Exemple #1
0
        public static void GenerateBill(int id)
        {
            InitializeWorkbookBill();

            ISheet sheet1 = hssfworkbook.GetSheet("s");


            UniversalEntity ue = new UniversalEntity();
            //UniversalEntity uev = new UniversalEntity();

            UAbonent        ua    = new UAbonent();
            UAbonentDO      uado  = new UAbonentDO();
            UOrder          uo    = new UOrder();
            UOrderDO        uodo  = new UOrderDO();
            UOrderDetailsDO uodDO = new UOrderDetailsDO();

            ue = uado.RetrieveByOrderID(id);
            string header    = string.Empty;
            string actNumber = string.Empty;

            if (ue.Count > 0)
            {
                ua      = (UAbonent)ue[0];
                header += ua.Title + " \nюр адрес: " + ua.Address + " \n№ св. пл. НДС: " + ua.VATPay + " \n№ ИНН: " + ua.INN + " \nтел.: " + ua.Phone;
            }
            ue = uodo.RetrieveUOrderById(id);
            if (ue.Count > 0)
            {
                uo = (UOrder)ue[0];
                sheet1.GetRow(4).GetCell(GetLetterNumber("aj")).SetCellValue(uo.ID);
                sheet1.GetRow(9).GetCell(GetLetterNumber("ai")).SetCellValue(RuDateAndMoneyConverter.DateToTextLongUA(uo.DateIn) + "р.");
            }
            ue = uodDO.RetrieveUOrderDetailsByOrderID(id);
            sheet1.GetRow(16).GetCell(6).SetCellValue(header);



            int    count = ue.Count;
            double sum   = 0;
            int    row   = 20;

            if (count <= 5)
            {
                CustomRetrieverDO crDO = new CustomRetrieverDO();
                ue = crDO.RetrieveUActByOrderID5Low(id);
                if (ue.Count > 0)
                {
                    for (int i = row; i < ue.Count + row; i++)
                    {
                        ArrayList al = (ArrayList)ue[i - row];

                        sheet1.GetRow(i).GetCell(GetLetterNumber("a")).SetCellValue(string.Format("Определения метрологических характеристик водомера  D{0}, {1}, {2}", al[0].ToString(), al[1].ToString(), al[2].ToString()));
                        sheet1.GetRow(i).GetCell(GetLetterNumber("ad")).SetCellValue("шт.");
                        sheet1.GetRow(i).GetCell(GetLetterNumber("aj")).SetCellValue(al[4].ToString());
                        sheet1.GetRow(i).GetCell(GetLetterNumber("ap")).SetCellValue(Convert.ToDouble(al[3]).ToString("0.00"));
                        sheet1.GetRow(i).GetCell(GetLetterNumber("av")).SetCellValue(Convert.ToDouble(al[3]).ToString("0.00"));
                        sum += Convert.ToDouble(al[3]);
                    }
                }
            }
            else
            {
                CustomRetrieverDO crDO = new CustomRetrieverDO();
                ue = crDO.RetrieveUActByOrderID5High(id);
                if (ue.Count > 0)
                {
                    for (int i = row; i < ue.Count + row; i++)
                    {
                        ArrayList al = (ArrayList)ue[i - row];
                        //FOrderDetailsAct u = (FOrderDetailsAct)fodal[i - row];

                        sheet1.GetRow(i).GetCell(GetLetterNumber("a")).SetCellValue(string.Format("Определения метрологических характеристик водомера  D{0}", al[0].ToString()));
                        sheet1.GetRow(i).GetCell(GetLetterNumber("ad")).SetCellValue("шт.");
                        sheet1.GetRow(i).GetCell(GetLetterNumber("aj")).SetCellValue(al[3].ToString());
                        sheet1.GetRow(i).GetCell(GetLetterNumber("ap")).SetCellValue(Convert.ToDouble(al[3]).ToString("0.00"));
                        sheet1.GetRow(i).GetCell(GetLetterNumber("av")).SetCellValue(Convert.ToDouble(al[3]).ToString("0.00"));

                        sum += Convert.ToDouble(al[2]);
                    }
                }
            }

