        /// <summary>
        /// Gets the device information from the meter.
        /// </summary>
        //  Revision History
        //  MM/DD/YY Who Version ID Number Description
        //  -------- --- ------- -- ------ -------------------------------------------
        //  08/28/09 RCG 2.30.00           Created
        //  09/19/14 jrf 4.00.63 WR 534158 Modified to use the CANSIDevice.CreateDevice()
        //                                 method to instantiate the correct device and switched
        //                                 to store the name of the meter instead of device class.
        //  10/31/14 jrf 4.00.82  WR 542694 Added support for identifying Bridge meter with signed authorizaion.
        private TestRun GetDeviceInfo()
        {
            CXMLOpenWaySystemSettings SystemSettings = new CXMLOpenWaySystemSettings("");
            CPSEM        PSEM       = new CPSEM(m_Comm);
            PSEMResponse Response   = PSEMResponse.Ok;
            string       strModel   = null;
            TestRun      NewTestRun = new TestRun();
            string       MeterType  = "";

            Response = PSEM.Identify();

            if (Response == PSEMResponse.Ok)
            {
                Response = PSEM.Negotiate(CPSEM.DEFAULT_MAX_PACKET_LEGNTH,
                                          CPSEM.DEFAULT_MAX_NUMBER_OF_PACKETS, m_uiBaudRate);
            }

            if (Response == PSEMResponse.Ok)
            {
                Response = PSEM.Logon("", CPSEM.DEFAULT_HH_PRO_USER_ID);
            }

            if (Response == PSEMResponse.Ok)
            {
                CTable00 Table0 = new CTable00(PSEM);
                CTable01 Table1 = new CTable01(PSEM, Table0.StdVersion);
                strModel = Table1.Model;

                if (strModel == AMI_CENT)
                {
                    CANSIDevice ANSIDevice = CANSIDevice.CreateDevice(m_Comm, PSEM, Settings.Default.AuthenticationKey);
                    CENTRON_AMI AMIDevice  = ANSIDevice as CENTRON_AMI;

                    if (null != AMIDevice)
                    {
                        if (SystemSettings.UseSignedAuthorization && AMIDevice.SignedAuthorizationState != null &&
                            AMIDevice.SignedAuthorizationState.Value != FeatureState.Disabled &&
                            Settings.Default.AuthenticationKey != null)
                        {
                            // Use Signed Authenticaiton
                            AMIDevice.Authenticate(Settings.Default.AuthenticationKey);
                        }
                        else
                        {
                            // Use standard security
                            AMIDevice.Security(GetPasswords());
                        }

                        MeterType = AMIDevice.MeterName;

                        if (AMIDevice.CommModule != null)
                        {
                            m_strMeterID = AMIDevice.CommModule.ElectronicSerialNumber;
                        }
                    }
                }
            }

            try
            {
                PSEM.Logoff();
                PSEM.Terminate();
            }
            catch (Exception)
            {
                // Make sure we log off.
            }

            // Handle any errors that may have occurred
            if (Response != PSEMResponse.Ok)
            {
                throw new PSEMException(PSEMException.PSEMCommands.PSEM_READ, Response, Resources.ErrorRetrievingDeviceIdentification);
            }
            else if (strModel != AMI_CENT)
            {
                throw new InvalidOperationException(Resources.MeterTypeNotSupported);
            }

