private void ShowDataToForm(int ID, string temperatureUnit, string pressureUnit, string flowRateUnit)
        {
            RW_STREAM_BUS             SteamBus = new RW_STREAM_BUS();
            RW_EXTCOR_TEMPERATURE_BUS tempBus  = new RW_EXTCOR_TEMPERATURE_BUS();
            RW_STREAM             objSteam     = SteamBus.getData(ID);
            RW_EXTCOR_TEMPERATURE extTemp      = tempBus.getData(ID);
            BUS_UNITS             convUnit     = new BUS_UNITS();

            switch (temperatureUnit)
            {
            case "DEG_C":
                txtMaximumOperatingTemp.Text = objSteam.MaxOperatingTemperature.ToString();
                txtMinimumOperatingTemp.Text = objSteam.MinOperatingTemperature.ToString();
                txtCriticalExposure.Text     = objSteam.CriticalExposureTemperature.ToString();
                break;

            case "DEG_F":
                txtMaximumOperatingTemp.Text = convUnit.CelToFah(objSteam.MaxOperatingTemperature).ToString();
                txtMinimumOperatingTemp.Text = convUnit.CelToFah(objSteam.MinOperatingTemperature).ToString();
                txtCriticalExposure.Text     = convUnit.CelToFah(objSteam.CriticalExposureTemperature).ToString();
                Console.WriteLine("Hha");
                break;

            case "K":
                txtMaximumOperatingTemp.Text = convUnit.CelToKenvin(objSteam.MaxOperatingTemperature).ToString();
                txtMinimumOperatingTemp.Text = convUnit.CelToKenvin(objSteam.MinOperatingTemperature).ToString();
                txtCriticalExposure.Text     = convUnit.CelToKenvin(objSteam.CriticalExposureTemperature).ToString();
                break;
            }
            switch (pressureUnit)
            {
            case "psi":
                txtMaxOperatingPressure.Text = objSteam.MaxOperatingPressure.ToString();
                txtMinOperatingPressure.Text = objSteam.MinOperatingPressure.ToString();
                txtOperatingHydrogen.Text    = objSteam.H2SPartialPressure.ToString();
                break;

            case "KSI":
                txtMaxOperatingPressure.Text = (objSteam.MaxOperatingPressure / convUnit.ksi).ToString();
                txtMinOperatingPressure.Text = (objSteam.MinOperatingPressure / convUnit.ksi).ToString();
                txtOperatingHydrogen.Text    = (objSteam.H2SPartialPressure / convUnit.ksi).ToString();
                break;

            case "bar":
                txtMaxOperatingPressure.Text = (objSteam.MaxOperatingPressure / convUnit.bar).ToString();
                txtMinOperatingPressure.Text = (objSteam.MinOperatingPressure / convUnit.bar).ToString();
                txtOperatingHydrogen.Text    = (objSteam.H2SPartialPressure / convUnit.bar).ToString();
                break;

            case "MPa":
                txtMaxOperatingPressure.Text = (objSteam.MaxOperatingPressure / convUnit.MPa).ToString();
                txtMinOperatingPressure.Text = (objSteam.MinOperatingPressure / convUnit.MPa).ToString();
                txtOperatingHydrogen.Text    = (objSteam.H2SPartialPressure / convUnit.MPa).ToString();
                break;

            case "N/m2":
                txtMaxOperatingPressure.Text = (objSteam.MaxOperatingPressure / convUnit.NpM2).ToString();
                txtMinOperatingPressure.Text = (objSteam.MinOperatingPressure / convUnit.NpM2).ToString();
                txtOperatingHydrogen.Text    = (objSteam.H2SPartialPressure / convUnit.NpM2).ToString();
                break;

            case "N/cm2":
                txtMaxOperatingPressure.Text = (objSteam.MaxOperatingPressure / convUnit.NpCM2).ToString();
                txtMinOperatingPressure.Text = (objSteam.MinOperatingPressure / convUnit.NpCM2).ToString();
                txtOperatingHydrogen.Text    = (objSteam.H2SPartialPressure / convUnit.NpCM2).ToString();
                break;
            }
            switch (flowRateUnit)
            {
            case "ft3/hr":
                txtFlowRate.Text = (objSteam.FlowRate / convUnit.ft3).ToString();
                break;

