Ejemplo n.º 1
0
        public ActionResult Edit(string COM_CODE, decimal?USG_ID)
        {
            SetDefaulButton(StandardButtonMode.Modify);
            var da = new SECS02P001DA();

            SetStandardErrorLog(da.DTO);
            da.DTO.Execute.ExecuteType = SECS02P001ExecuteType.GetByID;

            TempModel          = null;
            TempModel.COM_CODE = da.DTO.Model.COM_CODE = COM_CODE;
            TempModel.USG_ID   = da.DTO.Model.USG_ID = USG_ID;

            da.Select(da.DTO);

            if (da.DTO.Model != null)
            {
                localModel = da.DTO.Model;
            }

            localModel.USG_STATUS_MODEL = GetUsgStatus();
            localModel.USG_LEVEL_MODEL  = GetUsgLevel();
            Set(localModel, "USG_LEVEL_MODEL");
            Set(localModel, "USG_STATUS_MODEL");

            return(View(StandardActionName.Edit, localModel));
        }
Ejemplo n.º 2
0
        private DTOResult SaveData(string mode, object model)
        {
            var da = new SECS02P001DA();

            SetStandardLog(
                da.DTO,
                model,
                GetSaveLogConfig("dbo", "OIC_T_SEC_USRGROUP", "COM_CODE", "USG_CODE"));

            if (mode == StandardActionName.SaveCreate)
            {
                SetStandardField(model);
                da.DTO.Execute.ExecuteType = SECS02P001ExecuteType.InsertData;
                da.DTO.Model = (SECS02P001Model)model;
                da.InsertNoEF(da.DTO);
            }
            else if (mode == StandardActionName.SaveModify)
            {
                SetStandardField(model);
                da.DTO.Execute.ExecuteType = SECS02P001ExecuteType.UpdateData;
                da.DTO.Model = (SECS02P001Model)model;
                da.UpdateNoEF(da.DTO);
            }
            else if (mode == StandardActionName.Delete)
            {
                da.DTO.Model = new SECS02P001Model();
                SetStandardField(da.DTO.Model);
                da.DTO.Execute.ExecuteType = SECS02P001ExecuteType.DeleteData;
                da.DTO.Models = (List <SECS02P001Model>)model;
                da.Delete(da.DTO);
            }
            else if (mode == "SaveConfPrg")
            {
                SetStandardField(model);
                da.DTO.Execute.ExecuteType = SECS02P001ExecuteType.UpdateUsgPriv;
                da.DTO.Model = (SECS02P001Model)model;
                da.Update(da.DTO);
            }
            else if (mode == "SaveConfSysSeq")
            {
                SetStandardField(model);
                da.DTO.Execute.ExecuteType = SECS02P001ExecuteType.UpdateSysSeq;
                da.DTO.Model = (SECS02P001Model)model;
                da.Update(da.DTO);
            }
            else if (mode == "SaveConfPrgSeq")
            {
                SetStandardField(model);
                da.DTO.Execute.ExecuteType = SECS02P001ExecuteType.UpdatePrgSeq;
                da.DTO.Model = (SECS02P001Model)model;
                da.Update(da.DTO);
            }

            return(da.DTO.Result);
        }
Ejemplo n.º 3
0
        public ActionResult GetSysSeq(string SYS_GROUP_NAME)
        {
            var da = new SECS02P001DA();

            SetStandardErrorLog(da.DTO);
            da.DTO.Execute.ExecuteType = SECS02P001ExecuteType.GetSysSeq;
            da.DTO.Model = TempModel.CloneObject();
            da.DTO.Model.SYS_GROUP_NAME = SYS_GROUP_NAME;
            da.SelectNoEF(da.DTO);

            return(JsonAllowGet(da.DTO.Model.PRIV_MODEL));
        }
Ejemplo n.º 4
0
        public ActionResult SYS_CODE_OnChange(string SYS_CODE)
        {
            var da = new SECS02P001DA();

