Esempio n. 1
0
        public void test3()
        {
            MassTag massTag = new MassTag();

            massTag.ID = 56488;
            massTag.MonoIsotopicMass = 2275.1694779;
            massTag.ChargeState      = 3;
            massTag.MZ     = massTag.MonoIsotopicMass / massTag.ChargeState + 1.00727649;
            massTag.NETVal = 0.3520239f;


            Run run = new XCaliburRun(xcaliburTestfile);
            ChromAlignerUsingVIPERInfo chromAligner = new ChromAlignerUsingVIPERInfo();

            chromAligner.Execute(run);


            PeakImporterFromText peakImporter = new DeconTools.Backend.Data.PeakImporterFromText(xcaliburPeakDataFile);

            peakImporter.ImportPeaks(run.ResultCollection.MSPeakResultList);


            run.CurrentMassTag = massTag;

            Task peakChromGen = new PeakChromatogramGenerator(20);

            Task smoother     = new DeconTools.Backend.ProcessingTasks.Smoothers.DeconToolsSavitzkyGolaySmoother(2, 2, 2);
            Task peakDet      = new DeconTools.Backend.ProcessingTasks.PeakDetectors.ChromPeakDetector();
            Task chromPeakSel = new DeconTools.Backend.ProcessingTasks.ChromPeakSelector(1, 0.1);

            MSGeneratorFactory msgenFactory = new MSGeneratorFactory();
            Task msgen = msgenFactory.CreateMSGenerator(run.MSFileType);



            peakChromGen.Execute(run.ResultCollection);
            smoother.Execute(run.ResultCollection);
            peakDet.Execute(run.ResultCollection);
            chromPeakSel.Execute(run.ResultCollection);


            Console.WriteLine("Now generating MS....");
            msgen.Execute(run.ResultCollection);
            Console.WriteLine("----------- RESULTS ----------------------\n");
            TestUtilities.DisplayPeaks(run.PeakList);


            MassTagResultBase massTagResult = run.ResultCollection.MassTagResultList[massTag];

            massTagResult.DisplayToConsole();
            Assert.AreEqual(5512, massTagResult.ScanSet.PrimaryScanNumber);
        }
Esempio n. 2
0
        private Run setupRun(string runFile, string peaksFile)
        {
            RunFactory rf  = new RunFactory();
            Run        run = rf.CreateRun(runFile);

            ChromAlignerUsingVIPERInfo chromAligner = new ChromAlignerUsingVIPERInfo();

            chromAligner.Execute(run);

            PeakImporterFromText peakImporter = new DeconTools.Backend.Data.PeakImporterFromText(peaksFile);

            peakImporter.ImportPeaks(run.ResultCollection.MSPeakResultList);

            return(run);
        }
Esempio n. 3
0
        public void find_targetMassTag_131959Test1()
        {
            var run = new RunFactory().CreateRun(xcaliburTestfile);

            var masstagImporter = new MassTagFromTextFileImporter(massTagTestList1);
            var massTagColl     = masstagImporter.Import();

            Assert.AreEqual(2719, massTagColl.TargetList.Count);

            var chromAligner = new ChromAlignerUsingVIPERInfo();

            chromAligner.Execute(run);

            var peakImporter = new DeconTools.Backend.Data.PeakImporterFromText(xcaliburAllPeaksFile);

            peakImporter.ImportPeaks(run.ResultCollection.MSPeakResultList);


            //int mtID = 635428;
            var mtID = 131959;

            Task peakChromGen = new PeakChromatogramGenerator(20);
            Task smoother     = new DeconTools.Backend.ProcessingTasks.Smoothers.SavitzkyGolaySmoother(23, 2);
            Task zeroFill     = new DeconTools.Backend.ProcessingTasks.ZeroFillers.DeconToolsZeroFiller(3);
            Task peakDet      = new DeconTools.Backend.ProcessingTasks.PeakDetectors.ChromPeakDetector(0.5, 1);
            Task msPeakDet    = new DeconToolsPeakDetectorV2(1.3, 2, Globals.PeakFitType.QUADRATIC, true);

            var basicChromPeakSelParam = new ChromPeakSelectorParameters();

            basicChromPeakSelParam.NETTolerance     = 0.1f;
            basicChromPeakSelParam.PeakSelectorMode = Globals.PeakSelectorMode.ClosestToTarget;
            Task chromPeakSel = new BasicChromPeakSelector(basicChromPeakSelParam);


