Ejemplo n.º 1
0
        // Call the GISPKG_CCB_ESILOCATION.ValidateESILocation stored procedure to validate
        // if the ESI Location is being used by a Premise record on a different Service Point.
        private bool ValidateDuplicate(string esiLocation, int g3eFID)
        {
            bool returnValue = true;

            try
            {
                ADODB.Command cmd = new ADODB.Command();

                cmd.CommandText = "{call GISPKG_CCB_ESILOCATION.ValidateESILocation(?,?,?,?,?)}";
                cmd.CommandType = CommandTypeEnum.adCmdText;

                ADODB.Parameter param = cmd.CreateParameter("ESILocation", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 10, esiLocation);
                cmd.Parameters.Append(param);
                param = cmd.CreateParameter("G3EFID", DataTypeEnum.adBigInt, ParameterDirectionEnum.adParamInput, 10, g3eFID);
                cmd.Parameters.Append(param);
                param = cmd.CreateParameter("ExistingFID", DataTypeEnum.adBigInt, ParameterDirectionEnum.adParamOutput, 10);
                cmd.Parameters.Append(param);
                param = cmd.CreateParameter("JobID", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamOutput, 30);
                cmd.Parameters.Append(param);
                param = cmd.CreateParameter("Status", DataTypeEnum.adSingle, ParameterDirectionEnum.adParamOutput, 1);
                cmd.Parameters.Append(param);

                int recordsAffected = 0;

                Recordset spRS = m_DataContext.ExecuteCommand(cmd, out recordsAffected);

                if (!Convert.ToBoolean(cmd.Parameters["Status"].Value))
                {
                    string job = string.Empty;

                    if (cmd.Parameters["JobID"].Value.ToString().Length > 0)
                    {
                        job = " in Job " + cmd.Parameters["JobID"].Value;
                    }
                    if (m_InteractiveMode)
                    {
                        MessageBox.Show(ERROR_DUPLICATE_ESILOCATION + cmd.Parameters["ExistingFID"].Value + job, "G/Technology", MessageBoxButtons.OK, MessageBoxIcon.Exclamation);
                    }
                    returnValue = false;
                }
            }
            catch (Exception ex)
            {
                if (m_InteractiveMode)
                {
                    MessageBox.Show("Error in fiESILocationUpdate:ValidateDuplicate - " + ex.Message, "G/Technology", MessageBoxButtons.OK, MessageBoxIcon.Exclamation);
                }
                returnValue = false;
            }

            return(returnValue);
        }
Ejemplo n.º 2
0
        /// <summary>
        /// Inserts a record into the DEIS_TRANSACTION table.
        /// </summary>
        /// <returns>Boolean indicating status</returns>
        private bool InsertTransaction()
        {
            bool returnValue = false;

            try
            {
                ADODB.Command cmd = new ADODB.Command();

                cmd.CommandText = "insert into deis_transaction (tran_code,tran_date,bank_fln,wr_no,serv_area,yard,user_id,conn_sec,existing_bank,wiring_config_code," +
                                  "locn,ins_trf1_company_no,ins_trf1_tsn,ins_trf1_kva_size,ins_trf1_phs_code,ins_trf1_type_code,ins_trf1_mount_code,ins_trf1_kind_code," +
                                  "ins_trf1_pri_volt_code,ins_trf1_sec_volt_code,ins_trf2_company_no,ins_trf2_tsn,ins_trf2_kva_size,ins_trf2_phs_code,ins_trf2_type_code," +
                                  "ins_trf2_mount_code,ins_trf2_kind_code,ins_trf2_pri_volt_code,ins_trf2_sec_volt_code,ins_trf3_company_no,ins_trf3_tsn,ins_trf3_kva_size," +
                                  "ins_trf3_phs_code,ins_trf3_type_code,ins_trf3_mount_code,ins_trf3_kind_code,ins_trf3_pri_volt_code,ins_trf3_sec_volt_code,rem_trf1_company_no," +
                                  "rem_trf1_tsn,rem_trf1_kva_size,rem_trf1_phs_code,rem_trf1_type_code,rem_trf1_mount_code,rem_trf1_kind_code,rem_trf1_pri_volt_code," +
                                  "rem_trf1_sec_volt_code,rem_trf2_company_no,rem_trf2_tsn,rem_trf2_kva_size,rem_trf2_phs_code,rem_trf2_type_code,rem_trf2_mount_code," +
                                  "rem_trf2_kind_code,rem_trf2_pri_volt_code,rem_trf2_sec_volt_code,rem_trf3_company_no,rem_trf3_tsn,rem_trf3_kva_size,rem_trf3_phs_code," +
                                  "rem_trf3_type_code,rem_trf3_mount_code,rem_trf3_kind_code,rem_trf3_pri_volt_code,rem_trf3_sec_volt_code) " +
                                  "values (?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?,?) " +
                                  "returning tran_no into ?";
                cmd.CommandType = CommandTypeEnum.adCmdText;