            case "m3/hr":
                txtFlowRate.Text = objSteam.FlowRate.ToString();
                break;
            }

            txtOp12.Text  = extTemp.Minus12ToMinus8.ToString();
            txtOp8.Text   = extTemp.Minus8ToPlus6.ToString();
            txtOp6.Text   = extTemp.Plus6ToPlus32.ToString();
            txtOp32.Text  = extTemp.Plus32ToPlus71.ToString();
            txtOp71.Text  = extTemp.Plus71ToPlus107.ToString();
            txtOp107.Text = extTemp.Plus107ToPlus121.ToString();
            txtOp121.Text = extTemp.Plus121ToPlus135.ToString();
            txtOp135.Text = extTemp.Plus135ToPlus162.ToString();
            txtOp162.Text = extTemp.Plus162ToPlus176.ToString();
            txtOp176.Text = extTemp.MoreThanPlus176.ToString();
        }
        public void ShowDataToControl(int ID, string temUnit, string volumeUnit)
        {
            RW_EQUIPMENT_BUS bus = new RW_EQUIPMENT_BUS();
            RW_EQUIPMENT     eq  = bus.getData(ID);

            chkAministrativeControl.Checked = Convert.ToBoolean(eq.AdminUpsetManagement);
            chkCylicOperation.Checked       = Convert.ToBoolean(eq.CyclicOperation);
            chkDowntimeProtection.Checked   = Convert.ToBoolean(eq.DowntimeProtectionUsed);
            for (int i = 0; i < itemsAdjustmentSettlement.Length; i++)
            {
                if (eq.ExternalEnvironment == itemsAdjustmentSettlement[i])
                {
                    cbAdjustmentSettlement.SelectedIndex = i + 1;
                    break;
                }
            }
            chkHeatTraced.Checked            = Convert.ToBoolean(eq.HeatTraced);
            chkInterfaceSoilWater.Checked    = Convert.ToBoolean(eq.InterfaceSoilWater);
            chkLinerOnlineMonitoring.Checked = Convert.ToBoolean(eq.LinerOnlineMonitoring);
            chkMaterialExposedFluid.Checked  = Convert.ToBoolean(eq.MaterialExposedToClExt);
            if (temUnit == "DEG_C")
            {
                txtMinRequiredTemperature.Text = eq.MinReqTemperaturePressurisation.ToString();
            }
            else if (temUnit == "DEG_F")
            {
                txtMinRequiredTemperature.Text = (convUnit.CelToFah(eq.MinReqTemperaturePressurisation)).ToString();                          // mai
            }
            else
            {
                txtMinRequiredTemperature.Text = (convUnit.CelToKenvin(eq.MinReqTemperaturePressurisation)).ToString();  // mai
            }
            for (int i = 0; i < itemsOnlineMonitoring.Length; i++)
            {
                if (eq.OnlineMonitoring == itemsOnlineMonitoring[i])
                {
                    cbOnlineMonitoring.SelectedIndex = i + 1;
                    break;
                }
            }
            chkPresenceSulphideOperation.Checked = Convert.ToBoolean(eq.PresenceSulphidesO2);
            chkPresenceSulphideShutdown.Checked  = Convert.ToBoolean(eq.PresenceSulphidesO2Shutdown);
            chkPressurisationControlled.Checked  = Convert.ToBoolean(eq.PressurisationControlled);
            chkPWHT.Checked = Convert.ToBoolean(eq.PWHT);
            chkSteamedOutPriorWaterFlushing.Checked = Convert.ToBoolean(eq.SteamOutWaterFlush);
            numSystemManagementFactor.Value         = (decimal)eq.ManagementFactor;
            for (int i = 0; i < itemsThermalHistory.Length; i++)
            {
                if (eq.ThermalHistory == itemsThermalHistory[i])
                {
                    cbThermalHistory.SelectedIndex = i + 1;
                    break;
                }
            }
            chkEquipmentOperatingManyYear.Checked = Convert.ToBoolean(eq.YearLowestExpTemp);
            if (volumeUnit == "m3")
            {
                txtEquipmentVolume.Text = eq.Volume.ToString();                     //mai
            }
            else if (volumeUnit == "ft3")
            {
                txtEquipmentVolume.Text = (eq.Volume / convUnit.ft3).ToString();                           // mai
            }
            for (int i = 0; i < itemsExternalEnvironment.Length; i++)
            {
                if (eq.ExternalEnvironment == itemsExternalEnvironment[i])
                {
                    cbExternalEnviroment.SelectedIndex = i + 1;
                    break;
                }
            }
            for (int i = 0; i < itemsTypeSoil.Length; i++)
            {
                if (eq.TypeOfSoil == itemsTypeSoil[i])
                {
                    cbTypeSoild.SelectedIndex = i + 1;
                    break;
                }
            }
            for (int i = 0; i < itemsEnvironmental.Length; i++)
            {
                if (eq.EnvironmentSensitivity == itemsEnvironmental[i])
                {
                    cbEnvironmentalSensitivity.SelectedIndex = i + 1;
                    break;
                }
            }
            for (int i = 0; i < itemsAdjustmentSettlement.Length; i++)
            {
                if (eq.AdjustmentSettle == itemsAdjustmentSettlement[i])
                {
                    cbAdjustmentSettlement.SelectedIndex = i + 1;
                    break;
                }
            }
            chkComponentWelded.Checked          = Convert.ToBoolean(eq.ComponentIsWelded);
            chkTankMaintainedAccordance.Checked = Convert.ToBoolean(eq.TankIsMaintained);
            txtDistanceGroundWater.Text         = eq.DistanceToGroundWater.ToString();
        }
        public void ShowDatatoControl(int ID, string temUnit, string volumeUnit)
        {
            RW_EQUIPMENT_BUS    eqBus    = new RW_EQUIPMENT_BUS();
            BUS_UNITS           convUnit = new BUS_UNITS();
            List <RW_EQUIPMENT> listEq   = eqBus.getDataSource();