            Task msgen = MSGeneratorFactory.CreateMSGenerator(run.MSFileType);


            run.CurrentMassTag = massTagColl.TargetList.Find(p => p.ID == mtID);
            var mt = run.CurrentMassTag;

            mt.MZ = mt.MonoIsotopicMass / mt.ChargeState + Globals.PROTON_MASS;

            Task theorFeatureGen       = new TomTheorFeatureGenerator(DeconTools.Backend.Globals.LabellingType.NONE, 0.005);
            Task targetedFeatureFinder = new BasicTFF();
            Task fitScoreCalc          = new IsotopicProfileFitScoreCalculator();


            theorFeatureGen.Execute(run.ResultCollection);


            Console.WriteLine();
            Console.WriteLine();
            Console.WriteLine("------------------- MassTag = " + mt.ID + "---------------------------");
            Console.WriteLine("monoMass = " + mt.MonoIsotopicMass.ToString("0.0000") + "; monoMZ = " + mt.MZ.ToString("0.0000") + "; ChargeState = " + mt.ChargeState + "; NET = " + mt.NormalizedElutionTime.ToString("0.000") + "; Sequence = " + mt.Code + "; EmpiricalFormula= " + mt.EmpiricalFormula + "\n");

            peakChromGen.Execute(run.ResultCollection);
            smoother.Execute(run.ResultCollection);
            //TestUtilities.DisplayXYValues(run.ResultCollection);

            peakDet.Execute(run.ResultCollection);
            TestUtilities.DisplayPeaks(run.PeakList);

            chromPeakSel.Execute(run.ResultCollection);
            msgen.Execute(run.ResultCollection);
            //TestUtilities.DisplayXYValues(run.ResultCollection);
            msPeakDet.Execute(run.ResultCollection);
            targetedFeatureFinder.Execute(run.ResultCollection);
            fitScoreCalc.Execute(run.ResultCollection);

            var massTagResult = run.ResultCollection.MassTagResultList[mt];

            massTagResult.DisplayToConsole();



            //Console.WriteLine("------------------------------ end --------------------------");
        }
        private void getAlignmentInfo(Run run)
        {
            ChromAlignerUsingVIPERInfo chromAligner = new ChromAlignerUsingVIPERInfo();

            chromAligner.Execute(run);
        }
Esempio n. 5
0
        public void test1()
        {
            Run run = new XCaliburRun(xcaliburTestfile);
            MassTagCollection        massTagColl  = new MassTagCollection();
            MassTagIDGenericImporter mtidImporter = new MassTagIDGenericImporter(cysteineMassTagSourceFile1, '\t');

            mtidImporter.Import(massTagColl);

            MassTagFromSqlDBImporter importer = new MassTagFromSqlDBImporter("MT_Shewanella_ProdTest_P352", "porky");

            importer.Import(massTagColl);

            Assert.AreEqual(737, massTagColl.MassTagIDList.Count);

            Assert.AreEqual(826, massTagColl.MassTagList.Count);

            ChromAlignerUsingVIPERInfo chromAligner = new ChromAlignerUsingVIPERInfo();

            chromAligner.Execute(run);

            PeakImporterFromText peakImporter = new DeconTools.Backend.Data.PeakImporterFromText(xcaliburAllPeaksFile);

            peakImporter.ImportPeaks(run.ResultCollection.MSPeakResultList);

            Task peakChromGen = new PeakChromatogramGenerator(20);

