Esempio n. 1
0
        public void GivenDdiWhenGetUnitThenPullsFromIsoUomList()
        {
            var result   = _representationMapper.GetUnitForDdi(7);
            var expected = IsoUnitOfMeasureList.Mappings.Single(m => m.Unit == "mg/m²").AdaptCode;

            Assert.AreEqual(expected, result.Code);
        }
Esempio n. 2
0
        private MeteredValue GetSummaryMeteredValue(ISODataLogValue dlv)
        {
            if (dlv.ProcessDataDDI == null)
            {
                return(null);
            }
            int ddi = dlv.ProcessDataDDI.AsInt32DDI();

            int dataValue = 0;

            if (dlv.ProcessDataValue.HasValue)
            {
                dataValue = dlv.ProcessDataValue.Value;
            }

            var unitOfMeasure = RepresentationMapper.GetUnitForDdi(ddi);

            if (!DDIs.ContainsKey(ddi) || unitOfMeasure == null)
            {
                return(null);
            }

            DdiDefinition ddiDefintion = DDIs[ddi];

            return(new MeteredValue
            {
                Value = new NumericRepresentationValue(RepresentationMapper.Map(ddi) as NumericRepresentation,
                                                       unitOfMeasure, new NumericValue(unitOfMeasure, dataValue * ddiDefintion.Resolution))
            });
        }
        private NumericWorkingData MapNumericMeter(ISODataLogValue dlv, int deviceElementUseId)
        {
            var meter = new NumericWorkingData
            {
                UnitOfMeasure      = RepresentationMapper.GetUnitForDdi(dlv.ProcessDataDDI.AsInt32DDI()),
                DeviceElementUseId = deviceElementUseId,
                Representation     = RepresentationMapper.Map(dlv.ProcessDataDDI.AsInt32DDI())
            };

            return(meter);
        }
Esempio n. 4
0
        private MeteredValue GetSummaryMeteredValue(ISODataLogValue dlv)
        {
            if (dlv.ProcessDataDDI == null)
            {
                return(null);
            }
            int ddi = dlv.ProcessDataDDI.AsInt32DDI();

            int dataValue = 0;

            if (dlv.ProcessDataValue.HasValue)
            {
                dataValue = dlv.ProcessDataValue.Value;
            }

            var unitOfMeasure = RepresentationMapper.GetUnitForDdi(ddi);

            if (!DDIs.ContainsKey(ddi) || unitOfMeasure == null)
            {
                return(null);
            }

            DdiDefinition ddiDefintion = DDIs[ddi];

            int?deviceConfigurationID = null;
            int?deviceElementID       = TaskDataMapper.InstanceIDMap.GetADAPTID(dlv.DeviceElementIdRef);

            if (deviceElementID.HasValue)
            {
                //Since Device creation is on-demand, we need to call GetDeviceElementConfiguration here to ensure the relevant device is created if it hasn't been yet.
                var hierarchy          = TaskDataMapper?.DeviceElementHierarchies?.GetRelevantHierarchy(dlv.DeviceElementIdRef);
                var adaptDeviceElement = DataModel?.Catalog?.DeviceElements?.FirstOrDefault(d => d?.Id?.ReferenceId == deviceElementID.Value);
                if (hierarchy != null && adaptDeviceElement != null)
                {
                    DeviceElementConfiguration config = DeviceElementMapper.GetDeviceElementConfiguration(adaptDeviceElement, hierarchy, DataModel.Catalog);
                    if (config != null)
                    {
                        deviceConfigurationID = config.Id.ReferenceId;
                    }
                }
            }

            return(new MeteredValue
            {
                Value = new NumericRepresentationValue(RepresentationMapper.Map(ddi) as NumericRepresentation,
                                                       unitOfMeasure,
                                                       new NumericValue(unitOfMeasure, dataValue * ddiDefintion.Resolution)),
                DeviceConfigurationId = deviceConfigurationID
            });
        }
Esempio n. 5
0
        private MeteredValue GetSummaryMeteredValue(ISODataLogValue dlv)
        {
            if (dlv.ProcessDataDDI == null)
            {
                return(null);
            }
            int ddi = dlv.ProcessDataDDI.AsInt32DDI();

            int dataValue = 0;

            if (dlv.ProcessDataValue.HasValue)
            {
                dataValue = dlv.ProcessDataValue.Value;
            }

            var unitOfMeasure = RepresentationMapper.GetUnitForDdi(ddi);

            if (!DDIs.ContainsKey(ddi) || unitOfMeasure == null)
            {
                return(null);
            }

            DdiDefinition ddiDefintion = DDIs[ddi];

            int?deviceConfigurationID = null;
            int?deviceElementID       = TaskDataMapper.InstanceIDMap.GetADAPTID(dlv.DeviceElementIdRef);

            if (deviceElementID.HasValue)
            {
                DeviceElementConfiguration config = DataModel.Catalog.DeviceElementConfigurations.FirstOrDefault(c => c.DeviceElementId == deviceElementID.Value);
                if (config != null)
                {
                    deviceConfigurationID = config.Id.ReferenceId;
                }
            }

            return(new MeteredValue
            {
                Value = new NumericRepresentationValue(RepresentationMapper.Map(ddi) as NumericRepresentation,
                                                       unitOfMeasure,
                                                       new NumericValue(unitOfMeasure, dataValue * ddiDefintion.Resolution)),
                DeviceConfigurationId = deviceConfigurationID
            });
        }