Example #1
0
        public static void Get_XAGL_WM2000DB_PowerMeter_Mock(ModbusRtuOverTcp client, RedisClient redisClient, string messageString)
        {
            var par = messageString.FromJson <ControlRequest>();

            try
            {
                var powerMeter = new IotDataOilWellPowerMeter()
                {
                    AlarmCode = 0,
                    AlarmMsg  = "正常"
                };

                powerMeter.WellId       = par.DeviceId;
                powerMeter.DeviceTypeId = par.DeviceTypeId;
                powerMeter.DateTime     = DateTime.Now;
                powerMeter.Mock         = par.UseMockData;

                redisClient.AddItemToList("YCIOT:IOT_Data_OilWell_PowerMeter", powerMeter.ToJson().IndentJson());
                redisClient.Set($"Group:OilWell:{par.DeviceName}-{par.DeviceId}:PowerMeter", powerMeter);
                redisClient.Set($"Single:OilWell:PowerMeter:{par.DeviceName}-{par.DeviceId}", powerMeter);
            }
            catch (Exception ex)
            {
                Logger.Error(ex.Message);
                Logger.Error(ex.StackTrace);
                Logger.Error(ex.Source);

                if (!par.UserName.IsNullOrEmpty())
                {
                    ServerEventHelper.SendSseMessage(par.UserName, par.SessionId, -1, ex.Message);
                }
            }
        }
Example #2
0
        public static async Task Get_XAGL_WM1000DB_PowerMeter(ModbusRtuOverTcp client, RedisClient redisClient, string messageString)
        {
            var par = messageString.FromJson <ControlRequest>();

            try
            {
                var powerMeter = new IotDataOilWellPowerMeter()
                {
                    AlarmCode = 0,
                    AlarmMsg  = "正常"
                };

                var logIotModbusPoll = par.ConvertTo <LogIotModbusPoll>();

                var modbusAddress = par.ModbusAddress;

                ClientInfo.CurrentModbusPoolAddress = modbusAddress;

                powerMeter.DateTime = DateTime.Now;
                powerMeter.WellId   = par.DeviceId;

                powerMeter.DeviceTypeId = par.DeviceTypeId;
                powerMeter.Mock         = false;

                var flag = true;

                lock (ClientInfo.locker)
                {
                    ClientInfo.RequestTime     = DateTime.Now;
                    ClientInfo.ExpectedType    = 0x03;
                    ClientInfo.ExpectedDataLen = 2;
                }
                var read = await client.ReadAsync($"s={par.ModbusAddress};x=3;4117", 1);

                if (read.IsSuccess)
                {
                    var value = client.ByteTransform.TransInt16(read.Content, 0);
                    if (value == 0)
                    {
                        powerMeter.NetworkNode = ClientInfo.ManyIpAddress;
                        powerMeter.AlarmCode   = 3;
                        powerMeter.AlarmMsg    = "停井";
                    }
                }
                else
                {
                }
                lock (ClientInfo.locker)
                {
                    ClientInfo.RequestTime     = DateTime.Now;
                    ClientInfo.ExpectedType    = 0x03;
                    ClientInfo.ExpectedDataLen = 9 * 2;
                }
                read = await client.ReadAsync($"s={par.ModbusAddress};x=3;4096", 9);

                if (read.IsSuccess)
                {
                    // A相电压  4097  变比 0.1
                    var value = client.ByteTransform.TransInt16(read.Content, 0);
                    powerMeter.APhaseVoltage = Math.Round(value * 0.1, 1);

                    // B相电压  4098  变比 0.1
                    value = client.ByteTransform.TransInt16(read.Content, 2);
                    powerMeter.BPhaseVoltage = Math.Round(value * 0.1, 1);

                    // C相电压  4099  变比 0.1
                    value = client.ByteTransform.TransInt16(read.Content, 4);
                    powerMeter.CPhaseVoltage = Math.Round(value * 0.1, 1);

                    // A相电流  4100  变比 0.001
                    value = client.ByteTransform.TransInt16(read.Content, 6);
                    powerMeter.APhaseCurrent = Math.Round(value * 0.001, 1);

                    // B相电流   4101  变比 0.001
                    value = client.ByteTransform.TransInt16(read.Content, 8);
                    powerMeter.BPhaseCurrent = Math.Round(value * 0.001, 1);

