Ejemplo n.º 1
0
        public static void ReloadTankDefs()
        {
            tankTypes.Clear();

            // Structural tank type is hard coded
            tankTypes.Add(structuralTankName, StructuralTankType);

            foreach (var node in GameDatabase.Instance.GetConfigNodes("B9_TANK_TYPE"))
            {
                TankType         t       = new TankType();
                OperationContext context = new OperationContext(Operation.LoadPrefab, t);

                try
                {
                    t.Load(node, context);
                }
                catch (Exception ex)
                {
                    Exception ex2 = new Exception($"Fatal exception while loading tank type {t.tankName ?? "<unknown>"}", ex);
                    FatalErrorHandler.HandleFatalError(ex2);
                    throw ex2;
                }

                if (tankTypes.ContainsKey(t.tankName))
                {
                    Log.error("B9TankSettings: The tank type {0} already exists", t.tankName);
                    continue;
                }
                tankTypes.Add(t.tankName, t);
                Log.info("B9TankSettings: registered tank type {0}", t.tankName);
            }

            LoadedTankDefs = true;
        }
 public static void Spawn(ModuleB9PartSwitch module)
 {
     try
     {
         MaybeCreateResourceRemovalWarning(module, () => CreateDialogue(module));
     }
     catch (Exception ex)
     {
         Log.error(ex, ex.Message);
         FatalErrorHandler.HandleFatalError(ex);
     }
 }
Ejemplo n.º 3
0
 public static void Spawn(ModuleB9PartSwitch module)
 {
     try
     {
         MaybeCreateResourceRemovalWarning(module, () => CreateDialogue(module));
     }
     catch (Exception ex)
     {
         UnityEngine.Debug.LogException(ex);
         FatalErrorHandler.HandleFatalError(ex);
     }
 }
Ejemplo n.º 4
0
        public override void OnLoad(ConfigNode node)
        {
            base.OnLoad(node);

            if (!moduleID.IsNullOrEmpty() && node.HasValue(nameof(moduleID)))
            {
                string newID = node.GetValue(nameof(moduleID));
                if (!string.Equals(moduleID, newID))
                {
                    var correctModule = part.Modules.OfType <CustomPartModule>().FirstOrDefault(m => m != this && m.GetType() == this.GetType() && m.moduleID == newID);
                    if (correctModule.IsNotNull())
                    {
                        LogWarning("OnLoad was called with the wrong ModuleID ('" + newID + "'), but found the correct module to load");
                        correctModule.Load(node);
                    }
                    else
                    {
                        LogError("OnLoad was called with the wrong ModuleID and the correct module could not be found");
                    }
                    return;
                }
            }

            bool             loadingPrefab = part.partInfo.IsNull() || node.name == CURRENT_UPGRADE;
            Operation        operation     = loadingPrefab ? Operation.LoadPrefab : Operation.LoadInstance;
            OperationContext context       = new OperationContext(operation, this);

            try
            {
                this.LoadFields(node, context);
            }
            catch (Exception ex)
            {
                Exception ex2 = new Exception($"Fatal exception while loading fields on module {this}", ex);
                FatalErrorHandler.HandleFatalError(ex2);
                throw ex2;
            }

            if (loadingPrefab)
            {
                OnLoadPrefab(node);
            }
            else
            {
                OnLoadInstance(node);
            }
        }
Ejemplo n.º 5
0
        public override void OnSave(ConfigNode node)
        {
            base.OnSave(node);

            OperationContext context = new OperationContext(Operation.Save, this);

            try
            {
                this.SaveFields(node, context);
            }
            catch (Exception ex)
            {
                Exception ex2 = new Exception($"Fatal exception while saving fields on module {this}", ex);
                FatalErrorHandler.HandleFatalError(ex2);
                throw ex2;
            }
        }