コード例 #1
0
        override internal bool OnStatus(Status stat)
        {
            bool no_errors = base.OnStatus(stat);

            if (stat.HasBeenReset)
            {
                Active = false;
                monitor.Activation(false);
                // TODO is TimeSpan(0) the best for this notification?  Could calculate duration, but how much time between reset (deactivation) and now?
                ThermalProgress.Raise(this, new ThermalProgressArgs(_lastTemperature, new TimeSpan(0), ThermalState.Aborted));
                no_errors = false;
            }
            if (no_errors)
            {
                bool is_controlling = Controlling(stat);
#if DEBUG
                // Currently, transitioning state is not examined or used in public interface.
                // examine the controlling and transitioning status for consistency with assumptions behind this code
                bool is_transitioning = Transitioning(stat);
                //
                if (is_controlling && is_transitioning)
                {
                    logger.Debug("Heater {0} reports 'controlling' and 'transitioning' ({1:X})", Name, (byte)stat);
                }
#endif
                if (monitor.StatusUpdate(is_controlling))
                {
                    ThermalProgress.Raise(this, new ThermalProgressArgs(_lastTemperature, monitor.TimeActive, monitor.State));
                }
            }
            _last_status = stat;
            return(no_errors);
        }
コード例 #2
0
 public void Activate(int mode)
 {
     logger.Debug("E: {0} Activating: {1}", Name, mode.ToString());
     // command uses hardcoded "0" instead of DefaultChannel() -- activation always applies via
     // channel 0, even if the heater in question is a resistive on channel 1.
     // (see: ResistiveHeater.ActivationValue())
     Issue(iCmd(HActivate, "0", mode.ToString(),
                (ival) => // iVal is ignored in handler, assumes command successful
     {
         NActive = mode;
         if (monitor.Activation(true))
         {
             ThermalProgress.Raise(this, new ThermalProgressArgs(_lastTemperature, monitor.TimeActive, Controlling(_last_status), Transitioning(_last_status)));
         }
     }), true);
 }
コード例 #3
0
 public void Activate(bool active)
 {
     logger.Trace("E: {0} Activating: {1}", Name, active);
     // command uses hardcoded "0" instead of DefaultChannel() -- activation always applies via
     // channel 0, even if the heater in question is a resistive on channel 1.
     // (see: ResistiveHeater.ActivationValue())
     Issue(iCmd(HActivate, "0", ActivationValue(active),
                (ival) => // iVal is ignored in handler, assumes command successful
     {
         if (Active != active)
         {
             Active = active;
             if (monitor.Activation(active))
             {
                 ThermalProgress.Raise(this, new ThermalProgressArgs(_lastTemperature, monitor.TimeActive, monitor.State));
             }
         }
     }));
 }