        bool LoadFLASH(DebugStartContext context, IDebugStartService service, ISimpleGDBSession session, ESP32OpenOCDSettings settings, ESP32GDBStub stub)
        {
            string val;

            if (!service.SystemDictionary.TryGetValue("com.sysprogs.esp32.load_flash", out val) || val != "1")
            {
                //This is a RAM-only configuration
                return(session.RunGDBCommand("load").IsDone);
            }
            else
            {
                if (settings.ProgramFLASHUsingExternalTool)
                {
                    var svc = service.AdvancedDebugService as IExternallyProgrammedProjectDebugService ?? throw new Exception("This project type does not support external FLASH memory programming");
                    svc.ProgramFLASHMemoryUsingExternalTool(settings.ProgramMode);
                }
                else
                {
                    List <ProgrammableRegion> blocks = BuildProgrammableBlocksFromSettings(service, settings);

                    Regex rgFLASHSize = new Regex("Auto-detected flash size ([0-9]+) KB");
                    if (settings.CheckFLASHSize)
                    {
                        var match = stub.Tool.AllText.Split('\n').Select(s => rgFLASHSize.Match(s)).FirstOrDefault(m => m.Success);
                        if (match != null)
                        {
                            int detectedSizeKB  = int.Parse(match.Groups[1].Value);
                            int specifiedSizeMB = 0;
                            switch (settings.FLASHSettings.Size)
                            {
                            case ESP8266BinaryImage.ESP32FLASHSize.size1MB:
                                specifiedSizeMB = 1;
                                break;

                            case ESP8266BinaryImage.ESP32FLASHSize.size2MB:
                                specifiedSizeMB = 2;
                                break;

                            case ESP8266BinaryImage.ESP32FLASHSize.size4MB:
                                specifiedSizeMB = 4;
                                break;

                            case ESP8266BinaryImage.ESP32FLASHSize.size8MB:
                                specifiedSizeMB = 8;
                                break;

                            case ESP8266BinaryImage.ESP32FLASHSize.size16MB:
                                specifiedSizeMB = 16;
                                break;
                            }

                            if (detectedSizeKB < (specifiedSizeMB * 1024) && detectedSizeKB >= 1024)
                            {
                                if (service.GUIService.Prompt($"The FLASH size specified via Project Properties is greater than the actual SPI FLASH size on your device. Please switch FLASH size to {detectedSizeKB / 1024}MB or less.\nDo you want to cancel FLASH programming?", System.Windows.Forms.MessageBoxIcon.Warning))
                                {
                                    throw new OperationCanceledException();
                                }
                            }
                        }
                    }

                    using (var ctx = session.CreateScopedProgressReporter("Programming FLASH...", new[] { "Programming FLASH memory" }))
                    {
                        int   blkNum        = 0;
                        Regex rgWriteXBytes = new Regex("wrote ([0-9]+) bytes from file");
                        foreach (var blk in blocks)
                        {
                            ctx.ReportTaskProgress(blkNum++, blocks.Count);
                            string path = blk.FileName.Replace('\\', '/');
                            if (path.Contains(" "))
                            {
                                throw new Exception($"ESP32 OpenOCD does not support spaces in paths. Please relocate {path} to a location without spaces");
                            }
                            var  result    = session.RunGDBCommand($"mon program_esp32 \"{path}\" 0x{blk.Offset:x}");
                            bool succeeded = result.StubOutput?.FirstOrDefault(l => l.Contains("** Programming Finished **")) != null;
                            if (!succeeded)
                            {
                                throw new Exception("FLASH programming failed. Please review the gdb/OpenOCD logs for details.");
                            }
                            var m = result.StubOutput.Select(l => rgWriteXBytes.Match(l)).FirstOrDefault(m2 => m2.Success);
                            if (m == null)
                            {
                                throw new Exception("FLASH programming did not report the amount of written bytes. Please review the gdb/OpenOCD logs for details.");
                            }
                            int bytesWritten = int.Parse(m.Groups[1].Value);
                            if (bytesWritten == 0 && blk.Size > 0)
                            {
                                throw new Exception("FLASH programming did not write any data. This is a known bug of ESP32 OpenOCD. Please restart your device and JTAG programmer and try again.");
                            }
                        }
                    }
                }
            }