            Task smoother     = new DeconTools.Backend.ProcessingTasks.Smoothers.DeconToolsSavitzkyGolaySmoother(11, 11, 2);
            Task peakDet      = new DeconTools.Backend.ProcessingTasks.PeakDetectors.ChromPeakDetector(0.5, 0.5);
            Task chromPeakSel = new DeconTools.Backend.ProcessingTasks.ChromPeakSelector(1, 0.01, Globals.PeakSelectorMode.CLOSEST_TO_TARGET);

            MSGeneratorFactory msgenFactory = new MSGeneratorFactory();
            Task msgen = msgenFactory.CreateMSGenerator(run.MSFileType);


            DeconToolsV2.Peaks.clsPeakProcessorParameters peakParams = new DeconToolsV2.Peaks.clsPeakProcessorParameters(2, 0.75, true, DeconToolsV2.Peaks.PEAK_FIT_TYPE.QUADRATIC);
            Task mspeakDet             = new DeconToolsPeakDetector(peakParams);
            Task theorFeatureGen       = new TomTheorFeatureGenerator();
            Task targetedFeatureFinder = new BasicTFF(6);
            Task exporter = new BasicMTResultSQLiteExporter(cysteineAnalysisOutput1);


            IsotopicProfileFitScoreCalculator fitScoreCalc = new IsotopicProfileFitScoreCalculator();

            int         successCounter = 0;
            List <long> timingResults  = new List <long>();

            foreach (MassTag mt in massTagColl.MassTagList)
            {
                run.CurrentMassTag = mt;
                mt.MZ = mt.MonoIsotopicMass / mt.ChargeState + Globals.PROTON_MASS;

                Console.WriteLine();
                Console.WriteLine();
                Console.WriteLine("------------------- MassTag = " + mt.ID + "---------------------------");
                Console.WriteLine("monoMass = " + mt.MonoIsotopicMass.ToString("0.0000") + "; monoMZ = " + mt.MZ.ToString("0.0000") + "; ChargeState = " + mt.ChargeState + "; NET = " + mt.NETVal.ToString("0.000") + "; Sequence = " + mt.PeptideSequence + "\n");


                Stopwatch sw = new Stopwatch();
                sw.Start();
                try
                {
                    peakChromGen.Execute(run.ResultCollection);
                    smoother.Execute(run.ResultCollection);
                    peakDet.Execute(run.ResultCollection);
                    chromPeakSel.Execute(run.ResultCollection);
                    msgen.Execute(run.ResultCollection);
                    mspeakDet.Execute(run.ResultCollection);
                    theorFeatureGen.Execute(run.ResultCollection);
                    targetedFeatureFinder.Execute(run.ResultCollection);
                    fitScoreCalc.Execute(run.ResultCollection);
                    MassTagResultBase massTagResult = run.ResultCollection.MassTagResultList[mt];
                    massTagResult.DisplayToConsole();


                    Console.WriteLine("------------------------------ end --------------------------");
                }
                catch (Exception ex)
                {
                    Console.WriteLine("Task failed. Message: " + ex.Message + ex.StackTrace);
                }
                sw.Stop();
                timingResults.Add(sw.ElapsedMilliseconds);

                if (mt == massTagColl.MassTagList.Last())
                {
                    exporter.Execute(run.ResultCollection);
                }
            }

            exporter.Cleanup();

            //List<IMassTagResult> successfulResults = run.ResultCollection.GetSuccessfulMassTagResults();

            foreach (long tr in timingResults)
            {
                Console.WriteLine(tr);
            }
            Console.WriteLine("-------- Analysis time for all MTs = " + timingResults.Sum());
            Console.WriteLine("-------- Average time for each MT = " + timingResults.Average());

            Console.WriteLine();
        }
Esempio n. 6
0
        public void run_fullAnalysisTest1()
        {
            Run run = new BrukerRun(rsph_AOnly_28_run1File);
            MassTagCollection massTagColl = new MassTagCollection();

            run.ResultCollection.MassTagResultType = DeconTools.Backend.Globals.MassTagResultType.N14N15_MASSTAG_RESULT;


            massTagColl.MassTagIDList = fourTestMTs;

            MassTagFromSqlDBImporter importer = new MassTagFromSqlDBImporter("MT_R_sphaeroides241_P513", "Albert");

            importer.chargeStateFilterThreshold = 0.05;
            importer.Import(massTagColl);

