Exemple #1
0
        // private static void OnAnalogAddedEvent(object sender, EventArgs e)
        private void OnAnalogAddedEvent(object sender, EventArgs e)
        {
            Console.WriteLine("OnAnalogEventAdded started");
            Analog         analog = (Analog)e;
            IORequestBlock iorb   = new IORequestBlock()
            {
                RequestType           = RequestType.SEND,
                ProcessControllerName = analog.ProcContrName
            };

            DBContext dbContext = new DBContext();
            RTU       rtu;

            if ((rtu = dbContext.GetRTUByName(analog.ProcContrName)) != null)
            {
                iorb.ReqAddress = (ushort)rtu.GetCommandAddress(analog);
                bool shouldCommand = false;

                switch (rtu.Protocol)
                {
                case IndustryProtocols.ModbusTCP:

                    ModbusHandler mdbHandler = new ModbusHandler();
                    mdbHandler.Header = new ModbusApplicationHeader()
                    {
                        TransactionId = 0,
                        Length        = 5,
                        ProtocolId    = (ushort)IndustryProtocols.ModbusTCP,
                        DeviceAddress = rtu.Address
                    };

                    mdbHandler.Request = new WriteRequest()
                    {
                        StartAddr = (ushort)rtu.GetCommandAddress(analog)
                    };

                    if (shouldCommand = AnalogProcessor.InitialWorkPointAnalog(analog))
                    {
                        mdbHandler.Request.FunCode = FunctionCodes.WriteSingleRegister;
                        AnalogProcessor.EGUToRawValue(analog);
                        ((WriteRequest)mdbHandler.Request).Value = analog.RawCommValue;
                        iorb.SendBuff      = mdbHandler.PackData();
                        iorb.SendMsgLength = iorb.SendBuff.Length;
                        Console.WriteLine(BitConverter.ToString(iorb.SendBuff, 0, 12));
                        IORequests.EnqueueRequest(iorb);

                        analog.IsInit = true;
                    }

                    break;
                }
            }
            Console.WriteLine("OnAnalogEventAdded finished");
        }
Exemple #2
0
        /// <summary>
        /// Send Commands to simulator, to make its state consistent with RTDB
        /// </summary>
        public void InitializeSimulator()
        {
            List <ProcessVariable> pvs = dbContext.GetAllProcessVariables();

            if (pvs.Count != 0)
            {
                foreach (ProcessVariable pv in pvs)
                {
                    IORequestBlock iorb = new IORequestBlock()
                    {
                        RequestType           = RequestType.SEND,
                        ProcessControllerName = pv.ProcContrName
                    };

                    RTU rtu;
                    if ((rtu = dbContext.GetRTUByName(pv.ProcContrName)) != null)
                    {
                        iorb.ReqAddress = (ushort)rtu.GetCommandAddress(pv);
                        bool shouldCommand = false;

                        switch (rtu.Protocol)
                        {
                        case IndustryProtocols.ModbusTCP:

                            ModbusHandler mdbHandler = new ModbusHandler();
                            mdbHandler.Header = new ModbusApplicationHeader()
                            {
                                TransactionId = 0,
                                Length        = 5,
                                ProtocolId    = (ushort)IndustryProtocols.ModbusTCP,
                                DeviceAddress = rtu.Address
                            };

                            mdbHandler.Request = new WriteRequest()
                            {
                                StartAddr = (ushort)rtu.GetCommandAddress(pv)
                            };

                            switch (pv.Type)
                            {
                            // initialy, on simulator all digitals are set to 0 -> closed state
                            case VariableTypes.DIGITAL:
                                Digital digital = (Digital)pv;

                                CommandTypes comm;
                                if (shouldCommand = CommandValidator.InitialCommandingForDigital(digital, out comm))
                                {
                                    mdbHandler.Request.FunCode = FunctionCodes.WriteSingleCoil;
                                    ((WriteRequest)mdbHandler.Request).Value = (ushort)comm;
                                }
                                break;

