public void AddStandardBreakline(ObjectId SurfaceId, ObjectId polyId, string name)
 {
     using (Transaction tr = CivilApplicationManager.StartTransaction())
     {
         C3DLandDb.TinSurface surface  = SurfaceId.GetObject(OpenMode.ForRead) as C3DLandDb.TinSurface;
         ObjectIdCollection   entities = new ObjectIdCollection();
         entities.Add(polyId);
         surface.BreaklinesDefinition.AddStandardBreaklines(entities, 1.0, 1.0, 1.0, 0.0);
         tr.Commit();
     }
 }
Exemple #2
0
        DrillDown()
        {
            if (m_val.IsNull == false)
            {
                Autodesk.AutoCAD.DatabaseServices.ObjectIdCollection objIds = new Autodesk.AutoCAD.DatabaseServices.ObjectIdCollection();
                objIds.Add(m_val);

                using (TransactionHelper trHlp = new TransactionHelper(m_val.Database)) {
                    trHlp.Start();

                    Snoop.Forms.DBObjects form = new Snoop.Forms.DBObjects(objIds, trHlp);
                    form.ShowDialog();

                    trHlp.Commit();
                }
            }
        }
Exemple #3
0
        private void btnSelect_Click(object sender, EventArgs e)
        {
            Editor ed            = Autodesk.AutoCAD.ApplicationServices.Application.DocumentManager.MdiActiveDocument.Editor;
            Guid   StartPoleCode = Guid.Empty;

            Autodesk.AutoCAD.DatabaseServices.ObjectId _BranchOi = Autodesk.AutoCAD.DatabaseServices.ObjectId.Null;
            int _vol = 0;

            //gClamp.Visible = false;
            //gConsol.Visible = false;
            BranchesData.Clear();

            this.Hide();

            PromptSelectionOptions pso = new PromptSelectionOptions();

            pso.MessageForAdding = "Select Branches Please";

            //PromptEntityOptions PEO = new PromptEntityOptions(": \n");
            //PromptEntityResult PER = ed.GetEntity(PEO);
            PromptSelectionResult PSR = ed.GetSelection(pso);