                    // C相电流   4102  变比 0.001
                    value = client.ByteTransform.TransInt16(read.Content, 10);
                    powerMeter.CPhaseCurrent = Math.Round(value * 0.001, 1);

                    //有功电能
                    var value1 = client.ByteTransform.TransInt16(read.Content, 12);
                    var value2 = client.ByteTransform.TransInt16(read.Content, 14);
                    powerMeter.TotalActiveEnergy = Math.Round((value1 * 65535 + value2) * 0.15, 3);

                    //总功率因素  4105  变比 1
                    value = client.ByteTransform.TransInt16(read.Content, 16);
                    powerMeter.TotalPowerFactor = Math.Round(value * 0.001, 1);
                }
                else
                {
                    flag = false;
                    powerMeter.AlarmCode = -1;
                    powerMeter.AlarmMsg  = "数据异常";

                    powerMeter.Mock           = par.UseMockData;
                    logIotModbusPoll.DateTime = DateTime.Now;
                    logIotModbusPoll.State    = -1;
                    logIotModbusPoll.Result   = "读取电参数据异常!";

                    redisClient.AddItemToList("YCIOT:ERROR:Log_IOT_Modbus_Poll", logIotModbusPoll.ToJson().IndentJson());
                }

                powerMeter.NetworkNode = ClientInfo.ManyIpAddress;

                //用于将读取的结果写入Redis队列
                if (flag == true || par.UseMockData)
                {
                    powerMeter.Mock = par.UseMockData;

                    redisClient.AddItemToList("YCIOT:IOT_Data_OilWell_PowerMeter", powerMeter.ToJson().IndentJson());
                    redisClient.Set($"Group:OilWell:{par.DeviceName}-{par.DeviceId}:PowerMeter", powerMeter);
                    redisClient.Set($"Single:OilWell:PowerMeter:{par.DeviceName}-{par.DeviceId}", powerMeter);
                }

                //用于通过ServerEvent给调用着返回消息
                if (!par.UserName.IsNullOrEmpty())
                {
                    ServerEventHelper.SendSseMessage(par.UserName, par.SessionId, flag ? 0 : -2, powerMeter.ToJson().IndentJson());
                }
            }
            catch (Exception ex)
            {
                Logger.Error(ex.Message);
                Logger.Error(ex.StackTrace);
                Logger.Error(ex.Source);

                if (!par.UserName.IsNullOrEmpty())
                {
                    ServerEventHelper.SendSseMessage(par.UserName, par.SessionId, -1, ex.Message);
                }
            }

            //
        }
Example #3
0
        /// <summary>
        /// 读取电表数据
        /// </summary>
        /// <param name="client"></param>
        /// <param name="redisClient"></param>
        /// <param name="messageString"></param>
        /// <returns></returns>
        public static async Task Get_XAGL_WM2000DB_PowerMeter(ModbusRtuOverTcp client, RedisClient redisClient, string messageString)
        {
            var par = messageString.FromJson <ControlRequest>();

            try
            {
                var powerMeter = new IotDataOilWellPowerMeter()
                {
                    AlarmCode = 0,
                    AlarmMsg  = "正常"
                };

                var logIotModbusPoll = par.ConvertTo <LogIotModbusPoll>();

                var modbusAddress = par.ModbusAddress;

                ClientInfo.CurrentModbusPoolAddress = modbusAddress;
                ClientInfo.LinkId = par.LinkId;

                powerMeter.DateTime = DateTime.Now;
                powerMeter.WellId   = par.DeviceId;

                powerMeter.DeviceTypeId = par.DeviceTypeId;
                powerMeter.Mock         = false;

                var flag = true;

                #region  判断井状态

                lock (ClientInfo.locker)
                {
                    ClientInfo.RequestTime     = DateTime.Now;
                    ClientInfo.ExpectedType    = 0x03;
                    ClientInfo.ExpectedDataLen = 2;
                }

                var read = await client.ReadAsync($"s={par.ModbusAddress};x=3;4103", 1);

                if (read.IsSuccess)
                {
                    var value = client.ByteTransform.TransInt16(read.Content, 0);

                    if (value == 3)  //1:正转运行;3:变频停机
                    {
                        powerMeter.NetworkNode = ClientInfo.ManyIpAddress;
                        powerMeter.AlarmCode   = 3;
                        powerMeter.AlarmMsg    = "停井";
                    }
                }
                else
                {
                    flag = false;
                    powerMeter.AlarmCode = -1;
                    powerMeter.AlarmMsg  = "数据异常";