            if (!session.RunGDBCommand("mon reset halt").IsDone)
            {
                throw new Exception("Failed to reset target after programming");
            }

            return(true);
        }
Esempio n. 2
0
        bool LoadFLASH(DebugStartContext context, IDebugStartService service, ISimpleGDBSession session, ESP32OpenOCDSettings settings, ESP32GDBStub stub)
        {
            string val;

            if (!service.SystemDictionary.TryGetValue("com.sysprogs.esp32.load_flash", out val) || val != "1")
            {
                //This is a RAM-only configuration
                return(session.RunGDBCommand("load").IsDone);
            }
            else
            {
                if (settings.ProgramUsingIDF)
                {
                    string bash, bashArgs;
                    if (!service.SystemDictionary.TryGetValue("com.sysprogs.esp32.esptool.bash", out bash) || !service.SystemDictionary.TryGetValue("com.sysprogs.esp32.esptool.bash_args", out bashArgs))
                    {
                        throw new Exception("ESP-IDF did not report esptool arguments");
                    }

                    if (service.SystemDictionary.TryGetValue("com.sysprogs.esp32.esptool.script", out var script) && File.Exists(script))
                    {
                        var lines = File.ReadAllLines(script).ToList();
                        int idx   = Enumerable.Range(0, lines.Count).FirstOrDefault(i => lines[i].Contains("def hard_reset(self):"));
                        if (idx > 0 && idx < (lines.Count - 1))
                        {
                            if (!lines[idx + 1].Contains("self._port.setDTR(False)"))
                            {
                                if (service.GUIService.Prompt("The esptool.py binary used in the current ESP-IDF contains known compatibility issue with Cygwin. Do you want to patch it automatically?"))
                                {
                                    Regex rgIndent = new Regex("^([ \t]*)[^ \t]");
                                    var   m        = rgIndent.Match(lines[idx + 1]);
                                    lines.Insert(idx + 1, m.Groups[1].Value + "self._port.setDTR(False)  # IO0=HIGH");
                                    File.WriteAllLines(script, lines.ToArray());
                                }
                            }
                        }
                    }

                    var tool = service.LaunchCommandLineTool(new CommandLineToolLaunchInfo
                    {
                        Command   = bash,
                        Arguments = bashArgs
                    });

                    ESP32StubDebugController.GDBStubInstance.ReportFLASHProgrammingProgress(tool, service, session);

                    string text       = tool.AllText;
                    int    validLines = text.Split('\n').Count(l => l.Trim() == "Hash of data verified.");
                    int    binCount   = 0;
                    if (service.MCU.Configuration.TryGetValue("com.sysprogs.esp32.esptool.binaries.count", out var tmp))
                    {
                        int.TryParse(tmp, out binCount);
                    }
                    binCount = 0;

                    if (validLines < binCount)
                    {
                        service.GUIService.Report("Warning: some of the FLASH regions could not be programmed. Please examine the stub output for details.", System.Windows.Forms.MessageBoxIcon.Warning);
                    }
                }
                else
                {
                    List <ProgrammableRegion> blocks;
                    if (service.MCU.Configuration.TryGetValue("com.sysprogs.esp32.esptool.binaries.count", out var tmp) && int.TryParse(tmp, out var binaryCount) && binaryCount > 0)
                    {
                        blocks = new List <ProgrammableRegion>();
                        for (int i = 0; i < binaryCount; i++)
                        {
                            string fn = service.MCU.Configuration[$"com.sysprogs.esp32.esptool.binaries[{i}].path"];