            Assert.AreEqual(7, massTagColl.MassTagList.Count);

            ChromAlignerUsingVIPERInfo chromAligner = new ChromAlignerUsingVIPERInfo();

            chromAligner.Execute(run);

            PeakImporterFromText peakImporter = new DeconTools.Backend.Data.PeakImporterFromText(rsph_Aonly_28_run1_scans500_1000_peaks);

            peakImporter.ImportPeaks(run.ResultCollection.MSPeakResultList);

            Task peakChromGen = new PeakChromatogramGenerator(20);

            Task smoother     = new DeconTools.Backend.ProcessingTasks.Smoothers.DeconToolsSavitzkyGolaySmoother(11, 11, 2);
            Task peakDet      = new DeconTools.Backend.ProcessingTasks.PeakDetectors.ChromPeakDetector(0.5, 0.5);
            Task chromPeakSel = new DeconTools.Backend.ProcessingTasks.ChromPeakSelector(1, 0.01, Globals.PeakSelectorMode.CLOSEST_TO_TARGET);

            MSGeneratorFactory msgenFactory = new MSGeneratorFactory();
            Task msgen = msgenFactory.CreateMSGenerator(run.MSFileType);


            DeconToolsV2.Peaks.clsPeakProcessorParameters peakParams = new DeconToolsV2.Peaks.clsPeakProcessorParameters(2, 3, false, DeconToolsV2.Peaks.PEAK_FIT_TYPE.QUADRATIC);
            Task mspeakDet       = new DeconToolsPeakDetector(peakParams);
            Task theorFeatureGen = new TomTheorFeatureGenerator();


            N14N15TFFTask finder = new N14N15TFFTask(0.01);



            N14N15QuantifierTask quant = new N14N15QuantifierTask(1);


            IsotopicProfileFitScoreCalculator fitScoreCalc = new IsotopicProfileFitScoreCalculator();

            List <long> timingResults = new List <long>();


            foreach (MassTag mt in massTagColl.MassTagList)
            {
                run.CurrentMassTag = mt;
                mt.MZ = mt.MonoIsotopicMass / mt.ChargeState + Globals.PROTON_MASS;

                Console.WriteLine();
                Console.WriteLine();
                Console.WriteLine("------------------- MassTag = " + mt.ID + "---------------------------");
                Console.WriteLine("monoMass = " + mt.MonoIsotopicMass.ToString("0.0000") + "; monoMZ = " + mt.MZ.ToString("0.0000") + "; ChargeState = " + mt.ChargeState + "; NET = " + mt.NETVal.ToString("0.000") + "; Sequence = " + mt.PeptideSequence + "\n");


                Stopwatch sw = new Stopwatch();
                sw.Start();
                try
                {
                    peakChromGen.Execute(run.ResultCollection);
                    smoother.Execute(run.ResultCollection);
                    peakDet.Execute(run.ResultCollection);
                    chromPeakSel.Execute(run.ResultCollection);
                    msgen.Execute(run.ResultCollection);
                    mspeakDet.Execute(run.ResultCollection);
                    theorFeatureGen.Execute(run.ResultCollection);
                    finder.Execute(run.ResultCollection);
                    quant.Execute(run.ResultCollection);
                    fitScoreCalc.Execute(run.ResultCollection);
                    MassTagResultBase massTagResult = run.ResultCollection.MassTagResultList[mt];
                    massTagResult.DisplayToConsole();


                    Console.WriteLine("------------------------------ end --------------------------");
                }
                catch (Exception ex)
                {
                    Console.WriteLine("Task failed. Message: " + ex.Message + ex.StackTrace);
                }
                sw.Stop();
                timingResults.Add(sw.ElapsedMilliseconds);
            }

            foreach (long tr in timingResults)
            {
                Console.WriteLine(tr);
            }
            Console.WriteLine("-------- Analysis time for all MTs = " + timingResults.Sum());
            Console.WriteLine("-------- Average time for each MT = " + timingResults.Average());

