public static void PopulateTransformerWindingProperties(FTN.TransformerWinding cimTransformerWinding, ResourceDescription rd, ImportHelper importHelper, TransformAndLoadReport report)
        {
            if ((cimTransformerWinding != null) && (rd != null))
            {
                SCADAConverter.PopulateConductingEquipmentProperties(cimTransformerWinding, rd, importHelper, report);

                if (cimTransformerWinding.PowerTransformerHasValue)
                {
                    long gid = importHelper.GetMappedGID(cimTransformerWinding.PowerTransformer.ID);
                    if (gid < 0)
                    {
                        report.Report.Append("WARNING: Convert ").Append(cimTransformerWinding.GetType().ToString()).Append(" rdfID = \"").Append(cimTransformerWinding.ID);
                        report.Report.Append("\" - Failed to set reference to PowerTransformer: rdfID \"").Append(cimTransformerWinding.PowerTransformer.ID).AppendLine(" \" is not mapped to GID!");
                    }
                    rd.AddProperty(new Property(ModelCode.TRANSFORMERWINDING_POWERTR, gid));
                }
                if (cimTransformerWinding.RatioTapChangerHasValue)
                {
                    long gid = importHelper.GetMappedGID(cimTransformerWinding.RatioTapChanger.ID);
                    if (gid < 0)
                    {
                        report.Report.Append("WARNING: Convert ").Append(cimTransformerWinding.GetType().ToString()).Append(" rdfID = \"").Append(cimTransformerWinding.ID);
                        report.Report.Append("\" - Failed to set reference to RatioTapChanger: rdfID \"").Append(cimTransformerWinding.RatioTapChanger.ID).AppendLine(" \" is not mapped to GID!");
                    }
                    rd.AddProperty(new Property(ModelCode.TRANSFORMERWINDING_RATIOTC, gid));
                }
            }
        }
 public static void PopulateRegulatingCondEqProperties(FTN.RegulatingCondEq cimRegulatingCondEq, ResourceDescription rd, ImportHelper importHelper, TransformAndLoadReport report)
 {
     if ((cimRegulatingCondEq != null) && (rd != null))
     {
         SCADAConverter.PopulateConductingEquipmentProperties(cimRegulatingCondEq, rd, importHelper, report);
     }
 }
 public static void PopulateSwitchProperties(FTN.Switch cimSwitch, ResourceDescription rd, ImportHelper importHelper, TransformAndLoadReport report)
 {
     if ((cimSwitch != null) && (rd != null))
     {
         SCADAConverter.PopulateConductingEquipmentProperties(cimSwitch, rd, importHelper, report);
         if (cimSwitch.ManipulationCountHasValue)
         {
             rd.AddProperty(new Property(ModelCode.SWITCH_MANIPULATIONCOUNT, cimSwitch.ManipulationCount));
         }
     }
 }