                            blocks.Add(new ProgrammableRegion
                            {
                                FileName = fn,
                                Size     = File.ReadAllBytes(fn).Length,
                                Offset   = int.Parse(service.MCU.Configuration[$"com.sysprogs.esp32.esptool.binaries[{i}].address"])
                            });
                        }
                    }
                    else
                    {
                        bool patchBootloader = (settings as IESP32Settings)?.PatchBootloader ?? false;
                        blocks = ESP32StartupSequence.BuildFLASHImages(service.TargetPath, service.SystemDictionary, settings.FLASHSettings, patchBootloader);
                    }

                    if (settings.FLASHResources != null)
                    {
                        foreach (var r in settings.FLASHResources)
                        {
                            if (r.Valid)
                            {
                                blocks.Add(r.ToProgrammableRegion(service));
                            }
                        }
                    }

                    Regex rgFLASHSize = new Regex("Auto-detected flash size ([0-9]+) KB");
                    if (settings.CheckFLASHSize)
                    {
                        var match = stub.Tool.AllText.Split('\n').Select(s => rgFLASHSize.Match(s)).FirstOrDefault(m => m.Success);
                        if (match != null)
                        {
                            int detectedSizeKB  = int.Parse(match.Groups[1].Value);
                            int specifiedSizeMB = 0;
                            switch (settings.FLASHSettings.Size)
                            {
                            case ESP8266BinaryImage.ESP32FLASHSize.size1MB:
                                specifiedSizeMB = 1;
                                break;

                            case ESP8266BinaryImage.ESP32FLASHSize.size2MB:
                                specifiedSizeMB = 2;
                                break;

                            case ESP8266BinaryImage.ESP32FLASHSize.size4MB:
                                specifiedSizeMB = 4;
                                break;

                            case ESP8266BinaryImage.ESP32FLASHSize.size8MB:
                                specifiedSizeMB = 8;
                                break;

                            case ESP8266BinaryImage.ESP32FLASHSize.size16MB:
                                specifiedSizeMB = 16;
                                break;
                            }

                            if (detectedSizeKB < (specifiedSizeMB * 1024) && detectedSizeKB >= 1024)
                            {
                                if (service.GUIService.Prompt($"The FLASH size specified via Project Properties is greater than the actual SPI FLASH size on your device. Please switch FLASH size to {detectedSizeKB / 1024}MB or less.\nDo you want to cancel FLASH programming?", System.Windows.Forms.MessageBoxIcon.Warning))
                                {
                                    throw new OperationCanceledException();
                                }
                            }
                        }
                    }

                    using (var ctx = session.CreateScopedProgressReporter("Programming FLASH...", new[] { "Programming FLASH memory" }))
                    {
                        int   blkNum        = 0;
                        Regex rgWriteXBytes = new Regex("wrote ([0-9]+) bytes from file");
                        foreach (var blk in blocks)
                        {
                            ctx.ReportTaskProgress(blkNum++, blocks.Count);
                            string path      = blk.FileName.Replace('\\', '/');
                            var    result    = session.RunGDBCommand($"mon program_esp32 \"{path}\" 0x{blk.Offset:x}");
                            bool   succeeded = result.StubOutput?.FirstOrDefault(l => l.Contains("** Programming Finished **")) != null;
                            if (!succeeded)
                            {
                                throw new Exception("FLASH programming failed. Please review the gdb/OpenOCD logs for details.");
                            }
                            var m = result.StubOutput.Select(l => rgWriteXBytes.Match(l)).FirstOrDefault(m2 => m2.Success);
                            if (m == null)
                            {
                                throw new Exception("FLASH programming did not report the amount of written bytes. Please review the gdb/OpenOCD logs for details.");
                            }
                            int bytesWritten = int.Parse(m.Groups[1].Value);
                            if (bytesWritten == 0 && blk.Size > 0)
                            {
                                throw new Exception("FLASH programming did not write any data. This is a known bug of ESP32 OpenOCD. Please restart your device and JTAG programmer and try again.");
                            }
                        }
                    }
                }
            }

            if (!session.RunGDBCommand("mon reset halt").IsDone)
            {
                throw new Exception("Failed to reset target after programming");
            }

            return(true);
        }