コード例 #1
0
        /// <summary>
        /// 查询所有的墒情站点信息
        /// </summary>
        /// <returns></returns>
        public List <CEntitySoilStation> QueryAllSoilStation()
        {
            string         sql          = " select * from " + CT_TableName;
            SqlDataAdapter adapter      = new SqlDataAdapter(sql, CDBManager.GetInstacne().GetConnection());
            DataTable      dataTableTmp = new DataTable();

            adapter.Fill(dataTableTmp);
            // 构建结果集
            List <CEntitySoilStation> results = new List <CEntitySoilStation>();

            for (int rowid = 0; rowid < dataTableTmp.Rows.Count; ++rowid)
            {
                CEntitySoilStation soilStation = new CEntitySoilStation();
                soilStation.StationID   = dataTableTmp.Rows[rowid][CN_StationId].ToString();
                soilStation.SubCenterID = int.Parse(dataTableTmp.Rows[rowid][CN_SubCenterID].ToString());
                soilStation.StationName = dataTableTmp.Rows[rowid][CN_StationName].ToString();
                soilStation.StationType = CEnumHelper.DBStrToStationType(dataTableTmp.Rows[rowid][CN_StationType].ToString());


                //  soilStation.StrDeviceNumber = dataTableTmp.Rows[rowid][CN_DeviceNumber].ToString();


                soilStation.A10 = GetCellDecimalValue(dataTableTmp.Rows[rowid][CN_A10]);
                soilStation.B10 = GetCellDecimalValue(dataTableTmp.Rows[rowid][CN_B10]);
                soilStation.C10 = GetCellDecimalValue(dataTableTmp.Rows[rowid][CN_C10]);
                soilStation.D10 = GetCellDecimalValue(dataTableTmp.Rows[rowid][CN_D10]);
                soilStation.M10 = GetCellDecimalValue(dataTableTmp.Rows[rowid][CN_M10]);
                soilStation.N10 = GetCellDecimalValue(dataTableTmp.Rows[rowid][CN_N10]);

                soilStation.A20 = GetCellDecimalValue(dataTableTmp.Rows[rowid][CN_A20]);
                soilStation.B20 = GetCellDecimalValue(dataTableTmp.Rows[rowid][CN_B20]);
                soilStation.C20 = GetCellDecimalValue(dataTableTmp.Rows[rowid][CN_C20]);
                soilStation.D20 = GetCellDecimalValue(dataTableTmp.Rows[rowid][CN_D20]);
                soilStation.M20 = GetCellDecimalValue(dataTableTmp.Rows[rowid][CN_M20]);
                soilStation.N20 = GetCellDecimalValue(dataTableTmp.Rows[rowid][CN_N20]);

                soilStation.A30 = GetCellDecimalValue(dataTableTmp.Rows[rowid][CN_A30]);
                soilStation.B30 = GetCellDecimalValue(dataTableTmp.Rows[rowid][CN_B30]);
                soilStation.C30 = GetCellDecimalValue(dataTableTmp.Rows[rowid][CN_C30]);
                soilStation.D30 = GetCellDecimalValue(dataTableTmp.Rows[rowid][CN_D30]);
                soilStation.M30 = GetCellDecimalValue(dataTableTmp.Rows[rowid][CN_M30]);
                soilStation.N30 = GetCellDecimalValue(dataTableTmp.Rows[rowid][CN_N30]);

                soilStation.A40 = GetCellDecimalValue(dataTableTmp.Rows[rowid][CN_A40]);
                soilStation.B40 = GetCellDecimalValue(dataTableTmp.Rows[rowid][CN_B40]);
                soilStation.C40 = GetCellDecimalValue(dataTableTmp.Rows[rowid][CN_C40]);
                soilStation.D40 = GetCellDecimalValue(dataTableTmp.Rows[rowid][CN_D40]);
                soilStation.M40 = GetCellDecimalValue(dataTableTmp.Rows[rowid][CN_M40]);
                soilStation.N40 = GetCellDecimalValue(dataTableTmp.Rows[rowid][CN_N40]);

                soilStation.A60 = GetCellDecimalValue(dataTableTmp.Rows[rowid][CN_A60]);
                soilStation.B60 = GetCellDecimalValue(dataTableTmp.Rows[rowid][CN_B60]);
                soilStation.C60 = GetCellDecimalValue(dataTableTmp.Rows[rowid][CN_C60]);
                soilStation.D60 = GetCellDecimalValue(dataTableTmp.Rows[rowid][CN_D60]);
                soilStation.M60 = GetCellDecimalValue(dataTableTmp.Rows[rowid][CN_M60]);
                soilStation.N60 = GetCellDecimalValue(dataTableTmp.Rows[rowid][CN_N60]);

                soilStation.VoltageMin = GetCellDecimalValue(dataTableTmp.Rows[rowid][CN_Voltagemin]);

