public void load_lab06()
        {
            R_lab_061.Load(@"C:\Report\R_lab_06.rpt");
            crystalReportViewer1.ReportSource     = R_lab_061;
            crystalReportViewer1.SelectionFormula = "{t_result_main1.resultid} = '" + this.Tag.ToString() + "'";

            ClassSql a = new ClassSql();
            TextBox  txt_ForNo = new TextBox(); TextBox txt_RevNo = new TextBox();

            a.PutDataTOTextBox("SELECT * FROM tbl_formno WHERE cn = '1'", txt_ForNo, "Form");
            a.PutDataTOTextBox("SELECT * FROM tbl_formno WHERE cn = '1'", txt_RevNo, "Revision");
            TextObject FormNo = (TextObject)R_lab_061.ReportDefinition.ReportObjects["txt_formNo"];
            TextObject RevNo  = (TextObject)R_lab_061.ReportDefinition.ReportObjects["txt_RevNo"];

            FormNo.Text = txt_ForNo.Text;
            RevNo.Text  = txt_RevNo.Text;

            //R_lab_061.Refresh();
            crystalReportViewer1.RefreshReport();
            RemoveTab(crystalReportViewer1);
            wizard1.SelectedTab = tabPage1;
        }
 private void button1_Click(object sender, EventArgs e)
 {
     R_lab_061.PrintOptions.PrinterName = Tool.PrinterPath();
     R_lab_061.PrintToPrinter(1, false, 0, 0);
 }
        public void load_lab06()
        {
            IniFile ini = new IniFile(ClassSql.MMS_Path);



            R_lab_061.SetDatabaseLogon(ini.IniReadValue("CONNECTIONSTRING", "Uid"), ini.IniReadValue("CONNECTIONSTRING", "Pwd"), ini.IniReadValue("CONNECTIONSTRING", "Server"), ini.IniReadValue("CONNECTIONSTRING", "Database"));

            R_lab_061.Load(@"C:\Report\R_lab_06.rpt");
            Viewer_01.ReportSource     = R_lab_061;
            Viewer_01.SelectionFormula = "{t_result_main1.resultid} = '" + this.Tag.ToString() + "'";

            //ClassSql a = new ClassSql();
            //TextBox txt_ForNo = new TextBox(); TextBox txt_RevNo = new TextBox();
            //a.PutDataTOTextBox("SELECT * FROM tbl_formno WHERE cn = '1'", txt_ForNo, "Form");
            //a.PutDataTOTextBox("SELECT * FROM tbl_formno WHERE cn = '1'", txt_RevNo, "Revision");
            TextObject FormNo = (TextObject)R_lab_061.ReportDefinition.ReportObjects["txt_formNo"];
            TextObject RevNo  = (TextObject)R_lab_061.ReportDefinition.ReportObjects["txt_RevNo"];

            FormNo.Text = ini.IniReadValue("FORM", "Lab_06");
            RevNo.Text  = ini.IniReadValue("REVISION", "Lab_06");


            TextObject aa = (TextObject)R_lab_061.ReportDefinition.ReportObjects["Text134"];
            TextObject b  = (TextObject)R_lab_061.ReportDefinition.ReportObjects["Text133"];
            TextObject c  = (TextObject)R_lab_061.ReportDefinition.ReportObjects["Text125"];
            TextObject d  = (TextObject)R_lab_061.ReportDefinition.ReportObjects["Text98"];
            TextObject e  = (TextObject)R_lab_061.ReportDefinition.ReportObjects["Text97"];
            TextObject f  = (TextObject)R_lab_061.ReportDefinition.ReportObjects["Text96"];
            TextObject g  = (TextObject)R_lab_061.ReportDefinition.ReportObjects["Text95"];
            TextObject h  = (TextObject)R_lab_061.ReportDefinition.ReportObjects["Text144"];
            TextObject i  = (TextObject)R_lab_061.ReportDefinition.ReportObjects["Text143"];
            TextObject j  = (TextObject)R_lab_061.ReportDefinition.ReportObjects["Text142"];
            TextObject k  = (TextObject)R_lab_061.ReportDefinition.ReportObjects["Text141"];
            TextObject l  = (TextObject)R_lab_061.ReportDefinition.ReportObjects["Text140"];
            TextObject m  = (TextObject)R_lab_061.ReportDefinition.ReportObjects["Text139"];
            TextObject n  = (TextObject)R_lab_061.ReportDefinition.ReportObjects["Text145"];
            TextObject o  = (TextObject)R_lab_061.ReportDefinition.ReportObjects["Text146"];
            TextObject p  = (TextObject)R_lab_061.ReportDefinition.ReportObjects["Text147"];

            aa.Text = ini.IniReadValue("NormalValue", "hemoglobin") + "gm/dl";
            b.Text  = ini.IniReadValue("NormalValue", "hematocrit") + "vol%";
            c.Text  = ini.IniReadValue("NormalValue", "RBC") + " m/cumm";
            d.Text  = ini.IniReadValue("NormalValue", "WBC") + " /cumm";
            e.Text  = ini.IniReadValue("NormalValue", "Platelet") + "/cumm";
            f.Text  = ini.IniReadValue("NormalValue", "BloodType");
            g.Text  = ini.IniReadValue("NormalValue", "ESR") + "mm/hr(MALE)/" + ini.IniReadValue("NormalValue", "textBox1") + "mm/hr(FEMALE)";
            h.Text  = ini.IniReadValue("NormalValue", "Lympho") + "%";
            i.Text  = ini.IniReadValue("NormalValue", "Segmenters") + "%";
            j.Text  = ini.IniReadValue("NormalValue", "Easinophils") + "%";
            k.Text  = ini.IniReadValue("NormalValue", "MonoCytes") + "%";
            l.Text  = ini.IniReadValue("NormalValue", "Myelocytes");
            m.Text  = ini.IniReadValue("NormalValue", "Juveniles");
            n.Text  = ini.IniReadValue("NormalValue", "StabCells") + "%";
            o.Text  = ini.IniReadValue("NormalValue", "BasoPhils") + "%";
            p.Text  = ini.IniReadValue("NormalValue", "Hema_Other");


            //R_lab_061.Refresh();
            Viewer_01.RefreshReport();
            RemoveTab(Viewer_01);
            wizard1.SelectedTab = tabPage1;
        }