            /*int row = 20;
             * double sum = 0;
             *
             *
             *
             *
             *
             * if (ue.Count > 0)
             * {
             *  for (int i = row; i < ue.Count + row; i++)
             *  {
             *      UOrderDetails u = (UOrderDetails)ue[i - row];
             *
             *      sheet1.GetRow(i).GetCell(GetLetterNumber("a")).SetCellValue("Определения метрологических характеристик водомера ");
             *      sheet1.GetRow(i).GetCell(GetLetterNumber("ad")).SetCellValue("шт.");
             *      sheet1.GetRow(i).GetCell(GetLetterNumber("aj")).SetCellValue("1");
             *      sheet1.GetRow(i).GetCell(GetLetterNumber("ap")).SetCellValue(u.Price.ToString("0.00"));
             *      sheet1.GetRow(i).GetCell(GetLetterNumber("av")).SetCellValue(u.Price.ToString("0.00"));
             *      sum += u.Price;
             *  }
             * }*/
            sheet1.GetRow(31).GetCell(GetLetterNumber("av")).SetCellValue(sum.ToString("0.00"));
            sheet1.GetRow(32).GetCell(GetLetterNumber("av")).SetCellValue(Utilities.GetVAT(sum).ToString("0.00"));
            sheet1.GetRow(33).GetCell(GetLetterNumber("av")).SetCellValue((sum + Utilities.GetVAT(sum)).ToString("0.00"));
            sheet1.GetRow(35).GetCell(GetLetterNumber("a")).SetCellValue("Загальна сума, що підлягає оплаті: " + UADateAndMoneyConverter.CurrencyToTxt((sum + Utilities.GetVAT(sum)), true));
            //Загальна сума, що підлягає оплаті


            //Force excel to recalculate all the formula while open
            sheet1.ForceFormulaRecalculation = true;

            WriteToFileB();
        }
Exemple #2
0
        public static void GenerateUAct(int id)
        {
            UniversalEntity ue    = new UniversalEntity();
            UAbonent        ua    = new UAbonent();
            UAbonentDO      uado  = new UAbonentDO();
            UOrder          uo    = new UOrder();
            UOrderDO        uodo  = new UOrderDO();
            UOrderDetailsDO uodDO = new UOrderDetailsDO();

            ue = uado.RetrieveByOrderID(id);
            string header    = string.Empty;
            string actNumber = string.Empty;

            if (ue.Count > 0)
            {
                ua      = (UAbonent)ue[0];
                header += ua.Title + " \nюр адрес: " + ua.Address + " \n№ св. пл. НДС: " + ua.VATPay + " \n№ ИНН: " + ua.INN + " \nтел.: " + ua.Phone;
            }
            ue = uodo.RetrieveUOrderById(id);
            if (ue.Count > 0)
            {
                uo = (UOrder)ue[0];
                if (uo.DateOut.HasValue)
                {
                    actNumber = "  г. Донецк            АКТ № " + uo.ID + " от ____________________" + DateTime.Now.Year.ToString() + " г.";
                }
                else
                {
                    actNumber = "  г. Донецк            АКТ № " + uo.ID + " от ____________________" + DateTime.Now.Year.ToString() + " г.";
                }
            }

            ue = uodDO.RetrieveUOrderDetailsByOrderID(id);

            InitializeWorkbook();

            ISheet sheet1 = hssfworkbook.GetSheet("s");

            sheet1.GetRow(11).GetCell(0).SetCellValue("                             по договору (письму) № " + uo.ID + " от ____________________" + DateTime.Now.Year.ToString() + " г.");

            sheet1.GetRow(41).GetCell(0).SetCellValue("                             по договору (письму) № " + uo.ID + " от ____________________" + DateTime.Now.Year.ToString() + " г.");