            foreach (RW_EQUIPMENT e in listEq)
            {
                if (e.ID == ID)
                {
                    chkAministrativeControl.Checked      = e.AdminUpsetManagement == 1 ? true : false;
                    chkHighlyEffectiveInspection.Checked = e.HighlyDeadlegInsp == 1 ? true : false;
                    chkDowntimeProtection.Checked        = e.DowntimeProtectionUsed == 1 ? true : false;
                    chkHeatTraced.Checked                   = e.HeatTraced == 1 ? true : false;
                    chkInterfaceSoilWater.Checked           = e.InterfaceSoilWater == 1 ? true : false;
                    chkEquipmentOperatingManyYear.Checked   = e.YearLowestExpTemp == 1 ? true : false;
                    chkMaterialExposedFluid.Checked         = e.MaterialExposedToClExt == 1 ? true : false;
                    chkPresenceSulphideOperation.Checked    = e.PresenceSulphidesO2 == 1 ? true : false;
                    chkContainsDeadlegs.Checked             = e.ContainsDeadlegs == 1 ? true : false;
                    chkCylicOperation.Checked               = e.CyclicOperation == 1 ? true : false;
                    chkSteamedOutPriorWaterFlushing.Checked = e.SteamOutWaterFlush == 1 ? true : false;
                    chkPWHT.Checked = e.PWHT == 1 ? true : false;
                    chkLinerOnlineMonitoring.Checked    = e.LinerOnlineMonitoring == 1 ? true : false;
                    chkPresenceSulphideShutdown.Checked = e.PresenceSulphidesO2Shutdown == 1 ? true : false;
                    if (temUnit == "DEG_C")
                    {
                        txtMinRequiredTemperature.Text = e.MinReqTemperaturePressurisation.ToString();
                    }
                    else if (temUnit == "DEG_F")
                    {
                        txtMinRequiredTemperature.Text = (convUnit.CelToFah(e.MinReqTemperaturePressurisation)).ToString();
                    }
                    else
                    {
                        txtMinRequiredTemperature.Text = (convUnit.CelToKenvin(e.MinReqTemperaturePressurisation)).ToString();
                    }
                    for (int i = 0; i < itemsExternalEnvironment.Length; i++)
                    {
                        if (itemsExternalEnvironment[i] == e.ExternalEnvironment)
                        {
                            cbExternalEnvironment.SelectedIndex = i + 1;
                        }
                    }
                    for (int j = 0; j < itemsOnlineMonitoring.Length; j++)
                    {
                        if (itemsOnlineMonitoring[j] == e.OnlineMonitoring)
                        {
                            cbOnlineMonitoring.SelectedIndex = j + 1;
                        }
                    }
                    for (int i = 0; i < itemsThermalHistory.Length; i++)
                    {
                        if (itemsThermalHistory[i] == e.ThermalHistory)
                        {
                            cbThermalHistory.SelectedIndex = i + 1;
                        }
                    }
                    if (volumeUnit == "m3")
                    {
                        txtEquipmentVolume.Text = e.Volume.ToString();
                    }
                    else if (volumeUnit == "ft3")
                    {
                        txtEquipmentVolume.Text = (e.Volume * convUnit.ft3).ToString();
                    }
                }
            }
        }
        public void ShowDataToControl(int ID, string temUnit, string pressureUnit, string stressUnit, string thicknessUnit, string corrosionUnit)
        {
            RW_MATERIAL_BUS      BUS      = new RW_MATERIAL_BUS();
            RW_MATERIAL          obj      = BUS.getData(ID);
            RW_INPUT_CA_TANK_BUS busTank  = new RW_INPUT_CA_TANK_BUS();
            BUS_UNITS            convUnit = new BUS_UNITS();
            float tank = busTank.getProductionCost(ID);