            SetStandardErrorLog(da.DTO);
            da.DTO.Execute.ExecuteType = SECS02P001ExecuteType.GetUsgPriv;
            da.DTO.Model           = TempModel.CloneObject();
            da.DTO.Model.SYS_CODE  = SYS_CODE;
            da.DTO.Model.USG_LEVEL = TempModel.USG_LEVEL;
            da.SelectNoEF(da.DTO);
            return(JsonAllowGet(da.DTO.Model.PRIV_MODEL));
        }
Ejemplo n.º 5
0
        private SECS02P001Model GET_VSMS_USRGROUP(string COM_CODE, decimal?USG_ID)
        {
            var da = new SECS02P001DA();

            SetStandardErrorLog(da.DTO);
            da.DTO.Execute.ExecuteType = SECS02P001ExecuteType.GetByID;
            da.DTO.Model.COM_CODE      = COM_CODE;
            da.DTO.Model.USG_ID        = USG_ID;

            da.Select(da.DTO);

            return(da.DTO.Model);
        }
Ejemplo n.º 6
0
        public ActionResult Search(SECS02P001Model model)
        {
            var da = new SECS02P001DA();

            SetStandardErrorLog(da.DTO);
            da.DTO.Execute.ExecuteType = SECS02P001ExecuteType.GetAll;

            if (Request.GetRequest("page").IsNullOrEmpty())
            {
                model.IsDefaultSearch = true;
                TempSearch            = model;
            }

            da.DTO.Model = TempSearch;

            da.Select(da.DTO);
            return(JsonAllowGet(da.DTO.Models));
        }
Ejemplo n.º 7
0
        public ActionResult ConfSysSeq(string COM_CODE, string USG_LEVEL, decimal?USG_ID)
        {
            SetDefaulButton(StandardButtonMode.Other);
            AddStandardButton(StandardButtonName.SaveModify, url: Url.Action("SaveConfSysSeq"));
            var da = new SECS02P001DA();

            SetStandardErrorLog(da.DTO);
            da.DTO.Execute.ExecuteType = SECS02P001ExecuteType.GetByID;

            TempModel           = null;
            TempModel.COM_CODE  = da.DTO.Model.COM_CODE = COM_CODE;
            TempModel.USG_ID    = da.DTO.Model.USG_ID = USG_ID;
            TempModel.USG_LEVEL = da.DTO.Model.USG_LEVEL = USG_LEVEL;

            da.Select(da.DTO);

            if (da.DTO.Model != null)
            {
                localModel = da.DTO.Model;
            }
            localModel.SYS_GROUP_NAME_MODEL = GetDDLCenter(DDLCenterKey.DD_VSMS_USRGROUP_003, new VSMParameter(COM_CODE.Trim()), new VSMParameter(USG_LEVEL));
            return(View("ConfSysSeq", localModel));
        }
Ejemplo n.º 8
0
        public ActionResult ConfPrg(string COM_CODE, decimal?USG_ID)
        {
            SetDefaulButton(StandardButtonMode.Other);
            AddStandardButton(StandardButtonName.SaveModify, url: Url.Action("SaveConfPrg"));
            var da = new SECS02P001DA();

            SetStandardErrorLog(da.DTO);
            da.DTO.Execute.ExecuteType = SECS02P001ExecuteType.GetByID;

            TempModel          = null;
            TempModel.COM_CODE = da.DTO.Model.COM_CODE = COM_CODE;
            TempModel.USG_ID   = da.DTO.Model.USG_ID = USG_ID;

            da.Select(da.DTO);

            if (da.DTO.Model != null)
            {
                localModel          = da.DTO.Model;
                TempModel.USG_LEVEL = da.DTO.Model.USG_LEVEL;
            }

            localModel.SYS_CODE_MODEL = GetDDLCenter(DDLCenterKey.DD_VSMS_SYSTEM_002);
            return(View("ConfPrg", localModel));
        }