            Console.WriteLine();
        }
        public void smartChromPeakSelectorTest_noSumming()
        {
            var run = new RunFactory().CreateRun(xcaliburTestfile);

            run.Close();

            run = new RunFactory().CreateRun(xcaliburTestfile);


            var massTagColl = new TargetCollection();

            var masstagImporter = new MassTagFromTextFileImporter(massTagTestList1);

            massTagColl = masstagImporter.Import();

            var chromAligner = new ChromAlignerUsingVIPERInfo();

            chromAligner.Execute(run);

            var theorFeatureGen = new TomTheorFeatureGenerator(DeconTools.Backend.Globals.LabellingType.NONE, 0.005);

            var chromPeakDet = new ChromPeakDetector(0.5, 1);

            var smartchromParam        = new SmartChromPeakSelectorParameters();
            var smartChromPeakSelector = new SmartChromPeakSelector(smartchromParam);

            var basicChromParam        = new ChromPeakSelectorParameters();
            var basicChromPeakSelector = new BasicChromPeakSelector(basicChromParam);



            var msgen = MSGeneratorFactory.CreateMSGenerator(run.MSFileType);

            var iterativeTff = new IterativeTFF(new IterativeTFFParameters());

            var fitscoreCalc = new IsotopicProfileFitScoreCalculator();



            var testChromatogramDataFile = @"\\protoapps\UserData\Slysz\DeconTools_TestFiles\TargetedWorkflowStandards\massTag635428_chromatogramData.txt";

            var xydata = TestUtilities.LoadXYDataFromFile(testChromatogramDataFile);

            Assert.IsNotNull(xydata);

            run.XYData = xydata;
            // run.XYData.Display();

            run.CurrentMassTag = massTagColl.TargetList.Where(p => p.ID == 635428).First();

            Console.WriteLine("------MT = " + run.CurrentMassTag.ToString());

            theorFeatureGen.Execute(run.ResultCollection);
            chromPeakDet.Execute(run.ResultCollection);

            var result = run.ResultCollection.GetTargetedResult(run.CurrentMassTag);

            //first run the standard peak selector
            basicChromPeakSelector.Execute(run.ResultCollection);
            Assert.AreEqual(10066, (int)Math.Round(result.ChromPeakSelected.XValue));


            //now run the smart chrom peak selector
            run.XYData = xydata;
            chromPeakDet.Execute(run.ResultCollection);
            smartChromPeakSelector.Parameters.NETTolerance = 0.025f;
            smartChromPeakSelector.Execute(run.ResultCollection);

            msgen.Execute(run.ResultCollection);
            iterativeTff.Execute(run.ResultCollection);

            TestUtilities.DisplayPeaks(run.PeakList);

            fitscoreCalc.Execute(run.ResultCollection);


            Assert.AreEqual(9579, (int)Math.Round(result.ChromPeakSelected.XValue));
            //result.DisplayToConsole();


            TestUtilities.DisplayIsotopicProfileData(result.Target.IsotopicProfile);
        }
        public void smartChromPeakSelectorTest_withDynamicSumming()
        {
            var run = new RunFactory().CreateRun(xcaliburTestfile);

            var massTagColl = new TargetCollection();

            var masstagImporter = new MassTagFromTextFileImporter(massTagTestList1);

            massTagColl = masstagImporter.Import();

            var chromAligner = new ChromAlignerUsingVIPERInfo();

            chromAligner.Execute(run);

            var theorFeatureGen = new TomTheorFeatureGenerator(DeconTools.Backend.Globals.LabellingType.NONE, 0.005);

            var chromPeakDet = new ChromPeakDetector(0.5, 1);

            var smartchromParam        = new SmartChromPeakSelectorParameters();
            var smartChromPeakSelector = new SmartChromPeakSelector(smartchromParam);

            var basicChromPeakSelector = new BasicChromPeakSelector(new ChromPeakSelectorParameters());



            var msgen = MSGeneratorFactory.CreateMSGenerator(run.MSFileType);

            var iterativeTff = new IterativeTFF(new IterativeTFFParameters());

            var fitscoreCalc = new IsotopicProfileFitScoreCalculator();



            var testChromatogramDataFile = @"\\protoapps\UserData\Slysz\DeconTools_TestFiles\TargetedWorkflowStandards\massTag635428_chromatogramData.txt";

            var xydata = TestUtilities.LoadXYDataFromFile(testChromatogramDataFile);

