Example #1
0
        private const uint WDC3FmtSig = 0x33434457; // WDC3

        public static DB6Storage <T> Read <T>(string fileName, HotfixStatements preparedStatement, HotfixStatements preparedStatementLocale = 0) where T : new()
        {
            DB6Storage <T> storage = new DB6Storage <T>();

            if (!File.Exists(CliDB.DataPath + fileName))
            {
                Log.outError(LogFilter.ServerLoading, $"File {fileName} not found.");
                return(storage);
            }

            DBReader reader = new DBReader();

            using (var stream = new FileStream(CliDB.DataPath + fileName, FileMode.Open))
            {
                if (!reader.Load(stream))
                {
                    Log.outError(LogFilter.ServerLoading, $"Error loading {fileName}.");
                    return(storage);
                }
            }

            foreach (var b in reader._records)
            {
                storage.Add((uint)b.Key, b.Value.As <T>());
            }

            storage.LoadData(reader.Header.IdIndex, preparedStatement, preparedStatementLocale);

            Global.DB2Mgr.AddDB2(reader.Header.TableHash, storage);
            CliDB.LoadedFileCount++;
            return(storage);
        }
Example #2
0
        public static DB6Storage <T> Read <T>(string fileName, HotfixStatements preparedStatement, HotfixStatements preparedStatementLocale = 0) where T : new()
        {
            ClearData();

            DB6Storage <T> storage = new DB6Storage <T>();

            if (!File.Exists(CliDB.DataPath + fileName))
            {
                Log.outError(LogFilter.ServerLoading, "File {0} not found.", fileName);
                return(storage);
            }

            //First lets load field Info
            var fields = typeof(T).GetFields();

            DB6FieldInfo[] fieldsInfo = new DB6FieldInfo[fields.Length];
            for (var i = 0; i < fields.Length; ++i)
            {
                fieldsInfo[i] = new DB6FieldInfo(fields[i]);
            }

            using (var fileReader = new BinaryReader(new MemoryStream(File.ReadAllBytes(CliDB.DataPath + fileName))))
            {
                ReadHeader(fileReader);

                var records = ReadData(fileReader);
                foreach (var pair in records)
                {
                    using (MemoryStream ms = new MemoryStream(pair.Value))
                        using (BinaryReader dataReader = new BinaryReader(ms, System.Text.Encoding.UTF8))
                        {
                            var obj = new T();

                            int objectFieldIndex = 0;
                            //First check if index is in data
                            if (Header.HasIndexTable())
                            {
                                fieldsInfo[objectFieldIndex++].SetValue(obj, (uint)pair.Key);
                            }

                            for (var dataFieldIndex = 0; dataFieldIndex < Header.FieldCount; ++dataFieldIndex)
                            {
                                int arrayLength = ColumnMeta[dataFieldIndex].ArraySize;
                                if (arrayLength > 1)
                                {
                                    for (var arrayIndex = 0; arrayIndex < arrayLength; ++arrayIndex)
                                    {
                                        var fieldInfo = fieldsInfo[objectFieldIndex++];
                                        if (fieldInfo.IsArray)
                                        {
                                            Array array = (Array)fieldInfo.Getter(obj);
                                            SetArrayValue(obj, (uint)array.Length, fieldInfo, dataReader);

                                            arrayLength -= array.Length;
                                        }
                                        else
                                        {
                                            //Only Data is Array
                                            if (Type.GetTypeCode(fieldInfo.FieldType) == TypeCode.Object)
                                            {
                                                switch (fieldInfo.FieldType.Name)
                                                {
                                                case "Vector2":
                                                    fieldInfo.SetValue(obj, dataReader.Read <Vector2>());
                                                    arrayLength -= 2;
                                                    break;

                                                case "Vector3":
                                                    fieldInfo.SetValue(obj, dataReader.Read <Vector3>());
                                                    arrayLength -= 3;
                                                    break;

                                                case "LocalizedString":
                                                    LocalizedString locString = new LocalizedString();
                                                    locString[Global.WorldMgr.GetDefaultDbcLocale()] = GetString(dataReader);
                                                    fieldInfo.SetValue(obj, locString);
                                                    arrayLength -= 1;
                                                    break;

                                                case "FlagArray128":
                                                    fieldInfo.SetValue(obj, new FlagArray128(dataReader.ReadUInt32(), dataReader.ReadUInt32(), dataReader.ReadUInt32(), dataReader.ReadUInt32()));
                                                    arrayLength -= 4;
                                                    break;

                                                default:
                                                    Log.outError(LogFilter.ServerLoading, "Unknown Array Type {0} in DBClient File", fieldInfo.FieldType.Name, nameof(T));
                                                    break;
                                                }
                                            }
                                            else
                                            {
                                                SetValue(obj, fieldInfo, dataReader);
                                            }
                                        }

                                        dataReader.BaseStream.Position += GetPadding(fieldInfo.FieldType, dataFieldIndex);
                                    }
                                }
                                else
                                {
                                    var fieldInfo = fieldsInfo[objectFieldIndex++];
                                    if (fieldInfo.IsArray)
                                    {
                                        Array array = (Array)fieldInfo.Getter(obj);
                                        SetArrayValue(obj, (uint)array.Length, fieldInfo, dataReader);

                                        dataFieldIndex += array.Length - 1;
                                    }
                                    else
                                    {
                                        SetValue(obj, fieldInfo, dataReader);
                                    }