                // Input parameters
                ADODB.Parameter param = cmd.CreateParameter("TranCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 1, TransactionDEIS.TransactionCode);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("TranDate", DataTypeEnum.adDate, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.TransactionDate.Replace('T', ' '));
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("BankFLN", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.BankFLN);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("WrNo", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.WrNumber);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("ServArea", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.ServiceArea);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("Yard", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.Yard);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("UserID", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.UserID);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("SecConn", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.SecondaryConnection);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("ExistingBank", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.ExistingBank);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("WiringConfigCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.WiringConfigCode);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("Location", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.Location);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("InsTrf1CompanyNumber", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.InsTrf1CompanyNumber);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("InsTrf1TSN", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.InsTrf1TSN);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("InsTrf1KvaSize", DataTypeEnum.adDouble, ParameterDirectionEnum.adParamInput, 10, TransactionDEIS.InsTrf1KvaSize);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("InsTrf1PhaseCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.InsTrf1PhaseCode);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("InsTrf1TypeCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.InsTrf1TypeCode);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("InsTrf1MountCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.InsTrf1MountCode);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("InsTrf1KindCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.InsTrf1KindCode);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("InsTrf1PriVoltCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.InsTrf1PriVoltCode);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("InsTrf1SecVoltCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.InsTrf1SecVoltCode);
                cmd.Parameters.Append(param);


                param = cmd.CreateParameter("InsTrf2CompanyNumber", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.InsTrf2CompanyNumber);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("InsTrf2TSN", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.InsTrf2TSN);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("InsTrf2KvaSize", DataTypeEnum.adDouble, ParameterDirectionEnum.adParamInput, 10, TransactionDEIS.InsTrf2KvaSize);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("InsTrf2PhaseCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.InsTrf2PhaseCode);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("InsTrf2TypeCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.InsTrf2TypeCode);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("InsTrf2MountCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.InsTrf2MountCode);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("InsTrf2KindCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.InsTrf2KindCode);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("InsTrf2PriVoltCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.InsTrf2PriVoltCode);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("InsTrf2SecVoltCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.InsTrf2SecVoltCode);
                cmd.Parameters.Append(param);


                param = cmd.CreateParameter("InsTrf3CompanyNumber", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.InsTrf3CompanyNumber);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("InsTrf3TSN", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.InsTrf3TSN);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("InsTrf3KvaSize", DataTypeEnum.adDouble, ParameterDirectionEnum.adParamInput, 10, TransactionDEIS.InsTrf3KvaSize);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("InsTrf3PhaseCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.InsTrf3PhaseCode);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("InsTrf3TypeCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.InsTrf3TypeCode);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("InsTrf3MountCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.InsTrf3MountCode);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("InsTrf3KindCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.InsTrf3KindCode);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("InsTrf3PriVoltCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.InsTrf3PriVoltCode);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("InsTrf3SecVoltCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.InsTrf3SecVoltCode);
                cmd.Parameters.Append(param);


