Esempio n. 1
0
 private void button25_Click(object sender, EventArgs e)
 {
     try
     {
         OperateResult <byte[]> read = keyence_net.Read(textBox6.Text, ushort.Parse(textBox9.Text));
         if (read.IsSuccess)
         {
             textBox10.Text = "结果:" + HslCommunication.BasicFramework.SoftBasic.ByteToHexString(read.Content);
         }
         else
         {
             MessageBox.Show("读取失败:" + read.ToMessageShowString( ));
         }
     }
     catch (Exception ex)
     {
         MessageBox.Show("读取失败:" + ex.Message);
     }
 }
        private void test5( )
        {
            // The complex situation is that you need to parse the byte array yourself.
            // Here's just one example.
            OperateResult <byte[]> read = keyence_net.Read("D100", 10);

            if (read.IsSuccess)
            {
                int    count   = keyence_net.ByteTransform.TransInt32(read.Content, 0);
                float  temp    = keyence_net.ByteTransform.TransSingle(read.Content, 4);
                short  name1   = keyence_net.ByteTransform.TransInt16(read.Content, 8);
                string barcode = Encoding.ASCII.GetString(read.Content, 10, 10);
            }
        }
Esempio n. 3
0
        //PLC读取
        private object ReadSieTcpValue(Config.PlcTypeItem plctype, Config.PlcDataItem plcdata, KeyenceMcNet plc)
        {
            try
            {
                if (plctype == null || !plctype.IsConnected || plcdata == null || plc == null)
                {
                    return(null);
                }

                switch (plcdata.DataType)
                {
                case Common.DataTypes.Bool:    //Bool
                    plcdata.ValueNew = plc.ReadBool(plcdata.Address).Content;
                    break;

                case Common.DataTypes.Byte:    //Byte
                    plcdata.ValueNew = plc.Read(plcdata.Address, 1).Content;
                    break;

                case Common.DataTypes.Short:
                    plcdata.ValueNew = plc.ReadInt16(plcdata.Address).Content;
                    break;

                case Common.DataTypes.Ushort:
                    plcdata.ValueNew = plc.ReadUInt16(plcdata.Address).Content;
                    break;

                case Common.DataTypes.Int:
                    plcdata.ValueNew = plc.ReadInt32(plcdata.Address).Content;
                    break;

                case Common.DataTypes.UInt:
                    plcdata.ValueNew = plc.ReadUInt32(plcdata.Address).Content;
                    break;

                case Common.DataTypes.Long:
                    long lValueNew = 0;
                    if (long.TryParse(plc.ReadInt64(plcdata.Address).Content.ToString(), out lValueNew))
                    {
                        long temp = BpLong.SwapInt64(lValueNew);
                        plcdata.ValueNew = temp;
                    }
                    // plcdata.ValueNew = plc.ReadInt64(plcdata.Address).Content;
                    break;

                case Common.DataTypes.ULong:
                    plcdata.ValueNew = plc.ReadUInt64(plcdata.Address).Content;
                    break;

                case Common.DataTypes.Float:
                    plcdata.ValueNew = plc.ReadFloat(plcdata.Address).Content;
                    break;

                case Common.DataTypes.Double:
                    plcdata.ValueNew = plc.ReadDouble(plcdata.Address).Content;
                    break;

                case Common.DataTypes.String:
                    HslCommunication.OperateResult <byte[]> data = (HslCommunication.OperateResult <byte[]>)plc.Read(plcdata.Address, 50);
                    if (data != null && data.Content != null && data.Content.Length > 2)
                    {
                        List <byte> lstData = new List <byte>();
                        int         nLen    = data.Content[1];
                        for (int i = 2; i < nLen + 2; i++)
                        {
                            lstData.Add(data.Content[i]);
                        }
                        plcdata.ValueNew = System.Text.Encoding.ASCII.GetString(lstData.ToArray());
                    }
                    break;

                default:
                    break;
                }
            }
            catch
            {
                //MessageBox.Show(ex.Message);
            }

            return(plcdata.ValueNew);
        }