                                    dataReader.BaseStream.Position += GetPadding(fieldInfo.FieldType, dataFieldIndex);
                                }
                            }

                            //Check if there is parent ids and fill them
                            if (objectFieldIndex < fieldsInfo.Length && Header.LookupColumnCount > 0)
                            {
                                fieldsInfo[objectFieldIndex].SetValue(obj, dataReader.ReadUInt32());
                            }

                            storage.Add((uint)pair.Key, obj);
                        }
                }

                storage.LoadData(Header.IdIndex, fieldsInfo, preparedStatement, preparedStatementLocale);
            }

            Global.DB2Mgr.AddDB2(Header.TableHash, storage);
            CliDB.LoadedFileCount++;
            return(storage);
        }
Example #3
0
        internal static DB6Storage <T> Read <T>(string fileName, DB6Meta meta, HotfixStatements preparedStatement, HotfixStatements preparedStatementLocale = 0) where T : new()
        {
            DB6Storage <T> storage = new DB6Storage <T>();

            if (!File.Exists(CliDB.DataPath + fileName))
            {
                Log.outError(LogFilter.ServerLoading, "File {0} not found.", fileName);
                return(storage);
            }

            //First lets load field Info
            var fields = typeof(T).GetFields();

            DBClientHelper[] fieldsInfo = new DBClientHelper[fields.Length];
            for (var i = 0; i < fields.Length; ++i)
            {
                fieldsInfo[i] = new DBClientHelper(fields[i]);
            }

            using (var fileReader = new BinaryReader(new MemoryStream(File.ReadAllBytes(CliDB.DataPath + fileName))))
            {
                _header = ReadHeader(fileReader);
                var data = LoadData(fileReader);

                int commonDataFieldIndex = 0;
                foreach (var pair in data)
                {
                    var dataReader = new DB6BinaryReader(pair.Value);
                    var obj        = new T();

                    int fieldIndex = 0;
                    for (var x = 0; x < _header.FieldCount; ++x)
                    {
                        int arrayLength = meta.ArraySizes[x];
                        if (arrayLength > 1)
                        {
                            for (var z = 0; z < arrayLength; ++z)
                            {
                                var fieldInfo = fieldsInfo[fieldIndex++];
                                if (fieldInfo.IsArray)
                                {
                                    //Field is Array
                                    Array array = (Array)fieldInfo.Getter(obj);
                                    for (var y = 0; y < array.Length; ++y)
                                    {
                                        SetArrayValue(array, y, fieldInfo, dataReader, x);
                                    }

                                    arrayLength -= array.Length;
                                }
                                else
                                {
                                    //Only Data is Array
                                    if (Type.GetTypeCode(fieldInfo.FieldType) == TypeCode.Object)
                                    {
                                        switch (fieldInfo.FieldType.Name)
                                        {
                                        case "Vector2":
                                            fieldInfo.SetValue(obj, new Vector2(dataReader.ReadSingle(), dataReader.ReadSingle()));
                                            arrayLength -= 2;
                                            break;

                                        case "Vector3":
                                            fieldInfo.SetValue(obj, new Vector3(dataReader.ReadSingle(), dataReader.ReadSingle(), dataReader.ReadSingle()));
                                            arrayLength -= 3;
                                            break;

                                        case "LocalizedString":
                                            LocalizedString locString = new LocalizedString();
                                            locString[Global.WorldMgr.GetDefaultDbcLocale()] = GetString(dataReader, x);
                                            fieldInfo.SetValue(obj, locString);
                                            arrayLength -= 1;
                                            break;

                                        case "FlagArray128":
                                            FlagArray128 flagArray128 = new FlagArray128(dataReader.GetUInt32(_header.GetFieldBytes(x)), dataReader.GetUInt32(_header.GetFieldBytes(x)), dataReader.GetUInt32(_header.GetFieldBytes(x)), dataReader.GetUInt32(_header.GetFieldBytes(x)));
                                            fieldInfo.SetValue(obj, flagArray128);
                                            arrayLength -= 4;
                                            break;

                                        default:
                                            Log.outError(LogFilter.ServerLoading, "Unknown Array Type {0} in DBClient File", fieldInfo.FieldType.Name, nameof(T));
                                            break;
                                        }
                                    }
                                    else
                                    {
                                        SetValue(obj, fieldInfo, dataReader, x);
                                    }
                                }
                            }
                        }
                        else
                        {
                            var fieldInfo = fieldsInfo[fieldIndex++];
                            if (fieldInfo.IsArray)
                            {
                                Array array = (Array)fieldInfo.Getter(obj);
                                for (var y = 0; y < array.Length; ++y)
                                {
                                    SetArrayValue(array, y, fieldInfo, dataReader, x + y);
                                }

                                x += array.Length - 1;
                            }
                            else
                            {
                                SetValue(obj, fieldInfo, dataReader, x);
                            }
                        }
                    }

                    commonDataFieldIndex = fieldIndex;

                    storage.Add((uint)pair.Key, obj);
                }

                //Get DB field Index
                uint index = 0;
                for (uint i = 0; i < _header.FieldCount && i < _header.IndexField; ++i)
                {
                    index += meta.ArraySizes[i];
                }

                ReadCommonData(commonDataFieldIndex, storage, meta, fieldsInfo);
                storage.LoadData(index, fieldsInfo, preparedStatement, preparedStatementLocale);
            }

            Global.DB2Mgr.AddDB2(_header.TableHash, storage);
            CliDB.LoadedFileCount++;
            return(storage);
        }