                            case VariableTypes.ANALOG:
                                Analog analog = (Analog)pv;

                                if (shouldCommand = AnalogProcessor.InitialWorkPointAnalog(analog))
                                {
                                    mdbHandler.Request.FunCode = FunctionCodes.WriteSingleRegister;
                                    ((WriteRequest)mdbHandler.Request).Value = (ushort)analog.RawCommValue;
                                }
                                analog.IsInit = true;
                                break;

                            case VariableTypes.COUNTER:
                                Counter counter = (Counter)pv;

                                break;
                            }

                            if (shouldCommand)
                            {
                                iorb.SendBuff      = mdbHandler.PackData();
                                iorb.SendMsgLength = iorb.SendBuff.Length;
                                if (pv.Name == "MEAS_AN_1")
                                {
                                    Console.WriteLine(BitConverter.ToString(iorb.SendBuff, 0, 12));
                                }
                            }

                            break;
                        }

                        if (shouldCommand)
                        {
                            IORequests.EnqueueRequest(iorb);
                        }
                    }
                    else
                    {
                        // izbrisati omdah te procesne varijable sa rtu-om tog imena?
                        Console.WriteLine("Invalid config: ProcContrName = {0} does not exists.", pv.ProcContrName);
                        continue;
                    }
                }
            }
        }
Exemple #3
0
        // napravila, ali nisam testirala do kraja, to je nekad za buducnost, svakako ne treba sad :)
        public OMSSCADACommon.Responses.Response WriteSingleAnalog(string id, float value)
        {
            Console.WriteLine("WriteSingleAnalog!");

            Analog analog = null;

            OMSSCADACommon.Responses.Response response = new OMSSCADACommon.Responses.Response();

            // to do:
            //while (!Database.IsConfigurationRunning)
            //    Thread.Sleep(100);

            // getting PV from db
            ProcessVariable pv;

            if (dbContext.GetProcessVariableByName(id, out pv))
            {
                analog = (Analog)pv;
            }
            // does this ID exist in the database
            if (analog == null)
            {
                response.ResultMessage = ResultMessage.INVALID_ID;
                return(response);
            }

            // to do:
            // ovde provera opsega, alarma...bla, bla


            RTU rtu;

            if ((rtu = dbContext.GetRTUByName(analog.ProcContrName)) != null)
            {
                IORequestBlock iorb = new IORequestBlock()
                {
                    RequestType           = RequestType.SEND,
                    ProcessControllerName = analog.ProcContrName
                };

                iorb.ReqAddress = (ushort)rtu.GetCommandAddress(analog);

                bool shouldCommand = false;
                switch (rtu.Protocol)
                {
                case IndustryProtocols.ModbusTCP:

                    ModbusHandler mdbHandler = new ModbusHandler
                    {
                        Header = new ModbusApplicationHeader()
                        {
                            TransactionId = 0,
                            Length        = 5,
                            ProtocolId    = (ushort)IndustryProtocols.ModbusTCP,
                            DeviceAddress = rtu.Address
                        },

                        Request = new WriteRequest()
                        {
                            FunCode   = FunctionCodes.WriteSingleCoil,
                            StartAddr = (ushort)rtu.GetCommandAddress(analog)
                        }
                    };

                    if (shouldCommand = AnalogProcessor.SetNewWorkPoint(analog, value))
                    {
                        mdbHandler.Request.FunCode = FunctionCodes.WriteSingleRegister;
                        ((WriteRequest)mdbHandler.Request).Value = (ushort)analog.RawCommValue;
                    }

                    iorb.SendBuff      = mdbHandler.PackData();
                    iorb.SendMsgLength = iorb.SendBuff.Length;
                    break;
                }