            SelectdEntities.Clear();
            if (PSR.Status == PromptStatus.OK)
            {
                SelectionSet ss = PSR.Value;
                ////////if (ss.Count > 0)
                ////////{
                ////////    Atend.Base.Acad.AT_INFO SelectedBranchInfo = Atend.Base.Acad.AT_INFO.SelectBySelectedObjectId(ss[0].ObjectId);
                ////////    if (SelectedBranchInfo.NodeType == (int)Atend.Control.Enum.ProductType.Conductor)
                ////////    {
                ////////        IsConductor = true;
                ////////    }
                ////////    else
                ////////    {
                ////////        IsConductor = false;
                ////////    }
                ////////}
                //MessageBox.Show("NUmber of selected entity : " + ss.Count.ToString());
                foreach (SelectedObject so in ss)
                {
                    ConsolsOIs.Clear();
                    ClampsOIs.Clear();
                    Atend.Base.Acad.AT_INFO BranchInfo = Atend.Base.Acad.AT_INFO.SelectBySelectedObjectId(so.ObjectId);
                    if (BranchInfo.NodeType == (int)Atend.Control.Enum.ProductType.Conductor)
                    {
                        //MessageBox.Show("it was conductor");
                        //gConsol.Visible = true;
                        Atend.Base.Acad.AT_SUB BranchSub = Atend.Base.Acad.AT_SUB.SelectBySelectedObjectId(so.ObjectId);
                        foreach (Autodesk.AutoCAD.DatabaseServices.ObjectId oi in BranchSub.SubIdCollection)
                        {
                            Atend.Base.Acad.AT_INFO ConsolInfo = Atend.Base.Acad.AT_INFO.SelectBySelectedObjectId(oi);
                            if (ConsolInfo.NodeType == (int)Atend.Control.Enum.ProductType.Consol)
                            {
                                Atend.Base.Equipment.EConsol ConsolData = Atend.Base.Equipment.EConsol.AccessSelectByCode(ConsolInfo.ProductCode);
                                if (ConsolData.ConsolType == 0 || ConsolData.ConsolType == 1)
                                {
                                    ConsolsOIs.Add(oi);
                                    Autodesk.AutoCAD.DatabaseServices.Line BranchEntity = Atend.Global.Acad.UAcad.GetEntityByObjectID(so.ObjectId) as Autodesk.AutoCAD.DatabaseServices.Line;
                                    if (BranchEntity != null)
                                    {
                                        if (Atend.Global.Acad.UAcad.CenterOfEntity(Atend.Global.Acad.UAcad.GetEntityByObjectID(oi)) == BranchEntity.StartPoint)
                                        {
                                            StartPoleCode = new Guid(ConsolInfo.ParentCode);
                                            _BranchOi     = so.ObjectId;
                                            _vol          = ConsolData.VoltageLevel;
                                        }
                                    }
                                }
                            }
                        }
                    }
                    else if (BranchInfo.NodeType == (int)Atend.Control.Enum.ProductType.SelfKeeper)
                    {
                        //MessageBox.Show("it was self keeper");
                        //gClamp.Visible = true;
                        Atend.Base.Acad.AT_SUB BranchSub = Atend.Base.Acad.AT_SUB.SelectBySelectedObjectId(so.ObjectId);
                        foreach (Autodesk.AutoCAD.DatabaseServices.ObjectId oi in BranchSub.SubIdCollection)
                        {
                            Atend.Base.Acad.AT_INFO ClampInfo = Atend.Base.Acad.AT_INFO.SelectBySelectedObjectId(oi);
                            if (ClampInfo.NodeType == (int)Atend.Control.Enum.ProductType.Kalamp)
                            {
                                Atend.Base.Equipment.EClamp ClampData = Atend.Base.Equipment.EClamp.AccessSelectByCode(ClampInfo.ProductCode);
                                if (ClampData.Type != 5)
                                {
                                    ClampsOIs.Add(oi);
                                    Autodesk.AutoCAD.DatabaseServices.Line BranchEntity = Atend.Global.Acad.UAcad.GetEntityByObjectID(so.ObjectId) as Autodesk.AutoCAD.DatabaseServices.Line;
                                    if (BranchEntity != null)
                                    {
                                        if (Atend.Global.Acad.UAcad.CenterOfEntity(Atend.Global.Acad.UAcad.GetEntityByObjectID(oi)) == BranchEntity.StartPoint)
                                        {
                                            StartPoleCode = new Guid(ClampInfo.ParentCode);
                                            _BranchOi     = so.ObjectId;
                                            _vol          = ClampData.VoltageLevel;
                                        }
                                    }
                                }
                            }
                        }
                    }

                    if (ConsolsOIs.Count == 2 || ClampsOIs.Count == 2)
                    {
                        //if (IsConductor)
                        //{
                        //    if (BranchInfo.NodeType == (int)Atend.Control.Enum.ProductType.Conductor)
                        //    {
                        SelectdEntities.Add(Atend.Global.Acad.UAcad.GetEntityByObjectID(so.ObjectId));


                        DataRow NewDataRow = BranchesData.NewRow();
                        NewDataRow["BranchCode"] = BranchInfo.NodeCode;
                        NewDataRow["BranchType"] = Convert.ToInt32(BranchInfo.NodeType);
                        NewDataRow["BranchOI"]   = _BranchOi.ToString().Substring(1, _BranchOi.ToString().Length - 2);
                        //NewDataRow["IsSelected"] = true;
                        NewDataRow["Type"]     = (Convert.ToInt32(BranchInfo.NodeType) == (int)Atend.Control.Enum.ProductType.Conductor ? "سیم" : "کابل خودنگهدار");
                        NewDataRow["Voltage"]  = _vol;
                        NewDataRow["PoleCode"] = StartPoleCode;
                        BranchesData.Rows.Add(NewDataRow);