            //create cell on rows, since rows do already exist,it's not necessary to create rows again.
            sheet1.GetRow(2).GetCell(3).SetCellValue(header);
            sheet1.GetRow(32).GetCell(3).SetCellValue(header);
            sheet1.GetRow(9).GetCell(0).SetCellValue(actNumber);
            sheet1.GetRow(39).GetCell(0).SetCellValue(actNumber);

            int    rowC = 44;
            int    row  = 14;
            double sum  = 0;

            int count = ue.Count;

            if (count <= 5)
            {
                CustomRetrieverDO crDO = new CustomRetrieverDO();
                ue = crDO.RetrieveUActByOrderID5Low(id);
                if (ue.Count > 0)
                {
                    for (int i = row; i < ue.Count + row; i++)
                    {
                        ArrayList al = (ArrayList)ue[i - row];
                        //FOrderDetailsAct u = (FOrderDetailsAct)fodal[i - row];

                        sheet1.GetRow(i).GetCell(0).SetCellValue(i - row + 1);
                        sheet1.GetRow(i).GetCell(1).SetCellValue(string.Format("Определения метрологических характеристик водомера  D{0}, {1}, {2}", al[0].ToString(), al[1].ToString(), al[2].ToString()));
                        sheet1.GetRow(i).GetCell(2).SetCellValue("калькуляция");
                        sheet1.GetRow(i).GetCell(3).SetCellValue("шт.");
                        sheet1.GetRow(i).GetCell(4).SetCellValue(al[4].ToString());
                        sheet1.GetRow(i).GetCell(5).SetCellValue(Convert.ToDouble(al[3]).ToString("0.00"));
                        sheet1.GetRow(i).GetCell(6).SetCellValue(Convert.ToDouble(al[3]).ToString("0.00"));


                        sheet1.GetRow(rowC).GetCell(0).SetCellValue(i - row + 1);
                        sheet1.GetRow(rowC).GetCell(1).SetCellValue(string.Format("Определения метрологических характеристик водомера  D{0}, {1}, {2}", al[0].ToString(), al[1].ToString(), al[2].ToString()));
                        sheet1.GetRow(rowC).GetCell(2).SetCellValue("калькуляция");
                        sheet1.GetRow(rowC).GetCell(3).SetCellValue("шт.");
                        sheet1.GetRow(rowC).GetCell(4).SetCellValue(al[4].ToString());
                        sheet1.GetRow(rowC).GetCell(5).SetCellValue(Convert.ToDouble(al[3]).ToString("0.00"));
                        sheet1.GetRow(rowC).GetCell(6).SetCellValue(Convert.ToDouble(al[3]).ToString("0.00"));

                        sum += Convert.ToDouble(al[3]);
                        rowC++;
                    }
                }
            }
            else
            {
                CustomRetrieverDO crDO = new CustomRetrieverDO();
                ue = crDO.RetrieveUActByOrderID5High(id);
                if (ue.Count > 0)
                {
                    for (int i = row; i < ue.Count + row; i++)
                    {
                        ArrayList al = (ArrayList)ue[i - row];
                        //FOrderDetailsAct u = (FOrderDetailsAct)fodal[i - row];

                        sheet1.GetRow(i).GetCell(0).SetCellValue(i - row + 1);
                        sheet1.GetRow(i).GetCell(1).SetCellValue(string.Format("Определения метрологических характеристик водомера  D{0}", al[0].ToString()));
                        sheet1.GetRow(i).GetCell(2).SetCellValue("калькуляция");
                        sheet1.GetRow(i).GetCell(3).SetCellValue("шт.");
                        sheet1.GetRow(i).GetCell(4).SetCellValue(al[3].ToString());
                        sheet1.GetRow(i).GetCell(5).SetCellValue(Convert.ToDouble(al[1]).ToString("0.00"));
                        sheet1.GetRow(i).GetCell(6).SetCellValue(Convert.ToDouble(al[2]).ToString("0.00"));


                        sheet1.GetRow(rowC).GetCell(0).SetCellValue(i - row + 1);
                        sheet1.GetRow(rowC).GetCell(1).SetCellValue(string.Format("Определения метрологических характеристик водомера  D{0}", al[0].ToString()));
                        sheet1.GetRow(rowC).GetCell(2).SetCellValue("калькуляция");
                        sheet1.GetRow(rowC).GetCell(3).SetCellValue("шт.");
                        sheet1.GetRow(rowC).GetCell(4).SetCellValue(al[3].ToString());
                        sheet1.GetRow(rowC).GetCell(5).SetCellValue(Convert.ToDouble(al[1]).ToString("0.00"));
                        sheet1.GetRow(rowC).GetCell(6).SetCellValue(Convert.ToDouble(al[2]).ToString("0.00"));