                IORequests.EnqueueRequest(iorb);
                Console.WriteLine("enqued {0}", BitConverter.ToString(iorb.SendBuff, 0, 12));
                response.ResultMessage = ResultMessage.OK;
            }
            else
            {
                // rtu does not exist
            }

            return(response);
        }
Exemple #4
0
        /// <summary>
        /// Processing answers from Simulator - Process Controller
        /// </summary>
        public void ProcessPCAnwers()
        {
            while (!isShutdown)
            {
                bool           isSuccessful;
                IORequestBlock answer = IORequests.DequeueAnswer(out isSuccessful);

                if (isSuccessful)
                {
                    RTU rtu;
                    // sporno
                    //while (!Database.IsConfigurationRunning)
                    //    Thread.Sleep(100);
                    if ((rtu = dbContext.GetRTUByName(answer.ProcessControllerName)) != null)
                    {
                        switch (rtu.Protocol)
                        {
                        case IndustryProtocols.ModbusTCP:

                            ModbusHandler mdbHandler = new ModbusHandler();
                            mdbHandler.UnpackData(answer.RcvBuff, answer.RcvMsgLength);

                            switch (mdbHandler.Response.FunCode)
                            {
                            case FunctionCodes.ReadDiscreteInput:
                            {
                                BitReadResponse response = (BitReadResponse)mdbHandler.Response;
                                ProcessVariable pv;
                                Digital         target = null;

                                if (rtu.GetProcessVariableByAddress(answer.ReqAddress, out pv))
                                {
                                    target = (Digital)pv;
                                }

                                if (target != null)
                                {
                                    int[] array = new int[1];
                                    response.BitValues.CopyTo(array, 0);

                                    try
                                    {
                                        if (target.State != target.ValidStates[array[0]])
                                        {
                                            Console.WriteLine("CHANGE!");
                                            target.State = target.ValidStates[array[0]];

                                            ScadaModelParser parser = new ScadaModelParser();
                                            parser.SerializeScadaModel();

                                            DMSClient dMSClient = new DMSClient();
                                            dMSClient.ChangeOnSCADA(target.Name, target.State);
                                        }
                                    }
                                    catch
                                    {
                                        // Console.WriteLine("Digital variable {0}, state: INVALID", target.Name);
                                    }
                                }
                            }

                            break;

                            case FunctionCodes.ReadInputRegisters:
                            {
                                RegisterReadResponse response = (RegisterReadResponse)mdbHandler.Response;
                                ProcessVariable      pv;

                                Analog target = null;

                                // i ovde se zapravo cita iz baze! preko RTUa. znaci pristupamo rtuu, a moguce je da se desava rekonfiguracija.
                                if (rtu.GetProcessVariableByAddress(answer.ReqAddress, out pv))
                                {
                                    target = (Analog)pv;
                                }

                                if (target != null)
                                {
                                    ushort newRawAcqValue = response.RegValues[0];

                                    try
                                    {
                                        float newAcqValue;
                                        AnalogProcessor.RawValueToEGU(target, newRawAcqValue, out newAcqValue);

                                        // videti kad menjas kommande
                                        if (target.AcqValue != newAcqValue)
                                        {
                                            Console.WriteLine("CHANGE analog!");
                                            target.RawAcqValue = newRawAcqValue;
                                            target.AcqValue    = newAcqValue;

                                            ScadaModelParser parser = new ScadaModelParser();
                                            parser.SerializeScadaModel();

                                            DMSClient dMSClient = new DMSClient();
                                            // to do
                                            // dMSClient.ChangeOnSCADA(target.Name, target.State);
                                        }
                                    }
                                    catch
                                    {
                                        // Console.WriteLine("Digital variable {0}, state: INVALID", target.Name);
                                    }
                                }
                            }

                            break;
                            }

                            break;
                        }
                    }
                    else
                    {
                        Console.WriteLine("Answer disposed. Process Controller with name ={0} does not exit.", answer.ProcessControllerName);
                    }
                }

                Thread.Sleep(100);
            }

            Console.WriteLine("ProcessPCAnswers.shutdown=true");
            return;
        }