Esempio n. 1
0
        private void measure()
        {
            resetTime();
            MeasureResultTera result;

            this.MeasureStatus = MEASURE_STATUS.IS_GOING;
            do
            {
                this.teraDevice.DeviceForm.updateResultField();
                Thread.Sleep(700);
                result = new MeasureResultTera(this, this.teraDevice);
                this.teraDevice.DoMeasure(ref result);
                if (!result.IsCompleted)
                {
                    TeraMeasure.measureError("Превышено время ожидания результата"); break;
                }
                result.SecondsFromStart = measSeconds;
                if (result.Status > 0)
                {
                    break;
                }

                ResultCollectionsList.Add(result);


                if (StatCycleNumber < this.AveragingTimes)
                {
                    StatCycleNumber++; continue;
                }                                                                           //Если статистическое испытание, то уходим на следующий подциклa
                this.teraDevice.DeviceForm.updateResultField();
                if (!this.IsCyclicMeasure && this.CycleNumber == this.CycleTimes)
                {
                    break;
                }
                this.CycleNumber++;
            } while (true);

            if (result.Status != TERA_RESULT_STATUS.SUCC && result.Status != TERA_RESULT_STATUS.INTERRUPTED && result.Status != TERA_RESULT_STATUS.STATUS_VOLTAGE_SOURCE_IS_OFF)
            {
                string errMessage = "Неизвестная ошибка измерения";
                if (result.Status == TERA_RESULT_STATUS.INTEGRATOR_IS_ON_NEGATIVE)
                {
                    errMessage = "Интегратор находится в отрицательной области";
                }
                else if (result.Status == TERA_RESULT_STATUS.LOST_CIRCUIT_CORR_ERR_CODE)
                {
                    errMessage = "Не удалось произвести коррекцию токов утечки";
                }
                else if (result.Status == TERA_RESULT_STATUS.SHORT_CIRCUIT)
                {
                    errMessage = "Подключенный образец имеет слишком маленькое сопротивление.";
                }
                System.Windows.Forms.MessageBox.Show(errMessage, "Ошибка измерения", System.Windows.Forms.MessageBoxButtons.OK, System.Windows.Forms.MessageBoxIcon.Error);
            }
            else if (result.Status == TERA_RESULT_STATUS.INTERRUPTED || result.Status == TERA_RESULT_STATUS.STATUS_VOLTAGE_SOURCE_IS_OFF)
            {
                this.MeasureStatus = MEASURE_STATUS.STOPED;
            }
        }
Esempio n. 2
0
 private void initPage()
 {
     this.measure = new TeraMeasure(teraDevice, MEASURE_TYPE.HAND);
     fillHandMeasureParameters();
     buildIsolationMaterialArr();
     switchBringingParams();
     getCameraDiametersByCameraId();
     cleanMeasInfo();
 }
 public MeasureResultTera(TeraMeasure m, TeraDevice d) : base()
 {
     this.Measure               = m;
     this.TeraDevice            = d;
     this.CycleNumber           = m.CycleNumber;
     this.MeasureNumber         = m.Number;
     this.StatCycleNumber       = m.StatCycleNumber;
     this.Voltage               = m.Voltage;
     this.Material              = m.Material;
     this.Temperature           = m.Temperature;
     this.BringingTypeId        = m.BringingTypeId;
     this.BringingLengthMeasure = m.BringingLengthMeasure;
 }
Esempio n. 4
0
        public void updateMeasureStatus(MEASURE_STATUS status) //Для обновления поля результата из другого потока в котором проходит испытание
        {
            if (InvokeRequired)
            {
                BeginInvoke(new updateMeasureStatusDelegate(updateMeasureStatus), new object[] { status });
                return;
            }
            else
            {
                bool isActive = status != MEASURE_STATUS.NOT_STARTED && status != MEASURE_STATUS.FINISHED && status != MEASURE_STATUS.STOPED;
                this.measureStatus.Text           = TeraMeasure.StatusString(status);
                this.startHandMeasureBut.Enabled  = !(status == MEASURE_STATUS.DISCHARGE);
                this.measureIsActive              = isActive;
                this.measureSettingsGroup.Enabled = !isActive;
                autoCorrCb.Enabled = this.comboBoxResistance.Enabled = this.teraEtalonMapComboBox.Enabled = this.comboBoxMode.Enabled = !isActive;

                startHandMeasureBut.Text = !isActive ? "ПУСК ИЗМЕРЕНИЯ" : "ОСТАНОВИТЬ ИЗМЕРЕНИЯ";
            }
        }
Esempio n. 5
0
        private void comboBoxMode_SelectedIndexChanged(object sender, EventArgs e)
        {
            ComboBox cb = sender as ComboBox;

            switch (cb.SelectedIndex)
            {
            case 0:
                this.measure = new TeraMeasure(teraDevice, MEASURE_TYPE.HAND);
                verificationCalibrationPanel.Visible = false;
                handMeasurePanel.Visible             = true;
                measureSettingsGroup.Enabled         = true;
                averagingTimes.Enabled = cycleTimes.Enabled = polarizationDelay.Enabled = isCyclicMeasure.Enabled = dischargeDelay.Enabled = voltageComboBox.Enabled = normaField.Enabled = true;
                initPage();
                break;

            case 1:
                this.measure = new TeraMeasure(teraDevice, MEASURE_TYPE.VERIFICATION);
                verificationCalibrationPanel.Visible = true;
                handMeasurePanel.Visible             = false;
                isCyclicMeasure.Enabled  = dischargeDelay.Enabled = voltageComboBox.Enabled = normaField.Enabled = false;
                cycleTimes.Enabled       = polarizationDelay.Enabled = true;
                cycleTimes.Value         = 10;
                isCyclicMeasure.Checked  = false;
                handMeasurePanel.Visible = false;
                //measureSettingsGroup.Enabled = false;
                fillEtalonMapComboBox();
                break;

            case 2:
                this.measure            = new TeraMeasure(teraDevice, MEASURE_TYPE.CALIBRATION);
                voltageComboBox.Enabled = verificationCalibrationPanel.Visible = true;
                //measureSettingsGroup.Enabled = false;
                isCyclicMeasure.Enabled = averagingTimes.Enabled = isCyclicMeasure.Checked = dischargeDelay.Enabled = normaField.Enabled = false;
                setCorrField(autoCorrCb.Checked);
                averagingTimes.Value         = 1;
                voltageComboBox.SelectedText = "10";
                handMeasurePanel.Visible     = false;
                fillEtalonMapComboBox();
                break;
            }
        }
Esempio n. 6
0
 private void cleanMeasInfo()
 {
     this.measureStatus.Text    = TeraMeasure.StatusString(MEASURE_STATUS.NOT_STARTED);
     this.measTimeLbl.Text      = this.normaLbl.Text = this.cycleCounterLbl.Text = this.statMeasNumbOfLbl.Text = this.midStatMeasValLbl.Text = this.measTimeLbl.Text = "";
     this.measureResultLbl.Text = "0.0 МОм";
 }