/// <summary> /// 增加一条数据 /// </summary> public int Add(MesWeb.Model.T_SensorModule_T_ParameterCode model) { int rowsAffected; SqlParameter[] parameters = { new SqlParameter("@SensorModule_PARCODEID", SqlDbType.Int, 4), new SqlParameter("@SensorModuleID", SqlDbType.Int, 4), new SqlParameter("@ParameterCodeID", SqlDbType.Int, 4) }; parameters[0].Direction = ParameterDirection.Output; parameters[1].Value = model.SensorModuleID; parameters[2].Value = model.ParameterCodeID; DbHelperSQL.RunProcedure("T_SensorModule_T_ParameterCode_ADD", parameters, out rowsAffected); return((int)parameters[0].Value); }
/// <summary> /// 得到一个对象实体 /// </summary> public MesWeb.Model.T_SensorModule_T_ParameterCode DataRowToModel(DataRow row) { MesWeb.Model.T_SensorModule_T_ParameterCode model = new MesWeb.Model.T_SensorModule_T_ParameterCode(); if (row != null) { if (row["SensorModule_PARCODEID"] != null && row["SensorModule_PARCODEID"].ToString() != "") { model.SensorModule_PARCODEID = int.Parse(row["SensorModule_PARCODEID"].ToString()); } if (row["SensorModuleID"] != null && row["SensorModuleID"].ToString() != "") { model.SensorModuleID = int.Parse(row["SensorModuleID"].ToString()); } if (row["ParameterCodeID"] != null && row["ParameterCodeID"].ToString() != "") { model.ParameterCodeID = int.Parse(row["ParameterCodeID"].ToString()); } } return(model); }
/// <summary> /// 得到一个对象实体 /// </summary> public MesWeb.Model.T_SensorModule_T_ParameterCode GetModel(int SensorModule_PARCODEID) { SqlParameter[] parameters = { new SqlParameter("@SensorModule_PARCODEID", SqlDbType.Int, 4) }; parameters[0].Value = SensorModule_PARCODEID; MesWeb.Model.T_SensorModule_T_ParameterCode model = new MesWeb.Model.T_SensorModule_T_ParameterCode(); DataSet ds = DbHelperSQL.RunProcedure("T_SensorModule_T_ParameterCode_GetModel", parameters, "ds"); if (ds.Tables[0].Rows.Count > 0) { return(DataRowToModel(ds.Tables[0].Rows[0])); } else { return(null); } }
/// <summary> /// 更新一条数据 /// </summary> public bool Update(MesWeb.Model.T_SensorModule_T_ParameterCode model) { int rowsAffected = 0; SqlParameter[] parameters = { new SqlParameter("@SensorModule_PARCODEID", SqlDbType.Int, 4), new SqlParameter("@SensorModuleID", SqlDbType.Int, 4), new SqlParameter("@ParameterCodeID", SqlDbType.Int, 4) }; parameters[0].Value = model.SensorModule_PARCODEID; parameters[1].Value = model.SensorModuleID; parameters[2].Value = model.ParameterCodeID; DbHelperSQL.RunProcedure("T_SensorModule_T_ParameterCode_Update", parameters, out rowsAffected); if (rowsAffected > 0) { return(true); } else { return(false); } }