                    powerMeter.Mock           = par.UseMockData;
                    logIotModbusPoll.DateTime = DateTime.Now;
                    logIotModbusPoll.State    = -1;
                    logIotModbusPoll.Result   = $"读取电参井状态数据异常![{read.Message}]";
                    $"DB:{par.DeviceName}-{par.DeviceId}{logIotModbusPoll.Result}".Info();

                    redisClient.AddItemToList("YCIOT:ERROR:Log_IOT_Modbus_Poll", logIotModbusPoll.ToJson().IndentJson());
                }
                #endregion

                if (flag)
                {
                    lock (ClientInfo.locker)
                    {
                        ClientInfo.RequestTime     = DateTime.Now;
                        ClientInfo.ExpectedType    = 0x03;
                        ClientInfo.ExpectedDataLen = 18;
                    }

                    read = await client.ReadAsync($"s={par.ModbusAddress};x=3;4121", 7);

                    if (read.IsSuccess)
                    {
                        // A相电流  4121  变比 0.01
                        var value = client.ByteTransform.TransInt16(read.Content, 0);
                        powerMeter.APhaseCurrent = Math.Round(value * 0.01, 1);

                        // B相电流   4122  变比 0.01
                        value = client.ByteTransform.TransInt16(read.Content, 2);
                        powerMeter.BPhaseCurrent = Math.Round(value * 0.01, 1);

                        // C相电流   4123  变比 0.01
                        value = client.ByteTransform.TransInt16(read.Content, 4);
                        powerMeter.CPhaseCurrent = Math.Round(value * 0.01, 1);

                        // 总功率因素  4124  变比 0.001
                        value = client.ByteTransform.TransInt16(read.Content, 6);
                        powerMeter.TotalPowerFactor = Math.Round(value * 0.001, 1);

                        // A相电压  4125  变比 0.1
                        value = client.ByteTransform.TransInt16(read.Content, 8);
                        powerMeter.APhaseVoltage = Math.Round(value * 0.1, 1);

                        // B相电压  4126  变比 0.1
                        value = client.ByteTransform.TransInt16(read.Content, 10);
                        powerMeter.BPhaseVoltage = Math.Round(value * 0.1, 1);

                        // C相电压  4127  变比 0.1
                        value = client.ByteTransform.TransInt16(read.Content, 12);
                        powerMeter.CPhaseVoltage = Math.Round(value * 0.1, 1);
                    }
                    else
                    {
                        flag = false;
                        powerMeter.AlarmCode = -1;
                        powerMeter.AlarmMsg  = "数据异常";

                        powerMeter.Mock           = par.UseMockData;
                        logIotModbusPoll.DateTime = DateTime.Now;
                        logIotModbusPoll.State    = -1;
                        logIotModbusPoll.Result   = $"读取电参数据异常![{read.Message}]";

                        redisClient.AddItemToList("YCIOT:ERROR:Log_IOT_Modbus_Poll", logIotModbusPoll.ToJson().IndentJson());
                    }
                }

                if (flag)
                {
                    lock (ClientInfo.locker)
                    {
                        ClientInfo.RequestTime     = DateTime.Now;
                        ClientInfo.ExpectedType    = 0x03;
                        ClientInfo.ExpectedDataLen = 8;
                    }
                    read = await client.ReadAsync($"s={par.ModbusAddress};x=3;4141", 4);

                    if (read.IsSuccess)
                    {
                        var value0 = client.ByteTransform.TransInt16(read.Content, 0);
                        var value1 = client.ByteTransform.TransInt16(read.Content, 2);
                        var value2 = client.ByteTransform.TransInt16(read.Content, 4);
                        var value3 = client.ByteTransform.TransInt16(read.Content, 6);
                        //这是总有功电能
                        powerMeter.TotalActivePower = Math.Round(((value1 * 10000 + value0) * 0.001) * 15, 2);
                        //这是总无功电能
                        powerMeter.TotalReactivePower = Math.Round(((value3 * 10000 + value2) * 0.001) * 15, 2);
                    }
                    else
                    {
                        flag = false;

                        powerMeter.AlarmCode = -1;
                        powerMeter.AlarmMsg  = "数据异常";

                        powerMeter.Mock           = par.UseMockData;
                        logIotModbusPoll.DateTime = DateTime.Now;
                        logIotModbusPoll.State    = -1;
                        logIotModbusPoll.Result   = $"读取总有功电能数据异常![{read.Message}]";