                        sum += Convert.ToDouble(al[2]);
                        rowC++;
                    }
                }
            }



            /*int rowC = 44;
             * int row = 14;
             * double sum = 0;
             * if (ue.Count > 0)
             * {
             *  for (int i = row; i < ue.Count + row; i++)
             *  {
             *      UOrderDetails u = (UOrderDetails)ue[i - row];
             *
             *      sheet1.GetRow(i).GetCell(0).SetCellValue(i - row+1);
             *      sheet1.GetRow(i).GetCell(1).SetCellValue(string.Format("Определения метрологических характеристик водомера  D{0}, {1}, {2}", al[0].ToString(), al[1].ToString(), al[2].ToString()));
             *      sheet1.GetRow(i).GetCell(2).SetCellValue("калькуляция");
             *      sheet1.GetRow(i).GetCell(3).SetCellValue("шт.");
             *      sheet1.GetRow(i).GetCell(4).SetCellValue("1");
             *      sheet1.GetRow(i).GetCell(5).SetCellValue(u.Price.ToString("0.00"));
             *      sheet1.GetRow(i).GetCell(6).SetCellValue(u.Price.ToString("0.00"));
             *
             *      sheet1.GetRow(rowC).GetCell(0).SetCellValue(i - row + 1);
             *      sheet1.GetRow(rowC).GetCell(1).SetCellValue(string.Format("Определения метрологических характеристик водомера  D{0}, {1}, {2}", al[0].ToString(), al[1].ToString(), al[2].ToString()));
             *      sheet1.GetRow(rowC).GetCell(2).SetCellValue("калькуляция");
             *      sheet1.GetRow(rowC).GetCell(3).SetCellValue("шт.");
             *      sheet1.GetRow(rowC).GetCell(4).SetCellValue("1");
             *      sheet1.GetRow(rowC).GetCell(5).SetCellValue(u.Price.ToString("0.00"));
             *      sheet1.GetRow(rowC).GetCell(6).SetCellValue(u.Price.ToString("0.00"));
             *
             *      sum += u.Price;
             *      rowC++;
             *  }
             * }*/

            sheet1.GetRow(19).GetCell(6).SetCellValue(sum.ToString("0.00"));
            sheet1.GetRow(20).GetCell(6).SetCellValue(Utilities.GetVAT(sum).ToString("0.00"));
            sheet1.GetRow(21).GetCell(6).SetCellValue((sum + Utilities.GetVAT(sum)).ToString("0.00"));

            sheet1.GetRow(49).GetCell(6).SetCellValue(sum.ToString("0.00"));
            sheet1.GetRow(50).GetCell(6).SetCellValue(Utilities.GetVAT(sum).ToString("0.00"));
            sheet1.GetRow(51).GetCell(6).SetCellValue((sum + Utilities.GetVAT(sum)).ToString("0.00"));

            /* sheet1.GetRow(2).GetCell(1).SetCellValue(300);
            *  sheet1.GetRow(3).GetCell(1).SetCellValue(500050);
            *  sheet1.GetRow(4).GetCell(1).SetCellValue(8000);
            *  sheet1.GetRow(5).GetCell(1).SetCellValue(110);
            *  sheet1.GetRow(6).GetCell(1).SetCellValue(100);
            *  sheet1.GetRow(7).GetCell(1).SetCellValue(200);
            *  sheet1.GetRow(8).GetCell(1).SetCellValue(210);
            *  sheet1.GetRow(9).GetCell(1).SetCellValue(2300);
            *  sheet1.GetRow(10).GetCell(1).SetCellValue(240);
            *  sheet1.GetRow(11).GetCell(1).SetCellValue(180123);
            *  sheet1.GetRow(12).GetCell(1).SetCellValue(150);*/

            //Force excel to recalculate all the formula while open
            sheet1.ForceFormulaRecalculation = true;

            WriteToFile();
        }