            switch (temUnit)
            {
            case "DEG_C":
                txtMaxDesignTemperature.Text = obj.DesignTemperature.ToString();
                txtMinDesignTemperature.Text = obj.MinDesignTemperature.ToString();
                txtReferenceTemperature.Text = obj.ReferenceTemperature.ToString();
                break;

            case "DEG_F":
                txtMaxDesignTemperature.Text = (convUnit.CelToFah(obj.DesignTemperature)).ToString();
                txtMinDesignTemperature.Text = (convUnit.CelToFah(obj.MinDesignTemperature)).ToString();
                txtReferenceTemperature.Text = (convUnit.CelToFah(obj.ReferenceTemperature)).ToString();
                break;

            case "K":
                txtMaxDesignTemperature.Text = (convUnit.CelToKenvin(obj.DesignTemperature)).ToString();
                txtMinDesignTemperature.Text = (convUnit.CelToKenvin(obj.MinDesignTemperature)).ToString();
                txtReferenceTemperature.Text = (convUnit.CelToKenvin(obj.ReferenceTemperature)).ToString();
                break;
            }

            switch (pressureUnit)
            {
            case "psi":
                txtDesignPressure.Text = obj.DesignPressure.ToString();
                break;

            case "KSI":
                txtDesignPressure.Text = (obj.DesignPressure / convUnit.ksi).ToString();
                break;

            case "bar":
                txtDesignPressure.Text = (obj.DesignPressure / convUnit.bar).ToString();
                break;

            case "MPa":
                txtDesignPressure.Text = (obj.DesignPressure / convUnit.MPa).ToString();
                break;

            case "N/m2":
                txtDesignPressure.Text = (obj.DesignPressure / convUnit.NpM2).ToString();
                break;

            case "N/cm2":
                txtDesignPressure.Text = (obj.DesignPressure / convUnit.NpCM2).ToString();
                break;
            }

            switch (thicknessUnit)
            {
            case "mm":
                txtBrittleFracture.Text = obj.BrittleFractureThickness.ToString();
                break;

            case "in":
                txtBrittleFracture.Text = (obj.BrittleFractureThickness / convUnit.inch).ToString();
                break;