            // Set up the TestRun results
            NewTestRun.MeterType   = MeterType;
            NewTestRun.MeterID     = m_strMeterID;
            NewTestRun.TestDate    = DateTime.Now;
            NewTestRun.ProgramName = m_strProgramFile;
            NewTestRun.SWVersion   = Application.ProductVersion;

            return(NewTestRun);
        }
Example #2
0
        /// <summary>
        /// Connects to the meter using ZigBee
        /// </summary>
        //  Revision History
        //  MM/DD/YY Who Version Issue# Description
        //  -------- --- ------- ------ -------------------------------------------
        //  09/17/09 RCG 2.30.00        Created
        //  10/31/14 jrf 4.00.82  WR 542694 Added support for identifying Bridge meter with signed authorizaion.
        //  01/27/15 jrf 4.01.01 WR 557786 Adding ability for test to logon to meter using signed authorization.
        //  02/10/17 jrf 4.72.00 WR 645582 Adding try/catch around final logoff and close port.
        private bool LogonViaZigBee(ZigBeeRadioToken radioToken)
        {
            Radio        ZigBeeRadio  = CreateZigBeeRadio(radioToken);
            CPSEM        ZigBeePSEM   = null;
            CENTRON_AMI  ZigBeeDevice = null;
            bool         bCouldLogon  = false;
            PSEMResponse Response;

            if (ZigBeeRadio != null)
            {
                ZigbeeResult ZBResult = ZigbeeResult.NOT_CONNECTED;
                ZigBeeRadio.OpenPort(radioToken.RadioIdentifier);

                if (ZigBeeRadio.IsOpen)
                {
                    int counter = 0;

                    while ((ZigbeeResult.SUCCESS != ZBResult) && (counter < 4))
                    {
                        try
                        {
                            ZBResult = ZigBeeRadio.Start(Radio.C177_HANDHELD_PROGRAMMER_MAC,
                                                         m_ulMACAddress, ZigbeeLogicalType.ENDDEVICE, m_byChannel);
                        }
                        catch
                        {
                            Thread.Sleep(5000);
                        }
                        counter++;
                    }
                }

                if (!ZigBeeRadio.IsOpen ||
                    ZBResult != ZigbeeResult.SUCCESS)
                {
                    // Make sure the radio is disconnected.
                    ZigBeeRadio.ClosePort();
                    ZigBeeRadio = null;
                }
                else
                {
                    try
                    {
                        // Logon to the meter
                        ZigBeePSEM = new CPSEM(ZigBeeRadio);

                        Response = ZigBeePSEM.Identify();

                        if (Response != PSEMResponse.Ok)
                        {
                            // Retry the identify in case the meter is in a bad state
                            Response = ZigBeePSEM.Identify();
                        }

                        if (Response == PSEMResponse.Ok)
                        {
                            Response = ZigBeePSEM.Negotiate(CPSEM.DEFAULT_MAX_PACKET_LEGNTH,
                                                            CPSEM.DEFAULT_MAX_NUMBER_OF_PACKETS, (uint)9600);
                        }

                        if (Response == PSEMResponse.Ok)
                        {
                            Response = ZigBeePSEM.Logon("", CPSEM.DEFAULT_HH_PRO_USER_ID);
                        }

                        if (Response == PSEMResponse.Ok)
                        {
                            ZigBeeDevice = CreateDevice(ZigBeePSEM, m_AuthorizationKey);

                            if (m_AuthorizationKey != null && m_AuthorizationKey.IsValid &&
                                ZigBeeDevice.SignedAuthorizationState != null &&
                                ZigBeeDevice.SignedAuthorizationState.Value != FeatureState.Disabled)
                            {
                                // We should use signed authorization to log on to the meter.
                                ZigBeeDevice.Authenticate(m_AuthorizationKey);
                            }
                            else
                            {
                                ZigBeeDevice.Security(GetPasswords());
                            }

                            if (ZigBeeDevice.HANMACAddress == m_ulMACAddress)
                            {
                                bCouldLogon = true;
                            }
                            else
                            {
                                bCouldLogon = false;
                            }
                        }
                    }
                    catch (Exception) { }
                    finally
                    {
                        try
                        {
                            ZigBeeDevice.Logoff();
                        }
                        catch { }
                    }
                }

                if (ZigBeeRadio != null)
                {
                    try
                    {
                        ZigBeeRadio.ClosePort();
                    }
                    catch { }
                }
            }