCode.CommDevFailedToInit;

            // Clear this flag in case that CM retries to initialize
            isTerminating = false;

            // Safe mode is disabled by default when initialized
            isSafeModeEnabled = false;

            // Enforce that the update to the flag variable is visible to other threads orderly
            Thread.MemoryBarrier();

            portManagers = new PortManager[numPorts];

            for (int i = 0; i < numPorts; i++)
            {
                portManagers[i] = new SerialPortManager(i, numPriorityLevels);
                completionCode = portManagers[i].Init();
                if (CompletionCodeChecker.Failed(completionCode) == true)
                {
                    Tracer.WriteError("Failed to initialize portManager: {0} Logical Id: {1}", i,
                        PortManager.GetPhysicalPortNameFromLogicalId(i));
                    Release();
                    return completionCode;
                }
            }

            return completionCode;
        }