                param = cmd.CreateParameter("RemTrf1CompanyNumber", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.RemTrf1CompanyNumber);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("RemTrf1TSN", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.RemTrf1TSN);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("RemTrf1KvaSize", DataTypeEnum.adDouble, ParameterDirectionEnum.adParamInput, 10, TransactionDEIS.RemTrf1KvaSize);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("RemTrf1PhaseCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.RemTrf1PhaseCode);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("RemTrf1TypeCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.RemTrf1TypeCode);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("RemTrf1MountCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.RemTrf1MountCode);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("RemTrf1KindCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.RemTrf1KindCode);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("RemTrf1PriVoltCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.RemTrf1PriVoltCode);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("RemTrf1SecVoltCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.RemTrf1SecVoltCode);
                cmd.Parameters.Append(param);


                param = cmd.CreateParameter("RemTrf2CompanyNumber", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.RemTrf2CompanyNumber);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("RemTrf2TSN", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.RemTrf2TSN);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("RemTrf2KvaSize", DataTypeEnum.adDouble, ParameterDirectionEnum.adParamInput, 10, TransactionDEIS.RemTrf2KvaSize);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("RemTrf2PhaseCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.RemTrf2PhaseCode);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("RemTrf2TypeCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.RemTrf2TypeCode);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("RemTrf2MountCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.RemTrf2MountCode);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("RemTrf2KindCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.RemTrf2KindCode);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("RemTrf2PriVoltCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.RemTrf2PriVoltCode);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("RemTrf2SecVoltCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.RemTrf2SecVoltCode);
                cmd.Parameters.Append(param);


                param = cmd.CreateParameter("RemTrf3CompanyNumber", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.RemTrf3CompanyNumber);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("RemTrf3TSN", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.RemTrf3TSN);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("RemTrf3KvaSize", DataTypeEnum.adDouble, ParameterDirectionEnum.adParamInput, 10, TransactionDEIS.RemTrf3KvaSize);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("RemTrf3PhaseCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.RemTrf3PhaseCode);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("RemTrf3TypeCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.RemTrf3TypeCode);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("RemTrf3MountCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.RemTrf3MountCode);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("RemTrf3KindCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.RemTrf3KindCode);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("RemTrf3PriVoltCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.RemTrf3PriVoltCode);
                cmd.Parameters.Append(param);

                param = cmd.CreateParameter("RemTrf3SecVoltCode", DataTypeEnum.adVarChar, ParameterDirectionEnum.adParamInput, 30, TransactionDEIS.RemTrf3SecVoltCode);
                cmd.Parameters.Append(param);

                // Output parameter
                param = cmd.CreateParameter("TranNo", DataTypeEnum.adBigInt, ParameterDirectionEnum.adParamOutput, 10);
                cmd.Parameters.Append(param);

                int recordsAffected = 0;

                Recordset spRS = m_Application.DataContext.ExecuteCommand(cmd, out recordsAffected);

                m_Application.DataContext.Execute("commit", out recordsAffected, (int)CommandTypeEnum.adCmdText);

                if (!Convert.IsDBNull(cmd.Parameters["TranNo"].Value))
                {
                    TransactionDEIS.TransactionNumber = Convert.ToInt32(cmd.Parameters["TranNo"].Value);
                }

                returnValue = true;
            }
            catch (Exception ex)
            {
                TransactionDEIS.TransactionMessage = "FAILED - Error inserting record into " + TransactionDEIS.TABLE_DEIS_TRANSACTION + ": " + ex.Message;
                returnValue = false;
            }

            return(returnValue);
        }
Ejemplo n.º 3
0
        private void PrepareParameters()
        {
            // Prepare parameters
            SQLParameter parameter;

            for (int index = 0; index < _parameterIndexes.Length; index++)
            {
                parameter = Parameters[_parameterIndexes[index]];
                ADODB.Parameter aDOParameter = _command.CreateParameter(parameter.Name, ADODB.DataTypeEnum.adInteger, ADODB.ParameterDirectionEnum.adParamInput, 0, Missing.Value);
                switch (parameter.Direction)
                {
                case SQLDirection.In: aDOParameter.Direction = ADODB.ParameterDirectionEnum.adParamInput; break;

