public ISensorReading ReadSensor()
        {
            var result = new HumidityTemperatureAltitudePressureReading();

            using (_sensor)
            {
                _sensor.SetPowerMode(Bmx280PowerMode.Forced);

                //set samplings
                _sensor.SetTemperatureSampling(Sampling.UltraLowPower);
                _sensor.SetPressureSampling(Sampling.UltraLowPower);
                _sensor.SetHumiditySampling(Sampling.UltraLowPower);

                result.Humidity    = _sensor.ReadHumidityAsync().Result;
                result.Temperature = _sensor.ReadTemperatureAsync().Result;
                result.Altitude    = _sensor.ReadAltitudeAsync(defaultSeaLevelPressure).Result;
                result.Pressure    = _sensor.ReadPressureAsync().Result;
            }

            return(result);
        }
コード例 #2
0
ファイル: Program.cs プロジェクト: travswim/testrpi
        static async Task Main(string[] args)
        {
            // bus id on the raspberry pi 3
            const int busId = 1;

            // Setup i2C device (BME280)
            var i2cSettings = new I2cConnectionSettings(busId, Bme280.DefaultI2cAddress);
            var i2cDevice   = I2cDevice.Create(i2cSettings);
            var i2CBmpe80   = new Bme280(i2cDevice);


            using (i2CBmpe80)
            {
                while (true)
                {
                    // set mode forced so device sleeps after read
                    i2CBmpe80.SetPowerMode(Bmx280PowerMode.Forced);

                    // Get sampling accuracy
                    i2CBmpe80.SetHumiditySampling(Sampling.Standard);
                    i2CBmpe80.SetTemperatureSampling(Sampling.Standard);
                    i2CBmpe80.SetPressureSampling(Sampling.Standard);

                    // Get variables
                    Iot.Units.Temperature tempValue = await i2CBmpe80.ReadTemperatureAsync();

                    double humValue = await i2CBmpe80.ReadHumidityAsync();

                    double preValue = await i2CBmpe80.ReadPressureAsync();

                    // Print to screen
                    Console.WriteLine($"Weather at time: {DateTime.Now}");
                    Console.WriteLine($"Temperature: {tempValue.Celsius:0.#}\u00B0C");
                    Console.WriteLine($"Pressure: {preValue/100:0.##}hPa");
                    Console.WriteLine($"Relative humidity: {humValue:0.#}%\n");

                    Thread.Sleep(2000);
                }
            }
        }
コード例 #3
0
ファイル: Bme280.sample.cs プロジェクト: giegloop/iot-1
        static async Task Main(string[] args)
        {
            Console.WriteLine("Hello Bme280!");

            //bus id on the raspberry pi 3
            const int busId = 1;
            //set this to the current sea level pressure in the area for correct altitude readings
            const double defaultSeaLevelPressure = 1033.00;

            var i2cSettings = new I2cConnectionSettings(busId, Bme280.DefaultI2cAddress);
            var i2cDevice   = new UnixI2cDevice(i2cSettings);
            var i2CBmpe80   = new Bme280(i2cDevice);

            using (i2CBmpe80)
            {
                while (true)
                {
                    ////set mode forced so device sleeps after read
                    i2CBmpe80.SetPowerMode(PowerMode.Forced);

                    //set samplings
                    i2CBmpe80.SetTemperatureSampling(Sampling.UltraLowPower);
                    i2CBmpe80.SetPressureSampling(Sampling.UltraLowPower);

                    //read values
                    Temperature tempValue = await i2CBmpe80.ReadTemperatureAsync();

                    Console.WriteLine($"Temperature {tempValue.Celsius}");
                    double preValue = await i2CBmpe80.ReadPressureAsync();

                    Console.WriteLine($"Pressure {preValue}");
                    double altValue = await i2CBmpe80.ReadAltitudeAsync(defaultSeaLevelPressure);

                    Console.WriteLine($"Altitude: {altValue}");
                    Thread.Sleep(1000);

                    //set higher sampling
                    i2CBmpe80.SetTemperatureSampling(Sampling.LowPower);
                    Console.WriteLine(i2CBmpe80.ReadTemperatureSampling());
                    i2CBmpe80.SetPressureSampling(Sampling.UltraHighResolution);
                    Console.WriteLine(i2CBmpe80.ReadPressureSampling());

                    //set mode forced and read again
                    i2CBmpe80.SetPowerMode(PowerMode.Forced);

                    //read values
                    tempValue = await i2CBmpe80.ReadTemperatureAsync();

                    Console.WriteLine($"Temperature {tempValue}");
                    preValue = await i2CBmpe80.ReadPressureAsync();

                    Console.WriteLine($"Pressure {preValue}");
                    altValue = await i2CBmpe80.ReadAltitudeAsync(defaultSeaLevelPressure);

                    Console.WriteLine($"Altitude: {altValue}");
                    Thread.Sleep(5000);

                    //set sampling to higher
                    i2CBmpe80.SetTemperatureSampling(Sampling.UltraHighResolution);
                    Console.WriteLine(i2CBmpe80.ReadTemperatureSampling());
                    i2CBmpe80.SetPressureSampling(Sampling.UltraLowPower);
                    Console.WriteLine(i2CBmpe80.ReadPressureSampling());
                }
            }
        }