                        redisClient.AddItemToList("YCIOT:ERROR:Log_IOT_Modbus_Poll", logIotModbusPoll.ToJson().IndentJson());
                    }
                }
                powerMeter.NetworkNode = ClientInfo.ManyIpAddress;

                if (flag == true || par.UseMockData)
                {
                    $"DB:{par.DeviceName}-{par.DeviceId}已获取到数据".Info();
                    powerMeter.Mock = par.UseMockData;
                    redisClient.AddItemToList("YCIOT:IOT_Data_OilWell_PowerMeter", powerMeter.ToJson().IndentJson());
                    redisClient.Set($"Group:OilWell:{par.DeviceName}-{par.DeviceId}:PowerMeter", powerMeter);
                    redisClient.Set($"Single:OilWell:PowerMeter:{par.DeviceName}-{par.DeviceId}", powerMeter);
                }

                if (!par.UserName.IsNullOrEmpty())
                {
                    ServerEventHelper.SendSseMessage(par.UserName, par.SessionId, flag ? 0 : -2, powerMeter.ToJson().IndentJson());
                }
            }
            catch (Exception ex)
            {
                Logger.Error(ex.Message);
                Logger.Error(ex.StackTrace);
                Logger.Error(ex.Source);

                if (!par.UserName.IsNullOrEmpty())
                {
                    ServerEventHelper.SendSseMessage(par.UserName, par.SessionId, -1, ex.Message);
                }
            }
        }
Example #4
0
        public static async Task Get_LYQH_DB_PowerMeter(ModbusRtuOverTcp client, RedisClient redisClient, string messageString)
        {
            var par = messageString.FromJson <ControlRequest>();

            try
            {
                var powerMeter = new IotDataOilWellPowerMeter()
                {
                    AlarmCode = 0,
                    AlarmMsg  = "正常"
                };

                var logIotModbusPoll = par.ConvertTo <LogIotModbusPoll>();

                var modbusAddress = par.ModbusAddress;

                var jo1    = (JObject)JsonConvert.DeserializeObject(par.CommandParameter);
                var slotId = Convert.ToInt32(jo1["1"].ToString());
                ClientInfo.CurrentModbusPoolAddress = modbusAddress;

                powerMeter.DateTime = DateTime.Now;
                powerMeter.WellId   = par.DeviceId;

                powerMeter.DeviceTypeId = par.DeviceTypeId;
                powerMeter.Mock         = false;

                var startAddress = (ushort)((slotId * 0x3000) + 1606);

                var flag = true;

                var isSuccess = await GetPowerMeter(client, modbusAddress, powerMeter, startAddress, 9, 3);

                if (!isSuccess)
                {
                    flag = false;
                    FailLog.Write(redisClient, par, powerMeter, logIotModbusPoll, "Get_LYQH_DB_PowerMeter", "读取电参数据异常!");
                }

                if (flag)
                {
                    //常规时间
                    startAddress = (ushort)((slotId * 0x3000) + 1615);
                    isSuccess    = await GetDateTime(client, modbusAddress, powerMeter, startAddress, 3, 3);

                    if (!isSuccess)
                    {
                        FailLog.Write(redisClient, par, powerMeter, logIotModbusPoll, "Get_LYQH_DB_PowerMeter", "读取常规时间数据异常!");
                    }
                }

                powerMeter.NetworkNode = ClientInfo.ManyIpAddress;

                //用于将读取的结果写入Redis队列
                if (isSuccess || par.UseMockData)
                {
                    powerMeter.Mock = par.UseMockData;
                    redisClient.AddItemToList("YCIOT:IOT_Data_OilWell_PowerMeter", powerMeter.ToJson().IndentJson());
                    redisClient.Set($"Group:OilWell:{par.DeviceName}-{par.DeviceId}:PowerMeter", powerMeter);
                    redisClient.Set($"Single:OilWell:PowerMeter:{par.DeviceName}-{par.DeviceId}", powerMeter);
                }