            Assert.IsNotNull(xydata);

            run.XYData         = new XYData();
            run.XYData.Xvalues = xydata.Xvalues;
            run.XYData.Yvalues = xydata.Yvalues;
            // run.XYData.Display();

            run.CurrentMassTag = massTagColl.TargetList.Where(p => p.ID == 635428).First();

            Console.WriteLine("------MT = " + run.CurrentMassTag.ToString());

            theorFeatureGen.Execute(run.ResultCollection);
            chromPeakDet.Execute(run.ResultCollection);

            //first run the standard peak selector



            basicChromPeakSelector.Execute(run.ResultCollection);

            var result = run.ResultCollection.GetTargetedResult(run.CurrentMassTag);

            Assert.AreEqual(10066, (int)Math.Round(result.ChromPeakSelected.XValue));


            //now run the smart chrom peak selector
            run.XYData         = new XYData();
            run.XYData.Xvalues = xydata.Xvalues;
            run.XYData.Yvalues = xydata.Yvalues;
            chromPeakDet.Execute(run.ResultCollection);
            smartChromPeakSelector.Parameters.NETTolerance = 0.025f;
            smartChromPeakSelector.Parameters.MaxScansSummedInDynamicSumming = 51;
            smartChromPeakSelector.Parameters.SummingMode = SummingModeEnum.SUMMINGMODE_DYNAMIC;
            smartChromPeakSelector.Parameters.AreaOfPeakToSumInDynamicSumming = 1;

            smartChromPeakSelector.Execute(run.ResultCollection);

            msgen.Execute(run.ResultCollection);
            iterativeTff.Execute(run.ResultCollection);
            fitscoreCalc.Execute(run.ResultCollection);


            Console.WriteLine(result.ScanSet);
            Assert.AreEqual(14, result.ScanSet.IndexValues.Count);
            Assert.AreEqual(0.0104m, (decimal)Math.Round(result.Score, 4));
            Assert.AreEqual("9575 {9534, 9540, 9547, 9554, 9561, 9568, 9575, 9582, 9589, 9596, 9603, 9610, 9617, 9624}", result.ScanSet.ToString());

            run.XYData         = new XYData();
            run.XYData.Xvalues = xydata.Xvalues;
            run.XYData.Yvalues = xydata.Yvalues;
            chromPeakDet.Execute(run.ResultCollection);
            smartChromPeakSelector.Parameters.NETTolerance = 0.025f;
            smartChromPeakSelector.Parameters.MaxScansSummedInDynamicSumming = 51;
            smartChromPeakSelector.Parameters.SummingMode = SummingModeEnum.SUMMINGMODE_DYNAMIC;
            smartChromPeakSelector.Parameters.AreaOfPeakToSumInDynamicSumming = 2;

            smartChromPeakSelector.Execute(run.ResultCollection);

            msgen.Execute(run.ResultCollection);
            iterativeTff.Execute(run.ResultCollection);
            fitscoreCalc.Execute(run.ResultCollection);

            result.DisplayToConsole();

            Assert.AreEqual(9579, (int)Math.Round(result.ChromPeakSelected.XValue));
            Assert.AreEqual(0.025m, (decimal)(Math.Round(result.Score, 4)));
            //Console.WriteLine(result.ScanSet);
            Assert.AreEqual(26, result.ScanSet.IndexValues.Count);
            Assert.AreEqual("9575 {9493, 9500, 9506, 9513, 9520, 9527, 9534, 9540, 9547, 9554, 9561, 9568, 9575, 9582, 9589, 9596, 9603, 9610, 9617, 9624, 9631, 9638, 9645, 9652, 9658, 9665}", result.ScanSet.ToString());
        }