            case "m":
                txtBrittleFracture.Text = (obj.BrittleFractureThickness / convUnit.meter).ToString();
                break;
            }

            switch (corrosionUnit)
            {
            case "mm":
                txtCorrosionAllowance.Text = obj.CorrosionAllowance.ToString();
                break;

            case "mil":
                txtCorrosionAllowance.Text = (obj.CorrosionAllowance / convUnit.mil).ToString();
                break;
            }

            switch (stressUnit)
            {
            case "psi":
                txtAllowableStress.Text = obj.AllowableStress.ToString();
                break;

            case "KSI":
                txtAllowableStress.Text = (obj.AllowableStress / convUnit.ksi).ToString();
                break;

            case "bar":
                txtAllowableStress.Text = (obj.AllowableStress / convUnit.bar).ToString();
                break;

            case "MPa":
                txtAllowableStress.Text = (obj.AllowableStress / convUnit.MPa).ToString();
                break;

            case "N/m2":
                txtAllowableStress.Text = (obj.AllowableStress / convUnit.NpM2).ToString();
                break;

            case "N/cm2":
                txtAllowableStress.Text = (obj.AllowableStress / convUnit.NpCM2).ToString();
                break;
            }
            txtMaterial.Text = obj.MaterialName;
            for (int i = 0; i < itemsSulfurContent.Length; i++)
            {
                if (obj.SulfurContent == itemsSulfurContent[i])
                {
                    cbSulfurContent.SelectedIndex = i + 1;
                    break;
                }
            }
            for (int i = 0; i < itemsHeatTreatment.Length; i++)
            {
                if (obj.HeatTreatment == itemsHeatTreatment[i])
                {
                    cbHeatTreatment.SelectedIndex = i + 1;
                    break;
                }
            }

            for (int i = 0; i < itemsPTAMterial.Length; i++)
            {
                if (obj.PTAMaterialCode == itemsPTAMterial[i])
                {
                    cbPTAMaterialGrade.SelectedIndex = i + 1;
                    break;
                }
            }
            chkIsPTASeverity.Checked       = Convert.ToBoolean(obj.IsPTA);
            chkAusteniticSteel.Checked     = Convert.ToBoolean(obj.Austenitic);
            chkCarbonLowAlloySteel.Checked = Convert.ToBoolean(obj.CarbonLowAlloy);
            chkNickelAlloy.Checked         = Convert.ToBoolean(obj.NickelBased);
            chkChromium.Checked            = Convert.ToBoolean(obj.ChromeMoreEqual12);
            txtMaterialCostFactor.Text     = obj.CostFactor.ToString();
            txtProductionCost.Text         = tank.ToString();
        }
Ejemplo n.º 5
0
        public void ShowDatatoControl(int id, string temperatureUnit, string pressureUnit, string corrosionUnit)
        {
            RW_MATERIAL_BUS BUS      = new RW_MATERIAL_BUS();
            RW_MATERIAL     obj      = BUS.getData(id);
            BUS_UNITS       convUnit = new BUS_UNITS();

            txtMaterial.Text = obj.MaterialName;
            switch (temperatureUnit)
            {
            case "DEG_C":
                txtMaxDesignTemperature.Text = obj.DesignTemperature.ToString();
                txtMinDesignTemperature.Text = obj.MinDesignTemperature.ToString();
                txtReferenceTemperature.Text = obj.ReferenceTemperature.ToString();
                break;

            case "DEG_F":
                txtMaxDesignTemperature.Text = (convUnit.CelToFah(obj.DesignTemperature)).ToString();
                txtMinDesignTemperature.Text = (convUnit.CelToFah(obj.MinDesignTemperature)).ToString();
                txtReferenceTemperature.Text = (convUnit.CelToFah(obj.ReferenceTemperature)).ToString();
                break;

            case "K":
                txtMaxDesignTemperature.Text = (convUnit.CelToKenvin(obj.DesignTemperature)).ToString();
                txtMinDesignTemperature.Text = (convUnit.CelToKenvin(obj.MinDesignTemperature)).ToString();
                txtReferenceTemperature.Text = (convUnit.CelToKenvin(obj.ReferenceTemperature)).ToString();
                break;
            }