                case SQLDirection.Out: aDOParameter.Direction = ADODB.ParameterDirectionEnum.adParamOutput; break;

                case SQLDirection.InOut: aDOParameter.Direction = ADODB.ParameterDirectionEnum.adParamInputOutput; break;

                case SQLDirection.Result: aDOParameter.Direction = ADODB.ParameterDirectionEnum.adParamReturnValue; break;

                default: aDOParameter.Direction = ADODB.ParameterDirectionEnum.adParamUnknown; break;
                }

                if (parameter.Type is SQLStringType)
                {
                    aDOParameter.Type = ADODB.DataTypeEnum.adVarChar;
                    aDOParameter.Size = ((SQLStringType)parameter.Type).Length;
                }
                else if (parameter.Type is SQLBooleanType)
                {
                    aDOParameter.Type = ADODB.DataTypeEnum.adBoolean;
                }
                else if (parameter.Type is SQLIntegerType)
                {
                    switch (((SQLIntegerType)parameter.Type).ByteCount)
                    {
                    case 1: aDOParameter.Type = ADODB.DataTypeEnum.adTinyInt; break;

                    case 2: aDOParameter.Type = ADODB.DataTypeEnum.adSmallInt; break;

                    case 8: aDOParameter.Type = ADODB.DataTypeEnum.adBigInt; break;

                    default: aDOParameter.Type = ADODB.DataTypeEnum.adInteger; break;
                    }
                }
                else if (parameter.Type is SQLNumericType)
                {
                    SQLNumericType type = (SQLNumericType)parameter.Type;
                    aDOParameter.Type         = ADODB.DataTypeEnum.adNumeric;
                    aDOParameter.NumericScale = type.Scale;
                    aDOParameter.Precision    = type.Precision;
                }
                else if (parameter.Type is SQLFloatType)
                {
                    SQLFloatType type = (SQLFloatType)parameter.Type;
                    if (type.Width == 1)
                    {
                        aDOParameter.Type = ADODB.DataTypeEnum.adSingle;
                    }
                    else
                    {
                        aDOParameter.Type = ADODB.DataTypeEnum.adDouble;
                    }
                }
                else if (parameter.Type is SQLBinaryType)
                {
                    aDOParameter.Type        = ADODB.DataTypeEnum.adLongVarBinary;
                    aDOParameter.Attributes |= (int)ADODB.ParameterAttributesEnum.adParamLong;
                    aDOParameter.Size        = 255;
                }
                else if (parameter.Type is SQLByteArrayType)
                {
                    aDOParameter.Type = ADODB.DataTypeEnum.adBinary;
                    aDOParameter.Size = ((SQLByteArrayType)parameter.Type).Length;
                }
                else if (parameter.Type is SQLTextType)
                {
                    aDOParameter.Type = ADODB.DataTypeEnum.adLongVarChar;
                    aDOParameter.Size = 255;
                }
                else if (parameter.Type is SQLDateTimeType)
                {
                    aDOParameter.Type = ADODB.DataTypeEnum.adDBTimeStamp;
                }
                else if (parameter.Type is SQLDateType)
                {
                    aDOParameter.Type = ADODB.DataTypeEnum.adDBDate;
                }
                else if (parameter.Type is SQLTimeType)
                {
                    aDOParameter.Type = ADODB.DataTypeEnum.adDBTime;
                }
                else if (parameter.Type is SQLGuidType)
                {
                    aDOParameter.Type = ADODB.DataTypeEnum.adChar;
                    aDOParameter.Size = 38;
                    //LADOParameter.Type = ADODB.DataTypeEnum.adGUID;
                }
                else if (parameter.Type is SQLMoneyType)
                {
                    aDOParameter.Type = ADODB.DataTypeEnum.adCurrency;
                }
                else
                {
                    throw new ConnectionException(ConnectionException.Codes.UnknownSQLDataType, parameter.Type.GetType().Name);
                }
                _command.Parameters.Append(aDOParameter);
            }
        }