        public DockingStationEvent Execute()
        {
            string funcMsg = Name + ".Execute";

            Log.Debug(funcMsg);

            // create return event
            InstrumentDisableReplacedEvent returnEvent = new InstrumentDisableReplacedEvent(this);

            returnEvent.DetectedReplacedSerialNumber = this.ReplacedSerialNumber;

            try
            {
                // record docking station and docked instrument on return event,
                // instrument serial number will be stored in the event journal
                returnEvent.DockingStation   = Configuration.DockingStation;
                returnEvent.DockedInstrument = (ISC.iNet.DS.DomainModel.Instrument)Master.Instance.SwitchService.Instrument.Clone();

                // check that the instrument is still docked
                if (!Controller.IsDocked())
                {
                    throw new InstrumentUndockedDuringDisableReplacedException();
                }

                // establish communication with the docked instrument, verify it has the expected
                // serial number, and then disable it
                using (IFactoryController factoryController = SwitchService.CreateFactoryInstrumentController())
                {
                    factoryController.InstrumentController.Initialize(InstrumentController.Mode.Batch);

                    returnEvent.SerialNumberBefore = factoryController.InstrumentController.GetSerialNumber();

                    // ensure the docked instrument serial number, the instrument serial number that will be saved to the event journal, and the detected
                    // replaced instrument serial number all match before continuing
                    if (returnEvent.SerialNumberBefore == this.ReplacedSerialNumber && returnEvent.DockedInstrument.SerialNumber == this.ReplacedSerialNumber)
                    {
                        Log.Warning(string.Format("DISABLING REPLACED INSTRUMENT: {0}", returnEvent.SerialNumberBefore));
                        factoryController.DisableReplacedInstrument();
                        Log.Warning(string.Format("INSTRUMENT DISABLED"));

                        // set flag on switch service to stop anything else from happening until the disabled instrument is undocked
                        Master.Instance.SwitchService.IsInstrumentReplaced = true;

                        returnEvent.Passed            = true;
                        returnEvent.SerialNumberAfter = factoryController.InstrumentController.GetSerialNumber();
                    }
                }
            }
            catch (InstrumentUndockedDuringDisableReplacedException)
            {
                throw;
            }
            catch (Exception ex)
            {
                Log.Error(string.Format("{0} - Caught Exception", funcMsg), ex);

                // check that the instrument is still docked
                if (!Master.Instance.SwitchService.IsDocked())
                {
                    throw new InstrumentUndockedDuringDisableReplacedException();
                }
            }
            finally
            {
                // log operation results
                Log.Debug(string.Format("WAS INSTRUMENT DISABLED: {0} - Detected Replaced S/N: {1} - S/N (before): {2} - S/N (after): {3}", returnEvent.Passed, returnEvent.DetectedReplacedSerialNumber, returnEvent.SerialNumberBefore, returnEvent.SerialNumberAfter));
            }

            return(returnEvent);
        }