                        //int NewRowIndex = gvBranches.Rows.Add();
                        //gvBranches.Rows[NewRowIndex].Cells["BranchCode"].Value = BranchInfo.ProductCode;
                        //gvBranches.Rows[NewRowIndex].Cells["BranchType"].Value = Convert.ToInt32(BranchInfo.NodeType);
                        //gvBranches.Rows[NewRowIndex].Cells["BranchOI"].Value = _BranchOi.ToString().Substring(1, _BranchOi.ToString().Length - 2);
                        //gvBranches.Rows[NewRowIndex].Cells["IsSelected"].Value = true;
                        //gvBranches.Rows[NewRowIndex].Cells["Type"].Value = (Convert.ToInt32(BranchInfo.NodeType) == (int)Atend.Control.Enum.ProductType.Conductor ? "سیم" : "کابل خودنگهدار");
                        //gvBranches.Rows[NewRowIndex].Cells["Voltage"].Value = _vol;


                        //    }
                        //    gConsol.Visible = true;
                        //    gClamp.Visible = false;
                        //}
                        //else
                        //{
                        //    if (BranchInfo.NodeType == (int)Atend.Control.Enum.ProductType.SelfKeeper)
                        //    {
                        //        SelectdEntities.Add(Atend.Global.Acad.UAcad.GetEntityByObjectID(so.ObjectId));
                        //    }
                        //    gConsol.Visible = false;
                        //    gClamp.Visible = true;
                        //}
                    }
                } //end for
            }     // end if (PSR.Status == PromptStatus.OK)
            this.Show();
            DataView dv = new DataView(BranchesData);

            dv.RowFilter          = "BranchType=" + (cboBranchType.SelectedIndex == 0 ? (int)Atend.Control.Enum.ProductType.Conductor : (int)Atend.Control.Enum.ProductType.SelfKeeper);
            gvBranches.DataSource = dv;
            //MessageBox.Show("count:" + SelectdEntities.Count.ToString());
        }
Exemple #4
0
        public static CadObjId[] GetViewportObjects(long vportnumber)
        {
            string sql = "SELECT * FROM pentity WHERE vportnumber =@vportnumber;";
            Dictionary <string, object> parameters = new Dictionary <string, object>();

            parameters.Add("vportnumber", vportnumber);

            DataTable          dt = ExecuteQuery(sql, parameters);
            CadObjId           cadobjid;
            CadObjIdCollection cadobjidls;
            long   pobjid;
            int    i = 0;
            string arraystring;
            int    pc = dt.Rows.Count;

            string[] tokens;// = values.Split(',');
            long[]   myItems;
            if (dt.Rows.Count > 0)
            {
                cadobjidls = new CadObjIdCollection();

                arraystring = dt.Rows[0].Field <string>("mobjectid");
                tokens      = arraystring.Split(',');
                myItems     = Array.ConvertAll <string, long>(tokens, long.Parse);
                foreach (long lid in myItems)
                {
                    cadobjid = new CadObjId((IntPtr)lid);
                    cadobjidls.Add(cadobjid);
                }
                CadObjId[] cabids = new CadObjId[cadobjidls.Count];
                cadobjidls.CopyTo(cabids, 0);
                return(cabids);
            }
            else
            {
                return(null);
            }


            //string sql = "SELECT * FROM pentity WHERE vportnumber =@vportnumber;";
            //Dictionary<string, object> parameters = new Dictionary<string, object>();
            //parameters.Add("vportnumber", vportnumber);

            //DataTable dt = ExecuteQuery(sql, parameters);
            //CadObjId cadobjid;
            //CadObjIdCollection cadobjidls;
            //long pobjid,pid1;
            //int i = 0;
            //int pc = dt.Rows.Count;
            //if (dt.Rows.Count > 0)
            //{
            //    cadobjidls = new CadObjIdCollection();

            //    foreach (DataRow dr in dt.Rows)
            //    {
            //        pobjid = dr.Field<long>("mobjectid");
            //        cadobjid = new CadObjId((IntPtr)pobjid);
            //        cadobjidls.Add(cadobjid);
            //    }
            //    return cadobjidls;
            // // pobjid= dt.Rows[0].Field<long>("mobjectid");
            //  ///pid1 = dt.Rows[1].Field<long>("mobjectid");
            //}
            //else
            //return null;
        }