Example #1
0
 internal static void UpdateConfigForSqlDbFileUpgrade(ConfigFileUtils configFileUtils, Project project, IVsUpgradeLogger logger)
 {
     try
     {
         var configXmlDoc = configFileUtils.LoadConfig();
         if (configXmlDoc != null) // check config file exists
         {
             if (ConnectionManager.UpdateSqlDatabaseFileDataSourceInConnectionStrings(configXmlDoc))
             {
                 configFileUtils.SaveConfig(configXmlDoc);
             }
         }
     }
     catch (Exception ex)
     {
         // if there were errors above then do not try to change the files on disk - just log the message and return
         var errMsg = String.Format(
             CultureInfo.CurrentCulture, Resources.ErrorDuringSqlDatabaseFileUpgrade, configFileUtils.GetConfigPath(), ex.Message);
         logger.LogMessage((uint)__VSUL_ERRORLEVEL.VSUL_ERROR, project.Name, configFileUtils.GetConfigPath(), errMsg);
     }
 }
Example #2
0
        internal static void SqlCeUpgradeService_OnUpgradeProject(IVsHierarchy hierarchy, IVsUpgradeLogger logger)
        {
            if (PackageManager.Package != null
                && PackageManager.Package.ModelManager != null)
            {
                // since this is about retargeting EDMX files on disk, no need to process other file extensions from any converters
                var fileFinder = new VSFileFinder(EntityDesignArtifact.ExtensionEdmx);
                fileFinder.FindInProject(hierarchy);

                var project = VSHelpers.GetProject(hierarchy);

                // skip the step if it is a miscellaneous project.
                if (project != null
                    && !VsUtils.IsMiscellaneousProject(project))
                {
                    IDictionary<string, object> documentMap = new Dictionary<string, object>();
                    foreach (var vsFileInfo in fileFinder.MatchingFiles)
                    {
                        try
                        {
                            var projectItem = VsUtils.GetProjectItem(hierarchy, vsFileInfo.ItemId);

                            // Dev 10 bug 648969: skip the process for astoria edmx file.
                            if (EdmUtils.IsDataServicesEdmx(projectItem.get_FileNames(1)))
                            {
                                continue;
                            }

                            // Check whether project item is a linked item
                            var isLinkItem = VsUtils.IsLinkProjectItem(projectItem);

                            if (!isLinkItem)
                            {
                                var doc = MetadataConverterDriver.SqlCeInstance.Convert(SafeLoadXmlFromPath(vsFileInfo.Path));
                                if (doc != null)
                                {
                                    documentMap.Add(vsFileInfo.Path, doc);
                                }
                            }
                        }
                        catch (Exception ex)
                        {
                            var errMsg = String.Format(
                                CultureInfo.CurrentCulture, Resources.ErrorDuringSqlCeUpgrade, vsFileInfo.Path, ex.Message);
                            logger.LogMessage((uint)__VSUL_ERRORLEVEL.VSUL_ERROR, project.Name, vsFileInfo.Path, errMsg);
                            return;
                        }
                    }

                    if (documentMap.Count > 0)
                    {
                        VsUtils.WriteCheckoutXmlFilesInProject(documentMap);
                    }

                    // now update the config file as needed
                    var configFileUtils = new ConfigFileUtils(project, PackageManager.Package);
                    try
                    {
                        var configXmlDoc = configFileUtils.LoadConfig();
                        if (configXmlDoc != null) // check config file exists
                        {
                            if (ConnectionManager.UpdateSqlCeProviderInConnectionStrings(configXmlDoc))
                            {
                                configFileUtils.SaveConfig(configXmlDoc);
                            }
                        }
                    }
                    catch (Exception ex)
                    {
                        var errMsg = String.Format(
                            CultureInfo.CurrentCulture, Resources.ErrorDuringSqlCeUpgrade, configFileUtils.GetConfigPath(), ex.Message);
                        logger.LogMessage((uint)__VSUL_ERRORLEVEL.VSUL_ERROR, project.Name, configFileUtils.GetConfigPath(), errMsg);
                    }
                }
            }
        }