                //用于通过ServerEvent给调用着返回消息
                if (!par.UserName.IsNullOrEmpty())
                {
                    ServerEventHelper.SendSseMessage(par.UserName, par.SessionId, !isSuccess ? -2 : 0, powerMeter.ToJson().IndentJson());
                }
            }
            catch (Exception ex)
            {
                Logger.Error(ex.Message);
                Logger.Error(ex.StackTrace);
                Logger.Error(ex.Source);

                if (!par.UserName.IsNullOrEmpty())
                {
                    ServerEventHelper.SendSseMessage(par.UserName, par.SessionId, -1, ex.Message);
                }
            }
        }
Example #5
0
        /// <summary>
        /// 读取电表数据
        /// </summary>
        /// <param name="client"></param>
        /// <param name="redisClient"></param>
        /// <param name="messageString"></param>
        /// <returns></returns>
        public static async Task Get_XAAS_WII_PowerMeter(ModbusRtuOverTcp client, RedisClient redisClient, string messageString)
        {
            var par = messageString.FromJson <ControlRequest>();

            try
            {
                var powerMeter = new IotDataOilWellPowerMeter()
                {
                    AlarmCode = 0,
                    AlarmMsg  = "正常"
                };

                var logIotModbusPoll = par.ConvertTo <LogIotModbusPoll>();

                var modbusAddress = par.ModbusAddress;

                ClientInfo.CurrentModbusPoolAddress = modbusAddress;
                ClientInfo.LinkId = par.LinkId;

                powerMeter.DateTime = DateTime.Now;
                powerMeter.WellId   = par.DeviceId;

                powerMeter.DeviceTypeId = par.DeviceTypeId;
                powerMeter.Mock         = false;

                var flag = true;

                lock (ClientInfo.locker)
                {
                    ClientInfo.RequestTime     = DateTime.Now;
                    ClientInfo.ExpectedType    = 0x03;
                    ClientInfo.ExpectedDataLen = 2;
                }
                var read = await client.ReadAsync($"s={par.ModbusAddress};x=3;40532", 1);

                if (read.IsSuccess)
                {
                    var value = client.ByteTransform.TransInt16(read.Content, 0);
                    if (value == 1)
                    {
                        powerMeter.NetworkNode = ClientInfo.ManyIpAddress;

                        powerMeter.AlarmCode = 3;
                        powerMeter.AlarmMsg  = "停井";
                    }
                }
                else
                {
                    flag = false;
                    powerMeter.AlarmCode = -1;
                    powerMeter.AlarmMsg  = "数据异常";

                    powerMeter.Mock           = par.UseMockData;
                    logIotModbusPoll.DateTime = DateTime.Now;
                    logIotModbusPoll.State    = -1;
                    logIotModbusPoll.Result   = $"读取电参数据异常![{read.Message}]";
                    $"DB:{par.DeviceName}-{par.DeviceId}{logIotModbusPoll.Result}".Info();

                    redisClient.AddItemToList("YCIOT:ERROR:Log_IOT_Modbus_Poll", logIotModbusPoll.ToJson().IndentJson());
                }


                if (flag)
                {
                    lock (ClientInfo.locker)
                    {
                        ClientInfo.RequestTime     = DateTime.Now;
                        ClientInfo.ExpectedType    = 0x03;
                        ClientInfo.ExpectedDataLen = 30;
                    }

                    read = await client.ReadAsync($"s={par.ModbusAddress};x=3;40533", 15);

                    if (read.IsSuccess)
                    {
                        // A相电流  40533  变比 0.01
                        var value = client.ByteTransform.TransInt16(read.Content, 0);
                        powerMeter.APhaseCurrent = Math.Round(value * 0.01, 1);

                        // B相电流   40534  变比 0.01
                        value = client.ByteTransform.TransInt16(read.Content, 2);
                        powerMeter.BPhaseCurrent = Math.Round(value * 0.01, 1);

                        // C相电流   40535  变比 0.01
                        value = client.ByteTransform.TransInt16(read.Content, 4);
                        powerMeter.CPhaseCurrent = Math.Round(value * 0.01, 1);

                        // A相电压  40536  变比 0.1
                        value = client.ByteTransform.TransInt16(read.Content, 6);
                        powerMeter.APhaseVoltage = Math.Round(value * 0.1, 1);

                        // B相电压  40537  变比 0.1
                        value = client.ByteTransform.TransInt16(read.Content, 8);
                        powerMeter.BPhaseVoltage = Math.Round(value * 0.1, 1);


                        // C相电压  40538  变比 0.1
                        value = client.ByteTransform.TransInt16(read.Content, 10);
                        powerMeter.CPhaseVoltage = Math.Round(value * 0.1, 1);