            switch (pressureUnit)
            {
            case "PSI":
                txtDesignPressure.Text  = (obj.DesignPressure / convUnit.psi).ToString();
                txtYieldStrength.Text   = (obj.YieldStrength / convUnit.psi).ToString();
                txtTensileStrength.Text = (obj.TensileStrength / convUnit.psi).ToString();
                break;

            case "KSI":
                txtDesignPressure.Text  = (obj.DesignPressure / convUnit.ksi).ToString();
                txtYieldStrength.Text   = (obj.YieldStrength / convUnit.ksi).ToString();
                txtTensileStrength.Text = (obj.TensileStrength / convUnit.ksi).ToString();
                break;

            case "BAR":
                txtDesignPressure.Text  = (obj.DesignPressure / convUnit.bar).ToString();
                txtYieldStrength.Text   = (obj.YieldStrength / convUnit.bar).ToString();
                txtTensileStrength.Text = (obj.TensileStrength / convUnit.bar).ToString();
                break;

            case "MPA":
                txtDesignPressure.Text  = (obj.DesignPressure).ToString();
                txtYieldStrength.Text   = (obj.YieldStrength).ToString();
                txtTensileStrength.Text = (obj.TensileStrength).ToString();
                break;

            case "NM2":
                txtDesignPressure.Text  = (obj.DesignPressure / convUnit.NpM2).ToString();
                txtYieldStrength.Text   = (obj.YieldStrength / convUnit.NpM2).ToString();
                txtTensileStrength.Text = (obj.TensileStrength / convUnit.NpM2).ToString();
                break;

            case "NCM2":
                txtDesignPressure.Text  = (obj.DesignPressure / convUnit.NpCM2).ToString();
                txtYieldStrength.Text   = (obj.YieldStrength / convUnit.NpCM2).ToString();
                txtTensileStrength.Text = (obj.TensileStrength / convUnit.NpCM2).ToString();
                break;
            }

            switch (corrosionUnit)
            {
            case "MM":
                txtCorrosionAllowance.Text = obj.CorrosionAllowance.ToString();
                break;

            case "MIL":
                txtCorrosionAllowance.Text = (obj.CorrosionAllowance / convUnit.mil).ToString();
                break;
            }
            txtSigmaPhase.Text = obj.SigmaPhase.ToString();
            for (int i = 0; i < itemsSulfurContent.Length; i++)
            {
                if (obj.SulfurContent == itemsSulfurContent[i])
                {
                    cbSulfurContent.SelectedIndex = i + 1;
                    break;
                }
            }
            for (int i = 0; i < itemsPTAMterial.Length; i++)
            {
                if (obj.PTAMaterialCode == itemsPTAMterial[i])
                {
                    cbPTAMaterialGrade.SelectedIndex = i + 1;
                    break;
                }
            }
            for (int i = 0; i < itemsHTHAMaterial.Length; i++)
            {
                if (obj.HTHAMaterialCode == itemsHTHAMaterial[i])
                {
                    cbHTHAMaterial.SelectedIndex = i + 1;
                    break;
                }
            }
            chkIsPTASeverity.Checked       = Convert.ToBoolean(obj.IsPTA);
            chkIsHTHASeverity.Checked      = Convert.ToBoolean(obj.IsHTHA);
            chkAusteniticSteel.Checked     = Convert.ToBoolean(obj.Austenitic);
            chkSusceptibleTemper.Checked   = Convert.ToBoolean(obj.Temper);
            chkCarbonLowAlloySteel.Checked = Convert.ToBoolean(obj.CarbonLowAlloy);
            chkNickelAlloy.Checked         = Convert.ToBoolean(obj.NickelBased);
            chkChromium.Checked            = Convert.ToBoolean(obj.ChromeMoreEqual12);
            txtTensileStrength.Text        = obj.TensileStrength.ToString();
            txtYieldStrength.Text          = obj.YieldStrength.ToString();
            txtMaterialCostFactor.Text     = obj.CostFactor.ToString();
        }