                soilStation.GSM               = dataTableTmp.Rows[rowid][CN_GSM].ToString();
                soilStation.GPRS              = dataTableTmp.Rows[rowid][CN_GPRS].ToString();
                soilStation.BDSatellite       = dataTableTmp.Rows[rowid][CN_BDSatellite].ToString();
                soilStation.BDMemberSatellite = dataTableTmp.Rows[rowid][CN_BDMember].ToString();

                soilStation.Maintran       = dataTableTmp.Rows[rowid][CN_Maintran].ToString();
                soilStation.Subtran        = dataTableTmp.Rows[rowid][CN_Subtran].ToString();
                soilStation.Datapotocol    = dataTableTmp.Rows[rowid][CN_Dataprotocol].ToString();
                soilStation.Reportinterval = dataTableTmp.Rows[rowid][CN_Reportinterval].ToString();
                results.Add(soilStation);
            }
            return(results);
        }
コード例 #2
0
ファイル: CSQLStation.cs プロジェクト: wwkkww1983/hydroSW
        public List <CEntityStation> QueryAll()
        {
            string         sql          = " select * from " + CT_TableName;
            SqlDataAdapter adapter      = new SqlDataAdapter(sql, CDBManager.GetInstacne().GetConnection());
            DataTable      dataTableTmp = new DataTable();

            adapter.Fill(dataTableTmp);
            // 构建结果集
            List <CEntityStation> results = new List <CEntityStation>();

            //dataTableTmp.Rows.Count
            for (int rowid = 0; rowid < dataTableTmp.Rows.Count; ++rowid)
            {
                CEntityStation station = new CEntityStation();
                station.StationID   = dataTableTmp.Rows[rowid][CN_StationID].ToString();
                station.SubCenterID = int.Parse(dataTableTmp.Rows[rowid][CN_SubCenterID].ToString());
                station.StationName = dataTableTmp.Rows[rowid][CN_StationName].ToString();
                station.StationType = CEnumHelper.DBStrToStationType(dataTableTmp.Rows[rowid][CN_StationType].ToString());
                if (!dataTableTmp.Rows[rowid][CN_WaterBase].ToString().Equals(""))
                {
                    station.DWaterBase = Decimal.Parse(dataTableTmp.Rows[rowid][CN_WaterBase].ToString());
                }
                if (!dataTableTmp.Rows[rowid][CN_WaterMax].ToString().Equals(""))
                {
                    station.DWaterMax = Decimal.Parse(dataTableTmp.Rows[rowid][CN_WaterMax].ToString());
                }
                if (!dataTableTmp.Rows[rowid][CN_WaterMin].ToString().Equals(""))
                {
                    station.DWaterMin = Decimal.Parse(dataTableTmp.Rows[rowid][CN_WaterMin].ToString());
                }
                if (!dataTableTmp.Rows[rowid][CN_WaterChange].ToString().Equals(""))
                {
                    station.DWaterChange = Decimal.Parse(dataTableTmp.Rows[rowid][CN_WaterChange].ToString());
                }
                if (!dataTableTmp.Rows[rowid][CN_RainAccuracy].ToString().Equals(""))
                {
                    station.DRainAccuracy = float.Parse(dataTableTmp.Rows[rowid][CN_RainAccuracy].ToString());
                }
                if (!dataTableTmp.Rows[rowid][CN_RainChange].ToString().Equals(""))
                {
                    station.DRainChange = Decimal.Parse(dataTableTmp.Rows[rowid][CN_RainChange].ToString());
                }
                if (!dataTableTmp.Rows[rowid][CN_VoltageMin].ToString().Equals(""))
                {
                    station.DVoltageMin = float.Parse(dataTableTmp.Rows[rowid][CN_VoltageMin].ToString());
                }

                station.GSM  = dataTableTmp.Rows[rowid][CN_GSM].ToString();
                station.GPRS = dataTableTmp.Rows[rowid][CN_GPRS].ToString();
                station.BDMemberSatellite = dataTableTmp.Rows[rowid][CN_BDMember].ToString();
                station.BDSatellite       = dataTableTmp.Rows[rowid][CN_BDSatellite].ToString();
                station.Maintran          = dataTableTmp.Rows[rowid][CN_Maintran].ToString();
                station.Subtran           = dataTableTmp.Rows[rowid][CN_Subtran].ToString();
                station.Datapotocol       = dataTableTmp.Rows[rowid][CN_Dataprotocol].ToString();
                station.Watersensor       = dataTableTmp.Rows[rowid][CN_Watersensor].ToString();
                station.Rainsensor        = dataTableTmp.Rows[rowid][CN_Rainsensor].ToString();
                station.Reportinterval    = dataTableTmp.Rows[rowid][CN_Reportinterval].ToString();
                results.Add(station);
            }
            return(results);
        }