public static async Task Aggregator(
            FPGA.OutputSignal <bool> LED1,
            FPGA.InputSignal <bool> RXD,
            FPGA.OutputSignal <bool> TXD
            )
        {
            Sequential handler = () =>
            {
                FPU.FPUScope();

                const int width = 10;
                const int baud  = 115200;

                ComplexFloat[] data = new ComplexFloat[GeneratorTools.ArrayLength(width)];

                while (true)
                {
                    RTX.ReadData(baud, RXD, data);

                    DFT.Transform(width, data, Direction.Forward);

                    RTX.WriteData(baud, TXD, data, 0);
                }
            };

            FPGA.Config.OnStartup(handler);

            Drivers.IsAlive.Blink(LED1);
        }
        public static async Task Aggregator(
            FPGA.InputSignal <bool> RXD,
            FPGA.OutputSignal <bool> TXD
            )
        {
            uint clockCounter = 0;

            Diag.ClockCounter(clockCounter);

            Sequential handler = () =>
            {
                FPU.FPUScopeNoSync();

                const int width = 10;
                const int baud  = 115200;

                ComplexFloat[] source = new ComplexFloat[GeneratorTools.ArrayLength(width)];
                ComplexFloat[] target = new ComplexFloat[GeneratorTools.ArrayLength(width)];
                FPGA.Config.NoSync(source);

                while (true)
                {
                    RTX.ReadData(baud, RXD, source);

                    uint start = clockCounter;
                    FFT.Transform(width, source, target, Direction.Forward);
                    uint end = clockCounter;

                    RTX.WriteData(baud, TXD, target, end - start);
                }
            };

            FPGA.Config.OnStartup(handler);
        }
        public static async Task Aggregator(
            FPGA.OutputSignal <bool> LED1,
            FPGA.InputSignal <bool> RXD,
            FPGA.OutputSignal <bool> TXD
            )
        {
            Sequential handler = () =>
            {
                FPU.FPUScope();

                const int width = 10;
                const int baud  = 115200;

                ComplexFloat[] data = new ComplexFloat[GeneratorTools.ArrayLength(width)];

                while (true)
                {
                    RTX.ReadData(baud, RXD, data);

                    for (int idx = 0; idx < data.Length; idx++)
                    {
                        ComplexFloat tmp = new ComplexFloat();
                        tmp = data[idx];

                        tmp.Re = 1024f;
                        tmp.Im = tmp.Im + 10f;

                        data[idx] = tmp;
                    }

                    RTX.WriteData(baud, TXD, data, 0);
                }
            };

            FPGA.Config.OnStartup(handler);

            Drivers.IsAlive.Blink(LED1);
        }