                        // 总有功功率  40539  变比0.01
                        value = client.ByteTransform.TransInt16(read.Content, 12);
                        powerMeter.TotalActivePower = Math.Round(value * 0.01, 1);

                        // 总无功功率  40540  变比0.01
                        value = client.ByteTransform.TransInt16(read.Content, 14);
                        powerMeter.TotalReactivePower = Math.Round(value * 0.01, 1);

                        //总视在功率  40541  变比0.01
                        value = client.ByteTransform.TransInt16(read.Content, 16);
                        powerMeter.TotalApparentPower = Math.Round(value * 0.01, 1);

                        // 总功率因素(功率因数) 40547  变比 0.01
                        value = client.ByteTransform.TransInt16(read.Content, 28);
                        powerMeter.TotalPowerFactor = Math.Round(value * 0.01, 1);
                    }
                    else
                    {
                        flag = false;
                        powerMeter.AlarmCode = -1;
                        powerMeter.AlarmMsg  = "数据异常";

                        powerMeter.Mock           = par.UseMockData;
                        logIotModbusPoll.DateTime = DateTime.Now;
                        logIotModbusPoll.State    = -1;
                        logIotModbusPoll.Result   = $"读取电参数据异常![{read.Message}]";

                        redisClient.AddItemToList("YCIOT:ERROR:Log_IOT_Modbus_Poll", logIotModbusPoll.ToJson().IndentJson());
                    }
                }

                if (flag)
                {
                    lock (ClientInfo.locker)
                    {
                        ClientInfo.RequestTime     = DateTime.Now;
                        ClientInfo.ExpectedType    = 0x03;
                        ClientInfo.ExpectedDataLen = 8;
                    }
                    read = await client.ReadAsync($"s={par.ModbusAddress};x=3;40543", 4);

                    if (read.IsSuccess)
                    {
                        var value0 = client.ByteTransform.TransInt16(read.Content, 0);
                        var value1 = client.ByteTransform.TransInt16(read.Content, 2);
                        var value2 = client.ByteTransform.TransInt16(read.Content, 4);
                        var value3 = client.ByteTransform.TransInt16(read.Content, 6);
                        //总有功电能
                        powerMeter.TotalActiveEnergy = Math.Round(((value1 * 65536 + value0) * 0.01), 2);
                        //电参模型中缺少总无功电能
                        //powerMeter.TotalReactivePower = Math.Round(((value3 * 65536 + value2) * 0.01), 2);
                    }
                    else
                    {
                        flag = false;

                        powerMeter.AlarmCode = -1;
                        powerMeter.AlarmMsg  = "数据异常";

                        powerMeter.Mock           = par.UseMockData;
                        logIotModbusPoll.DateTime = DateTime.Now;
                        logIotModbusPoll.State    = -1;
                        logIotModbusPoll.Result   = $"读取总有功电能数据异常![{read.Message}]";

                        redisClient.AddItemToList("YCIOT:ERROR:Log_IOT_Modbus_Poll", logIotModbusPoll.ToJson().IndentJson());
                    }
                }
                powerMeter.NetworkNode = ClientInfo.ManyIpAddress;

                //用于将读取的结果写入Redis队列
                if (flag == true || par.UseMockData)
                {
                    $"DB:{par.DeviceName}-{par.DeviceId}已获取到数据".Info();
                    powerMeter.Mock = par.UseMockData;
                    redisClient.AddItemToList("YCIOT:IOT_Data_OilWell_PowerMeter", powerMeter.ToJson().IndentJson());
                    redisClient.Set($"Group:OilWell:{par.DeviceName}-{par.DeviceId}:PowerMeter", powerMeter);
                    redisClient.Set($"Single:OilWell:PowerMeter:{par.DeviceName}-{par.DeviceId}", powerMeter);
                }

                //用于通过ServerEvent给调用着返回消息
                if (!par.UserName.IsNullOrEmpty())
                {
                    ServerEventHelper.SendSseMessage(par.UserName, par.SessionId, flag ? 0 : -2, powerMeter.ToJson().IndentJson());
                }
            }
            catch (Exception ex)
            {
                Logger.Error(ex.Message);
                Logger.Error(ex.StackTrace);
                Logger.Error(ex.Source);

                if (!par.UserName.IsNullOrEmpty())
                {
                    ServerEventHelper.SendSseMessage(par.UserName, par.SessionId, -1, ex.Message);
                }
            }
        }